mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 192)
This commit is contained in:
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Mar 25 17:16:49 2023 CET
|
||||
Local Time is: Sat Apr 1 04:55:45 2023 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 140 138 021 - 3983
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3085
|
||||
3 Spin_Up_Time POS--K 140 138 021 - 3958
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3182
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 044 044 000 - 41220
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 044 044 000 - 41307
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1730
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 328
|
||||
193 Load_Cycle_Count -O--CK 194 194 000 - 18038
|
||||
194 Temperature_Celsius -O---K 109 094 000 - 34
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1778
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 333
|
||||
193 Load_Cycle_Count -O--CK 194 194 000 - 18333
|
||||
194 Temperature_Celsius -O---K 110 094 000 - 33
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -131,8 +131,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/35 Celsius
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/34 Celsius
|
||||
Lifetime Min/Max Temperature: 0/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (369)
|
||||
Temperature History Size (Index): 478 (404)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -158,7 +158,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 18 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 8708 Vendor specific
|
||||
0x8000 4 2539 Vendor specific
|
||||
|
||||
|
Reference in New Issue