1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 14, modified: 3797)

This commit is contained in:
Andrey Ponomarenko
2023-02-14 02:15:20 +03:00
parent 274416644b
commit a41331e270
3811 changed files with 71570 additions and 67733 deletions

View File

@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Fri Feb 11 23:23:50 2022 EST
Local Time is: Wed Feb 16 00:14:42 2022 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
@@ -63,21 +63,21 @@ SCT capabilities: (0x303f) SCT Status supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 199 197 051 - 165865
3 Spin_Up_Time POS--K 154 141 021 - 3275
4 Start_Stop_Count -O--CK 098 098 000 - 2033
1 Raw_Read_Error_Rate POSR-K 199 197 051 - 166033
3 Spin_Up_Time POS--K 153 141 021 - 3333
4 Start_Stop_Count -O--CK 098 098 000 - 2039
5 Reallocated_Sector_Ct PO--CK 199 199 140 - 4
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 028 028 000 - 53052
9 Power_On_Hours -O--CK 028 028 000 - 53147
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1700
192 Power-Off_Retract_Count -O--CK 200 200 000 - 577
193 Load_Cycle_Count -O--CK 200 200 000 - 2033
194 Temperature_Celsius -O---K 100 083 000 - 43
12 Power_Cycle_Count -O--CK 099 099 000 - 1706
192 Power-Off_Retract_Count -O--CK 200 200 000 - 580
193 Load_Cycle_Count -O--CK 200 200 000 - 2039
194 Temperature_Celsius -O---K 099 083 000 - 44
196 Reallocated_Event_Count -O--CK 128 128 000 - 72
197 Current_Pending_Sector -O--CK 200 183 000 - 0
198 Offline_Uncorrectable ----CK 200 190 000 - 8
197 Current_Pending_Sector -O--CK 200 183 000 - 10
198 Offline_Uncorrectable ----CK 200 190 000 - 9
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 183 000 - 18
||||||_ K auto-keep
@@ -108,7 +108,7 @@ Address Access R/W Size Description
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 22729 (device log contains only the most recent 24 errors)
Device Error Count: 22875 (device log contains only the most recent 24 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
@@ -124,141 +124,141 @@ Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 22729 [8] occurred at disk power-on lifetime: 52914 hours (2204 days + 18 hours)
Error 22875 [10] occurred at disk power-on lifetime: 53139 hours (2214 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 01 ab 00 bd 18 40 00 Error: UNC at LBA = 0x1ab00bd18 = 7163919640
40 -- 51 00 00 00 01 7a 00 1b f3 40 00 Error: UNC at LBA = 0x17a001bf3 = 6341794803
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 80 00 00 01 bd ab 18 40 08 00:07:17.223 READ FPDMA QUEUED
60 00 20 00 78 00 00 00 0a 40 a0 40 08 00:07:17.212 READ FPDMA QUEUED
60 00 48 00 70 00 00 00 8f 7d b8 40 08 00:07:17.198 READ FPDMA QUEUED
60 00 80 00 68 00 00 00 8f 7d 38 40 08 00:07:17.198 READ FPDMA QUEUED
60 00 20 00 60 00 00 00 8f 7d 18 40 08 00:07:17.198 READ FPDMA QUEUED
60 01 00 00 b0 00 00 01 1b 7a 40 40 08 02:05:46.675 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 40 08 02:05:46.675 READ LOG EXT
60 01 00 00 a0 00 00 01 1b 7a 40 40 08 02:05:43.504 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 40 08 02:05:43.503 READ LOG EXT
60 01 00 00 90 00 00 01 1b 7a 40 40 08 02:05:40.498 READ FPDMA QUEUED
Error 22728 [7] occurred at disk power-on lifetime: 52914 hours (2204 days + 18 hours)
Error 22874 [9] occurred at disk power-on lifetime: 53139 hours (2214 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 01 ab 00 bd 18 40 00 Error: UNC at LBA = 0x1ab00bd18 = 7163919640
40 -- 51 00 00 00 01 7a 00 1b f3 40 00 Error: UNC at LBA = 0x17a001bf3 = 6341794803
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 88 00 00 01 bd ab 18 40 08 00:07:13.785 READ FPDMA QUEUED
60 00 20 00 f8 00 00 00 16 3e c0 40 08 00:07:13.785 READ FPDMA QUEUED
61 00 08 00 b8 00 00 03 3a f5 10 40 08 00:07:13.785 WRITE FPDMA QUEUED
61 00 68 00 b0 00 00 03 3a f4 98 40 08 00:07:13.785 WRITE FPDMA QUEUED
60 00 08 00 a8 00 00 01 bd a6 c8 40 08 00:07:13.785 READ FPDMA QUEUED
60 01 00 00 a0 00 00 01 1b 7a 40 40 08 02:05:43.504 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 40 08 02:05:43.503 READ LOG EXT
60 01 00 00 90 00 00 01 1b 7a 40 40 08 02:05:40.498 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 40 08 02:05:40.498 READ LOG EXT
60 01 00 00 80 00 00 01 1b 7a 40 40 08 02:05:37.327 READ FPDMA QUEUED
Error 22727 [6] occurred at disk power-on lifetime: 52914 hours (2204 days + 18 hours)
Error 22873 [8] occurred at disk power-on lifetime: 53139 hours (2214 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 01 ab 00 bd 18 40 00 Error: UNC at LBA = 0x1ab00bd18 = 7163919640
40 -- 51 00 00 00 01 7a 00 1b f3 40 00 Error: UNC at LBA = 0x17a001bf3 = 6341794803
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 04 88 00 d8 00 00 01 bd a6 a8 40 08 00:07:10.574 READ FPDMA QUEUED
60 04 88 00 d0 00 00 01 bd a2 20 40 08 00:07:10.569 READ FPDMA QUEUED
60 04 58 00 c8 00 00 01 bd 9d c8 40 08 00:07:10.544 READ FPDMA QUEUED
60 00 08 00 c0 00 00 01 bd 9d b0 40 08 00:07:10.543 READ FPDMA QUEUED
60 00 08 00 b8 00 00 01 bd 99 40 40 08 00:07:10.542 READ FPDMA QUEUED
60 01 00 00 90 00 00 01 1b 7a 40 40 08 02:05:40.498 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 40 08 02:05:40.498 READ LOG EXT
60 01 00 00 80 00 00 01 1b 7a 40 40 08 02:05:37.327 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 40 08 02:05:37.326 READ LOG EXT
61 00 08 00 70 00 00 24 f7 e7 90 40 08 02:05:34.097 WRITE FPDMA QUEUED
Error 22726 [5] occurred at disk power-on lifetime: 52914 hours (2204 days + 18 hours)
Error 22872 [7] occurred at disk power-on lifetime: 53139 hours (2214 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 fe 00 01 9c 00 bd 62 40 00 Error: UNC at LBA = 0x19c00bd62 = 6912261474
40 -- 51 00 00 00 01 7a 00 1b f3 40 00 Error: UNC at LBA = 0x17a001bf3 = 6341794803
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 04 a8 00 20 00 00 01 bd 99 20 40 08 00:07:06.937 READ FPDMA QUEUED
60 04 b8 00 18 00 00 01 bd 94 68 40 08 00:07:06.258 READ FPDMA QUEUED
60 02 78 00 10 00 00 01 bd 91 f0 40 08 00:07:06.255 READ FPDMA QUEUED
60 02 08 00 08 00 00 01 bd 8f e8 40 08 00:07:06.244 READ FPDMA QUEUED
60 02 28 00 00 00 00 01 bd 8d c0 40 08 00:07:06.242 READ FPDMA QUEUED
60 01 00 00 80 00 00 01 1b 7a 40 40 08 02:05:37.327 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 40 08 02:05:37.326 READ LOG EXT
61 00 08 00 70 00 00 24 f7 e7 90 40 08 02:05:34.097 WRITE FPDMA QUEUED
61 00 08 00 68 00 00 24 f7 e5 90 40 08 02:05:34.097 WRITE FPDMA QUEUED
61 00 08 00 60 00 00 00 08 23 90 40 08 02:05:34.097 WRITE FPDMA QUEUED
Error 22725 [4] occurred at disk power-on lifetime: 52914 hours (2204 days + 18 hours)
Error 22871 [6] occurred at disk power-on lifetime: 53139 hours (2214 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 01 ab 00 bd 18 40 00 Error: UNC at LBA = 0x1ab00bd18 = 7163919640
40 -- 51 00 00 00 01 7a 00 1b f3 40 00 Error: WP at LBA = 0x17a001bf3 = 6341794803
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 b0 00 00 01 bd ab 18 40 08 01:10:31.962 READ FPDMA QUEUED
61 00 08 00 70 00 00 00 77 37 38 40 08 01:10:31.091 WRITE FPDMA QUEUED
61 00 08 00 f0 00 00 02 7d be a0 40 08 01:10:29.773 WRITE FPDMA QUEUED
61 00 08 00 e8 00 00 02 7e e5 90 40 08 01:10:29.773 WRITE FPDMA QUEUED
61 00 08 00 e0 00 00 02 7e e5 78 40 08 01:10:29.772 WRITE FPDMA QUEUED
61 00 08 00 70 00 00 24 f7 e7 90 40 08 02:05:34.097 WRITE FPDMA QUEUED
61 00 08 00 68 00 00 24 f7 e5 90 40 08 02:05:34.097 WRITE FPDMA QUEUED
61 00 08 00 60 00 00 00 08 23 90 40 08 02:05:34.097 WRITE FPDMA QUEUED
61 00 08 00 58 00 00 00 08 21 90 40 08 02:05:34.097 WRITE FPDMA QUEUED
60 01 00 00 50 00 00 1f 23 7d 40 40 08 02:05:34.097 READ FPDMA QUEUED
Error 22724 [3] occurred at disk power-on lifetime: 52914 hours (2204 days + 18 hours)
Error 22870 [5] occurred at disk power-on lifetime: 53139 hours (2214 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 01 ab 00 bd 18 40 00 Error: UNC at LBA = 0x1ab00bd18 = 7163919640
40 -- 51 00 00 00 01 7a 00 1b f3 40 00 Error: UNC at LBA = 0x17a001bf3 = 6341794803
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 98 00 00 01 bd ab 18 40 08 01:09:42.200 READ FPDMA QUEUED
ea 00 00 00 00 00 00 00 00 00 00 e0 08 01:09:42.116 FLUSH CACHE EXT
61 00 28 00 70 00 00 02 ab 6e c8 40 08 01:09:42.116 WRITE FPDMA QUEUED
61 0a 00 00 80 00 00 03 3a c1 08 40 08 01:09:42.090 WRITE FPDMA QUEUED
61 0a 00 00 10 00 00 03 3a 5f 58 40 08 01:09:42.079 WRITE FPDMA QUEUED
60 04 00 00 a8 00 00 1f 23 66 40 40 08 02:05:30.459 READ FPDMA QUEUED
60 01 00 00 a0 00 00 1f 23 64 40 40 08 02:05:30.459 READ FPDMA QUEUED
60 08 00 00 98 00 00 01 1b 76 40 40 08 02:05:30.459 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 40 08 02:05:30.458 READ LOG EXT
60 04 00 00 88 00 00 1f 23 66 40 40 08 02:05:27.437 READ FPDMA QUEUED
Error 22723 [2] occurred at disk power-on lifetime: 52914 hours (2204 days + 18 hours)
Error 22869 [4] occurred at disk power-on lifetime: 53139 hours (2214 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 01 ab 00 bd 18 40 00 Error: UNC at LBA = 0x1ab00bd18 = 7163919640
40 -- 51 00 00 00 01 7a 00 1b f3 40 00 Error: UNC at LBA = 0x17a001bf3 = 6341794803
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 38 00 00 01 bd ab 18 40 08 01:09:38.837 READ FPDMA QUEUED
61 00 20 00 00 00 00 00 18 e7 a0 40 08 01:09:38.837 WRITE FPDMA QUEUED
61 00 08 00 18 00 00 02 60 1e 68 40 08 01:09:38.837 WRITE FPDMA QUEUED
61 0a 00 00 70 00 00 03 3a 4b 58 40 08 01:09:38.816 WRITE FPDMA QUEUED
61 04 30 00 30 00 00 03 2e f7 e0 40 08 01:09:38.814 WRITE FPDMA QUEUED
60 04 00 00 88 00 00 1f 23 66 40 40 08 02:05:27.437 READ FPDMA QUEUED
60 01 00 00 80 00 00 1f 23 64 40 40 08 02:05:27.437 READ FPDMA QUEUED
60 08 00 00 78 00 00 01 1b 76 40 40 08 02:05:27.437 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 40 08 02:05:27.436 READ LOG EXT
60 04 00 00 68 00 00 1f 23 66 40 40 08 02:05:24.090 READ FPDMA QUEUED
Error 22722 [1] occurred at disk power-on lifetime: 52914 hours (2204 days + 18 hours)
Error 22868 [3] occurred at disk power-on lifetime: 53139 hours (2214 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 01 ab 00 bd 18 40 00 Error: UNC at LBA = 0x1ab00bd18 = 7163919640
40 -- 51 00 00 00 01 7a 00 1b f3 40 00 Error: UNC at LBA = 0x17a001bf3 = 6341794803
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 90 00 00 01 bd ab 18 40 08 01:09:35.577 READ FPDMA QUEUED
61 00 20 00 18 00 00 00 18 e1 00 40 08 01:09:35.577 WRITE FPDMA QUEUED
ea 00 00 00 00 00 00 00 00 00 00 e0 08 01:09:35.551 FLUSH CACHE EXT
61 00 08 00 80 00 00 02 ef be 70 40 08 01:09:35.551 WRITE FPDMA QUEUED
61 00 08 00 f8 00 00 00 08 30 80 40 08 01:09:35.551 WRITE FPDMA QUEUED
60 04 00 00 68 00 00 1f 23 66 40 40 08 02:05:24.090 READ FPDMA QUEUED
60 01 00 00 60 00 00 1f 23 64 40 40 08 02:05:24.090 READ FPDMA QUEUED
60 08 00 00 58 00 00 01 1b 76 40 40 08 02:05:24.090 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 40 08 02:05:24.090 READ LOG EXT
60 04 00 00 48 00 00 1f 23 66 40 40 08 02:05:21.068 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
@@ -279,9 +279,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 43 Celsius
Power Cycle Min/Max Temperature: 22/44 Celsius
Lifetime Min/Max Temperature: 11/60 Celsius
Current Temperature: 44 Celsius
Power Cycle Min/Max Temperature: 34/45 Celsius
Lifetime Min/Max Temperature: 34/60 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
@@ -289,7 +289,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (121)
Temperature History Size (Index): 128 (87)
SCT Error Recovery Control:
Read: Disabled
@@ -308,6 +308,6 @@ ID Size Value Description
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
0x8000 4 104540 Vendor specific
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x8000 4 10611 Vendor specific

View File

@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Fri Mar 12 11:27:29 2021 EST
Local Time is: Fri Mar 12 14:06:21 2021 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 128
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 138 129 021 - 4100
4 Start_Stop_Count -O--CK 098 098 000 - 2795
3 Spin_Up_Time POS--K 137 129 021 - 4125
4 Start_Stop_Count -O--CK 098 098 000 - 2796
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 050 050 000 - 37028
9 Power_On_Hours -O--CK 050 050 000 - 37031
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 724
192 Power-Off_Retract_Count -O--CK 200 200 000 - 179
193 Load_Cycle_Count -O--CK 200 200 000 - 773
194 Temperature_Celsius -O---K 101 080 000 - 42
12 Power_Cycle_Count -O--CK 100 100 000 - 725
192 Power-Off_Retract_Count -O--CK 200 200 000 - 180
193 Load_Cycle_Count -O--CK 200 200 000 - 774
194 Temperature_Celsius -O---K 103 080 000 - 40
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
@@ -146,8 +146,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 40 Celsius
Power Cycle Min/Max Temperature: 23/40 Celsius
Current Temperature: 42 Celsius
Power Cycle Min/Max Temperature: 42/42 Celsius
Lifetime Min/Max Temperature: ?/63 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -156,7 +156,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 255 minutes
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (13)
Temperature History Size (Index): 478 (15)
SCT Error Recovery Control command not supported
@@ -173,8 +173,8 @@ ID Size Value Description
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x8000 4 45408 Vendor specific
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x8000 4 9359 Vendor specific

View File

@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Sat Feb 11 20:36:56 2023 UTC
Local Time is: Sat Feb 11 21:36:07 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 128
@@ -67,21 +67,21 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
4 Start_Stop_Count -O--CK 098 098 000 - 2089
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
9 Power_On_Hours -O--CK 041 041 000 - 43157
9 Power_On_Hours -O--CK 041 041 000 - 43158
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1976
192 Power-Off_Retract_Count -O--CK 200 200 000 - 111
193 Load_Cycle_Count -O--CK 200 200 000 - 2089
194 Temperature_Celsius -O---K 104 091 000 - 39
194 Temperature_Celsius -O---K 100 091 000 - 43
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
240 Head_Flying_Hours -O--CK 044 044 000 - 40909
241 Total_LBAs_Written -O--CK 200 200 000 - 28040566056
242 Total_LBAs_Read -O--CK 200 200 000 - 79181769872
240 Head_Flying_Hours -O--CK 044 044 000 - 40910
241 Total_LBAs_Written -O--CK 200 200 000 - 28045339252
242 Total_LBAs_Read -O--CK 200 200 000 - 79184128493
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -131,9 +131,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 39 Celsius
Power Cycle Min/Max Temperature: 39/39 Celsius
Lifetime Min/Max Temperature: 39/47 Celsius
Current Temperature: 43 Celsius
Power Cycle Min/Max Temperature: 38/43 Celsius
Lifetime Min/Max Temperature: 38/47 Celsius
Specified Max Operating Temperature: 38 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (337)
Temperature History Size (Index): 478 (393)
SCT Error Recovery Control command not supported
@@ -159,6 +159,6 @@ ID Size Value Description
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x8000 4 366 Vendor specific
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
0x8000 4 3914 Vendor specific

View File

@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Thu Jan 26 09:41:56 2023 +07
Local Time is: Thu Jan 26 13:14:39 2023 +07
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -67,13 +67,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
4 Start_Stop_Count -O--CK 095 095 000 - 5936
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 093 093 000 - 5685
9 Power_On_Hours -O--CK 093 093 000 - 5689
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 095 095 000 - 5927
192 Power-Off_Retract_Count -O--CK 200 200 000 - 141
193 Load_Cycle_Count -O--CK 199 199 000 - 5794
194 Temperature_Celsius -O---K 105 098 000 - 38
194 Temperature_Celsius -O---K 104 098 000 - 39
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 1
198 Offline_Uncorrectable ----CK 200 200 000 - 3
@@ -289,7 +289,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (8)
Temperature History Size (Index): 478 (220)
SCT Error Recovery Control command not supported
@@ -308,5 +308,5 @@ ID Size Value Description
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 150886 Vendor specific
0x8000 4 163636 Vendor specific

View File

@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Thu Jun 9 15:10:50 2022 PST
Local Time is: Mon Jun 13 20:25:12 2022 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,23 +65,23 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 993
3 Spin_Up_Time POS--K 163 157 021 - 825
4 Start_Stop_Count -O--CK 097 097 000 - 3034
3 Spin_Up_Time POS--K 163 157 021 - 850
4 Start_Stop_Count -O--CK 097 097 000 - 3075
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-K 100 253 051 - 0
9 Power_On_Hours -O--CK 079 079 000 - 15596
7 Seek_Error_Rate POSR-K 200 200 051 - 0
9 Power_On_Hours -O--CK 079 079 000 - 15654
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 097 097 000 - 3021
12 Power_Cycle_Count -O--CK 097 097 000 - 3062
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 001 000 - 992
188 Command_Timeout -O--CK 100 021 000 - 21475230658
190 Airflow_Temperature_Cel -O---K 044 037 040 Past 56 (Min/Max 56/56 #35)
190 Airflow_Temperature_Cel -O---K 042 037 040 Past 58 (Min/Max 54/60 #35)
191 G-Sense_Error_Rate -O--CK 001 001 000 - 3590
192 Power-Off_Retract_Count -O--CK 200 200 000 - 509
193 Load_Cycle_Count -O--CK 185 185 000 - 45141
194 Temperature_Celsius -O---K 087 080 000 - 56
192 Power-Off_Retract_Count -O--CK 200 200 000 - 521
193 Load_Cycle_Count -O--CK 185 185 000 - 47084
194 Temperature_Celsius -O---K 085 080 000 - 58
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
@@ -285,8 +285,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 56 Celsius
Power Cycle Min/Max Temperature: 56/56 Celsius
Current Temperature: 57 Celsius
Power Cycle Min/Max Temperature: 54/60 Celsius
Lifetime Min/Max Temperature: 0/63 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
@@ -298,7 +298,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (9)
Temperature History Size (Index): 128 (87)
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
@@ -319,7 +319,7 @@ ID Size Value Description
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 255 Vendor specific
0x8000 4 13202 Vendor specific

View File

@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Fri Jun 18 11:23:40 2021 EDT
Local Time is: Fri Jun 18 09:34:07 2021 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -68,7 +68,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
4 Start_Stop_Count -O--CK 099 099 000 - 1368
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-K 100 253 051 - 0
9 Power_On_Hours -O--CK 080 080 000 - 15236
9 Power_On_Hours -O--CK 080 080 000 - 15237
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1361
@@ -76,11 +76,11 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 099 099 000 - 4295032833
190 Airflow_Temperature_Cel -O---K 071 045 040 - 29 (Min/Max 27/29)
190 Airflow_Temperature_Cel -O---K 067 045 040 - 33 (Min/Max 27/35)
191 G-Sense_Error_Rate -O--CK 001 001 000 - 1298
192 Power-Off_Retract_Count -O--CK 200 200 000 - 247
193 Load_Cycle_Count -O--CK 047 047 000 - 461636
194 Temperature_Celsius -O---K 114 088 000 - 29
193 Load_Cycle_Count -O--CK 047 047 000 - 461643
194 Temperature_Celsius -O---K 110 088 000 - 33
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
@@ -134,8 +134,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 28 Celsius
Power Cycle Min/Max Temperature: 27/29 Celsius
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 27/35 Celsius
Lifetime Min/Max Temperature: 0/55 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
@@ -147,7 +147,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (24)
Temperature History Size (Index): 128 (92)
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
@@ -168,5 +168,5 @@ ID Size Value Description
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 283 Vendor specific
0x8000 4 4507 Vendor specific

View File

@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Sat Mar 13 07:39:44 2021 EST
Local Time is: Sat Mar 13 07:40:22 2021 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -77,7 +77,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
190 Airflow_Temperature_Cel -O---K 070 052 040 - 30
191 G-Sense_Error_Rate -O--CK 059 059 000 - 41
192 Power-Off_Retract_Count -O--CK 200 200 000 - 45
193 Load_Cycle_Count -O--CK 115 115 000 - 257935
193 Load_Cycle_Count -O--CK 115 115 000 - 257937
194 Temperature_Celsius -O---K 117 099 000 - 30
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
@@ -281,8 +281,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 29 Celsius
Power Cycle Min/Max Temperature: 22/29 Celsius
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 22/30 Celsius
Lifetime Min/Max Temperature: 14/49 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
@@ -294,7 +294,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (98)
Temperature History Size (Index): 128 (99)
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
@@ -314,5 +314,5 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x8000 4 743 Vendor specific
0x8000 4 781 Vendor specific

View File

@@ -1,4 +1,4 @@
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue May 17 11:42:10 2022 EDT
Local Time is: Wed May 18 14:59:04 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,22 +65,22 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 166 141 021 - 666
4 Start_Stop_Count -O--CK 097 097 000 - 3696
4 Start_Stop_Count -O--CK 097 097 000 - 3700
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-K 100 253 051 - 0
9 Power_On_Hours -O--CK 082 082 000 - 13537
9 Power_On_Hours -O--CK 082 082 000 - 13544
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 097 097 000 - 3508
12 Power_Cycle_Count -O--CK 097 097 000 - 3512
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 098 000 - 16
190 Airflow_Temperature_Cel -O---K 063 048 040 - 37 (Min/Max 26/37)
190 Airflow_Temperature_Cel -O---K 066 048 040 - 34 (Min/Max 24/34)
191 G-Sense_Error_Rate -O--CK 001 001 000 - 1370
192 Power-Off_Retract_Count -O--CK 200 200 000 - 209
193 Load_Cycle_Count -O--CK 190 190 000 - 30594
194 Temperature_Celsius -O---K 106 091 000 - 37
193 Load_Cycle_Count -O--CK 190 190 000 - 30623
194 Temperature_Celsius -O---K 109 091 000 - 34
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
@@ -134,8 +134,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: --/37 Celsius
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: --/34 Celsius
Lifetime Min/Max Temperature: --/53 Celsius
SCT Temperature History Version: 2
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (43)
Temperature History Size (Index): 128 (89)
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
@@ -163,12 +163,12 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 11 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 3103 Vendor specific
0x8000 4 1110 Vendor specific

View File

@@ -1,4 +1,4 @@
smartctl 7.1 2019-12-30 r5022 [i386-unknown-openbsd6.8] (local build)
smartctl 7.1 2019-12-30 r5022 [i386-unknown-openbsd6.9] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5
Local Time is: Mon Oct 19 18:30:27 2020 EDT
Local Time is: Sun May 16 21:15:17 2021 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
@@ -58,16 +58,16 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0027 186 185 021 Pre-fail Always - 1675
4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 1662
4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 1771
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 481
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 508
10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 452
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 470
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 57
193 Load_Cycle_Count 0x0032 198 198 000 Old_age Always - 6881
194 Temperature_Celsius 0x0022 109 093 000 Old_age Always - 38
193 Load_Cycle_Count 0x0032 198 198 000 Old_age Always - 7256
194 Temperature_Celsius 0x0022 107 093 000 Old_age Always - 40
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0

View File

@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Tue Mar 29 22:53:10 2022 GMT
Local Time is: Mon May 16 13:31:56 2022 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
@@ -64,18 +64,18 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 1
3 Spin_Up_Time POS--K 154 130 021 - 1283
4 Start_Stop_Count -O--CK 062 062 000 - 38144
3 Spin_Up_Time POS--K 155 130 021 - 1250
4 Start_Stop_Count -O--CK 060 060 000 - 40774
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 084 084 000 - 11979
7 Seek_Error_Rate -OSR-K 200 200 000 - 2
9 Power_On_Hours -O--CK 083 083 000 - 12519
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 095 095 000 - 5022
191 G-Sense_Error_Rate -O--CK 001 001 000 - 6489
192 Power-Off_Retract_Count -O--CK 200 200 000 - 625
193 Load_Cycle_Count -O--CK 001 001 000 - 1754031
194 Temperature_Celsius -O---K 105 095 000 - 38
12 Power_Cycle_Count -O--CK 095 095 000 - 5026
191 G-Sense_Error_Rate -O--CK 001 001 000 - 11363
192 Power-Off_Retract_Count -O--CK 200 200 000 - 629
193 Load_Cycle_Count -O--CK 001 001 000 - 1775580
194 Temperature_Celsius -O---K 111 095 000 - 32
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
@@ -282,9 +282,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 38 Celsius
Power Cycle Min/Max Temperature: 27/38 Celsius
Lifetime Min/Max Temperature: 37/51 Celsius
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 27/35 Celsius
Lifetime Min/Max Temperature: 24/51 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
@@ -295,7 +295,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (27)
Temperature History Size (Index): 128 (73)
SCT Error Recovery Control command not supported
@@ -312,7 +312,7 @@ ID Size Value Description
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 52930 Vendor specific
0x8000 4 191671 Vendor specific

View File

@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sat Sep 11 14:34:56 2021 EDT
Local Time is: Mon Sep 20 13:58:01 2021 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,18 +64,18 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 145 140 021 - 1750
4 Start_Stop_Count -O--CK 071 071 000 - 29556
3 Spin_Up_Time POS--K 141 140 021 - 1950
4 Start_Stop_Count -O--CK 071 071 000 - 29835
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 096 096 000 - 3275
9 Power_On_Hours -O--CK 096 096 000 - 3307
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1558
12 Power_Cycle_Count -O--CK 099 099 000 - 1637
191 G-Sense_Error_Rate -O--CK 050 050 000 - 50
192 Power-Off_Retract_Count -O--CK 200 200 000 - 77
193 Load_Cycle_Count -O--CK 030 030 000 - 511210
194 Temperature_Celsius -O---K 099 087 000 - 44
192 Power-Off_Retract_Count -O--CK 200 200 000 - 124
193 Load_Cycle_Count -O--CK 029 029 000 - 514763
194 Temperature_Celsius -O---K 095 087 000 - 48
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
@@ -129,8 +129,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 44 Celsius
Power Cycle Min/Max Temperature: 24/44 Celsius
Current Temperature: 48 Celsius
Power Cycle Min/Max Temperature: 46/48 Celsius
Lifetime Min/Max Temperature: 16/56 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (72)
Temperature History Size (Index): 128 (8)
SCT Error Recovery Control command not supported
@@ -160,10 +160,10 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x0009 2 13 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 2350 Vendor specific
0x8000 4 1787 Vendor specific

View File

@@ -1,4 +1,4 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sat Jun 18 16:43:05 2022 +03
Local Time is: Sat Jul 16 17:13:12 2022 +03
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,17 +65,17 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 145 137 021 - 1750
4 Start_Stop_Count -O--CK 054 054 000 - 46466
4 Start_Stop_Count -O--CK 053 053 000 - 47103
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 091 091 000 - 6619
9 Power_On_Hours -O--CK 091 091 000 - 6717
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 094 094 000 - 6222
191 G-Sense_Error_Rate -O--CK 001 001 000 - 10171
192 Power-Off_Retract_Count -O--CK 200 200 000 - 402
193 Load_Cycle_Count -O--CK 001 001 000 - 948114
194 Temperature_Celsius -O---K 108 092 000 - 35
12 Power_Cycle_Count -O--CK 094 094 000 - 6271
191 G-Sense_Error_Rate -O--CK 001 001 000 - 10716
192 Power-Off_Retract_Count -O--CK 200 200 000 - 419
193 Load_Cycle_Count -O--CK 001 001 000 - 982905
194 Temperature_Celsius -O---K 109 092 000 - 34
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
@@ -129,8 +129,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 24/35 Celsius
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: 27/34 Celsius
Lifetime Min/Max Temperature: 11/51 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (41)
Temperature History Size (Index): 128 (101)
SCT Error Recovery Control command not supported
@@ -161,9 +161,9 @@ ID Size Value Description
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 5388 Vendor specific
0x8000 4 4115 Vendor specific

View File

@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Tue Feb 2 18:36:15 2021 CET
Local Time is: Wed Feb 3 00:08:42 2021 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,17 +65,17 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 120 120 021 - 3000
4 Start_Stop_Count -O--CK 001 001 000 - 452336
4 Start_Stop_Count -O--CK 001 001 000 - 452729
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 093 093 000 - 5199
9 Power_On_Hours -O--CK 093 093 000 - 5204
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 75
191 G-Sense_Error_Rate -O--CK 070 070 000 - 30
191 G-Sense_Error_Rate -O--CK 069 069 000 - 31
192 Power-Off_Retract_Count -O--CK 200 200 000 - 54
193 Load_Cycle_Count -O--CK 001 001 000 - 826555
194 Temperature_Celsius -O---K 102 092 000 - 41
193 Load_Cycle_Count -O--CK 001 001 000 - 827579
194 Temperature_Celsius -O---K 101 092 000 - 42
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
@@ -130,7 +130,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 41 Celsius
Current Temperature: 42 Celsius
Power Cycle Min/Max Temperature: 19/43 Celsius
Lifetime Min/Max Temperature: 0/51 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (8)
Temperature History Size (Index): 128 (101)
SCT Error Recovery Control command not supported
@@ -166,5 +166,5 @@ ID Size Value Description
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 10204695 Vendor specific
0x8000 4 10224623 Vendor specific

View File

@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sat Jan 2 19:24:04 2021 +05
Local Time is: Sat Jan 2 19:26:27 2021 +05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
@@ -69,7 +69,7 @@ ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_
12 Power_Cycle_Count 0x0032 098 098 000 Old_age Always - 2388
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 113
193 Load_Cycle_Count 0x0032 176 176 000 Old_age Always - 74708
194 Temperature_Celsius 0x0022 118 096 000 Old_age Always - 25
194 Temperature_Celsius 0x0022 117 096 000 Old_age Always - 26
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0

View File

@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Fri Jul 23 12:43:44 2021 +0430
Local Time is: Fri Jul 23 17:24:52 2021 +0430
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 128
@@ -64,26 +64,26 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 16
3 Spin_Up_Time POS--K 153 147 021 - 1333
4 Start_Stop_Count -O--CK 095 095 000 - 5331
3 Spin_Up_Time POS--K 153 147 021 - 1316
4 Start_Stop_Count -O--CK 095 095 000 - 5332
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 088 088 000 - 9166
9 Power_On_Hours -O--CK 088 088 000 - 9170
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 095 095 000 - 5176
191 G-Sense_Error_Rate -O--CK 001 001 000 - 73674
12 Power_Cycle_Count -O--CK 095 095 000 - 5177
191 G-Sense_Error_Rate -O--CK 001 001 000 - 73692
192 Power-Off_Retract_Count -O--CK 200 200 000 - 638
193 Load_Cycle_Count -O--CK 001 001 000 - 1058886
194 Temperature_Celsius -O---K 102 074 000 - 41
193 Load_Cycle_Count -O--CK 001 001 000 - 1059335
194 Temperature_Celsius -O---K 087 074 000 - 56
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
240 Head_Flying_Hours -O--CK 092 092 000 - 6461
241 Total_LBAs_Written -O--CK 200 200 000 - 17775188826
242 Total_LBAs_Read -O--CK 200 200 000 - 34765923982
240 Head_Flying_Hours -O--CK 092 092 000 - 6463
241 Total_LBAs_Written -O--CK 200 200 000 - 17778479676
242 Total_LBAs_Read -O--CK 200 200 000 - 34803967977
254 Free_Fall_Sensor -O--CK 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
@@ -291,8 +291,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 41 Celsius
Power Cycle Min/Max Temperature: 36/41 Celsius
Current Temperature: 56 Celsius
Power Cycle Min/Max Temperature: 41/58 Celsius
Lifetime Min/Max Temperature: 37/69 Celsius
Specified Max Operating Temperature: 35 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -305,7 +305,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (34)
Temperature History Size (Index): 128 (20)
SCT Error Recovery Control command not supported
@@ -324,5 +324,5 @@ ID Size Value Description
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 434 Vendor specific
0x8000 4 4990 Vendor specific

View File

@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Mon Feb 15 01:06:40 2021 CST
Local Time is: Tue Feb 16 04:13:20 2021 CST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
@@ -64,26 +64,26 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 154 137 021 - 1300
4 Start_Stop_Count -O--CK 099 099 000 - 1941
3 Spin_Up_Time POS--K 154 137 021 - 1291
4 Start_Stop_Count -O--CK 099 099 000 - 1948
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 088 088 000 - 9246
9 Power_On_Hours -O--CK 088 088 000 - 9263
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1913
191 G-Sense_Error_Rate -O--CK 001 001 000 - 56487
12 Power_Cycle_Count -O--CK 099 099 000 - 1920
191 G-Sense_Error_Rate -O--CK 001 001 000 - 56506
192 Power-Off_Retract_Count -O--CK 200 200 000 - 426
193 Load_Cycle_Count -O--CK 122 122 000 - 235248
194 Temperature_Celsius -O---K 102 081 000 - 41
193 Load_Cycle_Count -O--CK 122 122 000 - 236526
194 Temperature_Celsius -O---K 103 081 000 - 40
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
240 Head_Flying_Hours -O--CK 091 091 000 - 6617
241 Total_LBAs_Written -O--CK 200 200 000 - 29627469945
242 Total_LBAs_Read -O--CK 200 200 000 - 36425457874
240 Head_Flying_Hours -O--CK 091 091 000 - 6633
241 Total_LBAs_Written -O--CK 200 200 000 - 29693999189
242 Total_LBAs_Read -O--CK 200 200 000 - 36437756926
254 Free_Fall_Sensor -O--CK 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
@@ -221,8 +221,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 41 Celsius
Power Cycle Min/Max Temperature: 38/42 Celsius
Current Temperature: 40 Celsius
Power Cycle Min/Max Temperature: 36/42 Celsius
Lifetime Min/Max Temperature: ?/63 Celsius
Specified Max Operating Temperature: 29 Celsius
Under/Over Temperature Limit Count: 0/0
@@ -235,7 +235,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (61)
Temperature History Size (Index): 128 (48)
SCT Error Recovery Control command not supported
@@ -252,7 +252,7 @@ ID Size Value Description
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 27 Device-to-host register FISes sent due to a COMRESET
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 19677 Vendor specific
0x8000 4 10417 Vendor specific

View File

@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Mon Oct 3 11:45:55 2022 CEST
Local Time is: Thu Oct 20 20:13:54 2022 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -64,18 +64,18 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 199 051 - 0
3 Spin_Up_Time POS--K 142 129 021 - 1900
4 Start_Stop_Count -O--CK 035 035 000 - 65537
3 Spin_Up_Time POS--K 141 129 021 - 1908
4 Start_Stop_Count -O--CK 034 034 000 - 66831
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 096 096 000 - 3018
9 Power_On_Hours -O--CK 096 096 000 - 3071
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1235
191 G-Sense_Error_Rate -O--CK 001 001 000 - 114
12 Power_Cycle_Count -O--CK 099 099 000 - 1268
191 G-Sense_Error_Rate -O--CK 001 001 000 - 117
192 Power-Off_Retract_Count -O--CK 200 200 000 - 324
193 Load_Cycle_Count -O--CK 089 089 000 - 333073
194 Temperature_Celsius -O---K 110 099 000 - 33
193 Load_Cycle_Count -O--CK 086 086 000 - 342905
194 Temperature_Celsius -O---K 113 099 000 - 30
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
@@ -279,8 +279,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 17/34 Celsius
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 18/30 Celsius
Lifetime Min/Max Temperature: 5/44 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
@@ -292,7 +292,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (73)
Temperature History Size (Index): 128 (47)
SCT Error Recovery Control command not supported
@@ -310,10 +310,10 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 11887 Vendor specific
0x8000 4 1192 Vendor specific

