smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.8] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint M7 Device Model: SAMSUNG HM500JI Serial Number: -- LU WWN Device Id: 5 0024e9 ... Firmware Version: 2AC101C4 User Capacity: 500,107,862,016 bytes [500 GB] Sector Size: 512 bytes logical/physical Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Tue Nov 3 18:00:29 2020 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART Status not supported: Incomplete response, ATA output registers missing SMART overall-health self-assessment test result: PASSED Warning: This result is based on an Attribute check. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 7920) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 132) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 6633 2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0 3 Spin_Up_Time 0x0023 091 090 025 Pre-fail Always - 3020 4 Start_Stop_Count 0x0032 095 095 000 Old_age Always - 5376 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 25413 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 392 12 Power_Cycle_Count 0x0032 095 095 000 Old_age Always - 5255 191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 973 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0 194 Temperature_Celsius 0x0002 064 050 000 Old_age Always - 28 (Min/Max 5/52) 195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 093 093 000 Old_age Always - 210 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0036 100 100 000 Old_age Always - 5 200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 14031 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 392 225 Load_Cycle_Count 0x0032 026 026 000 Old_age Always - 756389 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Completed [00% left] (0-65535) 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.