1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 3084, modified: 0)

This commit is contained in:
Andrey Ponomarenko
2021-05-18 23:01:35 +03:00
parent 8bb6808886
commit d96e63400c
3224 changed files with 547026 additions and 1866 deletions

View File

@@ -0,0 +1,219 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p9 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 11/1300 SSDs
Device Model: Micron_M500_MTFDDAK960MAV
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: MU02
User Capacity: 960,197,124,096 bytes [960 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Dec 16 10:38:21 2020 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (10235) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 74) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 100 100 --- - 63
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 --- - 0
9 Power_On_Hours -O--CK 100 100 --- - 38128
12 Power_Cycle_Count -O--CK 100 100 --- - 71
170 Reserved_Block_Count -O--CK 100 100 --- - 16
171 Program_Fail_Count -O--CK 100 100 --- - 0
172 Erase_Fail_Count -O--CK 100 100 --- - 0
173 Ave_Block-Erase_Count -O--CK 099 099 --- - 47
174 Unexpect_Power_Loss_Ct -O--CK 100 100 --- - 33
181 Program_Fail_Cnt_Total -O---K 100 100 --- - 631365828669
183 SATA_Interfac_Downshift -O--CK 100 100 --- - 0
184 Error_Correction_Count -O--CK 100 100 --- - 0
187 Reported_Uncorrect -O--CK 100 100 --- - 0
188 Command_Timeout -O--CK 100 100 --- - 103
194 Temperature_Celsius -O---K 065 051 --- - 35 (Min/Max 16/49)
195 Cumulativ_Corrected_ECC -O-RCK 100 100 --- - 4294967295
196 Reallocated_Event_Count -O--CK 100 100 --- - 16
197 Current_Pending_Sector -O--CK 100 100 --- - 0
198 Offline_Uncorrectable ----CK 100 100 --- - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 --- - 0
202 Percent_Lifetime_Remain P---CK 099 099 --- - 1
206 Write_Error_Rate -OSR-- 100 100 --- - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 255 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 429 Current Device Internal Status Data log
0x25 GPL R/O 145 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 2000 Device vendor specific log
0xa0 SL VS 208 Device vendor specific log
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 80 Device vendor specific log
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 38128 -
# 2 Vendor (0xff) Completed without error 00% 38101 -
# 3 Vendor (0xff) Completed without error 00% 38089 -
# 4 Vendor (0xff) Completed without error 00% 38074 -
# 5 Vendor (0xff) Completed without error 00% 38062 -
# 6 Vendor (0xff) Completed without error 00% 38048 -
# 7 Vendor (0xff) Completed without error 00% 38033 -
# 8 Vendor (0xff) Completed without error 00% 38018 -
# 9 Vendor (0xff) Completed without error 00% 38005 -
#10 Vendor (0xff) Completed without error 00% 37992 -
#11 Vendor (0xff) Completed without error 00% 37978 -
#12 Vendor (0xff) Completed without error 00% 37965 -
#13 Vendor (0xff) Completed without error 00% 37949 -
#14 Vendor (0xff) Completed without error 00% 37936 -
#15 Vendor (0xff) Completed without error 00% 37922 -
#16 Vendor (0xff) Completed without error 00% 37908 -
#17 Vendor (0xff) Completed without error 00% 37895 -
#18 Vendor (0xff) Completed without error 00% 37882 -
#19 Vendor (0xff) Completed without error 00% 37867 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: -80/80 Celsius
Lifetime Min/Max Temperature: -80/80 Celsius
Under/Over Temperature Limit Count: 3/1
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (448)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 71 --- Lifetime Power-On Resets
0x01 0x010 4 38128 --- Power-on Hours
0x01 0x018 6 47143999377 --- Logical Sectors Written
0x01 0x020 6 82152688 --- Number of Write Commands
0x01 0x028 6 10303854314899 --- Logical Sectors Read
0x01 0x030 6 9957789589 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 103 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 35 --- Current Temperature
0x05 0x010 1 34 --- Average Short Term Temperature
0x05 0x018 1 42 --- Average Long Term Temperature
0x05 0x020 1 127 --- Highest Temperature
0x05 0x028 1 -125 --- Lowest Temperature
0x05 0x030 1 45 --- Highest Average Short Term Temperature
0x05 0x038 1 20 --- Lowest Average Short Term Temperature
0x05 0x040 1 43 --- Highest Average Long Term Temperature
0x05 0x048 1 21 --- Lowest Average Long Term Temperature
