1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 1098, modified: 0)

This commit is contained in:
Andrey Ponomarenko
2020-11-03 14:43:05 +03:00
parent f8d5dc7417
commit 51569f7bd1
1098 changed files with 194109 additions and 0 deletions

View File

@@ -0,0 +1,96 @@
smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.8] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: QUMO SSD
Serial Number: --
LU WWN Device Id: 5 000000 ...
Firmware Version: V0208
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-4 (minor revision not indicated)
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Oct 20 18:28:35 2020 +06
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (65535) seconds.
Offline data collection
capabilities: (0x79) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 30) minutes.
Conveyance self-test routine
recommended polling time: ( 6) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
5 Reallocated_Sector_Ct 0x0013 100 100 050 Pre-fail Always - 0
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 7
12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 5
160 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0
161 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 240
163 Unknown_Attribute 0x0003 100 100 050 Pre-fail Always - 86
164 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 7424
165 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 2
166 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0
167 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0
172 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 1
173 Unknown_Attribute 0x0022 100 100 000 Old_age Always - 0
192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always - 5
194 Temperature_Celsius 0x0023 070 070 000 Pre-fail Always - 30
196 Reallocated_Event_Count 0x0000 100 100 000 Old_age Offline - 0
198 Offline_Uncorrectable 0x0012 100 100 000 Old_age Always - 0
199 UDMA_CRC_Error_Count 0x000b 100 100 050 Pre-fail Always - 0
241 Total_LBAs_Written 0x0012 100 100 000 Old_age Always - 2042
242 Total_LBAs_Read 0x0012 100 100 000 Old_age Always - 211
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.