mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 14, modified: 3797)
This commit is contained in:
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Apr 15 12:14:59 2022 CEST
|
||||
Local Time is: Fri May 13 22:02:20 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,17 +65,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 7
|
||||
3 Spin_Up_Time POS--K 141 139 021 - 3925
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 168
|
||||
3 Spin_Up_Time POS--K 141 139 021 - 3933
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 204
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 067 067 000 - 24615
|
||||
9 Power_On_Hours -O--CK 066 066 000 - 24853
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 166
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 132
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 35
|
||||
194 Temperature_Celsius -O---K 108 099 000 - 35
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 202
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 164
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 39
|
||||
194 Temperature_Celsius -O---K 107 099 000 - 36
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -132,8 +132,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/35 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/37 Celsius
|
||||
Lifetime Min/Max Temperature: 19/44 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (127)
|
||||
Temperature History Size (Index): 478 (170)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -167,7 +167,5 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 15622 Vendor specific
|
||||
|
||||
|
||||
0x8000 4 7730 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed May 4 21:01:08 2022 BST
|
||||
Local Time is: Thu May 5 22:16:00 2022 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -69,13 +69,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 114
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2441
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2466
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 110
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 100
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 13
|
||||
194 Temperature_Celsius -O---K 111 093 000 - 32
|
||||
194 Temperature_Celsius -O---K 110 093 000 - 33
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -132,7 +132,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/33 Celsius
|
||||
Lifetime Min/Max Temperature: 23/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (311)
|
||||
Temperature History Size (Index): 478 (390)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -167,5 +167,5 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 78016 Vendor specific
|
||||
0x8000 4 168816 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Feb 19 12:11:50 2022 CET
|
||||
Local Time is: Wed Feb 23 18:28:14 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -69,13 +69,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 60
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2775
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2878
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 60
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 58
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1
|
||||
194 Temperature_Celsius -O---K 104 088 000 - 39
|
||||
194 Temperature_Celsius -O---K 102 088 000 - 41
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -132,7 +132,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/42 Celsius
|
||||
Lifetime Min/Max Temperature: 27/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (232)
|
||||
Temperature History Size (Index): 478 (148)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -167,5 +167,5 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 595559 Vendor specific
|
||||
0x8000 4 963372 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Apr 7 20:49:07 2022 CEST
|
||||
Local Time is: Fri Apr 8 20:20:30 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,17 +65,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 141 141 021 - 3908
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 31
|
||||
3 Spin_Up_Time POS--K 142 141 021 - 3858
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 35
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 050 050 000 - 37195
|
||||
9 Power_On_Hours -O--CK 050 050 000 - 37196
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 29
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 17
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 13
|
||||
194 Temperature_Celsius -O---K 111 104 000 - 32
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 33
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 20
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 14
|
||||
194 Temperature_Celsius -O---K 113 104 000 - 30
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -132,9 +132,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/32 Celsius
|
||||
Lifetime Min/Max Temperature: 26/39 Celsius
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/29 Celsius
|
||||
Lifetime Min/Max Temperature: 27/39 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (107)
|
||||
Temperature History Size (Index): 478 (172)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -162,10 +162,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 9 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 2516 Vendor specific
|
||||
0x8000 4 249 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Mar 26 15:57:55 2022 CET
|
||||
Local Time is: Wed Jun 15 11:46:26 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 196 196 051 - 65540
|
||||
3 Spin_Up_Time POS--K 139 138 021 - 4025
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 57
|
||||
3 Spin_Up_Time POS--K 140 138 021 - 3966
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 59
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 062 061 000 - 28050
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 062 061 000 - 28052
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 55
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 47
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 9
|
||||
194 Temperature_Celsius -O---K 113 102 000 - 30
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 57
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 48
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 10
|
||||
194 Temperature_Celsius -O---K 115 102 000 - 28
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 185 185 000 - 619
|
||||
197 Current_Pending_Sector -O--CK 192 185 000 - 339
|
||||
198 Offline_Uncorrectable ----CK 185 185 000 - 619
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 197 197 000 - 627
|
||||
@@ -113,7 +113,7 @@ Address Access R/W Size Description
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
Device Error Count: 4385 (device log contains only the most recent 24 errors)
|
||||
Device Error Count: 4386 (device log contains only the most recent 24 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
@@ -129,6 +129,23 @@ Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 4386 [1] occurred at disk power-on lifetime: 28051 hours (1168 days + 19 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 00 01 00 00 12 36 fa 68 40 00 Error: IDNF at LBA = 0x1236fa68 = 305592936
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 08 00 00 90 00 00 12 37 02 68 40 08 00:21:20.014 WRITE FPDMA QUEUED
|
||||
61 00 30 00 88 00 00 0f e9 8b 68 40 08 00:21:18.901 WRITE FPDMA QUEUED
|
||||
61 00 08 00 80 00 00 0e 88 fe 68 40 08 00:21:18.901 WRITE FPDMA QUEUED
|
||||
61 00 08 00 78 00 00 02 41 2b 90 40 08 00:21:18.901 WRITE FPDMA QUEUED
|
||||
61 00 0a 00 70 00 00 00 08 c5 e8 40 08 00:21:12.723 WRITE FPDMA QUEUED
|
||||
|
||||
Error 4385 [0] occurred at disk power-on lifetime: 28040 hours (1168 days + 8 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
@@ -248,23 +265,6 @@ Error 4379 [18] occurred at disk power-on lifetime: 28040 hours (1168 days + 8 h
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 08 13:04:11.690 READ LOG EXT
|
||||
60 00 40 00 80 00 00 16 45 6f a8 40 08 13:04:09.967 READ FPDMA QUEUED
|
||||
|
||||
Error 4378 [17] occurred at disk power-on lifetime: 28040 hours (1168 days + 8 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 16 45 6f bc 40 00 Error: UNC at LBA = 0x16456fbc = 373649340
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 40 00 90 00 00 16 45 6f a8 40 08 13:04:11.690 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 08 13:04:11.690 READ LOG EXT
|
||||
60 00 40 00 80 00 00 16 45 6f a8 40 08 13:04:09.967 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 08 13:04:09.967 READ LOG EXT
|
||||
60 00 40 00 70 00 00 16 45 6f a8 40 08 13:04:08.248 READ FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 26659 -
|
||||
@@ -284,8 +284,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/31 Celsius
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/29 Celsius
|
||||
Lifetime Min/Max Temperature: 23/41 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -294,7 +294,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (314)
|
||||
Temperature History Size (Index): 478 (425)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -314,10 +314,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 17 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 6142 Vendor specific
|
||||
0x8000 4 1513 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Feb 22 21:50:56 2022 CET
|
||||
Local Time is: Thu Feb 24 13:43:09 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,15 +66,15 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 145 144 021 - 3716
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 84
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 85
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 079 079 000 - 15702
|
||||
9 Power_On_Hours -O--CK 079 079 000 - 15742
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 82
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 83
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 42
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 41
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 42
|
||||
194 Temperature_Celsius -O---K 117 102 000 - 26
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
@@ -133,8 +133,8 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/27 Celsius
|
||||
Lifetime Min/Max Temperature: 23/41 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/26 Celsius
|
||||
Lifetime Min/Max Temperature: 26/41 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (424)
|
||||
Temperature History Size (Index): 478 (420)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -162,10 +162,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 137292 Vendor specific
|
||||
0x8000 4 70653 Vendor specific
|
||||
|
||||
|
Reference in New Issue
Block a user