smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE i386] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Caviar SE Serial ATA Device Model: WDC WD2000JD-00FYB0 Serial Number: -- Firmware Version: 02.05D02 User Capacity: 200,049,647,616 bytes [200 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-6 (minor revision not indicated) Local Time is: Thu Mar 3 14:34:48 2022 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM level is: 254 (maximum performance), recommended: 128 APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 6942) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 88) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 200 200 051 - 0 3 Spin_Up_Time POS--- 139 122 021 - 3550 4 Start_Stop_Count -O--CK 100 100 040 - 509 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate PO-R-- 100 253 051 - 0 9 Power_On_Hours -O--CK 001 001 000 - 92010 10 Spin_Retry_Count PO--C- 100 100 051 - 1 11 Calibration_Retry_Count PO--C- 100 100 051 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 508 194 Temperature_Celsius -O---K 117 253 000 - 33 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--C- 200 200 000 - 0 198 Offline_Uncorrectable -O--C- 200 200 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 253 000 - 1 200 Multi_Zone_Error_Rate P--R-- 200 155 051 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning Read SMART Log Directory failed: Input/output error General Purpose Log Directory not supported SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log Version: 1 No Errors Logged SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Commands not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) not supported