smartctl 7.3 2022-02-28 r5338 [OpenBSD 7.2 amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint M5 Device Model: SAMSUNG HM160HI Serial Number: -- LU WWN Device Id: 5 0f0000 ... Firmware Version: HH100-15 User Capacity: 160,041,885,696 bytes [160 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database 7.3/5319 ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 0 SATA Version is: SATA 2.5, 1.5 Gb/s Local Time is: Sun Apr 9 14:00:44 2023 CDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART Status not supported: Incomplete response, ATA output registers missing SMART overall-health self-assessment test result: PASSED Warning: This result is based on an Attribute check. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 56) seconds. Offline data collection capabilities: (0x51) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 56) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 252 252 025 Pre-fail Always - 2000 4 Start_Stop_Count 0x0032 097 097 000 Old_age Always - 3610 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 1 7 Seek_Error_Rate 0x000f 252 252 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 252 252 015 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 1569 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 7 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 406 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 1840 184 End-to-End_Error 0x0033 252 252 070 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 252 252 000 Old_age Always - 0 188 Command_Timeout 0x0032 252 252 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 066 048 040 Old_age Always - 34 (Min/Max 6/60) 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 1993 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 102 193 Load_Cycle_Count 0x0032 096 096 000 Old_age Always - 42514 194 Temperature_Celsius 0x0022 064 048 000 Old_age Always - 34 (Min/Max 6/60) 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 0 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 252 252 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x0032 252 252 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.