smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p8 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus
Device Model: ST3120026A
Serial Number: --
Firmware Version: 3.06
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-6 T13/1410D revision 2
Local Time is: Thu Sep 3 15:35:42 2020 MDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 85) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 059 053 006 - 49121878
3 Spin_Up_Time PO---- 096 096 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 18
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 3
7 Seek_Error_Rate POSR-- 077 060 030 - 56507429
9 Power_On_Hours -O--CK 071 071 000 - 25826
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 099 099 020 - 1131
194 Temperature_Celsius -O---K 031 055 000 - 31
195 Hardware_ECC_Recovered -O-RC- 059 052 000 - 49121878
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 191 000 - 16
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory not supported
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 SL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 SL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x20 SL R/O 1 Streaming performance log [OBS-8]
0x21 SL R/O 1 Write stream error log
0x22 SL R/O 1 Read stream error log
0x23 SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f SL R/W 16 Host vendor specific log
0xa0 SL VS 1 Device vendor specific log
0xa1 SL VS 20 Device vendor specific log
0xa2 SL VS 101 Device vendor specific log
0xa8 SL VS 20 Device vendor specific log
0xa9 SL VS 1 Device vendor specific log
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
ATA Error Count: 96 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 96 occurred at disk power-on lifetime: 6036 hours (251 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 f9 0a e0 e4 Error: UNC at LBA = 0x04e00af9 = 81791737
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 f8 0a e0 e4 00 00:04:23.996 READ DMA
27 00 00 00 00 00 e0 00 00:04:23.996 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 02 00:04:23.988 IDENTIFY DEVICE
ef 03 45 00 00 00 a0 02 00:04:31.928 SET FEATURES [Set transfer mode]
27 00 00 00 00 00 e0 00 00:04:31.927 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 95 occurred at disk power-on lifetime: 6036 hours (251 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 f9 0a e0 e4 Error: UNC at LBA = 0x04e00af9 = 81791737
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 f8 0a e0 e4 00 00:04:23.996 READ DMA
27 00 00 00 00 00 e0 00 00:04:23.996 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 02 00:04:23.988 IDENTIFY DEVICE
ef 03 45 00 00 00 a0 02 00:04:23.980 SET FEATURES [Set transfer mode]
27 00 00 00 00 00 e0 00 00:04:23.980 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 94 occurred at disk power-on lifetime: 6036 hours (251 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 f9 0a e0 e4 Error: UNC at LBA = 0x04e00af9 = 81791737
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 f8 0a e0 e4 00 00:04:23.996 READ DMA
27 00 00 00 00 00 e0 00 00:04:23.996 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 02 00:04:23.988 IDENTIFY DEVICE
ef 03 45 00 00 00 a0 02 00:04:23.980 SET FEATURES [Set transfer mode]
27 00 00 00 00 00 e0 00 00:04:23.980 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 93 occurred at disk power-on lifetime: 6036 hours (251 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 f9 0a e0 e4 Error: UNC at LBA = 0x04e00af9 = 81791737
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 f8 0a e0 e4 00 00:04:16.057 READ DMA
27 00 00 00 00 00 e0 00 00:04:16.056 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 02 00:04:16.050 IDENTIFY DEVICE
ef 03 45 00 00 00 a0 02 00:04:12.100 SET FEATURES [Set transfer mode]
27 00 00 00 00 00 e0 00 00:04:12.099 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 92 occurred at disk power-on lifetime: 6036 hours (251 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 f9 0a e0 e4 Error: UNC at LBA = 0x04e00af9 = 81791737
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 f8 0a e0 e4 00 00:04:16.057 READ DMA
27 00 00 00 00 00 e0 00 00:04:16.056 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 02 00:04:16.050 IDENTIFY DEVICE
ef 03 45 00 00 00 a0 02 00:04:12.100 SET FEATURES [Set transfer mode]
27 00 00 00 00 00 e0 00 00:04:12.099 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported

View File

@@ -0,0 +1,85 @@
smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.8] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.9
Device Model: ST3120211AS
Serial Number: --
Firmware Version: 3.AAE
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Tue Oct 20 19:35:01 2020 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 51) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 115 084 006 Pre-fail Always - 0
3 Spin_Up_Time 0x0003 096 095 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 250
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 1
7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 635769891
9 Power_On_Hours 0x0032 087 087 000 Old_age Always - 12208
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 289
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 078 049 045 Old_age Always - 22 (Min/Max 21/24)
194 Temperature_Celsius 0x0022 022 051 000 Old_age Always - 22 (0 10 0 0 0)
195 Hardware_ECC_Recovered 0x001a 057 046 000 Old_age Always - 15700593
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0
202 Data_Address_Mark_Errs 0x0032 100 253 000 Old_age Always - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.