mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 707)
This commit is contained in:
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.3-RELEASE amd64] (local build)
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.3-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -12,7 +12,7 @@ Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Jan 26 12:33:33 2022 AEDT
|
||||
Local Time is: Wed Dec 14 15:58:46 2022 AEDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 5
|
||||
3 Spin_Up_Time POS--K 253 167 021 - 1916
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 499
|
||||
3 Spin_Up_Time POS--K 212 167 021 - 4375
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 503
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 034 034 000 - 48744
|
||||
9 Power_On_Hours -O--CK 033 033 000 - 49518
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 306
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 194
|
||||
193 Load_Cycle_Count -O--CK 025 025 000 - 526345
|
||||
194 Temperature_Celsius -O---K 116 104 000 - 34
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 310
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 197
|
||||
193 Load_Cycle_Count -O--CK 025 025 000 - 526346
|
||||
194 Temperature_Celsius -O---K 118 104 000 - 32
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -145,8 +145,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/37 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/32 Celsius
|
||||
Lifetime Min/Max Temperature: 0/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -155,7 +155,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (178)
|
||||
Temperature History Size (Index): 478 (226)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -172,9 +172,9 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 1789780 Vendor specific
|
||||
0x8000 4 306 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
Reference in New Issue
Block a user