smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: M.2 (P80) 3TE6
|
||||
Serial Number: --
|
||||
Firmware Version: V20B09
|
||||
PCI Vendor/Subsystem ID: 0x1bc0
|
||||
IEEE OUI Identifier: 0x24693e
|
||||
Controller ID: 0
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 120,034,123,776 [120 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 24693e ...
|
||||
Local Time is: Sun Jan 15 02:23:34 2023 EST
|
||||
Firmware Updates (0x02): 1 Slot
|
||||
Optional Admin Commands (0x0006): Format Frmw_DL
|
||||
Optional NVM Commands (0x000f): Comp Wr_Unc DS_Mngmt Wr_Zero
|
||||
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 256 Pages
|
||||
Warning Comp. Temp. Threshold: 70 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 6.50W - - 0 0 0 0 5 5
|
||||
1 + 5.80W - - 1 1 1 1 30 30
|
||||
2 + 3.60W - - 2 2 2 2 100 100
|
||||
3 - 0.0500W - - 3 3 3 3 5000 10000
|
||||
4 - 0.0025W - - 4 4 4 4 5000 45000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 57 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 1%
|
||||
Percentage Used: 3%
|
||||
Data Units Read: 112,611 [57.6 GB]
|
||||
Data Units Written: 7,250,562 [3.71 TB]
|
||||
Host Read Commands: 3,644,645
|
||||
Host Write Commands: 191,646,937
|
||||
Controller Busy Time: 2,767
|
||||
Power Cycles: 46
|
||||
Power On Hours: 1,822
|
||||
Unsafe Shutdowns: 39
|
||||
Media and Data Integrity Errors: 64
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 82 Celsius
|
||||
Temperature Sensor 2: 57 Celsius
|
||||
Temperature Sensor 3: 57 Celsius
|
||||
Temperature Sensor 4: 57 Celsius
|
||||
Thermal Temp. 1 Transition Count: 1
|
||||
Thermal Temp. 1 Total Time: 24543
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|