0x05 0x050 4 43 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 73 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 0 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 3 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,219 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p9 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 11/1300 SSDs
Device Model: Micron_M500_MTFDDAK960MAV
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: MU02
User Capacity: 960,197,124,096 bytes [960 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Dec 16 10:38:22 2020 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1570) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 74) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 100 100 --- - 172
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 --- - 0
9 Power_On_Hours -O--CK 100 100 --- - 38138
12 Power_Cycle_Count -O--CK 100 100 --- - 60
170 Reserved_Block_Count -O--CK 100 100 --- - 16
171 Program_Fail_Count -O--CK 100 100 --- - 0
172 Erase_Fail_Count -O--CK 100 100 --- - 0
173 Ave_Block-Erase_Count -O--CK 099 099 --- - 44
174 Unexpect_Power_Loss_Ct -O--CK 100 100 --- - 25
181 Program_Fail_Cnt_Total -O---K 100 100 --- - 502516154408
183 SATA_Interfac_Downshift -O--CK 100 100 --- - 0
184 Error_Correction_Count -O--CK 100 100 --- - 0
187 Reported_Uncorrect -O--CK 100 100 --- - 0
188 Command_Timeout -O--CK 100 100 --- - 93
194 Temperature_Celsius -O---K 067 051 --- - 33 (Min/Max 21/49)
195 Cumulativ_Corrected_ECC -O-RCK 100 100 --- - 4294967295
196 Reallocated_Event_Count -O--CK 100 100 --- - 16
197 Current_Pending_Sector -O--CK 100 100 --- - 0
198 Offline_Uncorrectable ----CK 100 100 --- - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 --- - 0
202 Percent_Lifetime_Remain P---CK 099 099 --- - 1
206 Write_Error_Rate -OSR-- 100 100 --- - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 255 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 429 Current Device Internal Status Data log
0x25 GPL R/O 145 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 2000 Device vendor specific log
0xa0 SL VS 208 Device vendor specific log
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 80 Device vendor specific log
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 38132 -
# 2 Vendor (0xff) Completed without error 00% 38119 -
# 3 Vendor (0xff) Completed without error 00% 38104 -
# 4 Vendor (0xff) Completed without error 00% 38091 -
# 5 Vendor (0xff) Completed without error 00% 38078 -
# 6 Vendor (0xff) Completed without error 00% 38065 -
# 7 Vendor (0xff) Completed without error 00% 38051 -
# 8 Vendor (0xff) Completed without error 00% 38039 -
# 9 Vendor (0xff) Completed without error 00% 38025 -
#10 Vendor (0xff) Completed without error 00% 38011 -
#11 Vendor (0xff) Completed without error 00% 37998 -
#12 Vendor (0xff) Completed without error 00% 37984 -
#13 Vendor (0xff) Completed without error 00% 37971 -
#14 Vendor (0xff) Completed without error 00% 37958 -
#15 Vendor (0xff) Completed without error 00% 37944 -
#16 Vendor (0xff) Completed without error 00% 37930 -
#17 Vendor (0xff) Completed without error 00% 37916 -
#18 Vendor (0xff) Completed without error 00% 37902 -
#19 Vendor (0xff) Completed without error 00% 37887 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: -85/90 Celsius
Lifetime Min/Max Temperature: -85/90 Celsius
Under/Over Temperature Limit Count: 2/1
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (127)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 60 --- Lifetime Power-On Resets
0x01 0x010 4 38138 --- Power-on Hours
0x01 0x018 6 42854935346 --- Logical Sectors Written
0x01 0x020 6 81517179 --- Number of Write Commands
0x01 0x028 6 8459628190908 --- Logical Sectors Read
0x01 0x030 6 8321422270 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 93 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 33 --- Current Temperature
0x05 0x010 1 33 --- Average Short Term Temperature
0x05 0x018 1 39 --- Average Long Term Temperature
0x05 0x020 1 111 --- Highest Temperature
0x05 0x028 1 -125 --- Lowest Temperature
0x05 0x030 1 42 --- Highest Average Short Term Temperature
0x05 0x038 1 21 --- Lowest Average Short Term Temperature
0x05 0x040 1 40 --- Highest Average Long Term Temperature
0x05 0x048 1 21 --- Lowest Average Long Term Temperature
0x05 0x050 4 41 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 80 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 0 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 2 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,219 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p9 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 11/1300 SSDs
Device Model: Micron_M500_MTFDDAK960MAV
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: MU02
User Capacity: 960,197,124,096 bytes [960 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Dec 16 10:38:23 2020 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 2160) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 74) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 100 100 --- - 458
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 --- - 49152
9 Power_On_Hours -O--CK 100 100 --- - 43284
12 Power_Cycle_Count -O--CK 100 100 --- - 63
170 Reserved_Block_Count -O--CK 100 100 --- - 19
171 Program_Fail_Count -O--CK 100 100 --- - 0
172 Erase_Fail_Count -O--CK 100 100 --- - 0
173 Ave_Block-Erase_Count -O--CK 098 098 --- - 68
174 Unexpect_Power_Loss_Ct -O--CK 100 100 --- - 32
181 Program_Fail_Cnt_Total -O---K 100 100 --- - 1245551067265
183 SATA_Interfac_Downshift -O--CK 100 100 --- - 0
184 Error_Correction_Count -O--CK 100 100 --- - 0
187 Reported_Uncorrect -O--CK 100 100 --- - 0
188 Command_Timeout -O--CK 100 100 --- - 87
194 Temperature_Celsius -O---K 064 049 --- - 36 (Min/Max 19/51)
195 Cumulativ_Corrected_ECC -O-RCK 100 100 --- - 4294967295
196 Reallocated_Event_Count -O--CK 100 100 --- - 19
197 Current_Pending_Sector -O--CK 100 100 --- - 0
198 Offline_Uncorrectable ----CK 100 100 --- - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 --- - 0
202 Percent_Lifetime_Remain P---CK 098 098 --- - 2
206 Write_Error_Rate -OSR-- 100 100 --- - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 255 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 429 Current Device Internal Status Data log
0x25 GPL R/O 145 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 2000 Device vendor specific log
0xa0 SL VS 208 Device vendor specific log
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 80 Device vendor specific log
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 43274 -
# 2 Vendor (0xff) Completed without error 00% 43262 -
# 3 Vendor (0xff) Completed without error 00% 43247 -
# 4 Vendor (0xff) Completed without error 00% 43234 -
# 5 Vendor (0xff) Completed without error 00% 43219 -
# 6 Vendor (0xff) Completed without error 00% 43207 -
# 7 Vendor (0xff) Completed without error 00% 43193 -
# 8 Vendor (0xff) Completed without error 00% 43179 -
# 9 Vendor (0xff) Completed without error 00% 43164 -
#10 Vendor (0xff) Completed without error 00% 43150 -
#11 Vendor (0xff) Completed without error 00% 43137 -
#12 Vendor (0xff) Completed without error 00% 43124 -
#13 Vendor (0xff) Completed without error 00% 43109 -
#14 Vendor (0xff) Completed without error 00% 43096 -
#15 Vendor (0xff) Completed without error 00% 43081 -
#16 Vendor (0xff) Completed without error 00% 43068 -
#17 Vendor (0xff) Completed without error 00% 43054 -
#18 Vendor (0xff) Completed without error 00% 43041 -
#19 Vendor (0xff) Completed without error 00% 43028 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: -108/112 Celsius
Lifetime Min/Max Temperature: -108/112 Celsius
Under/Over Temperature Limit Count: 4/2
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (8)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 63 --- Lifetime Power-On Resets
0x01 0x010 4 43284 --- Power-on Hours
0x01 0x018 6 70230212229 --- Logical Sectors Written
0x01 0x020 6 205986433 --- Number of Write Commands
0x01 0x028 6 13129949673398 --- Logical Sectors Read
0x01 0x030 6 12342384081 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 87 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 36 --- Current Temperature
0x05 0x010 1 35 --- Average Short Term Temperature
0x05 0x018 1 42 --- Average Long Term Temperature
0x05 0x020 1 127 --- Highest Temperature
0x05 0x028 1 -123 --- Lowest Temperature
0x05 0x030 1 45 --- Highest Average Short Term Temperature
0x05 0x038 1 22 --- Lowest Average Short Term Temperature
0x05 0x040 1 43 --- Highest Average Long Term Temperature
0x05 0x048 1 23 --- Lowest Average Long Term Temperature
0x05 0x050 4 49 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 120 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 0 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 3 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,219 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p9 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 11/1300 SSDs
