smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -10,7 +10,7 @@ User Capacity: 80,000,000,000 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5528
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Mon Mar 18 17:20:23 2024 CDT
Local Time is: Fri Jul 26 11:19:35 2024 CDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 128
@@ -63,14 +63,14 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
3 Spin_Up_Time PO---- 204 165 021 - 791
4 Start_Stop_Count -O--CK 100 100 000 - 303
3 Spin_Up_Time PO---- 204 165 021 - 775
4 Start_Stop_Count -O--CK 100 100 000 - 305
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-- 200 200 051 - 0
9 Power_On_Hours -O--CK 001 001 000 - 89420
9 Power_On_Hours -O--CK 001 001 000 - 92528
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 299
12 Power_Cycle_Count -O--CK 100 100 000 - 301
190 Airflow_Temperature_Cel -O---K 067 040 045 Past 33
194 Temperature_Celsius -O---K 110 083 000 - 33
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
@@ -127,8 +127,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: --/35 Celsius
Current Temperature: 32 Celsius
Power Cycle Min/Max Temperature: --/40 Celsius
Lifetime Min/Max Temperature: --/65 Celsius
SCT Temperature History Version: 2
@@ -136,7 +136,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 5/65 Celsius
Min/Max Temperature Limit: 1/70 Celsius
Temperature History Size (Index): 128 (20)
Temperature History Size (Index): 128 (15)
SCT Error Recovery Control:
Read: Disabled
@@ -149,6 +149,6 @@ Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x8000 4 1371 Vendor specific
0x000a 2 38 Device-to-host register FISes sent due to a COMRESET
0x8000 4 6396349 Vendor specific

View File

@@ -10,7 +10,7 @@ User Capacity: 80,000,000,000 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Sat Apr 9 10:52:02 2022 EDT
Local Time is: Sat Apr 9 16:37:27 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
@@ -18,7 +18,7 @@ APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
@@ -63,16 +63,16 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
3 Spin_Up_Time PO---- 179 160 021 - 2016
4 Start_Stop_Count -O--CK 099 099 000 - 1783
3 Spin_Up_Time PO---- 179 160 021 - 2025
4 Start_Stop_Count -O--CK 099 099 000 - 1784
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-- 200 200 051 - 0
9 Power_On_Hours -O--CK 088 088 000 - 8871
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1778
190 Airflow_Temperature_Cel -O---K 078 040 045 Past 22
194 Temperature_Celsius -O---K 121 083 000 - 22
12 Power_Cycle_Count -O--CK 099 099 000 - 1779
190 Airflow_Temperature_Cel -O---K 080 040 045 Past 20
194 Temperature_Celsius -O---K 123 083 000 - 20
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable ----C- 200 200 000 - 0
@@ -127,7 +127,7 @@ SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: ? Celsius
Power Cycle Min/Max Temperature: --/22 Celsius
Power Cycle Min/Max Temperature: --/20 Celsius
Lifetime Min/Max Temperature: --/64 Celsius
SCT Temperature History Version: 2
@@ -135,7 +135,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 5/65 Celsius
Min/Max Temperature Limit: 1/70 Celsius
Temperature History Size (Index): 128 (40)
Temperature History Size (Index): 128 (48)
SCT Error Recovery Control:
Read: Disabled