mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 3084, modified: 0)
This commit is contained in:
319
HDD/Samsung/HD204/HD204UI/D03E927C011F
Normal file
319
HDD/Samsung/HD204/HD204UI/D03E927C011F
Normal file
@@ -0,0 +1,319 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint F4 EG (AF)
|
||||
Device Model: SAMSUNG HD204UI
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0024e9 ...
|
||||
Firmware Version: 1AQ10001
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Tue Dec 15 13:34:52 2020 CST
|
||||
|
||||
==> WARNING: Using smartmontools or hdparm with this
|
||||
drive may result in data loss due to a firmware bug.
|
||||
****** THIS DRIVE MAY OR MAY NOT BE AFFECTED! ******
|
||||
Buggy and fixed firmware report same version number!
|
||||
See the following web pages for details:
|
||||
http://knowledge.seagate.com/articles/en_US/FAQ/223571en
|
||||
https://www.smartmontools.org/wiki/SamsungF4EGBadBlocks
|
||||
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (20340) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 339) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 1176
|
||||
2 Throughput_Performance -OS--K 252 252 000 - 0
|
||||
3 Spin_Up_Time PO---K 067 066 025 - 10287
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1105
|
||||
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
|
||||
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
|
||||
8 Seek_Time_Performance --S--K 252 252 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 66001
|
||||
10 Spin_Retry_Count -O--CK 252 252 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 1
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1810
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 5727383
|
||||
191 G-Sense_Error_Rate -O---K 100 100 000 - 14
|
||||
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
|
||||
194 Temperature_Celsius -O---- 064 058 000 - 30 (Min/Max 16/45)
|
||||
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 2
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 2
|
||||
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 6067
|
||||
223 Load_Retry_Count -O--CK 100 100 000 - 1
|
||||
225 Load_Cycle_Count -O--CK 100 100 000 - 2002
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 2 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
Device Error Count: 6
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 6 [5] occurred at disk power-on lifetime: 37337 hours (1555 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 50 00 00 1a b2 10 68 40 00 Error: UNC at LBA = 0x1ab21068 = 447877224
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 01 00 00 00 1a b2 0f b8 40 00 00:20:37.741 READ FPDMA QUEUED
|
||||
60 00 00 00 50 00 00 1a b1 ef 08 40 00 00:20:37.742 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 1a b2 10 c0 40 00 00:20:37.742 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 1a b2 0f b8 40 00 00:20:37.742 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 1a b2 0e b0 40 00 00:20:37.742 READ FPDMA QUEUED
|
||||
|
||||
Error 5 [4] occurred at disk power-on lifetime: 29304 hours (1221 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 40 00 00 11 1c f1 98 40 00 Error: UNC at LBA = 0x111cf198 = 287109528
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 01 00 00 00 11 1c f0 d8 40 00 00:01:45.905 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 11 1c f2 e8 40 00 00:01:45.913 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 11 1c f1 e0 40 00 00:01:45.913 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 11 1c f0 d8 40 00 00:01:45.913 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 11 1c ef d0 40 00 00:01:45.913 READ FPDMA QUEUED
|
||||
|
||||
Error 4 [3] occurred at disk power-on lifetime: 29304 hours (1221 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 98 00 00 11 1c c0 10 40 00 Error: UNC at LBA = 0x111cc010 = 287096848
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 01 00 00 00 11 1c bf a8 40 00 00:01:45.905 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 11 1c c1 b8 40 00 00:01:45.907 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 11 1c c0 b0 40 00 00:01:45.907 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 11 1c bf a8 40 00 00:01:45.907 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 11 1c be a0 40 00 00:01:45.907 READ FPDMA QUEUED
|
||||
|
||||
Error 3 [2] occurred at disk power-on lifetime: 29304 hours (1221 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 a8 00 00 11 1c b4 58 40 00 Error: UNC at LBA = 0x111cb458 = 287093848
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 00 b0 00 00 11 1c b4 50 40 00 00:01:45.905 READ FPDMA QUEUED
|
||||
60 00 00 00 b0 00 00 11 1c b5 00 40 00 00:01:45.905 READ FPDMA QUEUED
|
||||
60 00 00 00 b0 00 00 11 1c b4 50 40 00 00:01:45.905 READ FPDMA QUEUED
|
||||
60 00 00 00 58 00 00 11 1c b1 e0 40 00 00:01:45.905 READ FPDMA QUEUED
|
||||
60 00 00 00 50 00 00 11 1c c7 e8 40 00 00:01:45.905 READ FPDMA QUEUED
|
||||
|
||||
Error 2 [1] occurred at disk power-on lifetime: 29304 hours (1221 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 f8 00 00 05 f6 5a b8 40 00 Error: WP at LBA = 0x05f65ab8 = 100031160
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 00 00 08 00 00 1e 21 fc 40 40 00 00:01:45.035 WRITE FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 05 f6 5a b0 40 00 00:01:45.024 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 05 f6 5c c0 40 00 00:01:45.030 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 05 f6 5b b8 40 00 00:01:45.030 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 05 f6 5a b0 40 00 00:01:45.030 READ FPDMA QUEUED
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 29304 hours (1221 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 10 00 00 05 f6 4e e8 40 00 Error: WP at LBA = 0x05f64ee8 = 100028136
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 00 00 08 00 00 1e 21 fc 18 40 00 00:01:45.029 WRITE FPDMA QUEUED
|
||||
60 00 00 00 50 00 00 05 f6 4e a8 40 00 00:01:45.024 READ FPDMA QUEUED
|
||||
60 00 00 00 50 00 00 05 f6 4f 00 40 00 00:01:45.025 READ FPDMA QUEUED
|
||||
60 00 00 00 50 00 00 05 f6 4d f8 40 00 00:01:45.025 READ FPDMA QUEUED
|
||||
60 00 00 00 50 00 00 05 f6 4e a8 40 00 00:01:45.025 READ FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (2 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 29294 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Completed [00% left] (0-65535)
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/34 Celsius
|
||||
Lifetime Min/Max Temperature: 14/68 Celsius
|
||||
Specified Max Operating Temperature: 80 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 5 minutes
|
||||
Temperature Logging Interval: 5 minutes
|
||||
Min/Max recommended Temperature: -5/80 Celsius
|
||||
Min/Max Temperature Limit: -10/85 Celsius
|
||||
Temperature History Size (Index): 128 (107)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0002 4 0 R_ERR response for data FIS
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 4 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 47 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 48 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x8e00 4 0 Vendor specific
|
||||
0x8e01 4 0 Vendor specific
|
||||
0x8e02 4 0 Vendor specific
|
||||
0x8e03 4 0 Vendor specific
|
||||
0x8e04 4 0 Vendor specific
|
||||
0x8e05 4 0 Vendor specific
|
||||
0x8e06 4 0 Vendor specific
|
||||
0x8e07 4 0 Vendor specific
|
||||
0x8e08 4 0 Vendor specific
|
||||
0x8e09 4 0 Vendor specific
|
||||
0x8e0a 4 0 Vendor specific
|
||||
0x8e0b 4 0 Vendor specific
|
||||
0x8e0c 4 0 Vendor specific
|
||||
0x8e0d 4 0 Vendor specific
|
||||
0x8e0e 4 0 Vendor specific
|
||||
0x8e0f 4 0 Vendor specific
|
||||
0x8e10 4 0 Vendor specific
|
||||
0x8e11 4 0 Vendor specific
|
||||
|
||||
|
||||
|
Reference in New Issue
Block a user