@@ -15,7 +15,7 @@ TRIM Command: Available
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Aug 26 11:11:55 2021 BST
Local Time is: Thu Dec 9 09:07:46 2021 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 092 092 000 - 40299
12 Power_Cycle_Count -O--CK 099 099 000 - 84
177 Wear_Leveling_Count PO--C- 084 084 000 - 323
9 Power_On_Hours -O--CK 091 091 000 - 42818
12 Power_Cycle_Count -O--CK 099 099 000 - 85
177 Wear_Leveling_Count PO--C- 084 084 000 - 332
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 066 042 000 - 34
190 Airflow_Temperature_Cel -O--CK 064 042 000 - 36
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 71
241 Total_LBAs_Written -O--CK 099 099 000 - 120666599553
235 POR_Recovery_Count -O--C- 099 099 000 - 72
241 Total_LBAs_Written -O--CK 099 099 000 - 125900380817
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -130,8 +130,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: 31/42 Celsius
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 30/43 Celsius
Lifetime Min/Max Temperature: 26/58 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -140,7 +140,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (90)
Temperature History Size (Index): 128 (98)
SCT Error Recovery Control:
Read: Disabled
@@ -160,8 +160,8 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 33 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 33 Device-to-host register FISes sent due to a COMRESET
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC