mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 14, modified: 3797)
This commit is contained in:
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Wed Nov 2 03:00:29 2022 UTC
|
||||
Local Time is: Thu Nov 3 13:06:08 2022 KST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -20,7 +20,7 @@ APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
@@ -64,16 +64,16 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 171 159 021 - 4441
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 294
|
||||
3 Spin_Up_Time POS--K 161 159 021 - 4933
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 298
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 034 034 000 - 48207
|
||||
9 Power_On_Hours -O--CK 034 034 000 - 48215
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 279
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 258
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 293
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 283
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 260
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 297
|
||||
194 Temperature_Celsius -O---K 105 100 000 - 42
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
@@ -128,8 +128,8 @@ SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 42 Celsius
|
||||
Power Cycle Min/Max Temperature: 34/42 Celsius
|
||||
Lifetime Min/Max Temperature: 26/48 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/43 Celsius
|
||||
Lifetime Min/Max Temperature: 34/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -137,7 +137,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (42)
|
||||
Temperature History Size (Index): 128 (28)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -156,6 +156,6 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 0 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 9159 Vendor specific
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 11669 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Mon Jul 5 07:56:56 2021 EDT
|
||||
Local Time is: Sun Aug 22 11:28:54 2021 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 163 159 021 - 4808
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2180
|
||||
3 Spin_Up_Time POS--K 164 159 021 - 4791
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2230
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 75974
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 76400
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2171
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 275
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2180
|
||||
194 Temperature_Celsius -O---K 110 102 000 - 37
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2221
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 276
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2230
|
||||
194 Temperature_Celsius -O---K 104 102 000 - 43
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -131,9 +131,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/37 Celsius
|
||||
Lifetime Min/Max Temperature: 20/45 Celsius
|
||||
Current Temperature: 43 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/44 Celsius
|
||||
Lifetime Min/Max Temperature: ?/45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (89)
|
||||
Temperature History Size (Index): 128 (72)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -158,6 +158,6 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 13864 Vendor specific
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 11729 Vendor specific
|
||||
|
||||
|
@@ -11,7 +11,7 @@ User Capacity: 500,106,780,160 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Sat May 15 09:32:28 2021 MDT
|
||||
Local Time is: Wed Aug 11 20:39:36 2021 MDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 128
|
||||
@@ -64,16 +64,16 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 175 168 021 - 6208
|
||||
4 Start_Stop_Count -O--CK 086 086 000 - 14825
|
||||
4 Start_Stop_Count -O--CK 086 086 000 - 14826
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 050 050 000 - 36551
|
||||
9 Power_On_Hours -O--CK 048 048 000 - 38668
|
||||
10 Spin_Retry_Count -O--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3724
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3725
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 112
|
||||
193 Load_Cycle_Count -O--CK 196 196 000 - 14826
|
||||
194 Temperature_Celsius -O---K 114 084 000 - 36
|
||||
193 Load_Cycle_Count -O--CK 196 196 000 - 14827
|
||||
194 Temperature_Celsius -O---K 113 084 000 - 37
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
@@ -126,8 +126,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: --/40 Celsius
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: --/41 Celsius
|
||||
Lifetime Min/Max Temperature: --/66 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -135,7 +135,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/85 Celsius
|
||||
Temperature History Size (Index): 128 (59)
|
||||
Temperature History Size (Index): 128 (8)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -154,6 +154,6 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 6010389 Vendor specific
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 3458057 Vendor specific
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Thu Mar 18 12:35:42 2021 UTC
|
||||
Local Time is: Thu Mar 18 16:25:33 2021 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -64,16 +64,16 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 136 134 021 - 4175
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4823
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4825
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 090 090 000 - 7950
|
||||
9 Power_On_Hours -O--CK 090 090 000 - 7953
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 4722
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 4724
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 381
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 4441
|
||||
194 Temperature_Celsius -O---K 103 098 000 - 40
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 4443
|
||||
194 Temperature_Celsius -O---K 104 098 000 - 39
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -278,9 +278,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 40 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/40 Celsius
|
||||
Lifetime Min/Max Temperature: 39/45 Celsius
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/39 Celsius
|
||||
Lifetime Min/Max Temperature: 31/45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -288,7 +288,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (69)
|
||||
Temperature History Size (Index): 478 (235)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -305,7 +305,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 5579 Vendor specific
|
||||
0x8000 4 1296 Vendor specific
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Tue Feb 16 16:10:39 2021 EET
|
||||
Local Time is: Tue Feb 16 16:12:05 2021 EET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -139,7 +139,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (271)
|
||||
Temperature History Size (Index): 478 (273)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -158,5 +158,5 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 35731230 Vendor specific
|
||||
0x8000 4 35731316 Vendor specific
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Tue Jul 6 20:51:13 2021 CDT
|
||||
Local Time is: Mon Jul 19 11:48:24 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -68,13 +68,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2804
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 063 063 000 - 27034
|
||||
9 Power_On_Hours -O--CK 063 063 000 - 27336
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1723
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 254
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2549
|
||||
194 Temperature_Celsius -O---K 106 092 000 - 37
|
||||
194 Temperature_Celsius -O---K 102 092 000 - 41
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -177,7 +177,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/42 Celsius
|
||||
Lifetime Min/Max Temperature: 24/51 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -187,7 +187,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (219)
|
||||
Temperature History Size (Index): 478 (163)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -206,7 +206,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 7859888 Vendor specific
|
||||
0x8000 4 8949441 Vendor specific
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Thu Feb 4 15:38:06 2021 CET
|
||||
Local Time is: Mon May 3 15:42:35 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -27,8 +27,8 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
@@ -63,21 +63,21 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 140 138 021 - 3991
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3979
|
||||
3 Spin_Up_Time POS--K 139 138 021 - 4008
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4004
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 062 062 000 - 27923
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 060 060 000 - 29910
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3779
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 949
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 3029
|
||||
194 Temperature_Celsius -O---K 100 081 000 - 43
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3804
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 966
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 3037
|
||||
194 Temperature_Celsius -O---K 109 081 000 - 34
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 1
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -278,9 +278,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 43 Celsius
|
||||
Power Cycle Min/Max Temperature: 41/43 Celsius
|
||||
Lifetime Min/Max Temperature: 42/61 Celsius
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/36 Celsius
|
||||
Lifetime Min/Max Temperature: 34/61 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -288,7 +288,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (303)
|
||||
Temperature History Size (Index): 478 (123)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -305,7 +305,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 2607 Vendor specific
|
||||
0x8000 4 1044301 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE amd64] (local build)
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Nov 11 20:26:43 2020 IST
|
||||
Local Time is: Wed Dec 9 12:19:34 2020 IST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,16 +63,16 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 138 136 021 - 4066