View File

@@ -12,7 +12,7 @@ Rotation Rate: 5400 rpm
Device is: Not in smartctl database 7.3/5319
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Jan 16 21:18:47 2023 UTC
Local Time is: Mon Jan 16 22:04:37 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -63,18 +63,18 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 156 148 021 - 1175
4 Start_Stop_Count -O--CK 100 100 000 - 330
3 Spin_Up_Time POS--K 158 148 021 - 1100
4 Start_Stop_Count -O--CK 100 100 000 - 337
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 048 048 000 - 38058
9 Power_On_Hours -O--CK 048 048 000 - 38059
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 195
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
192 Power-Off_Retract_Count -O--CK 200 200 000 - 55
193 Load_Cycle_Count -O--CK 192 192 000 - 24724
194 Temperature_Celsius -O---K 115 092 000 - 28
193 Load_Cycle_Count -O--CK 192 192 000 - 24819
194 Temperature_Celsius -O---K 110 092 000 - 33
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
@@ -129,8 +129,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 28 Celsius
Power Cycle Min/Max Temperature: 24/28 Celsius
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 24/33 Celsius
Lifetime Min/Max Temperature: 0/52 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (19)
Temperature History Size (Index): 128 (79)
SCT Error Recovery Control command not supported
@@ -165,5 +165,5 @@ ID Size Value Description
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 522 Vendor specific
0x8000 4 3269 Vendor specific

View File

@@ -1,5 +1,5 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: WDC WD3200LPVX-60V0TT0
@@ -10,10 +10,10 @@ User Capacity: 320,072,933,376 bytes [320 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: Not in smartctl database [for details use: -P showall]
Device is: Not in smartctl database 7.3/5319
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Mar 21 18:44:34 2022 JST
Local Time is: Fri Mar 25 21:16:13 2022 JST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -62,23 +62,23 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 150 146 021 - 1458
4 Start_Stop_Count -O--CK 099 099 000 - 1057
3 Spin_Up_Time POS--K 150 146 021 - 1483
4 Start_Stop_Count -O--CK 099 099 000 - 1059
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-K 200 200 051 - 0
9 Power_On_Hours -O--CK 080 080 000 - 15159
9 Power_On_Hours -O--CK 080 080 000 - 15206
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 963
12 Power_Cycle_Count -O--CK 100 100 000 - 965
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 099 099 000 - 3
190 Airflow_Temperature_Cel -O---K 072 052 040 - 28 (Min/Max 27/28)
190 Airflow_Temperature_Cel -O---K 073 052 040 - 27 (Min/Max 24/27)
191 G-Sense_Error_Rate -O--CK 001 001 000 - 210
192 Power-Off_Retract_Count -O--CK 200 200 000 - 74
193 Load_Cycle_Count -O--CK 079 079 000 - 365613
194 Temperature_Celsius -O---K 115 095 000 - 28
192 Power-Off_Retract_Count -O--CK 200 200 000 - 76
193 Load_Cycle_Count -O--CK 079 079 000 - 365867
194 Temperature_Celsius -O---K 116 095 000 - 27
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
@@ -136,8 +136,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 28 Celsius
Power Cycle Min/Max Temperature: 27/28 Celsius
Current Temperature: 27 Celsius
Power Cycle Min/Max Temperature: 16/28 Celsius
Lifetime Min/Max Temperature: 14/48 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
@@ -149,7 +149,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (84)
Temperature History Size (Index): 128 (55)
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
@@ -169,12 +169,12 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 68 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 66 Device-to-host register FISes sent due to a COMRESET
0x0009 2 32 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 32 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 11328 Vendor specific
0x8000 4 81309 Vendor specific

View File

@@ -13,7 +13,7 @@ Form Factor: 2.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Dec 9 12:45:17 2022 EST
Local Time is: Mon Jan 9 11:29:04 2023 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -63,22 +63,22 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 155 149 021 - 1241
4 Start_Stop_Count -O--CK 098 098 000 - 2963
3 Spin_Up_Time POS--K 155 149 021 - 1233
4 Start_Stop_Count -O--CK 096 096 000 - 4819
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-K 200 200 051 - 0
9 Power_On_Hours -O--CK 097 097 000 - 2670
9 Power_On_Hours -O--CK 096 096 000 - 2942
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 2304
12 Power_Cycle_Count -O--CK 098 098 000 - 2491
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 098 000 - 10
190 Airflow_Temperature_Cel -O---K 069 055 040 - 31 (Min/Max 30/31)
191 G-Sense_Error_Rate -O--CK 001 001 000 - 265
192 Power-Off_Retract_Count -O--CK 200 200 000 - 49
193 Load_Cycle_Count -O--CK 182 182 000 - 56162
188 Command_Timeout -O--CK 100 098 000 - 12
190 Airflow_Temperature_Cel -O---K 069 055 040 - 31 (Min/Max 31/31)
191 G-Sense_Error_Rate -O--CK 001 001 000 - 273
192 Power-Off_Retract_Count -O--CK 200 200 000 - 72
193 Load_Cycle_Count -O--CK 180 180 000 - 62458
194 Temperature_Celsius -O---K 112 098 000 - 31
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
@@ -144,7 +144,7 @@ SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 31 Celsius
Power Cycle Min/Max Temperature: 30/31 Celsius
Power Cycle Min/Max Temperature: 31/31 Celsius
Lifetime Min/Max Temperature: 9/45 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
@@ -156,7 +156,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (113)
Temperature History Size (Index): 128 (98)
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
@@ -181,5 +181,5 @@ ID Size Value Description
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 1418 Vendor specific
0x8000 4 338 Vendor specific