1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 0, modified: 192)

This commit is contained in:
Andrey Ponomarenko
2023-05-01 23:02:35 +03:00
parent 23ed3f49e3
commit f3c4ef82ea
192 changed files with 3487 additions and 3430 deletions

View File

@@ -10,7 +10,7 @@ User Capacity: 80,000,000,000 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Fri Apr 8 17:19:17 2022 EDT
Local Time is: Fri Apr 8 17:34:36 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
@@ -63,16 +63,16 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
3 Spin_Up_Time PO---- 177 160 021 - 2116
4 Start_Stop_Count -O--CK 099 099 000 - 1776
3 Spin_Up_Time PO---- 175 160 021 - 2233
4 Start_Stop_Count -O--CK 099 099 000 - 1777
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-- 200 200 051 - 0
9 Power_On_Hours -O--CK 088 088 000 - 8869
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1771
190 Airflow_Temperature_Cel -O---K 071 040 045 Past 29
194 Temperature_Celsius -O---K 114 083 000 - 29
12 Power_Cycle_Count -O--CK 099 099 000 - 1772
190 Airflow_Temperature_Cel -O---K 069 040 045 Past 31
194 Temperature_Celsius -O---K 112 083 000 - 31
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable ----C- 200 200 000 - 0
@@ -127,7 +127,7 @@ SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: ? Celsius
Power Cycle Min/Max Temperature: --/29 Celsius
Power Cycle Min/Max Temperature: --/31 Celsius
Lifetime Min/Max Temperature: --/64 Celsius
SCT Temperature History Version: 2
@@ -135,7 +135,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 5/65 Celsius
Min/Max Temperature Limit: 1/70 Celsius
Temperature History Size (Index): 128 (58)
Temperature History Size (Index): 128 (73)
SCT Error Recovery Control:
Read: Disabled
@@ -149,5 +149,5 @@ SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x8000 4 64 Vendor specific
0x8000 4 77 Vendor specific