@@ -15,7 +15,7 @@ Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 000000 ...
|
||||
Local Time is: Tue Jul 16 12:49:07 2024 CEST
|
||||
Local Time is: Wed Jul 24 21:52:23 2024 CEST
|
||||
Firmware Updates (0x1a): 5 Slots, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
|
||||
@@ -41,24 +41,24 @@ SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 29 Celsius
|
||||
Temperature: 30 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 1%
|
||||
Percentage Used: 1%
|
||||
Data Units Read: 1,438,811 [736 GB]
|
||||
Data Units Written: 8,085,814 [4.13 TB]
|
||||
Host Read Commands: 136,939,194
|
||||
Host Write Commands: 50,507,034
|
||||
Controller Busy Time: 335
|
||||
Power Cycles: 343
|
||||
Power On Hours: 2,173
|
||||
Data Units Read: 1,448,184 [741 GB]
|
||||
Data Units Written: 8,108,266 [4.15 TB]
|
||||
Host Read Commands: 137,242,266
|
||||
Host Write Commands: 51,099,112
|
||||
Controller Busy Time: 336
|
||||
Power Cycles: 347
|
||||
Power On Hours: 2,321
|
||||
Unsafe Shutdowns: 197
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 29 Celsius
|
||||
Temperature Sensor 2: 26 Celsius
|
||||
Temperature Sensor 1: 30 Celsius
|
||||
Temperature Sensor 2: 27 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
@@ -15,7 +15,7 @@ Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 000000 ...
|
||||
Local Time is: Wed May 29 10:56:44 2024 CEST
|
||||
Local Time is: Wed May 29 16:17:17 2024 CEST
|
||||
Firmware Updates (0x1a): 5 Slots, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
|
||||
@@ -45,20 +45,20 @@ Temperature: 45 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 1%
|
||||
Percentage Used: 4%
|
||||
Data Units Read: 42,502 [21.7 GB]
|
||||
Data Units Written: 3,190,635 [1.63 TB]
|
||||
Host Read Commands: 1,304,608
|
||||
Host Write Commands: 32,456,658
|
||||
Data Units Read: 44,079 [22.5 GB]
|
||||
Data Units Written: 3,204,112 [1.64 TB]
|
||||
Host Read Commands: 1,326,857
|
||||
Host Write Commands: 32,565,072
|
||||
Controller Busy Time: 50
|
||||
Power Cycles: 6
|
||||
Power On Hours: 2,439
|
||||
Power On Hours: 2,444
|
||||
Unsafe Shutdowns: 6
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 45 Celsius
|
||||
Temperature Sensor 2: 56 Celsius
|
||||
Temperature Sensor 2: 55 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -16,7 +16,7 @@ Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: a84397 ...
|
||||
Local Time is: Sun Feb 11 11:29:37 2024 CST
|
||||
Local Time is: Thu Feb 22 16:52:43 2024 CST
|
||||
Firmware Updates (0x0a): 5 Slots
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x0054): DS_Mngmt Sav/Sel_Feat Timestmp
|
||||
@@ -42,25 +42,25 @@ SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 47 Celsius
|
||||
Temperature: 30 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 16,275 [8.33 GB]
|
||||
Data Units Written: 196,509 [100 GB]
|
||||
Host Read Commands: 435,334
|
||||
Host Write Commands: 3,010,620
|
||||
Controller Busy Time: 59
|
||||
Power Cycles: 18
|
||||
Power On Hours: 136
|
||||
Unsafe Shutdowns: 3
|
||||
Data Units Read: 27,156 [13.9 GB]
|
||||
Data Units Written: 1,048,303 [536 GB]
|
||||
Host Read Commands: 660,380
|
||||
Host Write Commands: 13,451,694
|
||||
Controller Busy Time: 654
|
||||
Power Cycles: 19
|
||||
Power On Hours: 405
|
||||
Unsafe Shutdowns: 4
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 73 Celsius
|
||||
Temperature Sensor 1: 72 Celsius
|
||||
Temperature Sensor 2: 0 Celsius
|
||||
Temperature Sensor 3: 47 Celsius
|
||||
Temperature Sensor 3: 30 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
@@ -12,7 +12,7 @@ NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Local Time is: Wed Jul 3 03:51:30 2024 CEST
|
||||
Local Time is: Wed Nov 13 19:20:19 2024 CET
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x0015): Comp DS_Mngmt Sav/Sel_Feat
|
||||
@@ -34,17 +34,17 @@ SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 48 Celsius
|
||||
Temperature: 54 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 18,644 [9.54 GB]
|
||||
Data Units Written: 4,845,897 [2.48 TB]
|
||||
Host Read Commands: 490,311
|
||||
Host Write Commands: 42,097,887
|
||||
Controller Busy Time: 4,274
|
||||
Power Cycles: 16
|
||||
Power On Hours: 959
|
||||
Percentage Used: 1%
|
||||
Data Units Read: 25,781 [13.1 GB]
|
||||
Data Units Written: 28,190,259 [14.4 TB]
|
||||
Host Read Commands: 755,444
|
||||
Host Write Commands: 193,042,997
|
||||
Controller Busy Time: 18,737
|
||||
Power Cycles: 18
|
||||
Power On Hours: 4,177
|
||||
Unsafe Shutdowns: 11
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 240,057,409,536 [240 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 000000 ...
|
||||
Local Time is: Wed Jan 24 23:32:44 2024 EST
|
||||
Local Time is: Thu Apr 11 20:12:07 2024 EDT
|
||||
Firmware Updates (0x1a): 5 Slots, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
|
||||
@@ -41,24 +41,24 @@ SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 42 Celsius
|
||||
Temperature: 40 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 1%
|
||||
Percentage Used: 6%
|
||||
Data Units Read: 562,351 [287 GB]
|
||||
Data Units Written: 16,832,294 [8.61 TB]
|
||||
Host Read Commands: 17,086,237
|
||||
Host Write Commands: 249,067,073
|
||||
Controller Busy Time: 2,136
|
||||
Power Cycles: 14
|
||||
Power On Hours: 1,294
|
||||
Unsafe Shutdowns: 8
|
||||
Percentage Used: 15%
|
||||
Data Units Read: 621,946 [318 GB]
|
||||
Data Units Written: 36,942,118 [18.9 TB]
|
||||
Host Read Commands: 18,398,201
|
||||
Host Write Commands: 421,454,628
|
||||
Controller Busy Time: 3,946
|
||||
Power Cycles: 23
|
||||
Power On Hours: 3,160
|
||||
Unsafe Shutdowns: 12
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 42 Celsius
|
||||
Temperature Sensor 2: 41 Celsius
|
||||
Temperature Sensor 1: 40 Celsius
|
||||
Temperature Sensor 2: 38 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
Reference in New Issue