mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 3084, modified: 0)
This commit is contained in:
153
HDD/Toshiba/MK2552/MK2552GSX/D27F32AE1781
Normal file
153
HDD/Toshiba/MK2552/MK2552GSX/D27F32AE1781
Normal file
@@ -0,0 +1,153 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Toshiba 2.5" HDD MK..52GSX
|
||||
Device Model: TOSHIBA MK2552GSX
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000039 ...
|
||||
Firmware Version: LV010J
|
||||
User Capacity: 250,059,350,016 bytes [250 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 1.5 Gb/s
|
||||
Local Time is: Fri Mar 5 22:19:18 2021 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Write SCT (Get) Feature Control Command failed: Read of ATA output registers not implemented [JMicron]
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 120) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 118) minutes.
|
||||
SCT capabilities: (0x0039) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 050 - 0
|
||||
3 Spin_Up_Time POS--K 100 100 001 - 1395
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 1015
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 050 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 050 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 050 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 566
|
||||
10 Spin_Retry_Count PO--CK 120 100 030 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 175
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 88
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 2800
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 25 (Min/Max 13/42)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 253 000 - 0
|
||||
220 Disk_Shift -O---- 100 100 000 - 12499
|
||||
222 Loaded_Hours -O--CK 100 100 000 - 35
|
||||
223 Load_Retry_Count -O--CK 100 100 000 - 0
|
||||
224 Load_Friction -O---K 100 100 000 - 0
|
||||
226 Load-in_Time -OS--K 100 100 000 - 235
|
||||
240 Head_Flying_Hours P----- 100 100 001 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented [JMicron]
|
||||
Read GP Log Directory failed
|
||||
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x80-0x9f SL R/W 16 Host vendor specific log
|
||||
0xe0 SL R/W 1 SCT Command/Status
|
||||
0xe1 SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 25 Celsius
|
||||
Power Cycle Min/Max Temperature: --/26 Celsius
|
||||
Lifetime Min/Max Temperature: --/42 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/55 Celsius
|
||||
Min/Max Temperature Limit: 5/55 Celsius
|
||||
Temperature History Size (Index): 478 (146)
|
||||
|
||||
Write SCT (Get) Error Recovery Control Command failed: Read of ATA output registers not implemented [JMicron]
|
||||
SCT (Get) Error Recovery Control command failed
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented [JMicron]
|
||||
Read SATA Phy Event Counters failed
|
||||
|
Reference in New Issue