@@ -13,7 +13,7 @@ Rotation Rate: 10000 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Tue Dec 20 11:50:38 2022 EET
|
||||
Local Time is: Mon Dec 26 17:15:59 2022 EET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,20 +63,20 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 15
|
||||
3 Spin_Up_Time POS--K 211 210 021 - 2433
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 971
|
||||
3 Spin_Up_Time POS--K 212 210 021 - 2400
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 978
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 011 011 000 - 64990
|
||||
9 Power_On_Hours -O--CK 011 011 000 - 65041
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 927
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 934
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 079 059 040 - 21 (Min/Max 16/22)
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 229
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 741
|
||||
190 Airflow_Temperature_Cel -O---K 077 059 040 - 23 (Min/Max 18/23)
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 232
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 745
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -134,9 +134,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 21 Celsius
|
||||
Power Cycle Min/Max Temperature: 16/22 Celsius
|
||||
Lifetime Min/Max Temperature: 16/41 Celsius
|
||||
Current Temperature: 23 Celsius
|
||||
Power Cycle Min/Max Temperature: 18/23 Celsius
|
||||
Lifetime Min/Max Temperature: 18/41 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -144,7 +144,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (17)
|
||||
Temperature History Size (Index): 128 (19)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -165,5 +165,5 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 16918 Vendor specific
|
||||
0x8000 4 2791 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -10,7 +10,7 @@ User Capacity: 300,069,052,416 bytes [300 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Mon Jul 5 07:56:56 2021 EDT
|
||||
Local Time is: Sun Aug 22 11:28:54 2021 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 128 (quiet), recommended: 128
|
||||
@@ -62,16 +62,16 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 188 185 021 - 5566
|
||||
4 Start_Stop_Count -O--CK 085 085 000 - 15991
|
||||
3 Spin_Up_Time PO---- 189 185 021 - 5533
|
||||
4 Start_Stop_Count -O--CK 084 084 000 - 16041
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 075 075 000 - 18798
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 19226
|
||||
10 Spin_Retry_Count PO--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count PO--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 092 092 000 - 8556
|
||||
190 Airflow_Temperature_Cel -O---K 061 047 000 - 39
|
||||
194 Temperature_Celsius -O---K 111 097 000 - 39
|
||||
12 Power_Cycle_Count -O--CK 092 092 000 - 8606
|
||||
190 Airflow_Temperature_Cel -O---K 055 047 000 - 45
|
||||
194 Temperature_Celsius -O---K 105 097 000 - 45
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
@@ -125,8 +125,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: --/39 Celsius
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: --/46 Celsius
|
||||
Lifetime Min/Max Temperature: --/49 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -134,7 +134,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/65 Celsius
|
||||
Min/Max Temperature Limit: 1/70 Celsius
|
||||
Temperature History Size (Index): 128 (95)
|
||||
Temperature History Size (Index): 128 (13)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -147,8 +147,8 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 13864 Vendor specific
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 11729 Vendor specific
|
||||
|
||||
|
||||
|
||||
|