1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 3084, modified: 0)

This commit is contained in:
Andrey Ponomarenko
2021-05-18 23:01:35 +03:00
parent 8bb6808886
commit d96e63400c
3224 changed files with 547026 additions and 1866 deletions

View File

@@ -0,0 +1,174 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.14 (AF)
Device Model: ST320DM000-1BD14C
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: KC45
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Thu Jan 7 03:26:40 2021 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 208 (intermediate), recommended: 208
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 642) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 58) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 116 099 006 - 110325232
3 Spin_Up_Time PO---- 100 099 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 311
5 Reallocated_Sector_Ct PO--CK 096 096 036 - 1312
7 Seek_Error_Rate POSR-- 064 060 030 - 446976808310
9 Power_On_Hours -O--CK 049 049 000 - 45373
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 100 100 020 - 306
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error -O--CK 100 100 099 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 0 0 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 056 040 045 Past 44 (Min/Max 30/46 #6)
194 Temperature_Celsius -O---K 044 060 000 - 44 (0 17 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 029 024 000 - 110325232
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
240 Head_Flying_Hours ------ 100 253 000 - 45373h+23m+07.458s
241 Total_LBAs_Written ------ 100 253 000 - 27617260
242 Total_LBAs_Read ------ 100 253 000 - 1946566670
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL VS 2248 Device vendor specific log
0xa8 GPL,SL VS 129 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xab GPL VS 1 Device vendor specific log
0xb0 GPL VS 2928 Device vendor specific log
0xbd GPL VS 252 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 44 Celsius
Power Cycle Min/Max Temperature: 30/46 Celsius
Lifetime Min/Max Temperature: 17/61 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 59 minutes
Min/Max recommended Temperature: 14/55 Celsius
Min/Max Temperature Limit: 10/60 Celsius
Temperature History Size (Index): 128 (120)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS

View File

@@ -0,0 +1,343 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Samsung SpinPoint M8 (AF)
Device Model: ST320LM001 HN-M320MBB
Serial Number: --
LU WWN Device Id: 5 0004cf ...
Firmware Version: 2AR10002
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Fri Mar 12 07:44:24 2021 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 120) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: ( 4980) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 83) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 117
2 Throughput_Performance -OS--K 252 252 000 - 0
3 Spin_Up_Time PO---K 091 087 025 - 2857
4 Start_Stop_Count -O--CK 095 095 000 - 5620
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
8 Seek_Time_Performance --S--K 252 252 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 18482
10 Spin_Retry_Count -O--CK 252 252 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 176
12 Power_Cycle_Count -O--CK 095 095 000 - 5808
191 G-Sense_Error_Rate -O---K 100 100 000 - 45
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
194 Temperature_Celsius -O---- 055 045 000 - 45 (Min/Max 21/55)
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 1
198 Offline_Uncorrectable ----CK 252 252 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 5974
223 Load_Retry_Count -O--CK 100 100 000 - 176
225 Load_Cycle_Count -O--CK 039 039 000 - 621111
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 2 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xc0-0xdf GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Device Error Count: 50 (device log contains only the most recent 8 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 50 [1] occurred at disk power-on lifetime: 14594 hours (608 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 18 00 00 06 f4 6e 08 40 00 Error: UNC at LBA = 0x06f46e08 = 116682248
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 80 00 00 06 f4 6d a0 40 00 00:00:31.640 READ FPDMA QUEUED
60 00 00 00 80 00 00 06 f4 6d a0 40 00 00:00:31.776 READ FPDMA QUEUED
60 00 00 00 80 00 00 11 23 7a 50 40 00 00:00:31.776 READ FPDMA QUEUED
61 00 00 00 08 00 00 00 54 0a e0 40 00 00:00:31.776 WRITE FPDMA QUEUED
ec 00 00 00 00 00 00 00 00 00 00 00 00 00:00:31.775 IDENTIFY DEVICE
Error 49 [0] occurred at disk power-on lifetime: 14594 hours (608 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 18 00 00 06 f4 6e 08 40 00 Error: UNC at LBA = 0x06f46e08 = 116682248
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 80 00 00 11 23 7a 50 40 00 00:00:31.717 READ FPDMA QUEUED
60 00 00 00 80 00 00 06 f4 6d a0 40 00 00:00:31.702 READ FPDMA QUEUED
61 00 00 00 08 00 00 00 54 0a e0 40 00 00:00:31.715 WRITE FPDMA QUEUED
60 00 00 00 40 00 00 16 09 0f 58 40 00 00:00:31.715 READ FPDMA QUEUED
61 00 00 00 08 00 00 00 6c 41 40 40 00 00:00:31.715 WRITE FPDMA QUEUED
Error 48 [7] occurred at disk power-on lifetime: 14594 hours (608 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 08 00 00 06 f4 6e 08 40 00 Error: UNC at LBA = 0x06f46e08 = 116682248
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 06 f4 6e 08 40 00 00:00:31.642 READ FPDMA QUEUED
60 00 00 00 08 00 00 06 f4 6e 08 40 00 00:00:31.712 READ FPDMA QUEUED
60 00 00 00 08 00 00 1b 00 1d 58 40 00 00:00:31.712 READ FPDMA QUEUED
61 00 00 00 08 00 00 0b 53 78 f0 40 00 00:00:31.712 WRITE FPDMA QUEUED
ea 00 00 00 00 00 00 00 00 00 00 40 00 00:00:31.712 FLUSH CACHE EXT
Error 47 [6] occurred at disk power-on lifetime: 14594 hours (608 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 08 00 00 06 f4 6e 08 40 00 Error: UNC at LBA = 0x06f46e08 = 116682248
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 06 f4 6e 08 40 00 00:00:31.641 READ FPDMA QUEUED
60 00 00 00 08 00 00 06 f4 6e 08 40 00 00:00:31.710 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 28 00 00:00:31.710 READ LOG EXT
60 00 00 00 08 00 00 06 f4 6e 08 40 00 00:00:31.641 READ FPDMA QUEUED
60 00 00 00 08 00 00 06 f4 6e 08 40 00 00:00:31.708 READ FPDMA QUEUED
Error 46 [5] occurred at disk power-on lifetime: 14594 hours (608 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 08 00 00 06 f4 6e 08 40 00 Error: UNC at LBA = 0x06f46e08 = 116682248
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 06 f4 6e 08 40 00 00:00:31.641 READ FPDMA QUEUED
60 00 00 00 08 00 00 06 f4 6e 08 40 00 00:00:31.708 READ FPDMA QUEUED
61 00 00 00 08 00 00 00 6c 41 a0 40 00 00:00:31.708 WRITE FPDMA QUEUED
60 00 00 00 08 00 00 06 f4 6e 00 40 00 00:00:31.708 READ FPDMA QUEUED
60 00 00 00 08 00 00 06 f4 6d f8 40 00 00:00:31.708 READ FPDMA QUEUED
Error 45 [4] occurred at disk power-on lifetime: 14594 hours (608 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 98 00 00 06 f4 6e 08 40 00 Error: UNC at LBA = 0x06f46e08 = 116682248
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 01 00 00 00 06 f4 6d a0 40 00 00:00:31.640 READ FPDMA QUEUED
60 00 00 01 00 00 00 06 f4 6d a0 40 00 00:00:31.705 READ FPDMA QUEUED
60 00 00 00 80 00 00 1b 05 32 e8 40 00 00:00:31.705 READ FPDMA QUEUED
61 00 00 00 18 00 00 0f 9f d6 60 40 00 00:00:31.705 WRITE FPDMA QUEUED
61 00 00 01 00 00 00 0f 9f d5 60 40 00 00:00:31.705 WRITE FPDMA QUEUED
Error 44 [3] occurred at disk power-on lifetime: 14594 hours (608 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 98 00 00 06 f4 6e 08 40 00 Error: UNC at LBA = 0x06f46e08 = 116682248
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 01 00 00 00 06 f4 6d a0 40 00 00:00:31.640 READ FPDMA QUEUED
60 00 00 00 38 00 00 09 fb ee aa 40 00 00:00:31.703 READ FPDMA QUEUED
60 00 00 00 80 00 00 1b 01 66 68 40 00 00:00:31.703 READ FPDMA QUEUED
60 00 00 00 08 00 00 1a da dd e8 40 00 00:00:31.703 READ FPDMA QUEUED
60 00 00 01 00 00 00 06 f4 6d a0 40 00 00:00:31.703 READ FPDMA QUEUED
Error 43 [2] occurred at disk power-on lifetime: 14594 hours (608 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 41 00 98 00 00 06 f4 6e 08 40 00 Error: WP at LBA = 0x06f46e08 = 116682248
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 00 00 28 00 00 00 6c 41 f0 40 00 00:00:31.644 WRITE FPDMA QUEUED
60 00 00 01 00 00 00 06 f4 6d a0 40 00 00:00:31.640 READ FPDMA QUEUED
60 00 00 01 00 00 00 06 f4 6d a0 40 00 00:00:31.642 READ FPDMA QUEUED
60 00 00 01 00 00 00 06 f4 6c a0 40 00 00:00:31.642 READ FPDMA QUEUED
60 00 00 00 80 00 00 06 f4 6c 20 40 00 00:00:31.642 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (2 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed: read failure 80% 18475 116682248
# 2 Short offline Completed: read failure 90% 18470 116682248
# 3 Short offline Completed: read failure 90% 18425 116682248
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed_read_failure [80% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 45 Celsius
Power Cycle Min/Max Temperature: 27/45 Celsius
Lifetime Min/Max Temperature: 22/55 Celsius
Specified Max Operating Temperature: 80 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 5 minutes
Temperature Logging Interval: 5 minutes
Min/Max recommended Temperature: -5/80 Celsius
Min/Max Temperature Limit: -10/85 Celsius
Temperature History Size (Index): 128 (33)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 2 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8e00 4 0 Vendor specific
0x8e01 4 0 Vendor specific
0x8e02 4 0 Vendor specific
0x8e03 4 0 Vendor specific
0x8e04 4 0 Vendor specific
0x8e05 4 0 Vendor specific
0x8e06 4 0 Vendor specific
0x8e07 4 0 Vendor specific
0x8e08 4 0 Vendor specific
0x8e09 4 0 Vendor specific
0x8e0a 4 0 Vendor specific
0x8e0b 4 0 Vendor specific
0x8e0c 4 0 Vendor specific
0x8e0d 4 0 Vendor specific
0x8e0e 4 0 Vendor specific
0x8e0f 4 0 Vendor specific
0x8e10 4 0 Vendor specific
0x8e11 4 0 Vendor specific

View File

@@ -0,0 +1,178 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p13-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Momentus Thin
Device Model: ST320LT007-9ZV142
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: 0004LVM1
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7242 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sat Feb 20 00:39:40 2021 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unknown
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 64) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x303b) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 118 099 034 - 177048512
3 Spin_Up_Time PO---- 098 098 000 - 0
4 Start_Stop_Count -O--CK 099 099 020 - 1603
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 075 060 030 - 30331438551
9 Power_On_Hours -O--CK 093 093 000 - 6683 (147 209 0)
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 099 099 020 - 1598
184 End-to-End_Error -O--CK 100 100 099 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 097 000 - 74
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 074 051 045 - 26 (Min/Max 26/27)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 67
192 Power-Off_Retract_Count -O--CK 100 100 000 - 16
193 Load_Cycle_Count -O--CK 087 087 000 - 27990
194 Temperature_Celsius -O---K 026 049 000 - 26 (0 8 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 052 040 000 - 177048512
196 Reallocated_Event_Count POSR-- 093 093 030 - 6409 (60886 0)
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
250 Read_Error_Retry_Rate ------ 001 001 000 - 33788
251 Unknown_Attribute ------ 100 001 000 - 964
252 Unknown_Attribute ------ 100 001 000 - 0
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL VS 2248 Device vendor specific log
0xa8 GPL,SL VS 65 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xab GPL VS 1 Device vendor specific log
0xb0 GPL VS 2864 Device vendor specific log
0xbd GPL VS 1 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0x50) Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 26 Celsius
Power Cycle Min/Max Temperature: 26/27 Celsius
Lifetime Min/Max Temperature: 8/49 Celsius
Under/Over Temperature Limit Count: 0/3
Vendor specific:
00 00 00 00 00 00 00 00 00 00 02 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 11 minutes
Min/Max recommended Temperature: 0/ 0 Celsius
Min/Max Temperature Limit: 0/ 0 Celsius
Temperature History Size (Index): 128 (62)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS

View File

@@ -0,0 +1,186 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p6 i386] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Momentus Thin
Device Model: ST320LT007-9ZV142
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: 0004HPM1
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sat Apr 24 09:41:05 2021 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unknown
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 64) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 119 099 006 - 212227784
3 Spin_Up_Time PO---K 098 098 000 - 0
4 Start_Stop_Count -O--CK 097 097 000 - 3767
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-K 076 060 030 - 52047603489
9 Power_On_Hours -O--CK 094 094 000 - 6095
10 Spin_Retry_Count PO--CK 100 100 097 - 0
12 Power_Cycle_Count -O--CK 097 097 000 - 3756
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 099 000 - 49
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 074 054 045 - 26 (Min/Max 19/26)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 95
192 Power-Off_Retract_Count -O---K 100 100 000 - 0
193 Load_Cycle_Count -O--CK 087 087 000 - 27835
194 Temperature_Celsius -O---K 026 046 000 - 26 (0 14 0 0 0)
195 Hardware_ECC_Recovered -O-RCK 050 039 000 - 212227784
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
250 Read_Error_Retry_Rate ------ 100 001 000 - 1424
251 Unknown_Attribute ------ 100 001 000 - 266
252 Unknown_Attribute ------ 100 001 000 - 117
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL VS 2248 Device vendor specific log
0xa8 GPL,SL VS 65 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xab GPL VS 1 Device vendor specific log
0xb0 GPL VS 2864 Device vendor specific log
0xbd GPL VS 1 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 6040 -
# 2 Extended offline Aborted by host 90% 6038 -
# 3 Short offline Completed without error 00% 6038 -
# 4 Short offline Interrupted (host reset) 00% 5251 -
# 5 Short offline Completed without error 00% 4081 -
# 6 Short offline Completed without error 00% 4066 -
# 7 Short offline Completed without error 00% 4034 -
# 8 Short offline Completed without error 00% 4023 -
# 9 Short offline Completed without error 00% 4011 -
#10 Short offline Completed without error 00% 3877 -
#11 Short offline Completed without error 00% 3838 -
#12 Short offline Completed without error 00% 3805 -
#13 Short offline Completed without error 00% 3780 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 26 Celsius
Power Cycle Min/Max Temperature: 20/26 Celsius
Lifetime Min/Max Temperature: 14/46 Celsius
Under/Over Temperature Limit Count: 0/1
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 30 minutes
Min/Max recommended Temperature: 0/ 0 Celsius
Min/Max Temperature Limit: 0/ 0 Celsius
Temperature History Size (Index): 128 (44)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS

View File

@@ -0,0 +1,323 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Laptop HDD
Device Model: ST320LT012-9WS14C
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: 0001LVM1
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Fri Feb 12 04:26:06 2021 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 82) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x1031) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 113 096 034 - 57849408
3 Spin_Up_Time PO---- 099 099 000 - 0
4 Start_Stop_Count -O--CK 091 091 020 - 9460
5 Reallocated_Sector_Ct PO--CK 095 095 036 - 832
7 Seek_Error_Rate POSR-- 081 060 030 - 4424453505
9 Power_On_Hours -O--CK 080 080 000 - 18282 (238 119 0)
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 092 092 020 - 8532
184 End-to-End_Error -O--CK 100 100 099 - 0
187 Reported_Uncorrect -O--CK 001 001 000 - 245
188 Command_Timeout -O--CK 100 099 000 - 1310742
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 061 041 045 Past 39 (0 45 39 34 0)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 498
192 Power-Off_Retract_Count -O--CK 100 100 000 - 255
193 Load_Cycle_Count -O--CK 001 001 000 - 887756
194 Temperature_Celsius -O---K 039 059 000 - 39 (0 8 0 0 0)
196 Reallocated_Event_Count POSR-- 085 085 030 - 13393 (35674 0)
197 Current_Pending_Sector -O--C- 100 098 000 - 0
198 Offline_Uncorrectable ----C- 100 098 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL VS 2248 Device vendor specific log
0xa8 GPL,SL VS 65 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xab GPL VS 1 Device vendor specific log
0xb0 GPL VS 2864 Device vendor specific log
0xbd-0xbf GPL VS 65535 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 2522 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2522 [1] occurred at disk power-on lifetime: 6310 hours (262 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 09 39 38 00 00 Error: UNC at LBA = 0x00093938 = 604472
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 80 00 00 00 09 29 88 40 00 00:02:42.438 READ FPDMA QUEUED
60 00 00 00 80 00 00 00 09 22 08 40 00 00:02:42.350 READ FPDMA QUEUED
60 00 00 00 80 00 00 00 09 1a 88 40 00 00:02:42.261 READ FPDMA QUEUED
60 00 00 00 80 00 00 00 09 1a 08 40 00 00:02:42.178 READ FPDMA QUEUED
60 00 00 00 80 00 00 00 09 19 88 40 00 00:02:42.178 READ FPDMA QUEUED
Error 2521 [0] occurred at disk power-on lifetime: 6308 hours (262 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 09 39 38 00 00 Error: UNC at LBA = 0x00093938 = 604472
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 40 00 00 01 11 b0 c0 40 00 00:13:13.780 READ FPDMA QUEUED
60 00 00 00 40 00 00 02 57 05 70 40 00 00:13:13.780 READ FPDMA QUEUED
60 00 00 00 28 00 00 00 a9 ae a0 40 00 00:13:13.778 READ FPDMA QUEUED
60 00 00 00 40 00 00 02 57 25 b0 40 00 00:13:13.777 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 09 39 38 40 00 00:13:13.774 READ FPDMA QUEUED
Error 2520 [19] occurred at disk power-on lifetime: 6308 hours (262 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 09 39 38 00 00 Error: UNC at LBA = 0x00093938 = 604472
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 00 09 39 38 40 00 00:13:10.976 READ FPDMA QUEUED
60 00 00 00 3c 00 00 00 a7 db aa 40 00 00:13:10.976 READ FPDMA QUEUED
60 00 00 00 40 00 00 02 57 25 70 40 00 00:13:10.955 READ FPDMA QUEUED
60 00 00 00 40 00 00 00 a9 ae 60 40 00 00:13:10.955 READ FPDMA QUEUED
61 00 00 00 08 00 00 00 13 9c 10 40 00 00:13:10.954 WRITE FPDMA QUEUED
Error 2519 [18] occurred at disk power-on lifetime: 6308 hours (262 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 09 39 38 00 00 Error: UNC at LBA = 0x00093938 = 604472
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 40 00 00 00 a9 ae 60 40 00 00:13:08.181 READ FPDMA QUEUED
60 00 00 00 40 00 00 02 57 25 70 40 00 00:13:08.168 READ FPDMA QUEUED
60 00 00 00 40 00 00 02 56 e7 30 40 00 00:13:08.165 READ FPDMA QUEUED
60 00 00 00 16 00 00 00 d9 3f 80 40 00 00:13:08.159 READ FPDMA QUEUED
60 00 00 00 40 00 00 02 56 e6 f0 40 00 00:13:08.149 READ FPDMA QUEUED
Error 2518 [17] occurred at disk power-on lifetime: 6308 hours (262 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 09 39 38 00 00 Error: UNC at LBA = 0x00093938 = 604472
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 02 56 d0 e8 40 00 00:13:05.231 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 09 39 38 40 00 00:13:05.231 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 cf a7 00 40 00 00:13:05.230 READ FPDMA QUEUED
61 00 00 00 08 00 00 00 6f 22 00 40 00 00:13:05.230 WRITE FPDMA QUEUED
60 00 00 00 08 00 00 00 3d dc da 40 00 00:13:05.230 READ FPDMA QUEUED
Error 2517 [16] occurred at disk power-on lifetime: 6308 hours (262 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 09 39 38 00 00 Error: UNC at LBA = 0x00093938 = 604472
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 02 56 d0 e0 40 00 00:13:02.329 READ FPDMA QUEUED
61 00 00 00 08 00 00 00 6f 21 88 40 00 00:13:02.326 WRITE FPDMA QUEUED
61 00 00 00 08 00 00 00 6f 22 08 40 00 00:13:02.325 WRITE FPDMA QUEUED
61 00 00 00 08 00 00 02 56 cf f8 40 00 00:13:02.325 WRITE FPDMA QUEUED
61 00 00 00 08 00 00 02 56 cf f0 40 00 00:13:02.325 WRITE FPDMA QUEUED
Error 2516 [15] occurred at disk power-on lifetime: 6308 hours (262 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 09 39 38 00 00 Error: UNC at LBA = 0x00093938 = 604472
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 01 3a 20 80 40 00 00:12:59.210 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 9f f1 40 40 00 00:12:59.208 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 9f f1 38 40 00 00:12:59.107 READ FPDMA QUEUED
61 00 00 00 08 00 00 00 6f 22 00 40 00 00:12:59.107 WRITE FPDMA QUEUED
60 00 00 00 08 00 00 00 09 39 38 40 00 00:12:59.107 READ FPDMA QUEUED
Error 2515 [14] occurred at disk power-on lifetime: 6308 hours (262 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 0d 65 08 00 00 Error: UNC at LBA = 0x000d6508 = 877832
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 01 00 00 00 00 0d 5f 00 40 00 00:12:55.986 READ FPDMA QUEUED
60 00 00 01 00 00 00 00 0d 5e 00 40 00 00:12:55.814 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 00 00:12:55.813 READ LOG EXT
60 00 00 01 00 00 00 00 0d 5d 00 40 00 00:12:53.008 READ FPDMA QUEUED
60 00 00 01 00 00 00 00 09 54 00 40 00 00:12:52.796 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 18097 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 39 Celsius
Power Cycle Min/Max Temperature: 34/39 Celsius
Lifetime Min/Max Temperature: 8/59 Celsius
Under/Over Temperature Limit Count: 0/3
Vendor specific:
00 00 00 00 00 00 00 00 00 00 02 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 11 minutes
Min/Max recommended Temperature: 0/ 0 Celsius
Min/Max Temperature Limit: 0/ 0 Celsius
Temperature History Size (Index): 128 (58)
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS