View File

@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Jun 13 10:04:18 2021 EDT
Local Time is: Thu Sep 2 13:28:20 2021 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 185 146 021 - 9750
4 Start_Stop_Count -O--CK 094 094 000 - 6431
3 Spin_Up_Time POS--K 178 146 021 - 10075
4 Start_Stop_Count -O--CK 094 094 000 - 6608
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 089 089 000 - 8193
9 Power_On_Hours -O--CK 089 089 000 - 8434
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 094 094 000 - 6335
192 Power-Off_Retract_Count -O--CK 200 200 000 - 308
193 Load_Cycle_Count -O--CK 198 198 000 - 6122
194 Temperature_Celsius -O---K 121 097 000 - 31
12 Power_Cycle_Count -O--CK 094 094 000 - 6512
192 Power-Off_Retract_Count -O--CK 200 200 000 - 316
193 Load_Cycle_Count -O--CK 198 198 000 - 6291
194 Temperature_Celsius -O---K 116 097 000 - 36
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
@@ -129,8 +129,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 31 Celsius
Power Cycle Min/Max Temperature: 28/31 Celsius
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 35/36 Celsius
Lifetime Min/Max Temperature: 0/55 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (223)
Temperature History Size (Index): 478 (70)
SCT Error Recovery Control command not supported
@@ -160,12 +160,12 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 378 Vendor specific
0x8000 4 736 Vendor specific