@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jun 15 21:03:16 2024 CEST
|
||||
Local Time is: Sun Aug 4 10:08:09 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 2048
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 729
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 6
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 3233
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 739
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 8
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 075 052 000 - 25
|
||||
190 Airflow_Temperature_Cel -O--CK 074 052 000 - 26
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 667
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 7301608035
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 8934980947
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -127,8 +127,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 25 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/40 Celsius
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/40 Celsius
|
||||
Lifetime Min/Max Temperature: 23/45 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -139,7 +139,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (83)
|
||||
Temperature History Size (Index): 128 (32)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -148,23 +148,23 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 729 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2048 --- Power-on Hours
|
||||
0x01 0x018 6 7301608035 --- Logical Sectors Written
|
||||
0x01 0x020 6 128113255 --- Number of Write Commands
|
||||
0x01 0x028 6 5724651119 --- Logical Sectors Read
|
||||
0x01 0x030 6 37156510 --- Number of Read Commands
|
||||
0x01 0x038 6 232000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 739 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3233 --- Power-on Hours
|
||||
0x01 0x018 6 8934980947 --- Logical Sectors Written
|
||||
0x01 0x020 6 190582157 --- Number of Write Commands
|
||||
0x01 0x028 6 6170147032 --- Logical Sectors Read
|
||||
0x01 0x030 6 39556303 --- Number of Read Commands
|
||||
0x01 0x038 6 152000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 25 --- Current Temperature
|
||||
0x05 0x008 1 26 --- Current Temperature
|
||||
0x05 0x020 1 45 --- Highest Temperature
|
||||
0x05 0x028 1 23 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 439 --- Number of Hardware Resets
|
||||
0x06 0x008 4 488 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -185,8 +185,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
@@ -194,3 +194,5 @@ ID Size Value Description
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
|
||||
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jun 15 21:03:16 2024 CEST
|
||||
Local Time is: Sun Aug 4 10:08:09 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 8271
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1321
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 10
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 9456
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1331
|
||||
177 Wear_Leveling_Count PO--C- 099 099 000 - 11
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 075 049 000 - 25
|
||||
190 Airflow_Temperature_Cel -O--CK 074 049 000 - 26
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 120
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 17663582535
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 19296955655
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 25 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/40 Celsius
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/40 Celsius
|
||||
Lifetime Min/Max Temperature: 20/51 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -140,7 +140,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (19)
|
||||
Temperature History Size (Index): 128 (96)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -149,23 +149,23 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1321 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 8271 --- Power-on Hours
|
||||
0x01 0x018 6 17663582535 --- Logical Sectors Written
|
||||
0x01 0x020 6 204040608 --- Number of Write Commands
|
||||
0x01 0x028 6 11619146189 --- Logical Sectors Read
|
||||
0x01 0x030 6 150032092 --- Number of Read Commands
|
||||
0x01 0x038 6 2862000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 1331 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 9456 --- Power-on Hours
|
||||
0x01 0x018 6 19296955655 --- Logical Sectors Written
|
||||
0x01 0x020 6 266651935 --- Number of Write Commands
|
||||
0x01 0x028 6 12050362613 --- Logical Sectors Read
|
||||
0x01 0x030 6 152359536 --- Number of Read Commands
|
||||
0x01 0x038 6 2795000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 682 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 25 --- Current Temperature
|
||||
0x05 0x008 1 26 --- Current Temperature
|
||||
0x05 0x020 1 51 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 5893 --- Number of Hardware Resets
|
||||
0x06 0x008 4 5942 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -186,8 +186,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|