smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.11
|
||||
Device Model: ST31500341AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC1H
|
||||
User Capacity: 1,500,300,828,160 bytes [1.50 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Wed Feb 10 06:20:07 2021 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 617) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 294) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 119 099 006 - 201378728
|
||||
3 Spin_Up_Time PO---- 098 092 000 - 0
|
||||
4 Start_Stop_Count -O--CK 096 096 020 - 4311
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 10
|
||||
7 Seek_Error_Rate POSR-- 078 060 030 - 66085722
|
||||
9 Power_On_Hours -O--CK 094 094 000 - 5697
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 096 037 020 - 4514
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 099 099 000 - 1
|
||||
188 Command_Timeout -O--CK 100 092 000 - 4295230605
|
||||
189 High_Fly_Writes -O-RCK 001 001 000 - 199
|
||||
190 Airflow_Temperature_Cel -O---K 066 039 045 Past 34 (16 134 34 22 0)
|
||||
194 Temperature_Celsius -O---K 034 061 000 - 34 (0 15 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 042 023 000 - 201378728
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 5627 (192 199 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 4256112907
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 271413999
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2928 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
Device Error Count: 1
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 4916 hours (204 days + 20 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 57 4e 00 44 59 00 00 Error: WP at LBA = 0x574e004459 = 374970795097
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 00 00 08 00 1c 09 00 80 b0 40 00 00:01:01.482 WRITE FPDMA QUEUED
|
||||
61 00 00 00 08 00 1c 09 00 80 a0 40 00 00:01:01.482 WRITE FPDMA QUEUED
|
||||
61 00 00 00 08 00 1c 09 00 80 80 40 00 00:01:01.482 WRITE FPDMA QUEUED
|
||||
61 00 00 00 10 00 1c 13 00 40 e0 40 00 00:01:01.481 WRITE FPDMA QUEUED
|
||||
61 00 00 00 08 00 1c 0c 00 40 c8 40 00 00:01:01.481 WRITE FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 5683 -
|
||||
# 2 Short offline Completed without error 00% 5678 -
|
||||
# 3 Short offline Completed without error 00% 5669 -
|
||||
# 4 Short offline Completed without error 00% 5467 -
|
||||
# 5 Short offline Completed without error 00% 5463 -
|
||||
# 6 Short offline Completed without error 00% 5460 -
|
||||
# 7 Short offline Completed without error 00% 5458 -
|
||||
# 8 Short offline Completed without error 00% 5454 -
|
||||
# 9 Short offline Completed without error 00% 5449 -
|
||||
#10 Short offline Completed without error 00% 5442 -
|
||||
#11 Short offline Completed without error 00% 5437 -
|
||||
#12 Short offline Completed without error 00% 5409 -
|
||||
#13 Short offline Interrupted (host reset) 00% 5408 -
|
||||
#14 Extended offline Interrupted (host reset) 00% 5384 -
|
||||
#15 Short offline Completed without error 00% 5364 -
|
||||
#16 Short offline Completed without error 00% 5358 -
|
||||
#17 Short offline Completed without error 00% 5352 -
|
||||
#18 Extended offline Interrupted (host reset) 80% 5240 -
|
||||
#19 Short offline Completed without error 00% 5239 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/34 Celsius
|
||||
Lifetime Min/Max Temperature: 15/61 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (51)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
229
HDD/Seagate/ST3150/ST31500541AS/D0BC51DAAB50
Normal file
229
HDD/Seagate/ST3150/ST31500541AS/D0BC51DAAB50
Normal file
@@ -0,0 +1,229 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RC5 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda LP
|
||||
Device Model: ST31500541AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC34
|
||||
User Capacity: 1,500,301,910,016 bytes [1.50 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Sat Apr 3 17:33:45 2021 CST
|
||||
|
||||
==> WARNING: A firmware update for this drive may be available,
|
||||
see the following Seagate web pages:
|
||||
http://knowledge.seagate.com/articles/en_US/FAQ/207931en
|
||||
http://knowledge.seagate.com/articles/en_US/FAQ/213915en
|
||||
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 128 (quiet), recommended: 254
|
||||
APM level is: 192 (intermediate level without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 653) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 374) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 117 099 006 - 143432817
|
||||
3 Spin_Up_Time PO---- 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 098 098 020 - 2838
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 084 060 030 - 324954672
|
||||
9 Power_On_Hours -O--CK 056 056 000 - 38847
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1852
|
||||
183 Runtime_Bad_Block -O--CK 099 099 000 - 1
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 099 099 000 - 1
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 065 045 045 Past 35 (Min/Max 10/40)
|
||||
194 Temperature_Celsius -O---K 035 055 000 - 35 (0 1 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 064 030 000 - 143432817
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 39980 (254 40 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 3767908041
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 3401379258
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2928 Device vendor specific log
|
||||
0xbd GPL,SL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
Device Error Count: 1
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 10887 hours (453 days + 15 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 00 55 e1 3f 00 00 Error: UNC at LBA = 0x0055e13f = 5628223
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 20 20 00 08 00 00 00 55 e1 3f e0 00 00:00:05.286 READ DMA EXT
|
||||
25 20 20 00 02 00 00 00 60 10 85 e0 00 00:00:05.274 READ DMA EXT
|
||||
25 20 20 00 03 00 00 00 02 00 dc e0 00 00:00:05.274 READ DMA EXT
|
||||
25 20 20 00 05 00 00 00 02 00 d7 e0 00 00:00:05.274 READ DMA EXT
|
||||
25 20 20 00 02 00 00 00 60 00 49 e0 00 00:00:05.273 READ DMA EXT
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 31758 -
|
||||
# 2 Short offline Completed without error 00% 30927 -
|
||||
# 3 Short offline Completed without error 00% 30903 -
|
||||
# 4 Short offline Completed without error 00% 30879 -
|
||||
# 5 Short offline Completed without error 00% 30855 -
|
||||
# 6 Short offline Completed without error 00% 30831 -
|
||||
# 7 Short offline Completed without error 00% 30807 -
|
||||
# 8 Short offline Completed without error 00% 30783 -
|
||||
# 9 Short offline Completed without error 00% 30759 -
|
||||
#10 Short offline Completed without error 00% 30735 -
|
||||
#11 Short offline Completed without error 00% 30711 -
|
||||
#12 Short offline Completed without error 00% 30687 -
|
||||
#13 Short offline Completed without error 00% 30665 -
|
||||
#14 Short offline Completed without error 00% 30642 -
|
||||
#15 Short offline Completed without error 00% 30067 -
|
||||
#16 Short offline Completed without error 00% 30043 -
|
||||
#17 Short offline Completed without error 00% 30019 -
|
||||
#18 Short offline Completed without error 00% 29995 -
|
||||
#19 Short offline Completed without error 00% 29971 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 10/40 Celsius
|
||||
Lifetime Min/Max Temperature: 1/55 Celsius
|
||||
Under/Over Temperature Limit Count: 2/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (2)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 26 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
Reference in New Issue
Block a user