|
||||
4 Start_Stop_Count -O--CK 089 089 000 - 11733
|
||||
3 Spin_Up_Time POS--K 138 136 021 - 4100
|
||||
4 Start_Stop_Count -O--CK 089 089 000 - 11869
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 073 073 000 - 19713
|
||||
9 Power_On_Hours -O--CK 073 073 000 - 19912
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 089 089 000 - 11684
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1201
|
||||
193 Load_Cycle_Count -O--CK 197 197 000 - 10531
|
||||
12 Power_Cycle_Count -O--CK 089 089 000 - 11819
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1207
|
||||
193 Load_Cycle_Count -O--CK 197 197 000 - 10661
|
||||
194 Temperature_Celsius -O---K 105 091 000 - 38
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
@@ -131,7 +131,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/38 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/38 Celsius
|
||||
Lifetime Min/Max Temperature: 0/52 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -140,7 +140,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (428)
|
||||
Temperature History Size (Index): 478 (179)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -157,7 +157,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 1833 Vendor specific
|
||||
0x8000 4 17108 Vendor specific
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Nov 25 16:32:15 2021 WIB
|
||||
Local Time is: Thu Nov 25 17:20:26 2021 WIB
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -307,7 +307,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (40)
|
||||
Temperature History Size (Index): 478 (88)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -326,7 +326,5 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 15648 Vendor specific
|
||||
|
||||
|
||||
0x8000 4 18536 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE amd64] (local build)
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Nov 11 20:26:43 2020 IST
|
||||
Local Time is: Wed Dec 9 12:19:34 2020 IST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,16 +64,16 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 9
|
||||
3 Spin_Up_Time POS--K 143 141 021 - 3850
|
||||
4 Start_Stop_Count -O--CK 090 090 000 - 10843
|
||||
4 Start_Stop_Count -O--CK 090 090 000 - 10978
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 076 076 000 - 17559
|
||||
9 Power_On_Hours -O--CK 076 076 000 - 17821
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 090 090 000 - 10822
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1151
|
||||
193 Load_Cycle_Count -O--CK 197 197 000 - 9691
|
||||
194 Temperature_Celsius -O---K 105 091 000 - 38
|
||||
12 Power_Cycle_Count -O--CK 090 090 000 - 10957
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1157
|
||||
193 Load_Cycle_Count -O--CK 197 197 000 - 9820
|
||||
194 Temperature_Celsius -O---K 104 091 000 - 39
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -161,8 +161,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/38 Celsius
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/39 Celsius
|
||||
Lifetime Min/Max Temperature: 0/52 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -171,7 +171,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (134)
|
||||
Temperature History Size (Index): 478 (307)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -188,9 +188,9 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 1833 Vendor specific
|
||||
0x8000 4 17108 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p14-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p15-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Mar 28 16:56:25 2021 CDT
|
||||
Local Time is: Wed Mar 31 08:57:17 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 4
|
||||
3 Spin_Up_Time POS--K 142 141 021 - 3875
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 426
|
||||
3 Spin_Up_Time POS--K 141 140 021 - 3950
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 442
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 012 012 000 - 64264
|
||||
9 Power_On_Hours -O--CK 012 012 000 - 64327
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 424
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 207
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 218
|
||||
194 Temperature_Celsius -O---K 098 091 000 - 45
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 440
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 213
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 228
|
||||
194 Temperature_Celsius -O---K 094 091 000 - 49
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -229,8 +229,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: 40/45 Celsius
|
||||
Current Temperature: 49 Celsius
|
||||
Power Cycle Min/Max Temperature: 41/50 Celsius
|
||||
Lifetime Min/Max Temperature: 0/52 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -239,7 +239,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (167)
|
||||
Temperature History Size (Index): 478 (165)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -256,7 +256,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 20119 Vendor specific
|
||||
0x8000 4 58275 Vendor specific
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Dec 6 08:16:31 2022 UTC
|
||||
Local Time is: Sat Dec 10 22:56:17 2022 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -67,7 +67,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 089 089 000 - 11803
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 048 048 000 - 38581
|
||||
9 Power_On_Hours -O--CK 047 047 000 - 38691
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 4217
|
||||
@@ -291,7 +291,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (443)
|
||||
Temperature History Size (Index): 478 (384)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -308,7 +308,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 281463 Vendor specific
|
||||
0x8000 4 679454 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Apr 21 16:59:55 2022 CEST
|
||||
Local Time is: Thu Sep 1 15:38:10 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -28,8 +28,8 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 136 131 021 - 4183
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1323
|
||||
3 Spin_Up_Time POS--K 136 131 021 - 4191
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1327
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 078 078 000 - 16492
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 19680
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1312
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 232
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1095
|
||||
194 Temperature_Celsius -O---K 116 092 000 - 27
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1316
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 234
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1109
|
||||
194 Temperature_Celsius -O---K 113 092 000 - 30
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -130,8 +130,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/31 Celsius
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/40 Celsius
|
||||
Lifetime Min/Max Temperature: 0/51 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -140,7 +140,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (178)
|
||||
Temperature History Size (Index): 478 (323)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -157,9 +157,9 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 88 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 462 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 1823609 Vendor specific
|
||||
0x8000 4 9694342 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Nov 25 16:32:15 2021 WIB
|
||||
Local Time is: Thu Nov 25 17:20:26 2021 WIB
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,7 +68,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2029
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 6184
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 6185
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2010
|
||||
@@ -148,7 +148,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (135)
|
||||
Temperature History Size (Index): 478 (183)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -167,7 +167,7 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 15648 Vendor specific
|
||||
0x8000 4 18536 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jan 10 21:27:33 2023 UTC
|
||||
Local Time is: Tue Jan 10 23:26:25 2023 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,7 +68,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 056 056 000 - 44349
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 085 085 000 - 11304
|
||||
9 Power_On_Hours -O--CK 085 085 000 - 11306
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 056 056 000 - 44335
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (3)
|
||||
Temperature History Size (Index): 478 (122)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -160,5 +160,5 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 81300 Vendor specific
|
||||
0x8000 4 88425 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Jan 16 02:03:33 2023 CST
|
||||
Local Time is: Fri Jan 20 09:33:02 2023 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,13 +68,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 629
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 068 068 000 - 23788
|
||||
9 Power_On_Hours -O--CK 068 068 000 - 23892
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 508
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 32
|
||||
193 Load_Cycle_Count -O--CK 198 198 000 - 7377
|
||||
194 Temperature_Celsius -O---K 116 103 000 - 27
|
||||
194 Temperature_Celsius -O---K 113 103 000 - 30
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -131,7 +131,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 27 Celsius
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 17/38 Celsius
|
||||
Lifetime Min/Max Temperature: 0/40 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (259)
|
||||
Temperature History Size (Index): 478 (249)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -160,5 +160,5 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 1108423 Vendor specific
|
||||
0x8000 4 1480622 Vendor specific
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Blue
|
||||
@@ -11,10 +11,10 @@ User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Dec 22 20:41:50 2020 AEDT
|
||||
Local Time is: Sun May 1 21:43:16 2022 AEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,20 +64,20 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 141 140 021 - 3916
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 625
|
||||
3 Spin_Up_Time POS--K 141 140 021 - 3941
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 936
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 5377
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 6034
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 617
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 928
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 062 060 040 - 38 (Min/Max 27/39)
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 125
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 499
|
||||
190 Airflow_Temperature_Cel -O---K 074 060 040 - 26 (Min/Max 22/26)
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 406
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 529
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -134,8 +134,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/39 Celsius
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/26 Celsius
|
||||
Lifetime Min/Max Temperature: 0/40 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -144,7 +144,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (15)
|
||||
Temperature History Size (Index): 128 (114)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -163,9 +163,9 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 34589 Vendor specific
|
||||
0x8000 4 586 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Blue
|
||||
@@ -11,10 +11,10 @@ User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Dec 22 20:41:50 2020 AEDT
|
||||
Local Time is: Sun May 1 21:43:16 2022 AEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -29,8 +29,8 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
@@ -64,25 +64,25 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 144 143 021 - 3783
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 213
|
||||
3 Spin_Up_Time POS--K 143 142 021 - 3808
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 524
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 266
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 924
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 205
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 516
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 061 046 040 - 39 (Min/Max 27/40)
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 114
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 98
|
||||
190 Airflow_Temperature_Cel -O---K 073 046 040 - 27 (Min/Max 22/27)
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 395
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 128
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -139,8 +139,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/40 Celsius
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/27 Celsius
|
||||
Lifetime Min/Max Temperature: 0/57 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -149,7 +149,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (60)
|
||||
Temperature History Size (Index): 128 (35)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -168,9 +168,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 34590 Vendor specific
|
||||
|
||||
|
||||
0x8000 4 586 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Apr 21 16:59:55 2022 CEST
|
||||
Local Time is: Thu Sep 1 15:38:10 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,25 +64,25 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 2
|
||||
3 Spin_Up_Time POS--K 140 139 021 - 3991
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 847
|
||||
3 Spin_Up_Time POS--K 140 139 021 - 3966
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 851
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 081 081 000 - 14055
|
||||
9 Power_On_Hours -O--CK 077 077 000 - 17242
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 841
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 123
|
||||
193 Load_Cycle_Count -O--CK 195 195 000 - 15113
|
||||
194 Temperature_Celsius -O---K 117 092 000 - 26
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 845
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 125
|
||||
193 Load_Cycle_Count -O--CK 195 195 000 - 16071
|
||||
194 Temperature_Celsius -O---K 114 092 000 - 29
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
240 Head_Flying_Hours -O--CK 083 083 000 - 12787
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 40836100395
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 65522688490
|
||||
240 Head_Flying_Hours -O--CK 079 079 000 - 15794
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 63617168301
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 65876627153
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -189,8 +189,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/31 Celsius
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/39 Celsius
|
||||
Lifetime Min/Max Temperature: 0/52 Celsius
|
||||
Specified Max Operating Temperature: 25 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -200,7 +200,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (196)
|
||||
Temperature History Size (Index): 478 (341)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -217,7 +217,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 88 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 462 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 1823624 Vendor specific
|
||||
0x8000 4 9694445 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p21-HBSD amd64] (local build)
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jan 4 01:23:29 2022 AST
|
||||
Local Time is: Thu Feb 10 01:04:56 2022 PST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,25 +64,25 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 142 140 021 - 3866
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 68
|
||||
3 Spin_Up_Time POS--K 141 140 021 - 3908
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 87
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 1833
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2697
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 68
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 29
|
||||
193 Load_Cycle_Count -O--CK 182 182 000 - 55457
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 87
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 39
|
||||
193 Load_Cycle_Count -O--CK 176 176 000 - 74544
|
||||
194 Temperature_Celsius -O---K 116 104 000 - 27
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
240 Head_Flying_Hours -O--CK 099 099 000 - 1416
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 61463340935
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 3347034933
|
||||
240 Head_Flying_Hours -O--CK 098 098 000 - 2058
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 63570358798
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 3370795702
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -134,7 +134,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/30 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/30 Celsius
|
||||
Lifetime Min/Max Temperature: 0/39 Celsius
|
||||
Specified Max Operating Temperature: 27 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -144,7 +144,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (57)
|
||||
Temperature History Size (Index): 478 (177)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -161,7 +161,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 3492 Vendor specific
|
||||
0x8000 4 458458 Vendor specific
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Blue
|
||||
@@ -11,10 +11,10 @@ User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Jun 30 09:31:04 2021 CEST
|
||||
Local Time is: Fri Jan 13 11:45:35 2023 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,22 +64,22 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 180 171 021 - 1975
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 95
|
||||
3 Spin_Up_Time POS--K 173 171 021 - 2316
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 104
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 058 058 000 - 30935
|
||||
10 Spin_Retry_Count PO--CK 100 253 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 95
|
||||
9 Power_On_Hours -O--CK 041 041 000 - 43740
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 104
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 070 063 040 - 30 (Min/Max 24/30)
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 59
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 81
|
||||
194 Temperature_Celsius -O---K 113 106 000 - 30
|
||||
190 Airflow_Temperature_Cel -O---K 064 059 040 - 36 (Min/Max 29/37)
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 63
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 88
|
||||
194 Temperature_Celsius -O---K 107 102 000 - 36
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -111,7 +111,7 @@ Address Access R/W Size Description
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
|
||||
0xb6 GPL VS 4017 Device vendor specific log
|
||||
0xb6 GPL VS 5617 Device vendor specific log
|
||||
0xb6 SL VS 1 Device vendor specific log
|
||||
0xb7 GPL,SL VS 48 Device vendor specific log
|
||||
0xbd GPL,SL VS 1 Device vendor specific log
|
||||
@@ -121,7 +121,7 @@ Address Access R/W Size Description
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
Device Error Count: 121 (device log contains only the most recent 24 errors)
|
||||
Device Error Count: 155 (device log contains only the most recent 24 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
@@ -137,7 +137,7 @@ Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 121 [0] occurred at disk power-on lifetime: 30934 hours (1288 days + 22 hours)
|
||||
Error 155 [10] occurred at disk power-on lifetime: 43663 hours (1819 days + 7 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
@@ -148,13 +148,13 @@ Error 121 [0] occurred at disk power-on lifetime: 30934 hours (1288 days + 22 ho
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:00:05.220 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:05.219 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 00:00:04.911 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 00:00:04.911 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 00:00:04.911 READ DMA EXT
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 40d+15:05:24.557 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 40d+15:05:24.557 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 40d+15:05:24.247 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 40d+15:05:24.247 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 40d+15:05:24.247 READ DMA EXT
|
||||
|
||||
Error 120 [23] occurred at disk power-on lifetime: 30934 hours (1288 days + 22 hours)
|
||||
Error 154 [9] occurred at disk power-on lifetime: 43441 hours (1810 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
@@ -165,13 +165,13 @@ Error 120 [23] occurred at disk power-on lifetime: 30934 hours (1288 days + 22 h
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 02:35:34.978 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 02:35:34.978 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 02:35:34.670 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 02:35:34.670 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 02:35:34.670 READ DMA EXT
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 31d+09:53:59.940 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 31d+09:53:59.940 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 31d+09:53:59.628 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 31d+09:53:59.628 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 31d+09:53:59.628 READ DMA EXT
|
||||
|
||||
Error 119 [22] occurred at disk power-on lifetime: 30933 hours (1288 days + 21 hours)
|
||||
Error 153 [8] occurred at disk power-on lifetime: 42985 hours (1791 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
@@ -182,13 +182,13 @@ Error 119 [22] occurred at disk power-on lifetime: 30933 hours (1288 days + 21 h
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 01:23:07.001 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 01:23:07.001 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 01:23:02.635 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 01:23:02.635 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 01:23:02.635 READ DMA EXT
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 12d+09:04:18.686 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 12d+09:04:18.686 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 12d+09:04:18.373 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 12d+09:04:18.373 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 12d+09:04:18.373 READ DMA EXT
|
||||
|
||||
Error 118 [21] occurred at disk power-on lifetime: 30932 hours (1288 days + 20 hours)
|
||||
Error 152 [7] occurred at disk power-on lifetime: 42687 hours (1778 days + 15 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
@@ -199,13 +199,13 @@ Error 118 [21] occurred at disk power-on lifetime: 30932 hours (1288 days + 20 h
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:54:31.968 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:54:31.968 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 00:54:25.192 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 00:54:25.192 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 00:54:25.191 READ DMA EXT
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:00:05.369 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:05.369 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 00:00:05.061 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 00:00:05.061 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 00:00:05.061 READ DMA EXT
|
||||
|
||||
Error 117 [20] occurred at disk power-on lifetime: 30931 hours (1288 days + 19 hours)
|
||||
Error 151 [6] occurred at disk power-on lifetime: 42683 hours (1778 days + 11 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
@@ -216,62 +216,62 @@ Error 117 [20] occurred at disk power-on lifetime: 30931 hours (1288 days + 19 h
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:00:41.045 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:41.045 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 00:00:12.273 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 00:00:12.273 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 00:00:12.273 READ DMA EXT
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:00:05.320 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:05.320 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 00:00:05.012 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 00:00:05.011 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 00:00:05.011 READ DMA EXT
|
||||
|
||||
Error 116 [19] occurred at disk power-on lifetime: 30931 hours (1288 days + 19 hours)
|
||||
Error 150 [5] occurred at disk power-on lifetime: 42323 hours (1763 days + 11 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 53 00 00 00 00 00 00 00 02 e0 00
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 04:39:27.008 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 04:39:27.008 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 04:39:26.698 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 04:39:26.698 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 04:39:26.698 READ DMA EXT
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 2d+13:54:47.937 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 2d+13:54:47.937 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 2d+13:54:47.626 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 2d+13:54:47.625 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 2d+13:54:47.625 READ DMA EXT
|
||||
|
||||
Error 115 [18] occurred at disk power-on lifetime: 30931 hours (1288 days + 19 hours)
|
||||
Error 149 [4] occurred at disk power-on lifetime: 39875 hours (1661 days + 11 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 53 00 00 00 00 00 00 00 02 e0 00
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 04:10:40.568 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 04:10:40.568 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 04:10:37.258 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 04:10:37.257 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 04:10:37.257 READ DMA EXT
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:32:26.378 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:32:26.377 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 00:32:26.066 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 00:32:26.066 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 00:32:26.066 READ DMA EXT
|
||||
|
||||
Error 114 [17] occurred at disk power-on lifetime: 30931 hours (1288 days + 19 hours)
|
||||
Error 148 [3] occurred at disk power-on lifetime: 39875 hours (1661 days + 11 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 53 00 00 00 00 00 00 00 02 e0 00
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 03:56:08.276 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 03:56:08.276 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 03:56:02.878 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 03:56:02.877 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 03:56:02.877 READ DMA EXT
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:24:30.973 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:24:30.973 SECURITY FREEZE LOCK
|
||||
25 00 00 00 20 00 00 3a 38 60 0f e0 00 00:24:30.665 READ DMA EXT
|
||||
25 00 00 00 20 00 00 00 00 00 02 e0 00 00:24:30.665 READ DMA EXT
|
||||
25 00 00 00 01 00 00 3a 38 60 2e e0 00 00:24:30.665 READ DMA EXT
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
@@ -291,9 +291,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/30 Celsius
|
||||
Lifetime Min/Max Temperature: 19/37 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/37 Celsius
|
||||
Lifetime Min/Max Temperature: 19/41 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -304,7 +304,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (101)
|
||||
Temperature History Size (Index): 128 (47)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -313,42 +313,42 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 95 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 30935 --- Power-on Hours
|
||||
0x01 0x018 6 20982624577 --- Logical Sectors Written
|
||||
0x01 0x020 6 546566744 --- Number of Write Commands
|
||||
0x01 0x028 6 772563130 --- Logical Sectors Read
|
||||
0x01 0x030 6 12651922 --- Number of Read Commands
|
||||
0x01 0x038 6 3991817600 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 104 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 43740 --- Power-on Hours
|
||||
0x01 0x018 6 59146331853 --- Logical Sectors Written
|
||||
0x01 0x020 6 942149523 --- Number of Write Commands
|
||||
0x01 0x028 6 3000902052 --- Logical Sectors Read
|
||||
0x01 0x030 6 45169358 --- Number of Read Commands
|
||||
0x01 0x038 6 2845177344 --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 30914 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 30902 --- Head Flying Hours
|
||||
0x03 0x018 4 141 --- Head Load Events
|
||||
0x03 0x008 4 43110 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 43097 --- Head Flying Hours
|
||||
0x03 0x018 4 152 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 75 --- Read Recovery Attempts
|
||||
0x03 0x028 4 498 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 59 --- Number of High Priority Unload Events
|
||||
0x03 0x040 4 63 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x010 1 30 --- Average Short Term Temperature
|
||||
0x05 0x018 1 26 --- Average Long Term Temperature
|
||||
0x05 0x020 1 37 --- Highest Temperature
|
||||
0x05 0x008 1 36 --- Current Temperature
|
||||
0x05 0x010 1 36 --- Average Short Term Temperature
|
||||
0x05 0x018 1 35 --- Average Long Term Temperature
|
||||
0x05 0x020 1 41 --- Highest Temperature
|
||||
0x05 0x028 1 19 --- Lowest Temperature
|
||||
0x05 0x030 1 36 --- Highest Average Short Term Temperature
|
||||
0x05 0x030 1 40 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 25 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 34 --- Highest Average Long Term Temperature
|
||||
0x05 0x040 1 37 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 26 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 429 --- Number of Hardware Resets
|
||||
0x06 0x010 4 280 --- Number of ASR Events
|
||||
0x06 0x008 4 566 --- Number of Hardware Resets
|
||||
0x06 0x010 4 377 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
@@ -366,11 +366,11 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 15 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 16 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 2269 Vendor specific
|
||||
0x8000 4 3789482 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p21-HBSD amd64] (local build)
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jan 25 18:53:12 2022 UTC
|
||||
Local Time is: Wed Feb 9 14:02:30 2022 IST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,22 +63,22 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 180 173 021 - 1966
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 91
|
||||
3 Spin_Up_Time POS--K 177 173 021 - 2150
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 92
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 080 080 000 - 14626
|
||||
9 Power_On_Hours -O--CK 080 080 000 - 14645
|
||||
10 Spin_Retry_Count PO--CK 100 253 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 91
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 92
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 069 055 040 - 31 (Min/Max 31/32)
|
||||
190 Airflow_Temperature_Cel -O---K 062 055 040 - 38 (Min/Max 23/38)
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 31
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 75
|
||||
194 Temperature_Celsius -O---K 112 098 000 - 31
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 96
|
||||
194 Temperature_Celsius -O---K 106 098 000 - 37
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -110,7 +110,7 @@ Address Access R/W Size Description
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
|
||||
0xb6 GPL VS 1829 Device vendor specific log
|
||||
0xb6 GPL VS 1832 Device vendor specific log
|
||||
0xb6 SL VS 1 Device vendor specific log
|
||||
0xb7 GPL,SL VS 48 Device vendor specific log
|
||||
0xbd GPL,SL VS 1 Device vendor specific log
|
||||
@@ -120,7 +120,7 @@ Address Access R/W Size Description
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
Device Error Count: 127 (device log contains only the most recent 24 errors)
|
||||
Device Error Count: 132 (device log contains only the most recent 24 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
@@ -136,6 +136,91 @@ Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 132 [11] occurred at disk power-on lifetime: 14643 hours (610 days + 3 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:33:36.003 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:33:36.003 SECURITY FREEZE LOCK
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 00:33:35.695 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 00:33:35.695 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 1f e0 00 00:33:35.695 READ DMA EXT
|
||||
|
||||
Error 131 [10] occurred at disk power-on lifetime: 14643 hours (610 days + 3 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:32:13.253 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:32:13.253 SECURITY FREEZE LOCK
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 00:32:12.946 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 00:32:12.946 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 1f e0 00 00:32:12.946 READ DMA EXT
|
||||
|
||||
Error 130 [9] occurred at disk power-on lifetime: 14643 hours (610 days + 3 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:31:26.826 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:31:26.826 SECURITY FREEZE LOCK
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 00:31:26.518 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 00:31:26.517 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 1f e0 00 00:31:26.517 READ DMA EXT
|
||||
|
||||
Error 129 [8] occurred at disk power-on lifetime: 14643 hours (610 days + 3 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:28:02.857 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:28:02.857 SECURITY FREEZE LOCK
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 00:28:02.548 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 00:28:02.548 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 1f e0 00 00:28:02.548 READ DMA EXT
|
||||
|
||||
Error 128 [7] occurred at disk power-on lifetime: 14642 hours (610 days + 2 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:00:02.729 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:02.728 SECURITY FREEZE LOCK
|
||||
ec 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:02.667 IDENTIFY DEVICE
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 00:00:02.374 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 00:00:02.374 READ DMA EXT
|
||||
|
||||
Error 127 [6] occurred at disk power-on lifetime: 14622 hours (609 days + 6 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
@@ -187,91 +272,6 @@ Error 125 [4] occurred at disk power-on lifetime: 14620 hours (609 days + 4 hour
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 00:04:02.458 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 1f e0 00 00:04:02.458 READ DMA EXT
|
||||
|
||||
Error 124 [3] occurred at disk power-on lifetime: 14620 hours (609 days + 4 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:00:03.922 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:03.922 SECURITY FREEZE LOCK
|
||||
ec 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:03.860 IDENTIFY DEVICE
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 00:00:03.564 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 00:00:03.564 READ DMA EXT
|
||||
|
||||
Error 123 [2] occurred at disk power-on lifetime: 14619 hours (609 days + 3 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:15:27.320 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:15:27.320 SECURITY FREEZE LOCK
|
||||
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:15:27.040 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:15:26.301 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:15:26.283 READ DMA EXT
|
||||
|
||||
Error 122 [1] occurred at disk power-on lifetime: 14619 hours (609 days + 3 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:00:02.662 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:02.662 SECURITY FREEZE LOCK
|
||||
ec 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:02.616 IDENTIFY DEVICE
|
||||
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:00:02.372 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:00:01.632 READ DMA EXT
|
||||
|
||||
Error 121 [0] occurred at disk power-on lifetime: 14617 hours (609 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:00:03.400 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:03.399 SECURITY FREEZE LOCK
|
||||
ec 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:03.354 IDENTIFY DEVICE
|
||||
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:00:03.101 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:00:02.369 READ DMA EXT
|
||||
|
||||
Error 120 [23] occurred at disk power-on lifetime: 14617 hours (609 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:13:20.929 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:13:20.929 SECURITY FREEZE LOCK
|
||||
ec 00 00 00 00 00 00 00 00 00 00 e0 00 00:13:10.537 IDENTIFY DEVICE
|
||||
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:13:10.273 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:13:09.268 READ DMA EXT
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Aborted by host 90% 14617 -
|
||||
@@ -291,8 +291,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/33 Celsius
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/38 Celsius
|
||||
Lifetime Min/Max Temperature: 20/45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -304,7 +304,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (83)
|
||||
Temperature History Size (Index): 128 (33)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -313,17 +313,17 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 91 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 14626 --- Power-on Hours
|
||||
0x01 0x018 6 21752763592 --- Logical Sectors Written
|
||||
0x01 0x008 4 92 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 14645 --- Power-on Hours
|
||||
0x01 0x018 6 21752763596 --- Logical Sectors Written
|
||||
0x01 0x020 6 601074140 --- Number of Write Commands
|
||||
0x01 0x028 6 41879940087 --- Logical Sectors Read
|
||||
0x01 0x030 6 394130856 --- Number of Read Commands
|
||||
0x01 0x038 6 1113992448 --- Date and Time TimeStamp
|
||||
0x01 0x028 6 41879941519 --- Logical Sectors Read
|
||||
0x01 0x030 6 394131490 --- Number of Read Commands
|
||||
0x01 0x038 6 1182392448 --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 13888 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 13879 --- Head Flying Hours
|
||||
0x03 0x018 4 107 --- Head Load Events
|
||||
0x03 0x008 4 13907 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 13881 --- Head Flying Hours
|
||||
0x03 0x018 4 128 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
@@ -333,13 +333,13 @@ Page Offset Size Value Flags Description
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 31 --- Current Temperature
|
||||
0x05 0x010 1 36 --- Average Short Term Temperature
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x010 1 32 --- Average Short Term Temperature
|
||||
0x05 0x018 1 36 --- Average Long Term Temperature
|
||||
0x05 0x020 1 45 --- Highest Temperature
|
||||
0x05 0x028 1 25 --- Lowest Temperature
|
||||
0x05 0x030 1 42 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 32 --- Lowest Average Short Term Temperature
|
||||
0x05 0x038 1 31 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 38 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 34 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
@@ -347,8 +347,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 328 --- Number of Hardware Resets
|
||||
0x06 0x010 4 209 --- Number of ASR Events
|
||||
0x06 0x008 4 347 --- Number of Hardware Resets
|
||||
0x06 0x010 4 222 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
@@ -366,13 +366,13 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 18 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 16482 Vendor specific
|
||||
0x8000 4 7858 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 3.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Oct 8 13:02:52 2022 EDT
|
||||
Local Time is: Sat Oct 8 13:38:37 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -76,10 +76,10 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 065 043 040 - 35 (Min/Max 35/36)
|
||||
190 Airflow_Temperature_Cel -O---K 062 043 040 - 38 (Min/Max 35/38)
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 221
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 252
|
||||
194 Temperature_Celsius -O---K 108 086 000 - 35
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 254
|
||||
194 Temperature_Celsius -O---K 105 086 000 - 38
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -143,8 +143,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/36 Celsius
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/39 Celsius
|
||||
Lifetime Min/Max Temperature: 17/57 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -156,7 +156,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (64)
|
||||
Temperature History Size (Index): 128 (98)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -167,15 +167,15 @@ Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 351 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 9017 --- Power-on Hours
|
||||
0x01 0x018 6 76425414489 --- Logical Sectors Written
|
||||
0x01 0x020 6 954569823 --- Number of Write Commands
|
||||
0x01 0x028 6 72075945716 --- Logical Sectors Read
|
||||
0x01 0x030 6 856848970 --- Number of Read Commands
|
||||
0x01 0x018 6 76425414500 --- Logical Sectors Written
|
||||
0x01 0x020 6 954569826 --- Number of Write Commands
|
||||
0x01 0x028 6 72075956721 --- Logical Sectors Read
|
||||
0x01 0x030 6 856849357 --- Number of Read Commands
|
||||
0x01 0x038 6 2396428928 --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 8711 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 8657 --- Head Flying Hours
|
||||
0x03 0x018 4 474 --- Head Load Events
|
||||
0x03 0x018 4 476 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 3 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
@@ -185,7 +185,7 @@ Page Offset Size Value Flags Description
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 35 --- Current Temperature
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x010 1 37 --- Average Short Term Temperature
|
||||
0x05 0x018 1 35 --- Average Long Term Temperature
|
||||
0x05 0x020 1 57 --- Highest Temperature
|
||||
@@ -199,8 +199,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 5528 --- Number of Hardware Resets
|
||||
0x06 0x010 4 2140 --- Number of ASR Events
|
||||
0x06 0x008 4 5540 --- Number of Hardware Resets
|
||||
0x06 0x010 4 2144 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
@@ -218,11 +218,11 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 10 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 17 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 173 Vendor specific
|
||||
0x8000 4 2316 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Jan 25 13:20:56 2022 MSK
|
||||
Local Time is: Tue Jan 25 13:29:50 2022 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -291,7 +291,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (253)
|
||||
Temperature History Size (Index): 478 (262)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -314,7 +314,7 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 23836531 Vendor specific
|
||||
0x8000 4 23837064 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Tue Feb 8 10:37:33 2022 CET
|
||||
Local Time is: Tue Feb 8 10:58:00 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -73,8 +73,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 091 091 000 - 9251
|
||||
192 Power-Off_Retract_Count -O--CK 189 189 000 - 8728
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1819873
|
||||
194 Temperature_Celsius -O---K 113 098 000 - 34
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1819875
|
||||
194 Temperature_Celsius -O---K 106 098 000 - 41
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -127,8 +127,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/33 Celsius
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/41 Celsius
|
||||
Lifetime Min/Max Temperature: 11/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -140,7 +140,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (41)
|
||||
Temperature History Size (Index): 128 (62)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -159,5 +159,5 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 428 Vendor specific
|
||||
0x8000 4 1653 Vendor specific
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.3-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Scorpio Black (AF)
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Fri Dec 25 14:16:14 2020 AEDT
|
||||
Local Time is: Thu Dec 30 16:25:41 2021 AEDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 187 163 021 - 1650
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2080
|
||||
3 Spin_Up_Time POS--K 188 163 021 - 1558
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2102
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 046 046 000 - 39757
|
||||
9 Power_On_Hours -O--CK 034 034 000 - 48605
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 146
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 7
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 689438
|
||||
194 Temperature_Celsius -O---K 115 100 000 - 32
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 168
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 25
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1545185
|
||||
194 Temperature_Celsius -O---K 118 100 000 - 29
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -113,24 +113,24 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 29020 -
|
||||
# 2 Extended offline Completed without error 00% 28996 -
|
||||
# 3 Extended offline Completed without error 00% 28972 -
|
||||
# 4 Extended offline Completed without error 00% 28948 -
|
||||
# 5 Extended offline Completed without error 00% 28924 -
|
||||
# 6 Extended offline Completed without error 00% 28900 -
|
||||
# 7 Extended offline Completed without error 00% 28876 -
|
||||
# 8 Extended offline Completed without error 00% 28852 -
|
||||
# 9 Extended offline Completed without error 00% 28828 -
|
||||
#10 Extended offline Completed without error 00% 28814 -
|
||||
#11 Extended offline Completed without error 00% 28790 -
|
||||
#12 Extended offline Completed without error 00% 28766 -
|
||||
#13 Extended offline Completed without error 00% 28742 -
|
||||
#14 Extended offline Completed without error 00% 28718 -
|
||||
#15 Extended offline Completed without error 00% 28694 -
|
||||
#16 Extended offline Completed without error 00% 28670 -
|
||||
#17 Extended offline Completed without error 00% 28646 -
|
||||
#18 Extended offline Completed without error 00% 28622 -
|
||||
# 1 Extended offline Completed without error 00% 48578 -
|
||||
# 2 Extended offline Completed without error 00% 48576 -
|
||||
# 3 Extended offline Aborted by host 90% 48565 -
|
||||
# 4 Extended offline Completed without error 00% 29020 -
|
||||
# 5 Extended offline Completed without error 00% 28996 -
|
||||
# 6 Extended offline Completed without error 00% 28972 -
|
||||
# 7 Extended offline Completed without error 00% 28948 -
|
||||
# 8 Extended offline Completed without error 00% 28924 -
|
||||
# 9 Extended offline Completed without error 00% 28900 -
|
||||
#10 Extended offline Completed without error 00% 28876 -
|
||||
#11 Extended offline Completed without error 00% 28852 -
|
||||
#12 Extended offline Completed without error 00% 28828 -
|
||||
#13 Extended offline Completed without error 00% 28814 -
|
||||
#14 Extended offline Completed without error 00% 28790 -
|
||||
#15 Extended offline Completed without error 00% 28766 -
|
||||
#16 Extended offline Completed without error 00% 28742 -
|
||||
#17 Extended offline Completed without error 00% 28718 -
|
||||
#18 Extended offline Completed without error 00% 28694 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -146,9 +146,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 18/36 Celsius
|
||||
Lifetime Min/Max Temperature: 0/47 Celsius
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/35 Celsius
|
||||
Lifetime Min/Max Temperature: 27/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -159,7 +159,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (86)
|
||||
Temperature History Size (Index): 128 (17)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -176,9 +176,9 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 16843748 Vendor specific
|
||||
0x8000 4 164385 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.3-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Scorpio Black (AF)
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Fri Dec 25 14:16:14 2020 AEDT
|
||||
Local Time is: Thu Dec 30 16:25:41 2021 AEDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 184 162 021 - 1800
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2122
|
||||
3 Spin_Up_Time POS--K 189 162 021 - 1550
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2149
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 046 046 000 - 39653
|
||||
9 Power_On_Hours -O--CK 034 034 000 - 48221
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 149
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 14
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 668053
|
||||
194 Temperature_Celsius -O---K 115 100 000 - 32
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 176
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 37
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1456494
|
||||
194 Temperature_Celsius -O---K 118 100 000 - 29
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -113,24 +113,24 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 28983 -
|
||||
# 2 Extended offline Completed without error 00% 28959 -
|
||||
# 3 Extended offline Completed without error 00% 28935 -
|
||||
# 4 Extended offline Completed without error 00% 28911 -
|
||||
# 5 Extended offline Completed without error 00% 28887 -
|
||||
# 6 Extended offline Completed without error 00% 28863 -
|
||||
# 7 Extended offline Completed without error 00% 28839 -
|
||||
# 8 Extended offline Completed without error 00% 28815 -
|
||||
# 9 Extended offline Completed without error 00% 28791 -
|
||||
#10 Extended offline Completed without error 00% 28778 -
|
||||
#11 Extended offline Completed without error 00% 28754 -
|
||||
#12 Extended offline Completed without error 00% 28730 -
|
||||
#13 Extended offline Completed without error 00% 28706 -
|
||||
#14 Extended offline Completed without error 00% 28682 -
|
||||
#15 Extended offline Completed without error 00% 28658 -
|
||||
#16 Extended offline Completed without error 00% 28634 -
|
||||
#17 Extended offline Completed without error 00% 28610 -
|
||||
#18 Extended offline Completed without error 00% 28586 -
|
||||
# 1 Extended offline Completed without error 00% 48198 -
|
||||
# 2 Extended offline Interrupted (host reset) 90% 48191 -
|
||||
# 3 Extended offline Aborted by host 90% 48182 -
|
||||
# 4 Extended offline Completed without error 00% 28983 -
|
||||
# 5 Extended offline Completed without error 00% 28959 -
|
||||
# 6 Extended offline Completed without error 00% 28935 -
|
||||
# 7 Extended offline Completed without error 00% 28911 -
|
||||
# 8 Extended offline Completed without error 00% 28887 -
|
||||
# 9 Extended offline Completed without error 00% 28863 -
|
||||
#10 Extended offline Completed without error 00% 28839 -
