153
SSD/Corsair/CSSD-F80/CSSD-F80GBP2 90GB/F7223988D2DE
Normal file
153
SSD/Corsair/CSSD-F80/CSSD-F80GBP2 90GB/F7223988D2DE
Normal file
@@ -0,0 +1,153 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p15-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SandForce Driven SSDs
|
||||
Device Model: Corsair CSSD-F80GBP2
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000000 ...
|
||||
Firmware Version: 1.1
|
||||
User Capacity: 90,028,302,336 bytes [90.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Sat Apr 17 18:42:29 2021 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unknown (0x100)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7f) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Abort Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 48) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 118 118 050 - 0/206054587
|
||||
5 Retired_Block_Count PO--CK 083 083 003 - 2160
|
||||
9 Power_On_Hours_and_Msec -O--CK 100 100 000 - 24538h+20m+11.950s
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1596
|
||||
171 Program_Fail_Count ------ 000 000 000 - 0
|
||||
172 Erase_Fail_Count ------ 000 000 000 - 0
|
||||
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 113
|
||||
177 Wear_Range_Delta ------ 000 000 --- - 2
|
||||
181 Program_Fail_Count ------ 000 000 000 - 0
|
||||
182 Erase_Fail_Count ------ 000 000 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 000 000 000 - 0
|
||||
195 ECC_Uncorr_Error_Count --SRC- 118 118 000 - 0/206054587
|
||||
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
|
||||
231 SSD_Life_Left PO--C- 075 075 010 - 1
|
||||
233 SandForce_Internal ------ 000 000 000 - 8256
|
||||
234 SandForce_Internal ------ 000 000 000 - 13440
|
||||
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 13440
|
||||
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 19904
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xb7 GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log not supported
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: ? Celsius
|
||||
Power Cycle Min/Max Temperature: 127/-127 Celsius
|
||||
Lifetime Min/Max Temperature: 0/ 0 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 478 (479)
|
||||
Invalid Temperature History Size or Index
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 256 (25.6 seconds)
|
||||
Write: 256 (25.6 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 45 Device-to-host register FISes sent due to a COMRESET
|
||||
|
123
SSD/Corsair/CSSD-V64/CSSD-V64GB2/FCF9BE744F0A
Normal file
123
SSD/Corsair/CSSD-V64/CSSD-V64GB2/FCF9BE744F0A
Normal file
@@ -0,0 +1,123 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RC3 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Indilinx Barefoot based SSDs
|
||||
Device Model: Corsair CSSD-V64GB2
|
||||
Serial Number: --
|
||||
Firmware Version: 2.2
|
||||
User Capacity: 64,023,257,088 bytes [64.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
Local Time is: Thu Mar 25 20:02:17 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x1d) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Abort Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
No Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x00) Error logging NOT supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 0) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 0) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ --- --- --- - 5
|
||||
9 Power_On_Hours ------ --- --- --- - 5318
|
||||
12 Power_Cycle_Count ------ --- --- --- - 1734
|
||||
184 Initial_Bad_Block_Count ------ --- --- --- - 19
|
||||
195 Program_Failure_Blk_Ct ------ --- --- --- - 0
|
||||
196 Erase_Failure_Blk_Ct ------ --- --- --- - 0
|
||||
197 Read_Failure_Blk_Ct ------ --- --- --- - 0
|
||||
198 Read_Sectors_Tot_Ct ------ --- --- --- - 11150691263
|
||||
199 Write_Sectors_Tot_Ct ------ --- --- --- - 5661751124
|
||||
200 Read_Commands_Tot_Ct ------ --- --- --- - 216654495
|
||||
201 Write_Commands_Tot_Ct ------ --- --- --- - 99617452
|
||||
202 Error_Bits_Flash_Tot_Ct ------ --- --- --- - 68544080
|
||||
203 Corr_Read_Errors_Tot_Ct ------ --- --- --- - 59061648
|
||||
204 Bad_Block_Full_Flag ------ --- --- --- - 0
|
||||
205 Max_PE_Count_Spec ------ --- --- --- - 5000
|
||||
206 Min_Erase_Count ------ --- --- --- - 2427
|
||||
207 Max_Erase_Count ------ --- --- --- - 4572
|
||||
208 Average_Erase_Count ------ --- --- --- - 3451
|
||||
209 Remaining_Lifetime_Perc ------ --- --- --- - 31
|
||||
211 SATA_Error_Ct_CRC ------ --- --- --- - 0
|
||||
212 SATA_Error_Ct_Handshake ------ --- --- --- - 0
|
||||
213 Indilinx_Internal ------ --- --- --- - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 77 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0xa0 GPL VS 4096 Device vendor specific log
|
||||
|
||||
Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum.
|
||||
SMART Extended Comprehensive Error Log Version: 49 (77 sectors)
|
||||
No Errors Logged
|
||||
|
||||
Warning! SMART Extended Self-test Log Structure error: invalid SMART checksum.
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
Selective Self-tests/Logging not supported
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
[Reserved: 0x00 0x00 0x41 0x00]
|
||||
ID Size Value Description
|
||||
0x0d50 6 81933 Unknown
|
||||
|
167
SSD/Corsair/Force 3/Force 3 SSD 120GB/08C8E5FF5E87
Normal file
167
SSD/Corsair/Force 3/Force 3 SSD 120GB/08C8E5FF5E87
Normal file
@@ -0,0 +1,167 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SandForce Driven SSDs
|
||||
Device Model: Corsair Force 3 SSD
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 0 000000 ...
|
||||
Firmware Version: 5.07
|
||||
User Capacity: 120,034,123,776 bytes [120 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Feb 6 18:33:10 2021 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 48) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x0021) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 120 120 050 - 0/0
|
||||
5 Retired_Block_Count PO--CK 100 100 003 - 1
|
||||
9 Power_On_Hours_and_Msec -O--CK 049 049 000 - 45028h+55m+17.070s
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 530
|
||||
171 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 327
|
||||
177 Wear_Range_Delta ------ 000 000 000 - 8
|
||||
181 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
182 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 000 000 000 - 15255
|
||||
194 Temperature_Celsius -O---K 030 030 000 - 30 (Min/Max 30/30)
|
||||
195 ECC_Uncorr_Error_Count --SRC- 100 100 000 - 0/0
|
||||
196 Reallocated_Event_Count PO--CK 100 100 003 - 1
|
||||
201 Unc_Soft_Read_Err_Rate --SRC- 100 100 000 - 0/0
|
||||
204 Soft_ECC_Correct_Rate --SRC- 100 100 000 - 0/0
|
||||
230 Life_Curve_Status PO--C- 100 100 000 - 100
|
||||
231 SSD_Life_Left PO--C- 099 099 010 - 0
|
||||
233 SandForce_Internal ------ 000 000 000 - 18927
|
||||
234 SandForce_Internal -O--CK 000 000 000 - 18795
|
||||
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 18795
|
||||
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 22124
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xb7 GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log not supported
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/30 Celsius
|
||||
Lifetime Min/Max Temperature: 30/30 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 0 minutes
|
||||
Temperature Logging Interval: 0 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 478 (1)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 35 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 32 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
184
SSD/Corsair/Force 3/Force 3 SSD 120GB/85117BAC2620
Normal file
184
SSD/Corsair/Force 3/Force 3 SSD 120GB/85117BAC2620
Normal file
@@ -0,0 +1,184 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p13-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SandForce Driven SSDs
|
||||
Device Model: Corsair Force 3 SSD
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 0 000000 ...
|
||||
Firmware Version: 5.07
|
||||
User Capacity: 120,034,123,776 bytes [120 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Mar 9 09:59:58 2021 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 48) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x0021) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 102 102 050 - 0/6056823
|
||||
5 Retired_Block_Count PO--CK 100 100 003 - 1
|
||||
9 Power_On_Hours_and_Msec -O--CK 079 079 000 - 19264h+33m+08.470s
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1887
|
||||
171 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 496
|
||||
177 Wear_Range_Delta ------ 000 000 000 - 4
|
||||
181 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
182 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 030 030 000 - 30 (Min/Max 30/30)
|
||||
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/6056823
|
||||
196 Reallocated_Event_Count PO--CK 100 100 003 - 1
|
||||
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/6056823
|
||||
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/6056823
|
||||
230 Life_Curve_Status PO--C- 100 100 000 - 100
|
||||
231 SSD_Life_Left PO--C- 087 087 010 - 0
|
||||
233 SandForce_Internal ------ 000 000 000 - 61668
|
||||
234 SandForce_Internal -O--CK 000 000 000 - 13248
|
||||
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 13248
|
||||
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 35857
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x04 GPL,SL R/O 1 Device Statistics log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xb7 GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log not supported
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/30 Celsius
|
||||
Lifetime Min/Max Temperature: 30/30 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 0 minutes
|
||||
Temperature Logging Interval: 0 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 478 (1)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 1887 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 19264 --- Power-on Hours
|
||||
0x01 0x018 6 27784347294 --- Logical Sectors Written
|
||||
0x01 0x028 6 75198455325 --- Logical Sectors Read
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 18214 --- Resets Between Cmd Acceptance and Completion
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 18214 --- Number of Hardware Resets
|
||||
0x06 0x010 4 14816 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 255 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 19 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
166
SSD/Corsair/Force 3/Force 3 SSD 240GB/4DDAAC055BFC
Normal file
166
SSD/Corsair/Force 3/Force 3 SSD 240GB/4DDAAC055BFC
Normal file
@@ -0,0 +1,166 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SandForce Driven SSDs
|
||||
Device Model: Corsair Force 3 SSD
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 0 000000 ...
|
||||
Firmware Version: 5.02
|
||||
User Capacity: 240,057,409,536 bytes [240 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Jan 31 01:46:43 2021 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 48) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x0021) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 120 120 050 - 0/0
|
||||
5 Retired_Block_Count PO--CK 100 100 003 - 0
|
||||
9 Power_On_Hours_and_Msec -O--CK 000 000 000 - 60604h+44m+04.060s
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 119
|
||||
171 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 65
|
||||
177 Wear_Range_Delta ------ 000 000 000 - 9
|
||||
181 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
182 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 128 129 000 - 128 (0 127 0 129 0)
|
||||
195 ECC_Uncorr_Error_Count --SRC- 100 100 000 - 0/0
|
||||
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
|
||||
201 Unc_Soft_Read_Err_Rate --SRC- 100 100 000 - 0/0
|
||||
204 Soft_ECC_Correct_Rate --SRC- 100 100 000 - 0/0
|
||||
230 Life_Curve_Status PO--C- 100 100 000 - 100
|
||||
231 SSD_Life_Left PO--C- 100 100 010 - 0
|
||||
233 SandForce_Internal ------ 000 000 000 - 19646
|
||||
234 SandForce_Internal -O--CK 000 000 000 - 7930
|
||||
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 7930
|
||||
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 5553
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xb7 GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log not supported
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: ? Celsius
|
||||
Power Cycle Min/Max Temperature: 127/-127 Celsius
|
||||
Lifetime Min/Max Temperature: 0/ 0 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 10 (Unknown, should be 2)
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 62/117 Celsius
|
||||
Min/Max Temperature Limit: -20/-55 Celsius
|
||||
Temperature History Size (Index): 48384 (232)
|
||||
Invalid Temperature History Size or Index
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
167
SSD/Corsair/Force 3/Force 3 SSD 64GB/E13E01A138DB
Normal file
167
SSD/Corsair/Force 3/Force 3 SSD 64GB/E13E01A138DB
Normal file
@@ -0,0 +1,167 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SandForce Driven SSDs
|
||||
Device Model: Corsair Force 3 SSD
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 0 000000 ...
|
||||
Firmware Version: 1.2
|
||||
User Capacity: 60,022,480,896 bytes [60.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 T13/2015-D revision 3
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon Apr 5 23:03:15 2021 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7f) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Abort Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 48) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x0021) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 120 120 050 - 0/0
|
||||
5 Retired_Block_Count PO--CK 100 100 003 - 0
|
||||
9 Power_On_Hours_and_Msec -O--CK 093 093 000 - 6936h+13m+29.240s
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3531
|
||||
171 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 22
|
||||
177 Wear_Range_Delta ------ 000 000 000 - 12
|
||||
181 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
182 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 128 129 000 - 128 (0 127 0 129 0)
|
||||
195 ECC_Uncorr_Error_Count --SRC- 100 100 000 - 0/0
|
||||
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
|
||||
201 Unc_Soft_Read_Err_Rate --SRC- 100 100 000 - 0/0
|
||||
204 Soft_ECC_Correct_Rate --SRC- 100 100 000 - 0/0
|
||||
230 Life_Curve_Status PO--C- 100 100 000 - 429496729700
|
||||
231 SSD_Life_Left PO--C- 097 097 010 - 0
|
||||
233 SandForce_Internal ------ 000 000 000 - 11066
|
||||
234 SandForce_Internal -O--CK 000 000 000 - 14249
|
||||
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 14249
|
||||
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 20897
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xb7 GPL,SL VS 16 Device vendor specific log
|
||||
0xd0 GPL VS 65535 Device vendor specific log
|
||||
0xd0 SL VS 255 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log not supported
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: ? Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 478 (1)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 4 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 0 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x0002 4 0 R_ERR response for data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
|
165
SSD/Corsair/Force 3/Force 3 SSD 64GB/EAD75B6C99D7
Normal file
165
SSD/Corsair/Force 3/Force 3 SSD 64GB/EAD75B6C99D7
Normal file
@@ -0,0 +1,165 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p15-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SandForce Driven SSDs
|
||||
Device Model: Corsair Force 3 SSD
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 0 000000 ...
|
||||
Firmware Version: 5.03
|
||||
User Capacity: 60,022,480,896 bytes [60.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Apr 7 20:58:28 2021 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 48) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x0021) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 120 120 050 - 0/0
|
||||
5 Retired_Block_Count PO--CK 100 100 003 - 0
|
||||
9 Power_On_Hours_and_Msec -O--CK 000 000 000 - 23718h+39m+05.890s
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 292
|
||||
171 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 239
|
||||
177 Wear_Range_Delta ------ 000 000 000 - 3
|
||||
181 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
182 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 030 030 000 - 30 (Min/Max 30/30)
|
||||
195 ECC_Uncorr_Error_Count --SRC- 100 100 000 - 0/0
|
||||
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
|
||||
201 Unc_Soft_Read_Err_Rate --SRC- 100 100 000 - 0/0
|
||||
204 Soft_ECC_Correct_Rate --SRC- 100 100 000 - 0/0
|
||||
230 Life_Curve_Status PO--C- 100 100 000 - 100
|
||||
231 SSD_Life_Left PO--C- 100 100 010 - 0
|
||||
233 SandForce_Internal ------ 000 000 000 - 5149
|
||||
234 SandForce_Internal -O--CK 000 000 000 - 3209
|
||||
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 3209
|
||||
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 4001
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xb7 GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log not supported
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/30 Celsius
|
||||
Lifetime Min/Max Temperature: 30/30 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 0 minutes
|
||||
Temperature Logging Interval: 0 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 478 (1)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 18 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 13 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
185
SSD/Corsair/Force GS/Force GS 128GB/CDFAB122E20F
Normal file
185
SSD/Corsair/Force GS/Force GS 128GB/CDFAB122E20F
Normal file
@@ -0,0 +1,185 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SandForce Driven SSDs
|
||||
Device Model: Corsair Force GS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 0 000000 ...
|
||||
Firmware Version: 5.05A
|
||||
User Capacity: 128,035,676,160 bytes [128 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Feb 4 12:59:46 2021 EET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 48) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x0021) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 119 119 050 - 0/234699528
|
||||
5 Retired_Block_Count PO--CK 100 100 003 - 0
|
||||
9 Power_On_Hours_and_Msec -O--CK 038 038 000 - 54608h+23m+50.250s
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2139
|
||||
171 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 202
|
||||
177 Wear_Range_Delta ------ 000 000 000 - 6
|
||||
181 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
182 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 038 058 000 - 38 (Min/Max 15/58)
|
||||
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/234699528
|
||||
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
|
||||
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/234699528
|
||||
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/234699528
|
||||
230 Life_Curve_Status PO--C- 100 100 000 - 100
|
||||
231 SSD_Life_Left PO--C- 092 092 010 - 0
|
||||
233 SandForce_Internal ------ 000 000 000 - 44770
|
||||
234 SandForce_Internal -O--CK 000 000 000 - 70885
|
||||
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 70885
|
||||
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 10269
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x04 GPL,SL R/O 1 Device Statistics log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xb7 GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log not supported
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/44 Celsius
|
||||
Lifetime Min/Max Temperature: 15/58 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 0 (Unknown, should be 2)
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 0 (63)
|
||||
Temperature History is empty
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 2139 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 54608 --- Power-on Hours
|
||||
0x01 0x018 6 148657837274 --- Logical Sectors Written
|
||||
0x01 0x028 6 21537631661 --- Logical Sectors Read
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 11819 --- Resets Between Cmd Acceptance and Completion
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 11819 --- Number of Hardware Resets
|
||||
0x06 0x010 4 10794 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 255 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 193 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 147 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
187
SSD/Corsair/Force GS/Force GS 180GB/6CC9B357A66C
Normal file
187
SSD/Corsair/Force GS/Force GS 180GB/6CC9B357A66C
Normal file
@@ -0,0 +1,187 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SandForce Driven SSDs
|
||||
Device Model: Corsair Force GS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 0 000000 ...
|
||||
Firmware Version: 5.05A
|
||||
User Capacity: 180,045,766,656 bytes [180 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Feb 2 07:50:44 2021 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 48) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x0021) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 099 099 050 - 0/2447149
|
||||
5 Retired_Block_Count PO--CK 100 100 003 - 0
|
||||
9 Power_On_Hours_and_Msec -O--CK 078 078 000 - 19371h+26m+03.160s
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1382
|
||||
171 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 650
|
||||
177 Wear_Range_Delta ------ 000 000 000 - 2
|
||||
181 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
182 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 034 043 000 - 34 (Min/Max 12/43)
|
||||
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/2447149
|
||||
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
|
||||
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/2447149
|
||||
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/2447149
|
||||
230 Life_Curve_Status PO--C- 100 100 000 - 100
|
||||
231 SSD_Life_Left PO--C- 100 100 010 - 0
|
||||
233 SandForce_Internal ------ 000 000 000 - 2581
|
||||
234 SandForce_Internal -O--CK 000 000 000 - 2437
|
||||
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 2437
|
||||
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 2110
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x04 GPL,SL R/O 1 Device Statistics log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xb7 GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log not supported
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/35 Celsius
|
||||
Lifetime Min/Max Temperature: 12/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 0 (Unknown, should be 2)
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 0 (98)
|
||||
Temperature History is empty
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 1382 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 19371 --- Power-on Hours
|
||||
0x01 0x018 6 5112012633 --- Logical Sectors Written
|
||||
0x01 0x028 6 4426128047 --- Logical Sectors Read
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 5027 --- Resets Between Cmd Acceptance and Completion
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 5027 --- Number of Hardware Resets
|
||||
0x06 0x010 4 3303 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 255 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 26 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
168
SSD/Corsair/Force GT/Force GT 240GB/716C7017465A
Normal file
168
SSD/Corsair/Force GT/Force GT 240GB/716C7017465A
Normal file
@@ -0,0 +1,168 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SandForce Driven SSDs
|
||||
Device Model: Corsair Force GT
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 0 000000 ...
|
||||
Firmware Version: 5.05
|
||||
User Capacity: 240,057,409,536 bytes [240 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jan 19 11:25:34 2021 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 48) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x0021) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 102 102 050 - 0/6469716
|
||||
5 Retired_Block_Count PO--CK 100 100 003 - 0
|
||||
9 Power_On_Hours_and_Msec -O--CK 046 046 000 - 47991h+07m+54.780s
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 483
|
||||
171 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 161
|
||||
177 Wear_Range_Delta ------ 000 000 000 - 0
|
||||
181 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
182 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 031 066 000 - 31 (Min/Max 16/66)
|
||||
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/6469716
|
||||
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
|
||||
201 Unc_Soft_Read_Err_Rate --SRC- 120 120 000 - 0/6469716
|
||||
204 Soft_ECC_Correct_Rate --SRC- 120 120 000 - 0/6469716
|
||||
230 Life_Curve_Status PO--C- 100 100 000 - 100
|
||||
231 SSD_Life_Left PO--C- 100 100 010 - 0
|
||||
233 SandForce_Internal ------ 000 000 000 - 2626
|
||||
234 SandForce_Internal -O--CK 000 000 000 - 3412