Device Model: Micron_M500_MTFDDAK960MAV
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: MU02
User Capacity: 960,197,124,096 bytes [960 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Dec 16 10:38:22 2020 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 3715) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 74) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -O--CK 100 100 --- - 585
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 --- - 0
9 Power_On_Hours -O--CK 100 100 --- - 43237
12 Power_Cycle_Count -O--CK 100 100 --- - 63
170 Reserved_Block_Count -O--CK 100 100 --- - 18
171 Program_Fail_Count -O--CK 100 100 --- - 0
172 Erase_Fail_Count -O--CK 100 100 --- - 0
173 Ave_Block-Erase_Count -O--CK 098 098 --- - 71
174 Unexpect_Power_Loss_Ct -O--CK 100 100 --- - 19
181 Program_Fail_Cnt_Total -O---K 100 100 --- - 1322862510196
183 SATA_Interfac_Downshift -O--CK 100 100 --- - 0
184 Error_Correction_Count -O--CK 100 100 --- - 0
187 Reported_Uncorrect -O--CK 100 100 --- - 0
188 Command_Timeout -O--CK 100 100 --- - 54
194 Temperature_Celsius -O---K 062 050 --- - 38 (Min/Max 20/50)
195 Cumulativ_Corrected_ECC -O-RCK 100 100 --- - 4294967295
196 Reallocated_Event_Count -O--CK 100 100 --- - 18
197 Current_Pending_Sector -O--CK 100 100 --- - 0
198 Offline_Uncorrectable ----CK 100 100 --- - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 --- - 0
202 Percent_Lifetime_Remain P---CK 098 098 --- - 2
206 Write_Error_Rate -OSR-- 100 100 --- - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 255 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 429 Current Device Internal Status Data log
0x25 GPL R/O 145 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 2000 Device vendor specific log
0xa0 SL VS 208 Device vendor specific log
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 80 Device vendor specific log
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 43231 -
# 2 Vendor (0xff) Completed without error 00% 43218 -
# 3 Vendor (0xff) Completed without error 00% 43202 -
# 4 Vendor (0xff) Completed without error 00% 43188 -
# 5 Vendor (0xff) Completed without error 00% 43173 -
# 6 Vendor (0xff) Completed without error 00% 43158 -
# 7 Vendor (0xff) Completed without error 00% 43144 -
# 8 Vendor (0xff) Completed without error 00% 43130 -
# 9 Vendor (0xff) Completed without error 00% 43116 -
#10 Vendor (0xff) Completed without error 00% 43103 -
#11 Vendor (0xff) Completed without error 00% 43087 -
#12 Vendor (0xff) Completed without error 00% 43071 -
#13 Vendor (0xff) Completed without error 00% 43054 -
#14 Vendor (0xff) Completed without error 00% 43040 -
#15 Vendor (0xff) Completed without error 00% 43025 -
#16 Vendor (0xff) Completed without error 00% 43009 -
#17 Vendor (0xff) Completed without error 00% 42993 -
#18 Vendor (0xff) Completed without error 00% 42976 -
#19 Vendor (0xff) Completed without error 00% 42963 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 38 Celsius
Power Cycle Min/Max Temperature: -106/60 Celsius
Lifetime Min/Max Temperature: -106/60 Celsius
Under/Over Temperature Limit Count: 3/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (394)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 63 --- Lifetime Power-On Resets
0x01 0x010 4 43237 --- Power-on Hours
0x01 0x018 6 75368147593 --- Logical Sectors Written
0x01 0x020 6 207799511 --- Number of Write Commands
0x01 0x028 6 9758928518700 --- Logical Sectors Read
0x01 0x030 6 9462269963 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 54 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 38 --- Current Temperature
0x05 0x010 1 37 --- Average Short Term Temperature
0x05 0x018 1 45 --- Average Long Term Temperature
0x05 0x020 1 123 --- Highest Temperature
0x05 0x028 1 -125 --- Lowest Temperature
0x05 0x030 1 48 --- Highest Average Short Term Temperature
0x05 0x038 1 21 --- Lowest Average Short Term Temperature
0x05 0x040 1 46 --- Highest Average Long Term Temperature
0x05 0x048 1 22 --- Lowest Average Long Term Temperature
0x05 0x050 4 41 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 120 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 0 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 4 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET