1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 14, modified: 3797)

This commit is contained in:
Andrey Ponomarenko
2023-02-14 02:15:20 +03:00
parent 274416644b
commit a41331e270
3811 changed files with 71570 additions and 67733 deletions

View File

@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 3b
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Fri Jun 18 01:01:13 2021 EDT
Local Time is: Sat Jun 19 02:40:23 2021 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 254
@@ -62,20 +62,20 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 253 100 051 - 0
3 Spin_Up_Time POS--- 100 100 015 - 5568
4 Start_Stop_Count -O--CK 100 100 000 - 395
4 Start_Stop_Count -O--CK 100 100 000 - 402
5 Reallocated_Sector_Ct PO--CK 253 253 010 - 0
7 Seek_Error_Rate -OSR-- 253 253 000 - 0
8 Seek_Time_Performance --S--K 253 253 000 - 0
9 Power_On_Hours -O--CK 100 100 000 - 51718
9 Power_On_Hours -O--CK 100 100 000 - 51739
10 Spin_Retry_Count -O--CK 253 253 000 - 0
11 Calibration_Retry_Count -O--C- 253 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 236
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 2012
12 Power_Cycle_Count -O--CK 100 100 000 - 241
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 6936
187 Reported_Uncorrect -O--CK 253 253 000 - 1703936
188 Command_Timeout -O--CK 253 253 000 - 0
190 Airflow_Temperature_Cel -O---K 074 063 000 - 26
194 Temperature_Celsius -O---K 160 127 000 - 26
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 2012
190 Airflow_Temperature_Cel -O---K 077 063 000 - 23
194 Temperature_Celsius -O---K 169 127 000 - 23
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 6936
196 Reallocated_Event_Count -O--CK 253 253 000 - 0
197 Total_Pending_Sectors -O--C- 100 100 000 - 1
198 Offline_Uncorrectable ----CK 253 100 000 - 0
@@ -148,8 +148,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 26 Celsius
Power Cycle Min/Max Temperature: 20/26 Celsius
Current Temperature: 23 Celsius
Power Cycle Min/Max Temperature: 19/28 Celsius
Lifetime Min/Max Temperature: 3/37 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -158,7 +158,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: -4/72 Celsius
Min/Max Temperature Limit: -9/77 Celsius
Temperature History Size (Index): 128 (28)
Temperature History Size (Index): 128 (110)
SCT Error Recovery Control:
Read: Disabled
@@ -179,7 +179,7 @@ ID Size Value Description
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC