mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 1098, modified: 0)
This commit is contained in:
219
SSD/Micron/1100/1100 SATA 256GB/D6FA6B783462
Normal file
219
SSD/Micron/1100/1100 SATA 256GB/D6FA6B783462
Normal file
@@ -0,0 +1,219 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Micron 1100 SATA 256GB
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M0DL003
|
||||
User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: M.2
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Aug 20 14:27:22 2020 +08
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 678) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 4) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 010 - 2
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 536
|
||||
12 Power_Cycle_Count PO--CK 100 100 001 - 969
|
||||
181 Program_Fail_Cnt_Total PO--CK 100 100 001 - 0
|
||||
182 Erase_Fail_Count_Total PO--CK 100 100 001 - 0
|
||||
177 Wear_Leveling_Count PO--CK 096 096 010 - 60
|
||||
187 Reported_Uncorrect PO--CK 100 100 001 - 0
|
||||
194 Temperature_Celsius -O---K 048 034 000 - 52 (Min/Max 13/66)
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
238 Unknown_Attribute ----CK 096 096 000 - 4
|
||||
175 Program_Fail_Count_Chip PO--CK 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip PO--CK 100 100 000 - 0
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--CK 100 100 000 - 1
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2043
|
||||
195 Cumulativ_Corrected_ECC POSR-K 100 000 050 Past 0
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 14731613003
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 10873621325
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--CK 100 100 000 - 2
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa1 GPL,SL VS 3 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 13824 Device vendor specific log
|
||||
0xa4 GPL VS 354 Device vendor specific log
|
||||
0xa4 SL VS 98 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 64 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 64 Device vendor specific log
|
||||
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 354 -
|
||||
# 2 Short offline Completed without error 00% 332 -
|
||||
# 3 Short offline Completed without error 00% 299 -
|
||||
# 4 Short offline Completed without error 00% 233 -
|
||||
# 5 Short offline Completed without error 00% 232 -
|
||||
# 6 Short offline Completed without error 00% 213 -
|
||||
# 7 Short offline Completed without error 00% 211 -
|
||||
# 8 Short offline Completed without error 00% 183 -
|
||||
# 9 Short offline Completed without error 00% 179 -
|
||||
#10 Short offline Completed without error 00% 179 -
|
||||
#11 Extended offline Completed without error 00% 171 -
|
||||
#12 Conveyance offline Aborted by host 00% 171 -
|
||||
#13 Extended offline Aborted by host 00% 171 -
|
||||
#14 Short offline Completed without error 00% 106 -
|
||||
#15 Short offline Completed without error 00% 100 -
|
||||
#16 Short offline Completed without error 00% 99 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 52 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/58 Celsius
|
||||
Lifetime Min/Max Temperature: 13/66 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (236)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 969 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 536 --- Power-on Hours
|
||||
0x01 0x018 6 14731613003 --- Logical Sectors Written
|
||||
0x01 0x020 6 214099122 --- Number of Write Commands
|
||||
0x01 0x028 6 10873621325 --- Logical Sectors Read
|
||||
0x01 0x030 6 145493079 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 972 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 52 --- Current Temperature
|
||||
0x05 0x010 1 48 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 66 --- Highest Temperature
|
||||
0x05 0x028 1 13 --- Lowest Temperature
|
||||
0x05 0x030 1 50 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 46 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 11091 --- Number of Hardware Resets
|
||||
0x06 0x010 4 277 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 4 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 8 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
220
SSD/Micron/1100/1100 SATA 512GB/6467DB653292
Normal file
220
SSD/Micron/1100/1100 SATA 512GB/6467DB653292
Normal file
@@ -0,0 +1,220 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Micron 1100 SATA 512GB
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M0DL022
|
||||
User Capacity: 512,110,190,592 bytes [512 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: M.2
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Aug 5 10:55:28 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 1357) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 7) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 879
|
||||
12 Power_Cycle_Count PO--CK 100 100 001 - 1214
|
||||
181 Program_Fail_Cnt_Total PO--CK 100 100 001 - 0
|
||||
182 Erase_Fail_Count_Total PO--CK 100 100 001 - 0
|
||||
177 Wear_Leveling_Count PO--CK 099 099 010 - 19
|
||||
187 Reported_Uncorrect PO--CK 100 100 001 - 0
|
||||
194 Temperature_Celsius -O---K 070 026 000 - 30 (Min/Max 10/74)
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
238 Unknown_Attribute ----CK 099 099 000 - 1
|
||||
175 Program_Fail_Count_Chip PO--CK 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip PO--CK 100 100 000 - 0
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--CK 100 100 000 - 0
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2458
|
||||
195 Cumulativ_Corrected_ECC POSR-K 100 000 050 Past 0
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 8758374980
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 6328956429
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa1 GPL,SL VS 3 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 13824 Device vendor specific log
|
||||
0xa4 GPL VS 354 Device vendor specific log
|
||||
0xa4 SL VS 98 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 64 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 64 Device vendor specific log
|
||||
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 649 -
|
||||
# 2 Short offline Completed without error 00% 648 -
|
||||
# 3 Short offline Completed without error 00% 617 -
|
||||
# 4 Short offline Completed without error 00% 597 -
|
||||
# 5 Short offline Completed without error 00% 553 -
|
||||
# 6 Short offline Completed without error 00% 552 -
|
||||
# 7 Short offline Completed without error 00% 551 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 508 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 451 -
|
||||
#10 Short offline Completed without error 00% 70 -
|
||||
#11 Short offline Completed without error 00% 5 -
|
||||
#12 Short offline Completed without error 00% 5 -
|
||||
#13 Short offline Completed without error 00% 5 -
|
||||
#14 Short offline Self-test routine in progress 90% 5 -
|
||||
#15 Extended offline Completed without error 00% 3 -
|
||||
#16 Short offline Completed without error 00% 3 -
|
||||
#17 Short offline Completed without error 00% 2 -
|
||||
#18 Short offline Completed without error 00% 2 -
|
||||
#19 Short offline Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/31 Celsius
|
||||
Lifetime Min/Max Temperature: 10/74 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (443)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1214 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 879 --- Power-on Hours
|
||||
0x01 0x018 6 8758374980 --- Logical Sectors Written
|
||||
0x01 0x020 6 127985915 --- Number of Write Commands
|
||||
0x01 0x028 6 6328956429 --- Logical Sectors Read
|
||||
0x01 0x030 6 71469861 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 1479 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x010 1 39 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 74 --- Highest Temperature
|
||||
0x05 0x028 1 10 --- Lowest Temperature
|
||||
0x05 0x030 1 44 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 36 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 4704 --- Number of Hardware Resets
|
||||
0x06 0x010 4 382 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 1 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 2 Device-to-host register FISes sent due to a COMRESET
|
||||
|
224
SSD/Micron/1100/1100_MTFDDAK256TBN/609D16207464
Normal file
224
SSD/Micron/1100/1100_MTFDDAK256TBN/609D16207464
Normal file
@@ -0,0 +1,224 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Micron_1100_MTFDDAK256TBN
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M0MU031
|
||||
User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Aug 20 12:38:42 2020 JST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x04) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 485) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 16503
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 10
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 066 066 000 - 510
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 5
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 068 055 000 - 32 (Min/Max 19/45)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 066 066 001 - 34
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 136065055136
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 4255560446
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 1711415471
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2062
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa1 GPL,SL VS 3 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 13824 Device vendor specific log
|
||||
0xa4 GPL VS 354 Device vendor specific log
|
||||
0xa4 SL VS 98 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 64 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 64 Device vendor specific log
|
||||
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 16500 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 16379 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 16164 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 15956 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 15752 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 15559 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 15368 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 15180 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 14951 -
|
||||
#10 Vendor (0xff) Completed without error 00% 14758 -
|
||||
#11 Vendor (0xff) Completed without error 00% 14533 -
|
||||
#12 Vendor (0xff) Completed without error 00% 14334 -
|
||||
#13 Vendor (0xff) Completed without error 00% 14128 -
|
||||
#14 Vendor (0xff) Completed without error 00% 13936 -
|
||||
#15 Vendor (0xff) Completed without error 00% 13749 -
|
||||
#16 Vendor (0xff) Completed without error 00% 13552 -
|
||||
#17 Vendor (0xff) Completed without error 00% 13357 -
|
||||
#18 Vendor (0xff) Completed without error 00% 13174 -
|
||||
#19 Vendor (0xff) Completed without error 00% 12970 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/43 Celsius
|
||||
Lifetime Min/Max Temperature: 19/45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (11)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 10 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 16503 --- Power-on Hours
|
||||
0x01 0x018 6 136065055136 --- Logical Sectors Written
|
||||
0x01 0x020 6 1687397789 --- Number of Write Commands
|
||||
0x01 0x028 6 6604262413 --- Logical Sectors Read
|
||||
0x01 0x030 6 2633520698 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 10 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x010 1 31 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 45 --- Highest Temperature
|
||||
0x05 0x028 1 19 --- Lowest Temperature
|
||||
0x05 0x030 1 31 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 30 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 253 --- Number of Hardware Resets
|
||||
0x06 0x010 4 81 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 34 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 218 Device-to-host register FISes sent due to a COMRESET
|
||||
|
226
SSD/Micron/1100/1100_MTFDDAK256TBN/DC991C0655B5
Normal file
226
SSD/Micron/1100/1100_MTFDDAK256TBN/DC991C0655B5
Normal file
@@ -0,0 +1,226 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Micron_1100_MTFDDAK256TBN
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M0MU031
|
||||
User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Aug 20 12:38:42 2020 JST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 801) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 16504
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 10
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 067 067 000 - 507
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 5
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 070 054 000 - 30 (Min/Max 19/46)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 067 067 001 - 33
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 135564941255
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 4239929570
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 1705109243
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2060
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa1 GPL,SL VS 3 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 13824 Device vendor specific log
|
||||
0xa4 GPL VS 354 Device vendor specific log
|
||||
0xa4 SL VS 98 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 64 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 64 Device vendor specific log
|
||||
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 16486 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 16242 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 16024 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 15823 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 15631 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 15455 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 15295 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 15088 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 14866 -
|
||||
#10 Vendor (0xff) Completed without error 00% 14668 -
|
||||
#11 Vendor (0xff) Completed without error 00% 14474 -
|
||||
#12 Vendor (0xff) Completed without error 00% 14272 -
|
||||
#13 Vendor (0xff) Completed without error 00% 14087 -
|
||||
#14 Vendor (0xff) Completed without error 00% 13881 -
|
||||
#15 Vendor (0xff) Completed without error 00% 13695 -
|
||||
#16 Vendor (0xff) Completed without error 00% 13502 -
|
||||
#17 Vendor (0xff) Completed without error 00% 13323 -
|
||||
#18 Vendor (0xff) Completed without error 00% 13141 -
|
||||
#19 Vendor (0xff) Completed without error 00% 12966 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Completed [00% left] (294021670-294087205)
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/44 Celsius
|
||||
Lifetime Min/Max Temperature: 19/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (464)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 10 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 16504 --- Power-on Hours
|
||||
0x01 0x018 6 135564941255 --- Logical Sectors Written
|
||||
0x01 0x020 6 1689432493 --- Number of Write Commands
|
||||
0x01 0x028 6 7121375215 --- Logical Sectors Read
|
||||
0x01 0x030 6 2637131206 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 10 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x010 1 31 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 46 --- Highest Temperature
|
||||
0x05 0x028 1 19 --- Lowest Temperature
|
||||
0x05 0x030 1 31 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 30 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 253 --- Number of Hardware Resets
|
||||
0x06 0x010 4 81 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 33 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 218 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
224
SSD/Micron/1100/1100_MTFDDAK512TBN/891C76D898A2
Normal file
224
SSD/Micron/1100/1100_MTFDDAK512TBN/891C76D898A2
Normal file
@@ -0,0 +1,224 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.4-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Micron_1100_MTFDDAK512TBN
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M0MU031
|
||||
User Capacity: 512,110,190,592 bytes [512 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Aug 20 06:36:15 2020 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x04) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 839) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 6) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 19161
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 7
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 068 068 000 - 488
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 4
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 067 053 000 - 33 (Min/Max 23/47)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 068 068 001 - 32
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 223519330757
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 7493147623
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 2459704294
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2475
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa1 GPL,SL VS 3 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 13824 Device vendor specific log
|
||||
0xa4 GPL VS 354 Device vendor specific log
|
||||
0xa4 SL VS 98 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 64 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 64 Device vendor specific log
|
||||
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 19154 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 19053 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 18808 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 18568 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 18337 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 18094 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 17843 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 17603 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 17368 -
|
||||
#10 Vendor (0xff) Completed without error 00% 17130 -
|
||||
#11 Vendor (0xff) Completed without error 00% 16879 -
|
||||
#12 Vendor (0xff) Completed without error 00% 16633 -
|
||||
#13 Vendor (0xff) Completed without error 00% 16412 -
|
||||
#14 Vendor (0xff) Completed without error 00% 16195 -
|
||||
#15 Vendor (0xff) Completed without error 00% 15982 -
|
||||
#16 Vendor (0xff) Completed without error 00% 15767 -
|
||||
#17 Vendor (0xff) Completed without error 00% 15530 -
|
||||
#18 Vendor (0xff) Completed without error 00% 15304 -
|
||||
#19 Vendor (0xff) Completed without error 00% 15092 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/47 Celsius
|
||||
Lifetime Min/Max Temperature: 23/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (283)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 7 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 19161 --- Power-on Hours
|
||||
0x01 0x018 6 223519330757 --- Logical Sectors Written
|
||||
0x01 0x020 6 3104819250 --- Number of Write Commands
|
||||
0x01 0x028 6 15884400666 --- Logical Sectors Read
|
||||
0x01 0x030 6 2808674537 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 7 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 28 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 47 --- Highest Temperature
|
||||
0x05 0x028 1 23 --- Lowest Temperature
|
||||
0x05 0x030 1 28 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 104 --- Number of Hardware Resets
|
||||
0x06 0x010 4 31 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 32 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 87 Device-to-host register FISes sent due to a COMRESET
|
||||
|
226
SSD/Micron/1100/1100_MTFDDAK512TBN/8F8C02B7B158
Normal file
226
SSD/Micron/1100/1100_MTFDDAK512TBN/8F8C02B7B158
Normal file
@@ -0,0 +1,226 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.4-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Micron_1100_MTFDDAK512TBN
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M0MU031
|
||||
User Capacity: 512,110,190,592 bytes [512 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Aug 20 06:36:15 2020 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 1272) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 7) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 19162
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 7
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 068 068 000 - 487
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 4
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 070 051 000 - 30 (Min/Max 23/49)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 068 068 001 - 32
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 223937118229
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 7502198999
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 2453047262
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2479
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa1 GPL,SL VS 3 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 13824 Device vendor specific log
|
||||
0xa4 GPL VS 354 Device vendor specific log
|
||||
0xa4 SL VS 98 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 64 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 64 Device vendor specific log
|
||||
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 19150 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 18913 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 18662 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 18411 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 18166 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 17923 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 17669 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 17416 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 17175 -
|
||||
#10 Vendor (0xff) Completed without error 00% 16927 -
|
||||
#11 Vendor (0xff) Completed without error 00% 16680 -
|
||||
#12 Vendor (0xff) Completed without error 00% 16454 -
|
||||
#13 Vendor (0xff) Completed without error 00% 16245 -
|
||||
#14 Vendor (0xff) Completed without error 00% 16030 -
|
||||
#15 Vendor (0xff) Completed without error 00% 15795 -
|
||||
#16 Vendor (0xff) Completed without error 00% 15573 -
|
||||
#17 Vendor (0xff) Completed without error 00% 15353 -
|
||||
#18 Vendor (0xff) Completed without error 00% 15139 -
|
||||
#19 Vendor (0xff) Completed without error 00% 14922 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Completed [00% left] (130625-196160)
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/49 Celsius
|
||||
Lifetime Min/Max Temperature: 23/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (255)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 7 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 19162 --- Power-on Hours
|
||||
0x01 0x018 6 223937118229 --- Logical Sectors Written
|
||||
0x01 0x020 6 3103185662 --- Number of Write Commands
|
||||
0x01 0x028 6 15869954023 --- Logical Sectors Read
|
||||
0x01 0x030 6 2826459999 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 7 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x010 1 29 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 49 --- Highest Temperature
|
||||
0x05 0x028 1 23 --- Lowest Temperature
|
||||
0x05 0x030 1 29 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 29 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 104 --- Number of Hardware Resets
|
||||
0x06 0x010 4 31 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 32 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 87 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
218
SSD/Micron/M600/M600_MTFDDAK256MBF/C69EAB9B1B3C
Normal file
218
SSD/Micron/M600/M600_MTFDDAK256MBF/C69EAB9B1B3C
Normal file
@@ -0,0 +1,218 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Device Model: Micron_M600_MTFDDAK256MBF
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: MU05
|
||||
User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 4
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Aug 27 08:23:06 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 978) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 6) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 39756
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 21
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 058 058 000 - 1267
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 8
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1947
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 068 045 000 - 32 (Min/Max 23/55)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 058 058 001 - 42
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 115882741020
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 3646047506
