1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 1098, modified: 0)

This commit is contained in:
Andrey Ponomarenko
2020-11-03 14:43:05 +03:00
parent f8d5dc7417
commit 51569f7bd1
1098 changed files with 194109 additions and 0 deletions

View File

@@ -0,0 +1,238 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE i386] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar
Device Model: WDC WD800BB-00HEA0
Serial Number: --
Firmware Version: 13.03G13
User Capacity: 80,026,361,856 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-6 (minor revision not indicated)
Local Time is: Sun Oct 4 21:30:13 2020 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 128
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 2460) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 35) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 200 200 051 - 10794
3 Spin_Up_Time POS--- 100 100 021 - 2375
4 Start_Stop_Count -O--CK 097 097 040 - 3528
5 Reallocated_Sector_Ct PO--CK 197 197 140 - 20
7 Seek_Error_Rate PO-R-- 200 200 051 - 0
9 Power_On_Hours -O--CK 001 001 000 - 103742
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count PO--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 2493
194 Temperature_Celsius -O---K 112 010 000 - 31
196 Reallocated_Event_Count -O--CK 199 199 000 - 1
197 Current_Pending_Sector -O--C- 200 151 000 - 0
198 Offline_Uncorrectable -O--C- 200 149 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 001 000 - 11711
200 Multi_Zone_Error_Rate P--R-- 200 001 051 Past 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
Read SMART Log Directory failed: Input/output error
General Purpose Log Directory not supported
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
Warning: ATA error count 15969 inconsistent with error log pointer 5
ATA Error Count: 15969 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 15969 occurred at disk power-on lifetime: 2732 hours (113 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 01 7b f6 ad f1 Error: UNC 1 sectors at LBA = 0x01adf67b = 28178043
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 02 7a f6 ad 01 51 5d+14:51:29.500 READ DMA
c8 00 02 7a f6 ad 01 51 5d+14:51:27.560 READ DMA
c8 00 02 7a f6 ad 01 51 5d+14:51:25.650 READ DMA
c8 00 02 7a f6 ad 01 51 5d+14:51:23.720 READ DMA
c8 00 02 7a f6 ad 01 51 5d+14:51:21.805 READ DMA
Error 15968 occurred at disk power-on lifetime: 2732 hours (113 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 01 7b f6 ad f1 Error: UNC 1 sectors at LBA = 0x01adf67b = 28178043
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 02 7a f6 ad 01 51 5d+14:51:27.560 READ DMA
c8 00 02 7a f6 ad 01 51 5d+14:51:25.650 READ DMA
c8 00 02 7a f6 ad 01 51 5d+14:51:23.720 READ DMA
c8 00 02 7a f6 ad 01 51 5d+14:51:21.805 READ DMA
c8 00 02 78 f6 ad 01 51 5d+14:51:21.800 READ DMA
Error 15967 occurred at disk power-on lifetime: 2732 hours (113 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 01 7b f6 ad f1 Error: UNC 1 sectors at LBA = 0x01adf67b = 28178043
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 02 7a f6 ad 01 51 5d+14:51:25.650 READ DMA
c8 00 02 7a f6 ad 01 51 5d+14:51:23.720 READ DMA
c8 00 02 7a f6 ad 01 51 5d+14:51:21.805 READ DMA
c8 00 02 78 f6 ad 01 51 5d+14:51:21.800 READ DMA
c8 00 02 76 f6 ad 01 51 5d+14:51:21.800 READ DMA
Error 15966 occurred at disk power-on lifetime: 2732 hours (113 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 01 7b f6 ad f1 Error: UNC 1 sectors at LBA = 0x01adf67b = 28178043
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 02 7a f6 ad 01 51 5d+14:51:23.720 READ DMA
c8 00 02 7a f6 ad 01 51 5d+14:51:21.805 READ DMA
c8 00 02 78 f6 ad 01 51 5d+14:51:21.800 READ DMA
c8 00 02 76 f6 ad 01 51 5d+14:51:21.800 READ DMA
c8 00 02 74 f6 ad 01 51 5d+14:51:21.800 READ DMA
Error 15965 occurred at disk power-on lifetime: 2732 hours (113 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 01 7b f6 ad f1 Error: UNC 1 sectors at LBA = 0x01adf67b = 28178043
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 02 7a f6 ad 01 51 5d+14:51:21.805 READ DMA
c8 00 02 78 f6 ad 01 51 5d+14:51:21.800 READ DMA
c8 00 02 76 f6 ad 01 51 5d+14:51:21.800 READ DMA
c8 00 02 74 f6 ad 01 51 5d+14:51:21.800 READ DMA
c8 00 02 72 f6 ad 01 51 5d+14:51:21.800 READ DMA
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 38045 -
# 2 Short offline Completed without error 00% 37877 -
# 3 Short offline Completed without error 00% 37780 -
# 4 Short offline Completed without error 00% 37612 -
# 5 Short offline Completed without error 00% 37444 -
# 6 Short offline Completed without error 00% 37277 -
# 7 Short offline Completed without error 00% 37109 -
# 8 Short offline Completed without error 00% 36941 -
# 9 Short offline Completed without error 00% 36773 -
#10 Short offline Completed without error 00% 36606 -
#11 Short offline Completed without error 00% 36438 -
#12 Short offline Completed without error 00% 36270 -
#13 Short offline Completed without error 00% 36102 -
#14 Short offline Completed without error 00% 35935 -
#15 Short offline Completed without error 00% 35767 -
#16 Short offline Completed without error 00% 35599 -
#17 Short offline Completed without error 00% 35432 -
#18 Short offline Completed without error 00% 35264 -
#19 Short offline Completed without error 00% 35096 -
#20 Short offline Completed without error 00% 34928 -
#21 Short offline Completed without error 00% 34761 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported

View File

@@ -0,0 +1,170 @@
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p8 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar SE Serial ATA
Device Model: WDC WD800JD-08MSA1
Serial Number: --
Firmware Version: 10.01E01
User Capacity: 80,032,038,912 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Wed Aug 19 06:36:01 2020 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 2580) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 34) minutes.
Conveyance self-test routine
recommended polling time: ( 6) minutes.
SCT capabilities: (0x103f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
3 Spin_Up_Time PO---- 167 166 021 - 2650
4 Start_Stop_Count -O--CK 100 100 000 - 123
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-- 200 200 051 - 0
9 Power_On_Hours -O--CK 001 001 000 - 112511
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 110
190 Airflow_Temperature_Cel -O---K 075 053 000 - 25
194 Temperature_Celsius -O---K 118 096 000 - 25
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable ----C- 200 200 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate P--R-- 200 200 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 46970 -
# 2 Short offline Completed without error 00% 46946 -
# 3 Short offline Completed without error 00% 46922 -
# 4 Short offline Completed without error 00% 46898 -
# 5 Extended offline Completed without error 00% 46876 -
# 6 Short offline Completed without error 00% 46874 -
# 7 Short offline Completed without error 00% 46851 -
# 8 Short offline Completed without error 00% 46827 -
# 9 Short offline Completed without error 00% 46803 -
#10 Short offline Completed without error 00% 46779 -
#11 Short offline Completed without error 00% 46755 -
#12 Short offline Completed without error 00% 46731 -
#13 Extended offline Completed without error 00% 46708 -
#14 Short offline Completed without error 00% 46707 -
#15 Short offline Completed without error 00% 46683 -
#16 Short offline Completed without error 00% 46659 -
#17 Short offline Completed without error 00% 46635 -
#18 Short offline Completed without error 00% 46611 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 25 Celsius
Power Cycle Min/Max Temperature: --/38 Celsius
Lifetime Min/Max Temperature: --/48 Celsius
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 5/65 Celsius
Min/Max Temperature Limit: 1/70 Celsius
Temperature History Size (Index): 128 (40)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 43 Device-to-host register FISes sent due to a COMRESET
0x8000 4 25372658 Vendor specific