1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 14, modified: 3797)

This commit is contained in:
Andrey Ponomarenko
2023-02-14 02:15:20 +03:00
parent 274416644b
commit a41331e270
3811 changed files with 71570 additions and 67733 deletions

View File

@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Thu May 28 12:42:36 2020 EDT
Local Time is: Thu May 28 12:55:11 2020 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 128
@@ -74,8 +74,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 353
192 Power-Off_Retract_Count -O--CK 200 200 000 - 176
193 Load_Cycle_Count -O--CK 053 053 000 - 443872
194 Temperature_Celsius -O---K 110 091 000 - 42
193 Load_Cycle_Count -O--CK 053 053 000 - 443874
194 Temperature_Celsius -O---K 109 091 000 - 43
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 9
198 Offline_Uncorrectable ----CK 200 200 000 - 0
@@ -138,7 +138,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 42 Celsius
Current Temperature: 43 Celsius
Power Cycle Min/Max Temperature: 23/54 Celsius
Lifetime Min/Max Temperature: 42/61 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -148,7 +148,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (440)
Temperature History Size (Index): 478 (452)
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
@@ -169,7 +169,7 @@ ID Size Value Description
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 1524784 Vendor specific
0x8000 4 1525538 Vendor specific

View File

@@ -13,11 +13,11 @@ Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Fri Feb 12 18:20:57 2021 EST
Local Time is: Sat Feb 13 07:56:06 2021 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM level is: 254 (maximum performance)
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
@@ -65,17 +65,17 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 19
3 Spin_Up_Time POS--K 154 139 021 - 9266
4 Start_Stop_Count -O--CK 100 100 000 - 391
3 Spin_Up_Time POS--K 145 139 021 - 9733
4 Start_Stop_Count -O--CK 100 100 000 - 394
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 047 047 000 - 38926
9 Power_On_Hours -O--CK 047 047 000 - 38927
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 389
192 Power-Off_Retract_Count -O--CK 200 200 000 - 88
193 Load_Cycle_Count -O--CK 094 094 000 - 319860
194 Temperature_Celsius -O---K 126 100 000 - 26
12 Power_Cycle_Count -O--CK 100 100 000 - 392
192 Power-Off_Retract_Count -O--CK 200 200 000 - 90
193 Load_Cycle_Count -O--CK 094 094 000 - 319871
194 Temperature_Celsius -O---K 121 100 000 - 31
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 15
198 Offline_Uncorrectable ----CK 200 200 000 - 24
@@ -281,9 +281,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 26 Celsius
Power Cycle Min/Max Temperature: 18/26 Celsius
Lifetime Min/Max Temperature: 18/52 Celsius
Current Temperature: 31 Celsius
Power Cycle Min/Max Temperature: 31/32 Celsius
Lifetime Min/Max Temperature: 31/52 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
@@ -291,7 +291,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (237)
Temperature History Size (Index): 478 (329)
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
@@ -310,9 +310,9 @@ ID Size Value Description
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 1215 Vendor specific
0x8000 4 250 Vendor specific