|
||||
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 3412
|
||||
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 3567
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xb7 GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log not supported
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/33 Celsius
|
||||
Lifetime Min/Max Temperature: 16/66 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 10 (Unknown, should be 2)
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: -59/115 Celsius
|
||||
Min/Max Temperature Limit: -14/-47 Celsius
|
||||
Temperature History Size (Index): 1077 (117)
|
||||
Invalid Temperature History Size or Index
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 16 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 17 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
232
SSD/Corsair/Neutron GTX SSD/Neutron GTX SSD 120GB/645B889DF87C
Normal file
232
SSD/Corsair/Neutron GTX SSD/Neutron GTX SSD 120GB/645B889DF87C
Normal file
@@ -0,0 +1,232 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p4 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: Corsair Neutron GTX SSD
|
||||
Serial Number: --
|
||||
Firmware Version: M312
|
||||
User Capacity: 120,034,123,776 bytes [120 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.5, 6.0 Gb/s
|
||||
Local Time is: Thu Apr 29 12:59:36 2021 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x02) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 3) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x19) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
No Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
No General Purpose Logging support.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 0
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate -OSR-- 166 166 006 - 0
|
||||
5 Reallocated_Sector_Ct -O--CK 099 099 036 - 149
|
||||
9 Power_On_Hours -O--CK 082 082 000 - 16277
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 5709
|
||||
171 Unknown_Attribute -O--CK 253 253 000 - 0
|
||||
172 Unknown_Attribute -O--CK 100 100 000 - 152
|
||||
181 Program_Fail_Cnt_Total -O--CK 253 253 000 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 000 - 152
|
||||
194 Temperature_Celsius -O---- 036 000 000 - 36 (Min/Max 14/48)
|
||||
201 Unknown_SSD_Attribute -OSR-- 100 100 000 - 0
|
||||
204 Soft_ECC_Correction -OSR-- 100 100 000 - 0
|
||||
231 Unknown_SSD_Attribute PO--CK 090 090 010 - 11
|
||||
234 Unknown_Attribute -O--CK 100 100 000 - 61626
|
||||
241 Total_LBAs_Written -O--CK 100 100 000 - 9324
|
||||
242 Total_LBAs_Read -O--CK 100 100 000 - 10291
|
||||
250 Read_Error_Retry_Rate -O--CK 100 100 000 - 184498
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory not supported
|
||||
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 4 Comprehensive SMART error log
|
||||
0x03 SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log Version: 1
|
||||
ATA Error Count: 23323 (device log contains only the most recent five errors)
|
||||
CR = Command Register [HEX]
|
||||
FR = Features Register [HEX]
|
||||
SC = Sector Count Register [HEX]
|
||||
SN = Sector Number Register [HEX]
|
||||
CL = Cylinder Low Register [HEX]
|
||||
CH = Cylinder High Register [HEX]
|
||||
DH = Device/Head Register [HEX]
|
||||
DC = Device Command Register [HEX]
|
||||
ER = Error register [HEX]
|
||||
ST = Status register [HEX]
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 23323 occurred at disk power-on lifetime: 16277 hours (678 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
04 51 00 00 4f c2 e0 Error: ABRT
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
b0 d5 81 04 4f c2 40 40 05:38:07.770 SMART READ LOG
|
||||
b0 d5 01 04 4f c2 40 40 05:38:07.770 SMART READ LOG
|
||||
b0 d5 01 06 4f c2 40 40 05:38:07.770 SMART READ LOG
|
||||
b0 d5 01 01 4f c2 40 40 05:38:07.770 SMART READ LOG
|
||||
b0 d5 01 00 4f c2 40 40 05:38:07.770 SMART READ LOG
|
||||
|
||||
Error 23322 occurred at disk power-on lifetime: 16277 hours (678 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
04 51 00 00 4f c2 e0 Error: ABRT
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
b0 d5 81 04 4f c2 40 40 05:37:39.640 SMART READ LOG
|
||||
b0 d5 01 04 4f c2 40 40 05:37:39.640 SMART READ LOG
|
||||
b0 d5 01 06 4f c2 40 40 05:37:39.640 SMART READ LOG
|
||||
b0 d5 01 01 4f c2 40 40 05:37:39.640 SMART READ LOG
|
||||
b0 d5 01 00 4f c2 40 40 05:37:39.640 SMART READ LOG
|
||||
|
||||
Error 23321 occurred at disk power-on lifetime: 16277 hours (678 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
04 51 00 00 4f c2 e0 Error: ABRT
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
b0 d5 81 04 4f c2 40 40 05:35:55.150 SMART READ LOG
|
||||
b0 d5 01 04 4f c2 40 40 05:35:55.150 SMART READ LOG
|
||||
b0 d5 01 06 4f c2 40 40 05:35:55.150 SMART READ LOG
|
||||
b0 d5 01 01 4f c2 40 40 05:35:55.150 SMART READ LOG
|
||||
b0 d5 01 00 4f c2 40 40 05:35:55.150 SMART READ LOG
|
||||
|
||||
Error 23320 occurred at disk power-on lifetime: 16272 hours (678 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
01 50 01 01 00 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
00 00 00 00 00 00 00 00 00:01:15.230 NOP [Abort queued commands]
|
||||
00 00 00 00 00 00 00 00 00:01:15.240 NOP [Abort queued commands]
|
||||
00 00 00 00 00 00 00 00 00:01:15.220 NOP [Abort queued commands]
|
||||
00 00 00 00 00 00 00 00 00:01:15.230 NOP [Abort queued commands]
|
||||
25 00 08 a8 4b f9 e0 e0 00:00:58.300 READ DMA EXT
|
||||
|
||||
Error 23319 occurred at disk power-on lifetime: 16272 hours (678 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
01 50 01 01 00 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
00 00 00 00 00 00 00 00 00:01:15.220 NOP [Abort queued commands]
|
||||
00 00 00 00 00 00 00 00 00:01:15.230 NOP [Abort queued commands]
|
||||
25 00 08 a8 4b f9 e0 e0 00:00:58.300 READ DMA EXT
|
||||
25 00 01 af 4b f9 e0 e0 00:00:58.300 READ DMA EXT
|
||||
25 00 20 02 00 00 e0 e0 00:00:58.300 READ DMA EXT
|
||||
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 451 -
|
||||
|
||||
Selective Self-tests/Logging not supported
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (SMART Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
ATA_SMART_READ_LOG failed: Input/output error
|
||||
Read Device Statistics pages 0x00-0x80 failed
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 11 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
|
@@ -4,6 +4,12 @@ Corsair Solid State Drives
|
||||
This is a list of all tested Corsair solid state drive models and their MTBFs. See
|
||||
more info on reliability test in the [README](https://github.com/bsdhw/SMART).
|
||||
|
||||
Contents
|
||||
--------
|
||||
|
||||
1. [ SSD by Model ](#ssd-by-model)
|
||||
2. [ SSD by Family ](#ssd-by-family)
|
||||
|
||||
SSD by Model
|
||||
------------
|
||||
|
||||
@@ -11,11 +17,37 @@ Please take all columns into account when reading the table. Pay attention on th
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Model | Size | Samples | Days | Err | MTBF |
|
||||
|-----------|--------------------|--------|---------|-------|-------|--------|
|
||||
| Corsair | Force 3 SSD | 240 GB | 1 | 2525 | 0 | 6.92 |
|
||||
| Corsair | Force GS | 128 GB | 1 | 2275 | 0 | 6.23 |
|
||||
| Corsair | Force GT | 240 GB | 1 | 1999 | 0 | 5.48 |
|
||||
| Corsair | Force 3 SSD | 180 GB | 1 | 2530 | 2 | 2.31 |
|
||||
| Corsair | Force GS | 180 GB | 1 | 807 | 0 | 2.21 |
|
||||
| Corsair | Force 3 SSD | 64 GB | 2 | 638 | 0 | 1.75 |
|
||||
| Corsair | CSSD-V64GB2 | 64 GB | 1 | 221 | 0 | 0.61 |
|
||||
| Corsair | Force LS SSD | 64 GB | 2 | 217 | 0 | 0.60 |
|
||||
| Corsair | Force 3 SSD | 120 GB | 2 | 1339 | 507 | 0.37 |
|
||||
| Corsair | Neutron GTX SSD | 120 GB | 1 | 678 | 149 | 0.01 |
|
||||
| Corsair | CSSD-F80GBP2 | 90 GB | 1 | 1022 | 1008 | 0.00 |
|
||||
|
||||
SSD by Family
|
||||
-------------
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Family | Models | Samples | Days | Err | MTBF |
|
||||
|-----------|------------------------|--------|---------|-------|-------|--------|
|
||||
| Corsair | SandForce Driven SSDs | 9 | 12 | 1296 | 169 | 2.38 |
|
||||
| Corsair | Indilinx Barefoot b... | 1 | 1 | 221 | 0 | 0.61 |
|
||||
| Corsair | Unknown | 1 | 1 | 678 | 149 | 0.01 |
|
||||
|
Reference in New Issue