smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.8] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SAMSUNG HD161HJ
Serial Number: --
LU WWN Device Id: 5 0000f0 ...
Firmware Version: JF100-19
User Capacity: 160,037,658,112 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b
Local Time is: Tue Jan 5 14:11:58 2021 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 3000) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 51) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0007 253 253 025 Pre-fail Always - 4416
4 Start_Stop_Count 0x0032 096 096 000 Old_age Always - 4129
5 Reallocated_Sector_Ct 0x0033 253 253 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0
8 Seek_Time_Performance 0x0025 253 253 015 Pre-fail Offline - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 20727
10 Spin_Retry_Count 0x0033 253 253 051 Pre-fail Always - 0
11 Calibration_Retry_Count 0x0012 253 253 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 097 097 000 Old_age Always - 3115
13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 219446201
184 End-to-End_Error 0x0033 253 253 099 Pre-fail Always - 0
187 Reported_Uncorrect 0x0032 253 253 000 Old_age Always - 0
188 Command_Timeout 0x0032 253 253 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 157 097 000 Old_age Always - 27 (Min/Max 9/47)
194 Temperature_Celsius 0x0022 157 094 000 Old_age Always - 27 (Min/Max 9/48)
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 219446201
196 Reallocated_Event_Count 0x0032 253 253 000 Old_age Always - 0
197 Current_Pending_Sector 0x0012 253 253 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 253 253 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0
201 Soft_Read_Error_Rate 0x000a 100 100 000 Old_age Always - 0
202 Data_Address_Mark_Errs 0x0032 100 100 000 Old_age Always - 40
SMART Error Log Version: 1
ATA Error Count: 75 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 75 occurred at disk power-on lifetime: 11763 hours (490 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 00 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 01 00 00 00 e0 00 00:01:25.688 READ DMA
ec 00 00 00 00 00 a0 00 00:01:25.688 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 00 00:01:25.688 SET FEATURES [Set transfer mode]
ec 00 00 00 00 00 a0 00 00:01:25.688 IDENTIFY DEVICE
00 00 01 01 00 00 a0 00 00:01:25.500 NOP [Abort queued commands]
Error 74 occurred at disk power-on lifetime: 11763 hours (490 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 08 00 00 00 e0 Error: ICRC, ABRT 8 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 00 00 00 e0 00 00:03:25.125 READ DMA
ec 00 00 00 00 00 a0 00 00:03:25.125 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 00 00:03:25.125 SET FEATURES [Set transfer mode]
ec 00 00 00 00 00 a0 00 00:03:25.125 IDENTIFY DEVICE
00 00 01 01 00 00 a0 00 00:03:25.000 NOP [Abort queued commands]
Error 73 occurred at disk power-on lifetime: 11763 hours (490 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 08 00 00 00 e0 Error: ICRC, ABRT 8 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 00 00 00 e0 00 00:03:13.688 READ DMA
e0 00 00 00 00 00 a0 00 00:03:12.313 STANDBY IMMEDIATE
ec 00 00 00 00 00 a0 00 00:03:12.313 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 00 00:03:12.313 SET FEATURES [Set transfer mode]
ec 00 00 00 00 00 a0 00 00:03:12.313 IDENTIFY DEVICE
Error 72 occurred at disk power-on lifetime: 11763 hours (490 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 05 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000005 = 5
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 01 05 00 00 e0 00 00:02:41.813 READ DMA
c8 00 01 04 00 00 e0 00 00:02:41.813 READ DMA
c8 00 01 03 00 00 e0 00 00:02:41.813 READ DMA
c8 00 01 02 00 00 e0 00 00:02:41.813 READ DMA
c8 00 01 01 00 00 e0 00 00:02:41.813 READ DMA
Error 71 occurred at disk power-on lifetime: 11763 hours (490 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 04 00 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00000004 = 4
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 01 04 00 00 e0 00 00:02:35.188 READ DMA
c8 00 01 03 00 00 e0 00 00:02:35.125 READ DMA
c8 00 01 02 00 00 e0 00 00:02:35.125 READ DMA
ec 00 00 00 00 00 a0 00 00:02:35.125 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 00 00:02:35.125 SET FEATURES [Set transfer mode]
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

View File

@@ -0,0 +1,169 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p6 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SAMSUNG HD161HJ
Serial Number: --
LU WWN Device Id: 5 0000f0 ...
Firmware Version: JF100-23
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b
Local Time is: Fri Jan 29 20:07:58 2021 +03
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 40) The self-test routine was interrupted
by the host with a hard or soft reset.
Total time to complete Offline
data collection: ( 2929) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 49) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0
3 Spin_Up_Time POS--- 253 253 025 - 4544
4 Start_Stop_Count -O--CK 062 062 000 - 38465
5 Reallocated_Sector_Ct PO--CK 253 253 010 - 0
7 Seek_Error_Rate POSR-- 253 253 051 - 0
8 Seek_Time_Performance P-S--K 253 253 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 11567
10 Spin_Retry_Count PO--CK 253 253 051 - 0
11 Calibration_Retry_Count -O--C- 253 253 000 - 0
12 Power_Cycle_Count -O--CK 081 081 000 - 19462
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 3291461
184 End-to-End_Error PO--CK 253 253 099 - 0
187 Reported_Uncorrect -O--CK 253 253 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 3
190 Airflow_Temperature_Cel -O---K 085 063 045 - 15 (Min/Max 10/37)
194 Temperature_Celsius -O---K 082 063 000 - 18 (Min/Max 10/37)
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 3291461
196 Reallocated_Event_Count -O--CK 253 253 000 - 0
197 Current_Pending_Sector -O--C- 253 253 000 - 0
198 Offline_Uncorrectable ----CK 253 253 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate -O-R-- 253 100 000 - 0
201 Soft_Read_Error_Rate -O-R-- 253 100 000 - 0
202 Data_Address_Mark_Errs -O--CK 253 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Interrupted (host reset) 80% 1 -
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 18 Celsius
Power Cycle Min/Max Temperature: 10/18 Celsius
Lifetime Min/Max Temperature: 10/49 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: -4/72 Celsius
Min/Max Temperature Limit: -9/77 Celsius
Temperature History Size (Index): 128 (120)
SCT Error Recovery Control:
Read: 75 (7.5 seconds)
Write: 75 (7.5 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8001 2 0 Vendor specific

View File

@@ -0,0 +1,317 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE-p1 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SAMSUNG HD161HJ
Serial Number: --
LU WWN Device Id: 5 0000f0 ...
Firmware Version: JF100-22
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b
Local Time is: Thu Dec 17 15:54:52 2020 +08
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 254
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Unavailable
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 2891) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 49) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 253 100 051 - 0
3 Spin_Up_Time POS--- 253 253 025 - 4480
4 Start_Stop_Count -O--CK 096 096 000 - 4370
5 Reallocated_Sector_Ct PO--CK 253 253 010 - 0
7 Seek_Error_Rate POSR-- 253 253 051 - 0
8 Seek_Time_Performance P-S--K 253 253 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 3597
10 Spin_Retry_Count PO--CK 253 253 051 - 0
11 Calibration_Retry_Count -O--C- 253 253 000 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 2357
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 91769
184 End-to-End_Error PO--CK 253 253 099 - 0
187 Reported_Uncorrect -O--CK 253 253 000 - 0
188 Command_Timeout -O--CK 253 253 000 - 0
190 Airflow_Temperature_Cel -O---K 157 115 000 - 27 (Min/Max 16/41)
194 Temperature_Celsius -O---K 151 106 000 - 29 (Min/Max 16/44)
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 91769
196 Reallocated_Event_Count -O--CK 253 253 000 - 0
197 Current_Pending_Sector -O--C- 253 253 000 - 0
198 Offline_Uncorrectable ----CK 253 253 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 1801
200 Multi_Zone_Error_Rate -O-R-- 253 100 000 - 0
201 Soft_Read_Error_Rate -O-R-- 253 100 000 - 0
202 Data_Address_Mark_Errs -O--CK 253 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Device Error Count: 2350 (device log contains only the most recent 8 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2350 [5] occurred at disk power-on lifetime: 11372 hours (473 days + 20 hours)
When the command that caused the error occurred, the device was doing SMART Offline or Self-test.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 00 c0 00 ef 98 c7 00 00 00 ca 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
58 00 00 00 c0 ca 00 00 ef 98 c6 00 00 00:00:00.005 [RESERVED]
58 00 00 00 c0 ca 00 00 ef 98 c5 00 00 00:00:00.005 [RESERVED]
58 00 00 00 c0 ca 00 00 ef 98 c4 00 00 00:00:00.005 [RESERVED]
58 00 00 00 c0 ca 00 00 ef 98 c3 00 00 00:00:00.005 [RESERVED]
00 00 16 01 8a 00 00 20 c0 00 20 2c a0 00:00:03.559 NOP [Reserved subcommand] [OBS-ACS-2]
Error 2349 [4] occurred at disk power-on lifetime: 11366 hours (473 days + 14 hours)
When the command that caused the error occurred, the device was in a reserved state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 00 00 01 e0 0f bc 00 00 12 35 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
06 01 00 12 00 35 00 00 e0 0f bb 00 00 00:00:00.005 DATA SET MANAGEMENT
06 01 00 12 00 35 00 00 e0 0f ba 00 00 00:00:00.005 DATA SET MANAGEMENT
06 01 00 12 00 35 00 00 e0 0f b9 00 00 00:00:00.005 DATA SET MANAGEMENT
06 01 00 12 00 35 00 00 e0 0f b8 00 00 00:00:00.005 DATA SET MANAGEMENT
09 11 89 11 91 00 00 11 06 c9 b1 02 11 00:00:00.000 [RESERVED]
Error 2348 [3] occurred at disk power-on lifetime: 25408 hours (1058 days + 16 hours)
When the command that caused the error occurred, the device was in a reserved state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 00 00 00 00 00 00 00 00 00 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 00 16 01 8d 00 00 20 c0 00 20 2d a1 00:00:03.559 NOP [Reserved subcommand] [OBS-ACS-2]
Error 2347 [2] occurred at disk power-on lifetime: 11372 hours (473 days + 20 hours)
When the command that caused the error occurred, the device was doing SMART Offline or Self-test.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
98 -- c0 ca ef 00 00 7a 00 05 58 00 c6
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
05 00 00 00 00 58 ef c5 ca 98 c0 7a 05 37d+06:47:05.472 [RESERVED]
c4 ef 98 58 ca 00 00 05 00 00 7a c0 c3 23d+18:10:39.471 READ MULTIPLE
e7 01 86 20 20 00 00 00 28 c0 00 03 00 37d+06:47:05.472 FLUSH CACHE
88 00 00 00 84 00 e0 98 51 15 40 a2 04 4d+09:26:35.878 [VENDOR SPECIFIC]
98 e0 15 45 ca 00 00 04 00 00 e1 40 97 43d+17:50:47.520 CHECK POWER MODE [RET-4]
Error 2346 [1] occurred at disk power-on lifetime: 16384 hours (682 days + 16 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
ca -- 15 e1 45 40 00 00 00 00 04 95 e0 Error:
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 20 20 00 00 e7 00 00 03 27 c0 0d 01 4d+04:33:57.248 NOP [Reserved subcommand] [OBS-ACS-2]
66 00 84 8c 40 88 00 e0 a2 51 15 70 00 26d+00:29:12.736 [RESERVED FOR SERIAL ATA]
e0 06 ca 04 e1 8c 00 00 40 00 00 15 e0 00:05:19.750 STANDBY IMMEDIATE
00 00 00 8a 40 04 06 e0 e1 ca 15 00 00 4d+04:24:07.424 NOP [Abort queued commands]
e0 c8 ca 04 e0 89 00 00 40 00 00 15 e0 00:05:19.688 STANDBY IMMEDIATE
Error 2345 [0] occurred at disk power-on lifetime: 5512 hours (229 days + 16 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 2c 15 82 70 a2 51 88 00 e0 66 00 Device Fault 5506 sectors at LBA = 0x70a2578800e0 = 123842555543776
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 04 e0 00 00 e0 82 00 15 40 00 ca 89 25d+15:09:52.516 READ DMA
00 80 40 e0 15 00 04 89 00 e0 ca 00 00 39d+09:28:03.201 NOP [Reserved subcommand] [OBS-ACS-2]
89 04 e0 00 00 e0 7f 00 15 40 00 ca 89 00:00:00.004 [VENDOR SPECIFIC]
00 00 00 00 c0 00 e7 00 0d 03 25 00 20 39d+09:28:03.198 NOP [Abort queued commands]
a0 29 40 e0 15 66 88 00 70 a2 51 2c 00 6d+05:09:30.752 PACKET
Error 2344 [7] occurred at disk power-on lifetime: 11372 hours (473 days + 20 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 00 40 00 e0 01 b9 00 00 00 ca 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
db 00 00 00 40 ca 00 00 e0 01 b8 00 00 00:00:00.005 ACKNOWLEDGE MEDIA CHANGE [RET-4]
db 00 2a 00 69 ca 00 00 e0 00 a1 00 00 00:00:00.005 ACKNOWLEDGE MEDIA CHANGE [RET-4]
db 00 40 00 29 ca 00 00 e0 00 a1 00 00 00:00:00.005 ACKNOWLEDGE MEDIA CHANGE [RET-4]
db 00 00 00 c0 ca 00 00 e0 01 b6 00 00 00:00:00.005 ACKNOWLEDGE MEDIA CHANGE [RET-4]
00 00 16 01 86 00 00 20 c0 00 20 2e a0 00:00:03.559 NOP [Reserved subcommand] [OBS-ACS-2]
Error 2343 [6] occurred at disk power-on lifetime: 11372 hours (473 days + 20 hours)
When the command that caused the error occurred, the device was doing SMART Offline or Self-test.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
00 -- 00 00 00 e3 5e 50 00 00 00 ca 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
64 00 40 00 00 ca 00 00 e3 5c e3 00 00 00:00:00.005 SEND FPDMA QUEUED
64 00 40 00 c0 c8 00 00 e3 5c e2 00 00 00:00:00.005 SEND FPDMA QUEUED
26 00 00 00 80 ca 00 00 e9 c9 ed 00 00 00:00:00.005 READ DMA QUEUED EXT [OBS-ACS-2]
26 00 00 00 40 ca 00 00 e9 c9 ec 00 00 00:00:00.005 READ DMA QUEUED EXT [OBS-ACS-2]
00 00 16 01 8d 00 00 20 c0 00 20 2d a1 00:00:03.559 NOP [Reserved subcommand] [OBS-ACS-2]
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 3502 -
# 2 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 29 Celsius
Power Cycle Min/Max Temperature: 26/29 Celsius
Lifetime Min/Max Temperature: 17/51 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: -4/72 Celsius
Min/Max Temperature Limit: -9/77 Celsius
Temperature History Size (Index): 128 (102)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8001 2 0 Vendor specific