smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus Device Model: ST380013AS Serial Number: -- Firmware Version: 3.00 User Capacity: 80,026,361,856 bytes [80.0 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database 7.3/5319 ATA Version is: ATA/ATAPI-6 T13/1410D revision 2 Local Time is: Thu Dec 15 19:40:50 2022 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 47) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 058 048 006 - 22535908 3 Spin_Up_Time PO---- 098 098 000 - 0 4 Start_Stop_Count -O--CK 097 097 020 - 3503 5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0 7 Seek_Error_Rate POSR-- 088 060 030 - 707712020 9 Power_On_Hours -O--CK 077 077 000 - 20665 10 Spin_Retry_Count PO--C- 100 100 097 - 0 12 Power_Cycle_Count -O--CK 097 097 020 - 3480 194 Temperature_Celsius -O---K 026 048 000 - 26 (0 12 0 0 0) 195 Hardware_ECC_Recovered -O-RC- 058 048 000 - 22535908 197 Current_Pending_Sector -O--C- 100 100 000 - 0 198 Offline_Uncorrectable ----C- 100 100 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0 200 Multi_Zone_Error_Rate ------ 100 253 000 - 0 202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory not supported SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 SL R/O 5 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 SL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x20 SL R/O 1 Streaming performance log [OBS-8] 0x21 SL R/O 1 Write stream error log 0x22 SL R/O 1 Read stream error log 0x23 SL R/O 1 Delayed sector log [OBS-8] 0x80-0x9f SL R/W 16 Host vendor specific log 0xa0 SL VS 1 Device vendor specific log 0xa1 SL VS 20 Device vendor specific log 0xa2 SL VS 101 Device vendor specific log 0xa8 SL VS 20 Device vendor specific log 0xa9 SL VS 1 Device vendor specific log SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log Version: 1 No Errors Logged SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Commands not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) not supported