smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Intel X25-E SSDs Device Model: SSDSA2SH032G1SB INTEL Serial Number: -- LU WWN Device Id: 5 001517 ... Firmware Version: 845C8862 User Capacity: 32,000,000,000 bytes [32.0 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device TRIM Command: Unavailable Device is: In smartctl database 7.3/5319 ATA Version is: ATA/ATAPI-7 T13/1532D revision 1 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Fri May 20 13:45:30 2022 CDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 1) seconds. Offline data collection capabilities: (0x75) SMART execute Offline immediate. No Auto Offline data collection support. Abort Offline collection upon new command. No Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 2) minutes. Conveyance self-test routine recommended polling time: ( 1) minutes. SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 3 Spin_Up_Time ------ 100 000 000 - 0 4 Start_Stop_Count ------ 100 000 000 - 0 5 Reallocated_Sector_Ct -O---- 100 100 000 - 0 9 Power_On_Hours -O---- 100 100 000 - 61124 12 Power_Cycle_Count -O---- 100 100 000 - 245 192 Unsafe_Shutdown_Count -O---- 100 100 000 - 154 232 Available_Reservd_Space PO---- 100 100 010 - 0 233 Media_Wearout_Indicator -O---- 099 099 000 - 0 225 Host_Writes_32MiB ------ 200 200 000 - 250355 226 Intel_Internal -O---- 255 000 000 - 0 227 Intel_Internal -O---- 000 000 000 - 0 228 Intel_Internal -O---- 000 000 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 0 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 8 Comprehensive SMART error log 0x03 SL R/O 1 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 SL R/O 1 Extended self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x4d GPL - 1 Reserved 0x80-0x9f SL R/W 16 Host vendor specific log 0xff GPL - 65024 Reserved SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log Version: 1 No Errors Logged SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 61123 - # 2 Extended offline Completed without error 00% 43146 - # 3 Conveyance offline Completed without error 00% 43146 - # 4 Short offline Completed without error 00% 43146 - SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Commands not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) not supported