smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-STABLE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-STABLE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital VelociRaptor (AF)
@@ -10,10 +10,10 @@ Firmware Version: 04.06A01
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 10000 rpm
Device is: In smartctl database [for details use: -P show]
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Jan 22 10:32:33 2021 CET
Local Time is: Wed Aug 17 22:01:15 2022 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,17 +65,17 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 193 190 021 - 3333
4 Start_Stop_Count -O--CK 100 100 000 - 123
3 Spin_Up_Time POS--K 193 190 021 - 3316
4 Start_Stop_Count -O--CK 100 100 000 - 143
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 023 023 000 - 56266
9 Power_On_Hours -O--CK 005 005 000 - 69918
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 122
192 Power-Off_Retract_Count -O--CK 200 200 000 - 42
193 Load_Cycle_Count -O--CK 200 200 000 - 88
194 Temperature_Celsius -O---K 120 104 000 - 30
12 Power_Cycle_Count -O--CK 100 100 000 - 142
192 Power-Off_Retract_Count -O--CK 200 200 000 - 56
193 Load_Cycle_Count -O--CK 200 200 000 - 98
194 Temperature_Celsius -O---K 108 097 000 - 42
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
@@ -115,24 +115,24 @@ No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 56141 -
# 2 Short offline Completed without error 00% 56114 -
# 3 Extended offline Completed without error 00% 55973 -
# 4 Extended offline Completed without error 00% 55806 -
# 5 Short offline Completed without error 00% 55778 -
# 6 Extended offline Completed without error 00% 55638 -
# 7 Short offline Completed without error 00% 55610 -
# 8 Extended offline Completed without error 00% 55470 -
# 9 Short offline Completed without error 00% 55442 -
#10 Extended offline Completed without error 00% 55302 -
#11 Short offline Completed without error 00% 55274 -
#12 Extended offline Completed without error 00% 55134 -
#13 Short offline Completed without error 00% 55107 -
#14 Extended offline Completed without error 00% 54967 -
#15 Short offline Completed without error 00% 54939 -
#16 Extended offline Completed without error 00% 54799 -
#17 Short offline Completed without error 00% 54771 -
#18 Extended offline Completed without error 00% 54631 -
# 1 Extended offline Completed without error 00% 4294 -
# 2 Short offline Completed without error 00% 4266 -
# 3 Extended offline Completed without error 00% 4126 -
# 4 Short offline Completed without error 00% 4098 -
# 5 Extended offline Completed without error 00% 3958 -
# 6 Short offline Completed without error 00% 3931 -
# 7 Extended offline Completed without error 00% 3791 -
# 8 Short offline Completed without error 00% 3763 -
# 9 Extended offline Completed without error 00% 3623 -
#10 Short offline Completed without error 00% 3595 -
#11 Extended offline Completed without error 00% 3455 -
#12 Short offline Completed without error 00% 3427 -
#13 Extended offline Completed without error 00% 3287 -
#14 Short offline Completed without error 00% 3259 -
#15 Extended offline Completed without error 00% 3119 -
#16 Short offline Completed without error 00% 3092 -
#17 Extended offline Completed without error 00% 2951 -
#18 Short offline Completed without error 00% 2924 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
@@ -148,9 +148,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 27/45 Celsius
Lifetime Min/Max Temperature: 19/46 Celsius
Current Temperature: 42 Celsius
Power Cycle Min/Max Temperature: 41/51 Celsius
Lifetime Min/Max Temperature: 19/53 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
@@ -161,7 +161,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (329)
Temperature History Size (Index): 478 (398)
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
@@ -174,19 +174,19 @@ Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 1 R_ERR response for data FIS
0x0003 2 1 R_ERR response for device-to-host data FIS
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 66 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 66 Device-to-host register FISes sent due to a COMRESET
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 16666537 Vendor specific
0x8000 4 1996818 Vendor specific

View File

@@ -1,5 +1,5 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-STABLE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-STABLE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital VelociRaptor (AF)
@@ -10,10 +10,10 @@ Firmware Version: 04.06A01
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 10000 rpm
Device is: In smartctl database [for details use: -P show]
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Jan 22 10:32:33 2021 CET
Local Time is: Wed Aug 17 22:01:15 2022 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -31,9 +31,8 @@ General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Self-test execution status: ( 121) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: ( 9180) seconds.
