mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 14, modified: 3797)
This commit is contained in:
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p20-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Caviar Blue (SATA)
|
||||
@@ -10,10 +10,10 @@ Firmware Version: 12.01C02
|
||||
User Capacity: 400,088,457,216 bytes [400 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Wed Oct 6 09:22:44 2021 PDT
|
||||
Local Time is: Sat May 7 12:19:26 2022 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 128
|
||||
@@ -65,20 +65,20 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 308
|
||||
3 Spin_Up_Time PO---- 178 176 021 - 6083
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3428
|
||||
3 Spin_Up_Time PO---- 183 176 021 - 5816
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3442
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-- 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 75651
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 79661
|
||||
10 Spin_Retry_Count -O--C- 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2350
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 437
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 3678
|
||||
194 Temperature_Celsius -O---K 113 085 000 - 37
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2364
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 453
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 3695
|
||||
194 Temperature_Celsius -O---K 119 085 000 - 31
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 10
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 15
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 16
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 1006
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 1
|
||||
||||||_ K auto-keep
|
||||
@@ -270,8 +270,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/39 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/34 Celsius
|
||||
Lifetime Min/Max Temperature: 22/65 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -280,7 +280,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/85 Celsius
|
||||
Temperature History Size (Index): 128 (120)
|
||||
Temperature History Size (Index): 128 (84)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -299,6 +299,6 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 1708975 Vendor specific
|
||||
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 2342986 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jan 24 18:24:07 2023 MSK
|
||||
Local Time is: Sat Jan 28 10:15:09 2023 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 162 139 021 - 10866
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4005
|
||||
3 Spin_Up_Time POS--K 156 139 021 - 11175
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4022
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 082 082 000 - 13722
|
||||
9 Power_On_Hours -O--CK 082 082 000 - 13756
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 4005
|
||||
16 Total_LBAs_Read -O---K 007 193 000 - 388191609018
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 4022
|
||||
16 Total_LBAs_Read -O---K 007 193 000 - 390719411858
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 114
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 4038
|
||||
194 Temperature_Celsius -O---K 109 103 000 - 43
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 117
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 4052
|
||||
194 Temperature_Celsius -O---K 126 103 000 - 26
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -135,8 +135,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 43 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/43 Celsius
|
||||
Current Temperature: 25 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/25 Celsius
|
||||
Lifetime Min/Max Temperature: 17/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -148,7 +148,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (55)
|
||||
Temperature History Size (Index): 478 (207)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -174,7 +174,7 @@ ID Size Value Description
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 29105 Vendor specific
|
||||
0x8000 4 291 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Dec 13 16:51:00 2022 EST
|
||||
Local Time is: Mon Jan 23 16:08:41 2023 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 253 223 021 - 6116
|
||||
4 Start_Stop_Count -O--CK 088 088 000 - 12193
|
||||
3 Spin_Up_Time POS--K 253 223 021 - 4825
|
||||
4 Start_Stop_Count -O--CK 088 088 000 - 12199
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 086 086 000 - 10270
|
||||
9 Power_On_Hours -O--CK 086 086 000 - 10658
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 091 091 000 - 9978
|
||||
16 Total_LBAs_Read -O---K 000 200 000 - 14049279990
|
||||
12 Power_Cycle_Count -O--CK 091 091 000 - 9984
|
||||
16 Total_LBAs_Read -O---K 000 200 000 - 14049348497
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 191 191 000 - 7432
|
||||
192 Power-Off_Retract_Count -O--CK 191 191 000 - 7438
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 4764
|
||||
194 Temperature_Celsius -O---K 116 084 000 - 36
|
||||
194 Temperature_Celsius -O---K 117 084 000 - 35
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -138,8 +138,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/36 Celsius
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 34/35 Celsius
|
||||
Lifetime Min/Max Temperature: 19/67 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -151,7 +151,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (270)
|
||||
Temperature History Size (Index): 478 (105)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -171,13 +171,13 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 361 Vendor specific
|
||||
0x8000 4 8547 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
Reference in New Issue