1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 14, modified: 3797)

This commit is contained in:
Andrey Ponomarenko
2023-02-14 02:15:20 +03:00
parent 274416644b
commit a41331e270
3811 changed files with 71570 additions and 67733 deletions

View File

@@ -13,7 +13,7 @@ Rotation Rate: 10000 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Tue Dec 20 11:50:38 2022 EET
Local Time is: Mon Dec 26 17:15:59 2022 EET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -63,20 +63,20 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 15
3 Spin_Up_Time POS--K 211 210 021 - 2433
4 Start_Stop_Count -O--CK 100 100 000 - 971
3 Spin_Up_Time POS--K 212 210 021 - 2400
4 Start_Stop_Count -O--CK 100 100 000 - 978
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-K 200 200 051 - 0
9 Power_On_Hours -O--CK 011 011 000 - 64990
9 Power_On_Hours -O--CK 011 011 000 - 65041
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 927
12 Power_Cycle_Count -O--CK 100 100 000 - 934
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 079 059 040 - 21 (Min/Max 16/22)
192 Power-Off_Retract_Count -O--CK 200 200 000 - 229
193 Load_Cycle_Count -O--CK 200 200 000 - 741
190 Airflow_Temperature_Cel -O---K 077 059 040 - 23 (Min/Max 18/23)
192 Power-Off_Retract_Count -O--CK 200 200 000 - 232
193 Load_Cycle_Count -O--CK 200 200 000 - 745
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
@@ -134,9 +134,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 21 Celsius
Power Cycle Min/Max Temperature: 16/22 Celsius
Lifetime Min/Max Temperature: 16/41 Celsius
Current Temperature: 23 Celsius
Power Cycle Min/Max Temperature: 18/23 Celsius
Lifetime Min/Max Temperature: 18/41 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
@@ -144,7 +144,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (17)
Temperature History Size (Index): 128 (19)
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
@@ -165,5 +165,5 @@ ID Size Value Description
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 16918 Vendor specific
0x8000 4 2791 Vendor specific