Offline data collection
@@ -64,23 +63,23 @@ SCT capabilities: (0x30bd) SCT Status supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 193 190 021 - 3350
4 Start_Stop_Count -O--CK 100 100 000 - 125
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 5
3 Spin_Up_Time POS--K 192 190 021 - 3375
4 Start_Stop_Count -O--CK 100 100 000 - 145
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 023 023 000 - 56269
9 Power_On_Hours -O--CK 005 005 000 - 69921
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 123
192 Power-Off_Retract_Count -O--CK 200 200 000 - 43
193 Load_Cycle_Count -O--CK 200 200 000 - 90
194 Temperature_Celsius -O---K 119 103 000 - 31
12 Power_Cycle_Count -O--CK 100 100 000 - 143
192 Power-Off_Retract_Count -O--CK 200 200 000 - 57
193 Load_Cycle_Count -O--CK 200 200 000 - 100
194 Temperature_Celsius -O---K 108 101 000 - 42
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 5
198 Offline_Uncorrectable ----CK 200 200 000 - 3
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 9
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -111,28 +110,59 @@ Address Access R/W Size Description
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
Device Error Count: 1
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1 [0] occurred at disk power-on lifetime: 4281 hours (178 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 14 8e df c0 40 00 Error: UNC at LBA = 0x148edfc0 = 344907712
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 58 00 00 14 8e e2 48 40 08 18d+18:47:01.127 READ FPDMA QUEUED
60 00 08 00 50 00 00 14 8e e0 28 40 08 18d+18:47:01.127 READ FPDMA QUEUED
60 00 08 00 48 00 00 14 8e df c0 40 08 18d+18:47:01.126 READ FPDMA QUEUED
60 00 08 00 40 00 00 14 8e dd 38 40 08 18d+18:47:01.124 READ FPDMA QUEUED
60 00 08 00 38 00 00 14 8e dc 20 40 08 18d+18:47:01.123 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 56144 -
# 2 Short offline Completed without error 00% 56116 -
# 3 Extended offline Completed without error 00% 55976 -
# 4 Extended offline Completed without error 00% 55809 -
# 5 Short offline Completed without error 00% 55781 -
# 6 Extended offline Completed without error 00% 55641 -
# 7 Short offline Completed without error 00% 55613 -
# 8 Extended offline Completed without error 00% 55473 -
# 9 Short offline Completed without error 00% 55445 -
#10 Extended offline Completed without error 00% 55305 -
#11 Short offline Completed without error 00% 55277 -
#12 Extended offline Completed without error 00% 55137 -
#13 Short offline Completed without error 00% 55109 -
#14 Extended offline Completed without error 00% 54969 -
#15 Short offline Completed without error 00% 54942 -
#16 Extended offline Completed without error 00% 54802 -
#17 Short offline Completed without error 00% 54774 -
#18 Extended offline Completed without error 00% 54634 -
# 1 Extended offline Completed: read failure 90% 4295 251747638
# 2 Short offline Completed without error 00% 4269 -
# 3 Extended offline Completed: read failure 90% 4127 251747720
# 4 Short offline Completed without error 00% 4101 -
# 5 Extended offline Completed: read failure 90% 3959 251747639
# 6 Short offline Completed: read failure 90% 3933 251747634
# 7 Extended offline Completed: read failure 90% 3792 251747632
# 8 Short offline Completed: read failure 90% 3766 251747632
# 9 Extended offline Completed: read failure 90% 3624 253734961
#10 Short offline Completed: read failure 90% 3598 304518216
#11 Extended offline Completed: read failure 90% 3456 304518216
#12 Short offline Completed: read failure 90% 3430 304518216
#13 Extended offline Completed: read failure 90% 3288 304518217
#14 Short offline Completed: read failure 90% 3262 304518216
#15 Extended offline Completed: read failure 90% 3120 304518216
#16 Short offline Completed: read failure 90% 3094 304518216
#17 Extended offline Completed: read failure 90% 2952 304518216
#18 Short offline Completed: read failure 90% 2927 304518216
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
@@ -148,9 +178,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 31 Celsius
Power Cycle Min/Max Temperature: 28/46 Celsius
Lifetime Min/Max Temperature: 19/47 Celsius
Current Temperature: 42 Celsius
Power Cycle Min/Max Temperature: 41/47 Celsius
Lifetime Min/Max Temperature: 19/49 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
@@ -161,7 +191,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (35)
Temperature History Size (Index): 478 (121)
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
@@ -181,12 +211,12 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 65 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 65 Device-to-host register FISes sent due to a COMRESET
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 16666721 Vendor specific
0x8000 4 1996842 Vendor specific