1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 57, modified: 148)

This commit is contained in:
Andrey Ponomarenko
2025-01-05 17:52:34 +03:00
parent ac3946f4a8
commit fc240b7043
205 changed files with 6735 additions and 2911 deletions

View File

@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Dec 17 13:20:16 2022 GMT
Local Time is: Wed Jan 4 00:50:34 2023 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,22 +65,22 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 077 062 - 0
2 Throughput_Performance P-S--K 100 100 040 - 0
3 Spin_Up_Time PO---K 125 100 033 - 2
4 Start_Stop_Count -O--CK 099 099 000 - 1577
3 Spin_Up_Time PO---K 126 100 033 - 2
4 Start_Stop_Count -O--CK 099 099 000 - 1595
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate POSR-K 100 100 067 - 0
8 Seek_Time_Performance P-S--K 100 100 040 - 0
9 Power_On_Hours -O--CK 040 040 000 - 26420
9 Power_On_Hours -O--CK 039 039 000 - 26797
10 Spin_Retry_Count PO--CK 100 100 060 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 1572
12 Power_Cycle_Count -O--CK 099 099 000 - 1590
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 103079542784
187 Reported_Uncorrect -O--CK 100 100 000 - 115964444672
188 Command_Timeout -O--CK 100 100 000 - 12886802434
190 Airflow_Temperature_Cel -O---K 066 047 045 - 34 (Min/Max 21/42)
191 G-Sense_Error_Rate -O--CK 097 097 000 - 873
190 Airflow_Temperature_Cel -O---K 058 047 045 - 42 (Min/Max 19/43)
191 G-Sense_Error_Rate -O--CK 097 097 000 - 883
192 Power-Off_Retract_Count -O--CK 100 100 000 - 5242960
193 Load_Cycle_Count -O--CK 081 081 000 - 190697
193 Load_Cycle_Count -O--CK 081 081 000 - 191282
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
@@ -131,8 +131,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: 21/42 Celsius
Current Temperature: 42 Celsius
Power Cycle Min/Max Temperature: 19/43 Celsius
Lifetime Min/Max Temperature: 6/53 Celsius
Specified Max Operating Temperature: 36 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/65 Celsius
Temperature History Size (Index): 128 (21)
Temperature History Size (Index): 128 (65)
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
@@ -161,7 +161,7 @@ ID Size Value Description
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS

View File

@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database 7.3/5528
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Jan 24 00:44:58 2024 GMT
Local Time is: Mon Mar 18 10:24:04 2024 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -66,21 +66,21 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 062 - 0
2 Throughput_Performance P-S--K 100 100 040 - 0
3 Spin_Up_Time PO---K 119 100 033 - 2
4 Start_Stop_Count -O--CK 100 100 000 - 1265
4 Start_Stop_Count -O--CK 100 100 000 - 1384
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate POSR-K 100 100 067 - 0
8 Seek_Time_Performance P-S--K 100 100 040 - 0
9 Power_On_Hours -O--CK 060 060 000 - 17749
9 Power_On_Hours -O--CK 057 057 000 - 18855
10 Spin_Retry_Count PO--CK 100 100 060 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 1261
12 Power_Cycle_Count -O--CK 100 100 000 - 1380
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 071 049 045 - 29 (Min/Max 24/33)
190 Airflow_Temperature_Cel -O---K 065 049 045 - 35 (Min/Max 23/35)
191 G-Sense_Error_Rate -O--CK 097 097 000 - 954
192 Power-Off_Retract_Count -O--CK 100 100 000 - 2949165
193 Load_Cycle_Count -O--CK 093 093 000 - 76227
192 Power-Off_Retract_Count -O--CK 100 100 000 - 3407924
193 Load_Cycle_Count -O--CK 093 093 000 - 77150
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
@@ -131,8 +131,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 24/33 Celsius
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 23/35 Celsius
Lifetime Min/Max Temperature: 11/51 Celsius
Specified Max Operating Temperature: 30 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/65 Celsius
Temperature History Size (Index): 128 (58)
Temperature History Size (Index): 128 (53)
SCT Error Recovery Control:
Read: 85 (8.5 seconds)

View File

@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Fri Jul 30 10:50:45 2021 BST
Local Time is: Sat Aug 7 09:02:07 2021 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,23 +65,23 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 062 - 0
2 Throughput_Performance P-S--K 100 100 040 - 0
3 Spin_Up_Time PO---K 253 100 033 - 1
4 Start_Stop_Count -O--CK 098 098 000 - 3371
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 240 (0 29)
3 Spin_Up_Time PO---K 243 100 033 - 1
4 Start_Stop_Count -O--CK 098 098 000 - 3407
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 256 (0 31)
7 Seek_Error_Rate POSR-K 100 100 067 - 0
8 Seek_Time_Performance P-S--K 100 100 040 - 0
9 Power_On_Hours -O--CK 048 048 000 - 22920
9 Power_On_Hours -O--CK 048 048 000 - 23010
10 Spin_Retry_Count PO--CK 100 100 060 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 3362
12 Power_Cycle_Count -O--CK 098 098 000 - 3398
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 691495108609
187 Reported_Uncorrect -O--CK 100 100 000 - 691495239681
188 Command_Timeout -O--CK 100 100 000 - 8591966208
190 Airflow_Temperature_Cel -O---K 060 047 045 - 40 (Min/Max 39/41)
191 G-Sense_Error_Rate -O--CK 096 096 000 - 1075
192 Power-Off_Retract_Count -O--CK 099 099 000 - 14090455
193 Load_Cycle_Count -O--CK 023 023 000 - 773934
196 Reallocated_Event_Count -O--CK 100 100 000 - 29
190 Airflow_Temperature_Cel -O---K 061 047 045 - 39 (Min/Max 33/41)
191 G-Sense_Error_Rate -O--CK 096 096 000 - 1078
192 Power-Off_Retract_Count -O--CK 099 099 000 - 14614751
193 Load_Cycle_Count -O--CK 023 023 000 - 776017
196 Reallocated_Event_Count -O--CK 100 100 000 - 31
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 0
@@ -174,8 +174,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 40 Celsius
Power Cycle Min/Max Temperature: 39/41 Celsius
Current Temperature: 39 Celsius
Power Cycle Min/Max Temperature: 33/41 Celsius
Lifetime Min/Max Temperature: 10/53 Celsius
Specified Max Operating Temperature: 35 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -185,7 +185,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/65 Celsius
Temperature History Size (Index): 128 (38)
Temperature History Size (Index): 128 (58)
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
@@ -204,8 +204,10 @@ ID Size Value Description
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS

View File

@@ -1,4 +1,4 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-RELEASE-p5 amd64] (local build)
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p3 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database 7.3/5528
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Mar 14 15:30:57 2024 CET
Local Time is: Mon Aug 12 13:54:10 2024 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,23 +64,23 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 062 - 0
2 Throughput_Performance P-S--K 198 100 040 - 98
3 Spin_Up_Time PO---K 253 100 033 - 1
4 Start_Stop_Count -O--CK 099 099 000 - 1814
2 Throughput_Performance P-S--K 198 100 040 - 97
3 Spin_Up_Time PO---K 238 100 033 - 1
4 Start_Stop_Count -O--CK 099 099 000 - 1892
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate POSR-K 100 100 067 - 0
8 Seek_Time_Performance P-S--K 132 100 040 - 47
9 Power_On_Hours -O--CK 032 032 000 - 29935
9 Power_On_Hours -O--CK 025 025 000 - 32865
10 Spin_Retry_Count PO--CK 100 100 060 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1781
12 Power_Cycle_Count -O--CK 099 099 000 - 1859
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 55834771456
188 Command_Timeout -O--CK 100 100 000 - 94506582016
190 Airflow_Temperature_Cel -O---K 066 054 045 - 34 (Min/Max 16/39)
190 Airflow_Temperature_Cel -O---K 063 054 045 - 37 (Min/Max 26/45)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 64
192 Power-Off_Retract_Count -O--CK 099 099 000 - 17563916
193 Load_Cycle_Count -O--CK 001 001 000 - 1016336
192 Power-Off_Retract_Count -O--CK 099 099 000 - 18350360
193 Load_Cycle_Count -O--CK 001 001 000 - 1265631
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
@@ -148,8 +148,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: 16/39 Celsius
Current Temperature: 37 Celsius
Power Cycle Min/Max Temperature: 26/45 Celsius
Lifetime Min/Max Temperature: 15/46 Celsius
Specified Max Operating Temperature: 31 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -159,7 +159,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/65 Celsius
Temperature History Size (Index): 128 (96)
Temperature History Size (Index): 128 (41)
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
@@ -178,8 +178,8 @@ ID Size Value Description
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x0009 2 10 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS