smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p4 amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Red Device Model: WDC WD30EFRX-68AX9N0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 80.00A80 User Capacity: 3,000,592,982,016 bytes [3.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sun Nov 7 23:28:28 2021 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (42420) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 425) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x70bd) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 179 175 021 - 6008 4 Start_Stop_Count -O--CK 091 091 000 - 9743 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 014 014 000 - 62886 10 Spin_Retry_Count -O--CK 100 100 000 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 970 192 Power-Off_Retract_Count -O--CK 200 200 000 - 663 193 Load_Cycle_Count -O--CK 197 197 000 - 9079 194 Temperature_Celsius -O---K 107 103 000 - 43 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 001 000 - 1362 200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) Device Error Count: 6 CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 6 [5] occurred at disk power-on lifetime: 4571 hours (190 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 61 00 0c 00 00 00 00 00 00 00 00 Device Fault; Error: ABRT Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ef 00 03 00 0c 00 00 00 00 00 00 00 00 3d+11:37:55.625 SET FEATURES [Set transfer mode] e5 00 00 00 00 00 00 00 00 00 00 00 00 3d+11:37:55.625 CHECK POWER MODE ec 00 00 00 00 00 00 00 00 00 00 00 00 3d+11:37:55.624 IDENTIFY DEVICE ec 00 00 00 00 00 00 00 00 00 00 00 00 3d+11:37:50.757 IDENTIFY DEVICE ec 00 00 00 00 00 00 00 00 00 00 00 00 3d+11:37:50.757 IDENTIFY DEVICE Error 5 [4] occurred at disk power-on lifetime: 4571 hours (190 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 61 00 0c 00 00 00 00 00 00 00 00 Device Fault; Error: ABRT Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ef 00 03 00 0c 00 00 00 00 00 00 00 00 3d+11:35:05.051 SET FEATURES [Set transfer mode] e5 00 00 00 00 00 00 00 00 00 00 00 00 3d+11:35:05.051 CHECK POWER MODE ec 00 00 00 00 00 00 00 00 00 00 00 00 3d+11:35:05.049 IDENTIFY DEVICE 61 01 00 00 a8 00 00 38 cd 94 80 40 00 3d+11:35:02.392 WRITE FPDMA QUEUED 61 01 00 00 a0 00 00 38 cd 93 80 40 00 3d+11:35:02.391 WRITE FPDMA QUEUED Error 4 [3] occurred at disk power-on lifetime: 4571 hours (190 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 61 00 00 00 00 38 cd 65 88 40 00 Device Fault; Error: ABRT at LBA = 0x38cd6588 = 952984968 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 01 00 00 a8 00 00 38 cd 94 80 40 00 3d+11:35:02.392 WRITE FPDMA QUEUED 61 01 00 00 a0 00 00 38 cd 93 80 40 00 3d+11:35:02.391 WRITE FPDMA QUEUED 61 01 00 00 98 00 00 38 cd 92 80 40 00 3d+11:35:02.390 WRITE FPDMA QUEUED 61 01 00 00 90 00 00 38 cd 91 80 40 00 3d+11:35:02.389 WRITE FPDMA QUEUED 61 01 00 00 88 00 00 38 cd 90 80 40 00 3d+11:35:02.388 WRITE FPDMA QUEUED Error 3 [2] occurred at disk power-on lifetime: 4552 hours (189 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 1d 3c b1 40 40 00 Error: UNC at LBA = 0x1d3cb140 = 490516800 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 01 00 00 00 00 00 1d 3c b1 40 40 00 2d+16:52:27.096 READ FPDMA QUEUED 60 01 00 00 00 00 00 1d 3c b0 40 40 00 2d+16:52:24.430 READ FPDMA QUEUED 60 01 00 00 00 00 00 1d 3c af 40 40 00 2d+16:52:24.430 READ FPDMA QUEUED 60 01 00 00 00 00 00 1d 3c ae 40 40 00 2d+16:52:24.430 READ FPDMA QUEUED 60 01 00 00 00 00 00 1d 3c ad 40 40 00 2d+16:52:24.429 READ FPDMA QUEUED Error 2 [1] occurred at disk power-on lifetime: 355 hours (14 days + 19 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 61 00 0c 00 00 00 00 00 00 00 00 Device Fault; Error: ABRT Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ef 00 03 00 0c 00 00 00 00 00 00 00 00 00:06:35.511 SET FEATURES [Set transfer mode] e5 00 00 00 00 00 00 00 00 00 00 00 00 00:06:35.511 CHECK POWER MODE ec 00 00 00 00 00 00 00 00 00 00 00 00 00:06:35.510 IDENTIFY DEVICE 61 01 00 00 08 00 00 52 5c d2 80 40 00 00:06:34.799 WRITE FPDMA QUEUED 61 01 00 00 00 00 00 52 5c d1 80 40 00 00:06:34.798 WRITE FPDMA QUEUED Error 1 [0] occurred at disk power-on lifetime: 355 hours (14 days + 19 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 04 -- 61 00 00 00 00 52 5c a3 40 40 00 Device Fault; Error: ABRT at LBA = 0x525ca340 = 1381802816 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 01 00 00 08 00 00 52 5c d2 80 40 00 00:06:34.799 WRITE FPDMA QUEUED 61 01 00 00 00 00 00 52 5c d1 80 40 00 00:06:34.798 WRITE FPDMA QUEUED 61 01 00 00 f8 00 00 52 5c d0 80 40 00 00:06:34.789 WRITE FPDMA QUEUED 61 01 00 00 f0 00 00 52 5c cf 80 40 00 00:06:34.789 WRITE FPDMA QUEUED 61 01 00 00 e8 00 00 52 5c ce 80 40 00 00:06:34.789 WRITE FPDMA QUEUED SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 38413 - # 2 Short offline Completed without error 00% 21397 - # 3 Short offline Completed without error 00% 12863 - # 4 Short offline Completed without error 00% 6475 - # 5 Short offline Interrupted (host reset) 60% 4571 - # 6 Short offline Completed without error 00% 504 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 43 Celsius Power Cycle Min/Max Temperature: 25/47 Celsius Lifetime Min/Max Temperature: 2/47 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (331) SCT Error Recovery Control: Read: 70 (7.0 seconds) Write: 70 (7.0 seconds) Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 17 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 18 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 2164240 Vendor specific