mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 3084, modified: 0)
This commit is contained in:
20
SSD/VisionTek/README.md
Normal file
20
SSD/VisionTek/README.md
Normal file
@@ -0,0 +1,20 @@
|
||||
VisionTek Solid State Drives
|
||||
============================
|
||||
|
||||
This is a list of all tested VisionTek solid state drive models and their MTBFs. See
|
||||
more info on reliability test in the [README](https://github.com/bsdhw/SMART).
|
||||
|
||||
SSD by Model
|
||||
------------
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Model | Size | Samples | Days | Err | MTBF |
|
||||
|-----------|--------------------|--------|---------|-------|-------|--------|
|
||||
| VisionTek | mSATA | 120 GB | 2 | 777 | 1016 | 0.00 |
|
199
SSD/VisionTek/mSATA/mSATA 120GB/B388BDFD524D
Normal file
199
SSD/VisionTek/mSATA/mSATA 120GB/B388BDFD524D
Normal file
@@ -0,0 +1,199 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: VisionTek mSATA 120GB
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 888914 ...
|
||||
Firmware Version: 604ABBF0
|
||||
User Capacity: 120,034,123,776 bytes [120 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Feb 3 20:17:41 2021 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7d) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Abort Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 48) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x0025) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate -O--CK 095 095 050 - 3026811
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 003 - 0
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 6467 (131 128 0)
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 287
|
||||
171 Unknown_Attribute -O-R-- 100 100 000 - 0
|
||||
172 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
174 Unknown_Attribute ----CK 000 000 000 - 205
|
||||
177 Wear_Leveling_Count ------ 000 000 000 - 1
|
||||
181 Program_Fail_Cnt_Total -O-R-- 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--C- 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel ------ 030 117 000 - 30 (Min/Max 16/117)
|
||||
194 Temperature_Celsius -O---K 030 117 000 - 30 (Min/Max 16/117)
|
||||
195 Hardware_ECC_Recovered --SRC- 120 120 000 - 3026811
|
||||
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
|
||||
201 Unknown_SSD_Attribute --SRC- 120 120 000 - 3026811
|
||||
204 Soft_ECC_Correction --SRC- 120 120 000 - 3026811
|
||||
230 Unknown_SSD_Attribute PO--C- 100 100 000 - 100
|
||||
231 Unknown_SSD_Attribute PO--C- 098 098 010 - 64424509441
|
||||
233 Media_Wearout_Indicator -O--CK 000 000 000 - 3259
|
||||
234 Unknown_Attribute -O--CK 000 000 000 - 2704
|
||||
241 Total_LBAs_Written -O--CK 000 000 000 - 2704
|
||||
242 Total_LBAs_Read -O--CK 000 000 000 - 184
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x04 GPL,SL R/O 6 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xb7 GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log not supported
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 16/117 Celsius
|
||||
Lifetime Min/Max Temperature: 16/117 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/63 Celsius
|
||||
Min/Max Temperature Limit: 0/67 Celsius
|
||||
Temperature History Size (Index): 478 (245)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 287 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 6467 --- Power-on Hours
|
||||
0x01 0x018 6 5672044753 --- Logical Sectors Written
|
||||
0x01 0x028 6 386596825 --- Logical Sectors Read
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x010 1 29 --- Average Short Term Temperature
|
||||
0x05 0x018 1 33 --- Average Long Term Temperature
|
||||
0x05 0x020 1 78 --- Highest Temperature
|
||||
0x05 0x028 1 26 --- Lowest Temperature
|
||||
0x05 0x030 1 47 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 27 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 33 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 27 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 160 --- Time in Over-Temperature
|
||||
0x05 0x058 1 63 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 1627 --- Number of ASR Events
|
||||
0x06 0x018 4 298 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 66 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 51 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
199
SSD/VisionTek/mSATA/mSATA 120GB/E7182756E4C2
Normal file
199
SSD/VisionTek/mSATA/mSATA 120GB/E7182756E4C2
Normal file
@@ -0,0 +1,199 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: VisionTek mSATA 120GB
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 888914 ...
|
||||
Firmware Version: 609ABBF0
|
||||
User Capacity: 120,034,123,776 bytes [120 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Jan 21 19:29:22 2021 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7d) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Abort Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 48) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x0025) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate -O--CK 095 095 050 - 23716202
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 003 - 0
|
||||
9 Power_On_Hours -O--CK 065 065 000 - 30876 (146 128 0)
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 177
|
||||
171 Unknown_Attribute -O-R-- 100 100 000 - 0
|
||||
172 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
174 Unknown_Attribute ----CK 000 000 000 - 21
|
||||
177 Wear_Leveling_Count ------ 000 000 000 - 1
|
||||
181 Program_Fail_Cnt_Total -O-R-- 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--C- 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel ------ 056 070 000 - 56 (Min/Max 22/70)
|
||||
194 Temperature_Celsius -O---K 056 070 000 - 56 (Min/Max 22/70)
|
||||
195 Hardware_ECC_Recovered --SRC- 120 120 000 - 23716202
|
||||
196 Reallocated_Event_Count PO--CK 100 100 003 - 0
|
||||
201 Unknown_SSD_Attribute --SRC- 120 120 000 - 23716202
|
||||
204 Soft_ECC_Correction --SRC- 120 120 000 - 23716202
|
||||
230 Unknown_SSD_Attribute PO--C- 100 100 000 - 100
|
||||
231 Unknown_SSD_Attribute PO--C- 098 098 010 - 4294967297
|
||||
233 Media_Wearout_Indicator -O--CK 000 000 000 - 8113
|
||||
234 Unknown_Attribute -O--CK 000 000 000 - 8382
|
||||
241 Total_LBAs_Written -O--CK 000 000 000 - 8382
|
||||
242 Total_LBAs_Read -O--CK 000 000 000 - 702
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x04 GPL,SL R/O 6 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xb7 GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log not supported
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 56 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/70 Celsius
|
||||
Lifetime Min/Max Temperature: 19/70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/63 Celsius
|
||||
Min/Max Temperature Limit: 0/67 Celsius
|
||||
Temperature History Size (Index): 478 (438)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 177 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 30876 --- Power-on Hours
|
||||
0x01 0x018 6 17578803524 --- Logical Sectors Written
|
||||
0x01 0x028 6 1473454986 --- Logical Sectors Read
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 41 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 56 --- Current Temperature
|
||||
0x05 0x010 1 54 --- Average Short Term Temperature
|
||||
0x05 0x018 1 55 --- Average Long Term Temperature
|
||||
0x05 0x020 1 70 --- Highest Temperature
|
||||
0x05 0x028 1 25 --- Lowest Temperature
|
||||
0x05 0x030 1 59 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 46 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 56 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 47 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 140 --- Time in Over-Temperature
|
||||
0x05 0x058 1 63 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 5854 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 2 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 149 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 150 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
Reference in New Issue
Block a user