@@ -13,7 +13,7 @@ TRIM Command: Available
|
||||
Device is: Not in smartctl database 7.3/5528
|
||||
ATA Version is: ACS-3 T13/2161-D revision 4
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Sep 28 03:59:48 2023 PDT
|
||||
Local Time is: Fri Oct 6 04:39:58 2023 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -28,8 +28,8 @@ Wt Cache Reorder: Unavailable
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x02) Offline data collection activity
|
||||
was completed without error.
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
@@ -61,15 +61,15 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate -O--CK 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct -O--CK 100 100 050 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 050 - 249
|
||||
12 Power_Cycle_Count -O--CK 100 100 050 - 30
|
||||
9 Power_On_Hours -O--CK 100 100 050 - 440
|
||||
12 Power_Cycle_Count -O--CK 100 100 050 - 32
|
||||
160 Unknown_Attribute -O--CK 100 100 050 - 0
|
||||
161 Unknown_Attribute PO--CK 100 100 050 - 100
|
||||
163 Unknown_Attribute -O--CK 100 100 050 - 24
|
||||
164 Unknown_Attribute -O--CK 100 100 050 - 2753
|
||||
165 Unknown_Attribute -O--CK 100 100 050 - 18
|
||||
164 Unknown_Attribute -O--CK 100 100 050 - 4169
|
||||
165 Unknown_Attribute -O--CK 100 100 050 - 25
|
||||
166 Unknown_Attribute -O--CK 100 100 050 - 2
|
||||
167 Unknown_Attribute -O--CK 100 100 050 - 7
|
||||
167 Unknown_Attribute -O--CK 100 100 050 - 11
|
||||
168 Unknown_Attribute -O--CK 100 100 050 - 5050
|
||||
169 Unknown_Attribute -O--CK 100 100 050 - 100
|
||||
175 Program_Fail_Count_Chip -O--CK 100 100 050 - 0
|
||||
@@ -78,7 +78,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
178 Used_Rsvd_Blk_Cnt_Chip -O--CK 100 100 050 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 050 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 050 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 050 - 19
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 050 - 21
|
||||
194 Temperature_Celsius -O---K 100 100 050 - 40
|
||||
195 Hardware_ECC_Recovered -O--CK 100 100 050 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 050 - 0
|
||||
@@ -86,9 +86,9 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
198 Offline_Uncorrectable -O--CK 100 100 050 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 050 - 1
|
||||
232 Available_Reservd_Space -O--CK 100 100 050 - 100
|
||||
241 Total_LBAs_Written ----CK 100 100 050 - 37753
|
||||
242 Total_LBAs_Read ----CK 100 100 050 - 1593
|
||||
245 Unknown_Attribute -O--CK 100 100 050 - 15390
|
||||
241 Total_LBAs_Written ----CK 100 100 050 - 68108
|
||||
242 Total_LBAs_Read ----CK 100 100 050 - 2626
|
||||
245 Unknown_Attribute -O--CK 100 100 050 - 27904
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -154,12 +154,12 @@ SCT Error Recovery Control command not supported
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 30 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 249 --- Power-on Hours
|
||||
0x01 0x018 6 2474218753 --- Logical Sectors Written
|
||||
0x01 0x020 6 19072377 --- Number of Write Commands
|
||||
0x01 0x028 6 104447217 --- Logical Sectors Read
|
||||
0x01 0x030 6 1714052 --- Number of Read Commands
|
||||
0x01 0x008 4 32 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 440 --- Power-on Hours
|
||||
0x01 0x018 6 168590486 --- Logical Sectors Written
|
||||
0x01 0x020 6 30297246 --- Number of Write Commands
|
||||
0x01 0x028 6 172149626 --- Logical Sectors Read
|
||||
0x01 0x030 6 2527227 --- Number of Read Commands
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
@@ -173,5 +173,5 @@ ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0002 4 0 R_ERR response for data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x000a 4 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 5 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
Reference in New Issue