|
||||
#11 Extended offline Completed without error 00% 28815 -
|
||||
#12 Extended offline Completed without error 00% 28791 -
|
||||
#13 Extended offline Completed without error 00% 28778 -
|
||||
#14 Extended offline Completed without error 00% 28754 -
|
||||
#15 Extended offline Completed without error 00% 28730 -
|
||||
#16 Extended offline Completed without error 00% 28706 -
|
||||
#17 Extended offline Completed without error 00% 28682 -
|
||||
#18 Extended offline Completed without error 00% 28658 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -146,9 +146,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 17/36 Celsius
|
||||
Lifetime Min/Max Temperature: 0/47 Celsius
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/35 Celsius
|
||||
Lifetime Min/Max Temperature: 28/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -159,7 +159,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (116)
|
||||
Temperature History Size (Index): 128 (85)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -170,15 +170,15 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 1 R_ERR response for data FIS
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 1 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 2 R_ERR response for non-data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 2 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 11 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 2 CRC errors within host-to-device FIS
|
||||
0x8000 4 16843434 Vendor specific
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 164382 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 13.0-CURRENT amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat May 9 06:15:41 2020 CET
|
||||
Local Time is: Sat May 9 06:24:52 2020 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,16 +64,16 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 177 174 021 - 2150
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3188
|
||||
3 Spin_Up_Time POS--K 176 174 021 - 2175
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3190
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 086 086 000 - 10313
|
||||
9 Power_On_Hours -O--CK 086 086 000 - 10314
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2605
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2607
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 131
|
||||
193 Load_Cycle_Count -O--CK 180 180 000 - 62464
|
||||
193 Load_Cycle_Count -O--CK 180 180 000 - 62472
|
||||
194 Temperature_Celsius -O---K 115 096 000 - 32
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
@@ -143,8 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (65535)
|
||||
Invalid Temperature History Size or Index
|
||||
Temperature History Size (Index): 128 (8)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -167,7 +166,7 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 414 Vendor specific
|
||||
0x8000 4 415 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Nov 3 18:27:26 2020 CET
|
||||
Local Time is: Tue Nov 3 18:39:23 2020 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -73,8 +73,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1110
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 65
|
||||
193 Load_Cycle_Count -O--CK 185 185 000 - 46552
|
||||
194 Temperature_Celsius -O---K 126 099 000 - 21
|
||||
193 Load_Cycle_Count -O--CK 185 185 000 - 46556
|
||||
194 Temperature_Celsius -O---K 121 099 000 - 26
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -132,8 +132,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 21 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/21 Celsius
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/26 Celsius
|
||||
Lifetime Min/Max Temperature: 14/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -145,7 +145,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (74)
|
||||
Temperature History Size (Index): 128 (85)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -163,12 +163,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 249 Vendor specific
|
||||
0x8000 4 964 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 10000 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Feb 24 11:44:08 2021 CET
|
||||
Local Time is: Wed Mar 3 17:05:44 2021 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,25 +66,25 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 177 176 021 - 2141
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 396
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 402
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 9141
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 9314
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 395
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 401
|
||||
191 G-Sense_Error_Rate -O--CK 083 083 000 - 17
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 153
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 242
|
||||
194 Temperature_Celsius -O---K 110 103 000 - 37
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 155
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 246
|
||||
194 Temperature_Celsius -O---K 108 103 000 - 39
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
240 Head_Flying_Hours -O--CK 089 089 000 - 8587
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 51989945529
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 7445669385
|
||||
240 Head_Flying_Hours -O--CK 089 089 000 - 8754
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 52168514315
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 7464419999
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -136,8 +136,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/41 Celsius
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/40 Celsius
|
||||
Lifetime Min/Max Temperature: 14/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -149,7 +149,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (132)
|
||||
Temperature History Size (Index): 478 (467)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -169,12 +169,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 16 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 17 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 1 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 159893 Vendor specific
|
||||
0x8000 4 520199 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Oct 13 21:00:51 2021 CST
|
||||
Local Time is: Thu Oct 21 05:29:14 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -29,9 +29,9 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
@@ -65,17 +65,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 153 148 021 - 1333
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 126
|
||||
3 Spin_Up_Time POS--K 152 148 021 - 1391
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 147
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 455
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 568
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 123
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 33
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 4540
|
||||
194 Temperature_Celsius -O---K 102 095 000 - 41
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 144
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 41
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 5352
|
||||
194 Temperature_Celsius -O---K 111 095 000 - 32
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -131,9 +131,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/42 Celsius
|
||||
Lifetime Min/Max Temperature: 27/48 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/34 Celsius
|
||||
Lifetime Min/Max Temperature: 26/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -144,7 +144,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (53)
|
||||
Temperature History Size (Index): 128 (34)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -162,12 +162,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 11 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 6309 Vendor specific
|
||||
0x8000 4 874 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 14.0-CURRENT amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Blue Mobile
|
||||
@@ -11,10 +11,10 @@ User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Jan 29 01:27:56 2022 EST
|
||||
Local Time is: Sat Sep 10 11:19:29 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,24 +63,24 @@ SCT capabilities: (0x303d) SCT Status supported.
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 188 051 - 2
|
||||
3 Spin_Up_Time POS--K 153 144 021 - 1325
|
||||
4 Start_Stop_Count -O--CK 069 069 000 - 31993
|
||||
1 Raw_Read_Error_Rate POSR-K 200 188 051 - 0
|
||||
3 Spin_Up_Time POS--K 148 144 021 - 1583
|
||||
4 Start_Stop_Count -O--CK 067 067 000 - 33848
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 090 090 000 - 7392
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 9148
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3775
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 4235
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 001 000 - 882
|
||||
188 Command_Timeout -O--CK 100 001 000 - 4295492134
|
||||
190 Airflow_Temperature_Cel -O---K 065 053 040 - 35 (Min/Max 34/35)
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 666
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 109
|
||||
193 Load_Cycle_Count -O--CK 188 188 000 - 38285
|
||||
194 Temperature_Celsius -O---K 108 096 000 - 35
|
||||
190 Airflow_Temperature_Cel -O---K 076 053 040 - 24 (Min/Max 22/24)
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 667
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 142
|
||||
193 Load_Cycle_Count -O--CK 183 183 000 - 51403
|
||||
194 Temperature_Celsius -O---K 119 096 000 - 24
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -289,9 +289,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 34/35 Celsius
|
||||
Lifetime Min/Max Temperature: 13/48 Celsius
|
||||
Current Temperature: 24 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/24 Celsius
|
||||
Lifetime Min/Max Temperature: 9/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -302,7 +302,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (31)
|
||||
Temperature History Size (Index): 128 (87)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -322,10 +322,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 681 Vendor specific
|
||||
0x8000 4 615 Vendor specific
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.4-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Black Mobile
|
||||
@@ -10,10 +10,10 @@ Firmware Version: 01.01A01
