1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 57, modified: 148)

This commit is contained in:
Andrey Ponomarenko
2025-01-05 17:52:34 +03:00
parent ac3946f4a8
commit fc240b7043
205 changed files with 6735 additions and 2911 deletions

View File

@@ -15,7 +15,7 @@ Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 000001 ...
Local Time is: Sat Jun 8 17:00:53 2024 CDT
Local Time is: Wed Aug 14 18:39:25 2024 CDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0007): Security Format Frmw_DL
Optional NVM Commands (0x0014): DS_Mngmt Sav/Sel_Feat
@@ -40,22 +40,22 @@ Critical Warning: 0x00
Temperature: 45 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 12%
Data Units Read: 1,335,151 [683 GB]
Data Units Written: 30,560,364 [15.6 TB]
Host Read Commands: 32,947,633
Host Write Commands: 582,278,722
Controller Busy Time: 10,324
Percentage Used: 14%
Data Units Read: 1,820,549 [932 GB]
Data Units Written: 34,210,783 [17.5 TB]
Host Read Commands: 45,563,990
Host Write Commands: 622,432,273
Controller Busy Time: 11,414
Power Cycles: 18
Power On Hours: 6,960
Power On Hours: 8,567
Unsafe Shutdowns: 16
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 1584
Critical Comp. Temperature Time: 46
Thermal Temp. 1 Transition Count: 1257
Thermal Temp. 1 Transition Count: 1261
Thermal Temp. 2 Transition Count: 59
Thermal Temp. 1 Total Time: 2476656
Thermal Temp. 1 Total Time: 2476761
Thermal Temp. 2 Total Time: 359468
Error Information (NVMe Log 0x01, 16 of 64 entries)

View File

@@ -13,7 +13,7 @@ Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 486834 ...
Local Time is: Mon Sep 18 15:44:32 2023 EDT
Local Time is: Fri Oct 27 13:32:22 2023 EDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0015): Comp DS_Mngmt Sav/Sel_Feat
@@ -38,15 +38,15 @@ Critical Warning: 0x00
Temperature: 55 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 7%
Data Units Read: 96,154 [49.2 GB]
Data Units Written: 20,653,142 [10.5 TB]
Host Read Commands: 2,110,248
Host Write Commands: 241,617,135
Controller Busy Time: 1,206
Power Cycles: 52
Power On Hours: 1,712
Unsafe Shutdowns: 27
Percentage Used: 16%
Data Units Read: 365,850 [187 GB]
Data Units Written: 46,571,751 [23.8 TB]
Host Read Commands: 8,324,413
Host Write Commands: 499,035,489
Controller Busy Time: 4,319
Power Cycles: 54
Power On Hours: 2,644
Unsafe Shutdowns: 29
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
@@ -58,5 +58,7 @@ No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
0 Short Completed without error 1664 - - - - -
0 Short Completed without error 2610 - - - - -
1 Short Completed without error 1830 - - - - -
2 Short Completed without error 1664 - - - - -