1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 57, modified: 148)

This commit is contained in:
Andrey Ponomarenko
2025-01-05 17:52:34 +03:00
parent ac3946f4a8
commit fc240b7043
205 changed files with 6735 additions and 2911 deletions

View File

@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database 7.3/5528
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sun Sep 3 18:25:26 2023 BST
Local Time is: Tue Oct 3 05:19:40 2023 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
@@ -65,26 +65,26 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 1
2 Throughput_Performance -OS--K 252 252 000 - 0
3 Spin_Up_Time PO---K 086 075 025 - 4466
4 Start_Stop_Count -O--CK 098 098 000 - 2528
3 Spin_Up_Time PO---K 086 075 025 - 4459
4 Start_Stop_Count -O--CK 098 098 000 - 2575
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
8 Seek_Time_Performance --S--K 252 252 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 10987
9 Power_On_Hours -O--CK 100 100 000 - 11103
10 Spin_Retry_Count -O--CK 252 252 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 68
12 Power_Cycle_Count -O--CK 100 100 000 - 409
11 Calibration_Retry_Count -O--CK 100 100 000 - 71
12 Power_Cycle_Count -O--CK 100 100 000 - 411
191 G-Sense_Error_Rate -O---K 100 100 000 - 4
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
194 Temperature_Celsius -O---- 057 047 000 - 43 (Min/Max 13/53)
194 Temperature_Celsius -O---- 064 047 000 - 35 (Min/Max 13/53)
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
197 Current_Pending_Sector -O--CK 252 252 000 - 0
198 Offline_Uncorrectable ----CK 252 252 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 782
223 Load_Retry_Count -O--CK 100 100 000 - 68
225 Load_Cycle_Count -O--CK 080 080 000 - 205618
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 807
223 Load_Retry_Count -O--CK 100 100 000 - 71
225 Load_Cycle_Count -O--CK 080 080 000 - 207760
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -131,8 +131,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 43 Celsius
Power Cycle Min/Max Temperature: 39/43 Celsius
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 24/44 Celsius
Lifetime Min/Max Temperature: 13/53 Celsius
Specified Max Operating Temperature: 80 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -142,7 +142,7 @@ Temperature Sampling Period: 5 minutes
Temperature Logging Interval: 5 minutes
Min/Max recommended Temperature: -5/80 Celsius
Min/Max Temperature Limit: -10/85 Celsius
Temperature History Size (Index): 128 (50)
Temperature History Size (Index): 128 (85)
SCT Error Recovery Control:
Read: Disabled