smartctl 7.1 2019-12-30 r5022 [NetBSD 9.1 i386] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Protege
|
||||
Device Model: WDC WD200EB-00BHF0
|
||||
Serial Number: --
|
||||
Firmware Version: 15.15M15
|
||||
User Capacity: 20,019,314,176 bytes [20.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-5 (minor revision not indicated)
|
||||
Local Time is: Tue Nov 3 19:58:31 2020 EET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 1400) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x1b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
No Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
No General Purpose Logging support.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 22) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x000b 200 200 051 Pre-fail Always - 0
|
||||
3 Spin_Up_Time 0x0007 115 112 021 Pre-fail Always - 1616
|
||||
4 Start_Stop_Count 0x0032 096 096 040 Old_age Always - 4974
|
||||
5 Reallocated_Sector_Ct 0x0032 200 200 112 Old_age Always - 0
|
||||
7 Seek_Error_Rate 0x000b 200 200 051 Pre-fail Always - 0
|
||||
9 Power_On_Hours 0x0032 092 092 000 Old_age Always - 6561
|
||||
10 Spin_Retry_Count 0x0013 098 098 051 Pre-fail Always - 6
|
||||
11 Calibration_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0
|
||||
12 Power_Cycle_Count 0x0032 096 096 000 Old_age Always - 4636
|
||||
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
|
||||
197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0
|
||||
198 Offline_Uncorrectable 0x0012 200 200 000 Old_age Always - 0
|
||||
199 UDMA_CRC_Error_Count 0x000a 200 253 000 Old_age Always - 7
|
||||
200 Multi_Zone_Error_Rate 0x0009 200 200 051 Pre-fail Offline - 0
|
||||
|
||||
SMART Error Log Version: 1
|
||||
ATA Error Count: 3
|
||||
CR = Command Register [HEX]
|
||||
FR = Features Register [HEX]
|
||||
SC = Sector Count Register [HEX]
|
||||
SN = Sector Number Register [HEX]
|
||||
CL = Cylinder Low Register [HEX]
|
||||
CH = Cylinder High Register [HEX]
|
||||
DH = Device/Head Register [HEX]
|
||||
DC = Device Command Register [HEX]
|
||||
ER = Error register [HEX]
|
||||
ST = Status register [HEX]
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 3 occurred at disk power-on lifetime: 1064 hours (44 days + 8 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
10 51 01 3e 9f 54 e2
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
f9 00 01 3e 9f 54 e2 08 00:02:03.350 SET MAX ADDRESS [OBS-6]
|
||||
f8 00 00 3e 9f 54 e0 08 00:02:03.350 READ NATIVE MAX ADDRESS [OBS-ACS-3]
|
||||
f9 00 00 3e 9f 54 e2 08 00:02:03.200 SET MAX ADDRESS [OBS-6]
|
||||
f8 00 01 7f a7 54 e0 08 00:02:03.200 READ NATIVE MAX ADDRESS [OBS-ACS-3]
|
||||
c4 00 01 7f a7 54 e2 00 00:02:03.100 READ MULTIPLE
|
||||
|
||||
Error 2 occurred at disk power-on lifetime: 1064 hours (44 days + 8 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
10 51 01 3e 9f 54 e2
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
f9 00 01 3e 9f 54 e2 08 00:01:08.550 SET MAX ADDRESS [OBS-6]
|
||||
f8 00 00 3e 9f 54 e0 08 00:01:08.550 READ NATIVE MAX ADDRESS [OBS-ACS-3]
|
||||
f9 00 00 3e 9f 54 e2 08 00:01:08.400 SET MAX ADDRESS [OBS-6]
|
||||
f8 00 01 3e 9f 54 e0 08 00:01:08.400 READ NATIVE MAX ADDRESS [OBS-ACS-3]
|
||||
f9 00 01 3e 9f 54 e2 08 00:01:06.300 SET MAX ADDRESS [OBS-6]
|
||||
|
||||
Error 1 occurred at disk power-on lifetime: 1064 hours (44 days + 8 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
10 51 01 3e 9f 54 e2
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
f9 00 01 3e 9f 54 e2 08 00:01:06.300 SET MAX ADDRESS [OBS-6]
|
||||
f8 00 00 3e 9f 54 e0 08 00:01:06.300 READ NATIVE MAX ADDRESS [OBS-ACS-3]
|
||||
f9 00 00 3e 9f 54 e2 08 00:01:06.200 SET MAX ADDRESS [OBS-6]
|
||||
f8 00 01 7f a7 54 e0 08 00:01:06.200 READ NATIVE MAX ADDRESS [OBS-ACS-3]
|
||||
c4 00 01 7f a7 54 e2 00 00:01:06.050 READ MULTIPLE
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
Selective Self-tests/Logging not supported
|
||||
|