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 11122225002
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 16000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 16000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 2000 Device vendor specific log
|
||||
0xa0 SL VS 208 Device vendor specific log
|
||||
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 80 Device vendor specific log
|
||||
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 39750 -
|
||||
# 2 Short offline Completed without error 00% 39726 -
|
||||
# 3 Short offline Completed without error 00% 39702 -
|
||||
# 4 Short offline Completed without error 00% 39678 -
|
||||
# 5 Short offline Completed without error 00% 39654 -
|
||||
# 6 Extended offline Completed without error 00% 39631 -
|
||||
# 7 Short offline Completed without error 00% 39630 -
|
||||
# 8 Short offline Completed without error 00% 39606 -
|
||||
# 9 Short offline Completed without error 00% 39581 -
|
||||
#10 Short offline Completed without error 00% 39557 -
|
||||
#11 Short offline Completed without error 00% 39533 -
|
||||
#12 Short offline Completed without error 00% 39509 -
|
||||
#13 Short offline Completed without error 00% 39485 -
|
||||
#14 Extended offline Completed without error 00% 39462 -
|
||||
#15 Short offline Completed without error 00% 39461 -
|
||||
#16 Short offline Completed without error 00% 39437 -
|
||||
#17 Short offline Completed without error 00% 39413 -
|
||||
#18 Short offline Completed without error 00% 39388 -
|
||||
#19 Short offline Completed without error 00% 39364 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Completed [00% left] (57881389-57946924)
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/32 Celsius
|
||||
Lifetime Min/Max Temperature: 23/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (194)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 21 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 39756 --- Power-on Hours
|
||||
0x01 0x018 6 115882741020 --- Logical Sectors Written
|
||||
0x01 0x020 6 662996463 --- Number of Write Commands
|
||||
0x01 0x028 6 3732408215 --- Logical Sectors Read
|
||||
0x01 0x030 6 175499370 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 19 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x010 1 40 --- Average Short Term Temperature
|
||||
0x05 0x018 1 39 --- Average Long Term Temperature
|
||||
0x05 0x020 1 55 --- Highest Temperature
|
||||
0x05 0x028 1 23 --- Lowest Temperature
|
||||
0x05 0x030 1 46 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 37 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 43 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 39 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 313 --- Number of Hardware Resets
|
||||
0x06 0x010 4 117 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 42 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 75 Device-to-host register FISes sent due to a COMRESET
|
||||
|
198
SSD/Micron/MTFDDAK256/MTFDDAK256MAM-1K12/33DAAD77F144
Normal file
198
SSD/Micron/MTFDDAK256/MTFDDAK256MAM-1K12/33DAAD77F144
Normal file
@@ -0,0 +1,198 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron RealSSD m4/C400/P400
|
||||
Device Model: MTFDDAK256MAM-1K12
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: 08TH
|
||||
User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Sep 22 10:50:42 2020 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 0 (reserved)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 1190) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 19) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 26
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 4096
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 1250
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 5061
|
||||
170 Grown_Failing_Block_Ct PO--CK 100 100 010 - 1
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 91
|
||||
173 Wear_Leveling_Count PO--CK 096 096 010 - 133
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 80
|
||||
181 Non4k_Aligned_Access -O---K 100 100 000 - 8635 2617 6017
|
||||
183 SATA_Iface_Downshift -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 Factory_Bad_Block_Ct -OSR-- 100 100 000 - 107
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 0
|
||||
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 22870
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 1
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 1
|
||||
202 Perc_Rated_Life_Used ---RC- 096 096 000 - 4
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 255 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x83 SL R/W 1 Host vendor specific log
|
||||
0x84-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 2000 Device vendor specific log
|
||||
0xa0 SL VS 208 Device vendor specific log
|
||||
0xa1-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 0 Celsius
|
||||
Power Cycle Min/Max Temperature: --/ 0 Celsius
|
||||
Lifetime Min/Max Temperature: --/ 0 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (303)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
Write: 40 (4.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 5061 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1250 --- Power-on Hours
|
||||
0x01 0x018 6 24457578352 --- Logical Sectors Written
|
||||
0x01 0x020 6 532854465 --- Number of Write Commands
|
||||
0x01 0x028 6 40760249138 --- Logical Sectors Read
|
||||
0x01 0x030 6 943321724 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 0 --- Current Temperature
|
||||
0x05 0x010 1 0 --- Average Short Term Temperature
|
||||
0x05 0x018 1 0 --- Average Long Term Temperature
|
||||
0x05 0x020 1 0 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 0 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 0 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 0 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 0 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 - --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 86 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 1 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 5 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 4 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
Reference in New Issue
Block a user