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jun 16 14:55:16 2020 +05
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Jul 8 07:29:29 2022 +05
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 141 140 021 - 1908
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2848
|
||||
3 Spin_Up_Time POS--K 142 140 021 - 1891
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3334
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 199 000 - 0
|
||||
9 Power_On_Hours -O--CK 077 077 000 - 17040
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 073 073 000 - 20167
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2848
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 951
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 3326
|
||||
194 Temperature_Celsius -O---K 100 088 000 - 43
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3334
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1033
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 3745
|
||||
194 Temperature_Celsius -O---K 110 088 000 - 33
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -228,8 +228,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 43 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/43 Celsius
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/33 Celsius
|
||||
Lifetime Min/Max Temperature: 21/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -241,7 +241,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (94)
|
||||
Temperature History Size (Index): 128 (66)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -259,10 +259,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 34 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 34 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 37415 Vendor specific
|
||||
0x8000 4 403 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.8] (local build)
|
||||
smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.9] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Oct 20 15:05:53 2020 EDT
|
||||
Local Time is: Mon May 17 13:27:14 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -60,16 +60,16 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
|
||||
3 Spin_Up_Time 0x0027 144 143 021 Pre-fail Always - 1766
|
||||
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 304
|
||||
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 333
|
||||
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
|
||||
7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
|
||||
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 597
|
||||
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 678
|
||||
10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
|
||||
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
|
||||
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 304
|
||||
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 333
|
||||
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 5
|
||||
193 Load_Cycle_Count 0x0032 196 196 000 Old_age Always - 12180
|
||||
194 Temperature_Celsius 0x0022 104 095 000 Old_age Always - 39
|
||||
193 Load_Cycle_Count 0x0032 196 196 000 Old_age Always - 13303
|
||||
194 Temperature_Celsius 0x0022 103 095 000 Old_age Always - 40
|
||||
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
|
||||
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
|
||||
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
|
||||
@@ -81,27 +81,27 @@ No Errors Logged
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Interrupted (host reset) 90% 596 -
|
||||
# 2 Extended offline Interrupted (host reset) 10% 582 -
|
||||
# 3 Short offline Completed without error 00% 542 -
|
||||
# 4 Extended offline Interrupted (host reset) 10% 532 -
|
||||
# 5 Short offline Completed without error 00% 524 -
|
||||
# 6 Short offline Completed without error 00% 513 -
|
||||
# 7 Short offline Aborted by host 10% 510 -
|
||||
# 8 Extended offline Interrupted (host reset) 80% 508 -
|
||||
# 9 Extended offline Interrupted (host reset) 90% 489 -
|
||||
#10 Extended offline Interrupted (host reset) 70% 485 -
|
||||
#11 Short offline Completed without error 00% 481 -
|
||||
#12 Short offline Completed without error 00% 473 -
|
||||
#13 Short offline Completed without error 00% 471 -
|
||||
#14 Short offline Completed without error 00% 467 -
|
||||
#15 Extended offline Interrupted (host reset) 60% 464 -
|
||||
#16 Short offline Aborted by host 70% 460 -
|
||||
#17 Extended offline Interrupted (host reset) 80% 453 -
|
||||
#18 Short offline Completed without error 00% 443 -
|
||||
#19 Extended offline Interrupted (host reset) 70% 379 -
|
||||
#20 Extended offline Interrupted (host reset) 30% 369 -
|
||||
#21 Short offline Aborted by host 10% 366 -
|
||||
# 1 Extended offline Interrupted (host reset) 50% 669 -
|
||||
# 2 Extended offline Interrupted (host reset) 50% 658 -
|
||||
# 3 Extended offline Interrupted (host reset) 80% 640 -
|
||||
# 4 Extended offline Interrupted (host reset) 90% 631 -
|
||||
# 5 Extended offline Interrupted (host reset) 60% 607 -
|
||||
# 6 Extended offline Interrupted (host reset) 90% 596 -
|
||||
# 7 Extended offline Interrupted (host reset) 10% 582 -
|
||||
# 8 Short offline Completed without error 00% 542 -
|
||||
# 9 Extended offline Interrupted (host reset) 10% 532 -
|
||||
#10 Short offline Completed without error 00% 524 -
|
||||
#11 Short offline Completed without error 00% 513 -
|
||||
#12 Short offline Aborted by host 10% 510 -
|
||||
#13 Extended offline Interrupted (host reset) 80% 508 -
|
||||
#14 Extended offline Interrupted (host reset) 90% 489 -
|
||||
#15 Extended offline Interrupted (host reset) 70% 485 -
|
||||
#16 Short offline Completed without error 00% 481 -
|
||||
#17 Short offline Completed without error 00% 473 -
|
||||
#18 Short offline Completed without error 00% 471 -
|
||||
#19 Short offline Completed without error 00% 467 -
|
||||
#20 Extended offline Interrupted (host reset) 60% 464 -
|
||||
#21 Short offline Aborted by host 70% 460 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-RELEASE-p11 amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 14.0-CURRENT amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Apr 10 00:46:40 2022 CEST
|
||||
Local Time is: Tue Nov 15 11:29:26 2022 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,23 +64,23 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 144 142 021 - 1783
|
||||
4 Start_Stop_Count -O--CK 053 053 000 - 47036
|
||||
3 Spin_Up_Time POS--K 143 142 021 - 1850
|
||||
4 Start_Stop_Count -O--CK 003 003 000 - 97223
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 090 090 000 - 7368
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 9232
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 135
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 89
|
||||
193 Load_Cycle_Count -O--CK 095 095 000 - 316601
|
||||
194 Temperature_Celsius -O---K 120 095 000 - 23
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 395
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 255
|
||||
193 Load_Cycle_Count -O--CK 066 066 000 - 403330
|
||||
194 Temperature_Celsius -O---K 117 095 000 - 26
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
240 Head_Flying_Hours -O--CK 093 093 000 - 5158
|
||||
240 Head_Flying_Hours -O--CK 092 092 000 - 6187
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -131,10 +131,10 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 23 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/30 Celsius
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/26 Celsius
|
||||
Lifetime Min/Max Temperature: 14/48 Celsius
|
||||
Specified Max Operating Temperature: 33 Celsius
|
||||
Specified Max Operating Temperature: 35 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -145,7 +145,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (16)
|
||||
Temperature History Size (Index): 128 (50)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -163,10 +163,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 11 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 134173 Vendor specific
|
||||
0x8000 4 786 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Mar 8 12:30:12 2022 EST
|
||||
Local Time is: Tue Mar 8 14:06:41 2022 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,7 +68,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 658
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 094 094 000 - 4487
|
||||
9 Power_On_Hours -O--CK 094 094 000 - 4489
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 652
|
||||
@@ -76,11 +76,11 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 096 096 000 - 17180131332
|
||||
190 Airflow_Temperature_Cel -O---K 070 060 040 - 30 (Min/Max 20/30)
|
||||
190 Airflow_Temperature_Cel -O---K 069 060 040 - 31 (Min/Max 20/31)
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 133
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 229
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 428
|
||||
194 Temperature_Celsius -O---K 113 103 000 - 30
|
||||
194 Temperature_Celsius -O---K 112 103 000 - 31
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -289,8 +289,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/29 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/31 Celsius
|
||||
Lifetime Min/Max Temperature: 18/40 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -302,7 +302,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (58)
|
||||
Temperature History Size (Index): 128 (25)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -322,10 +322,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 13 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 13 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 2337 Vendor specific
|
||||
0x8000 4 8121 Vendor specific
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Black Mobile
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Jan 7 14:10:47 2021 CET
|
||||
Local Time is: Fri Jan 15 14:16:15 2021 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,26 +64,26 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 143 141 021 - 1833
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1699
|
||||
3 Spin_Up_Time POS--K 143 141 021 - 1816
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1701
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 068 068 000 - 23787
|
||||
9 Power_On_Hours -O--CK 068 068 000 - 23788
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1698
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1700
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 394
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 41
|
||||
193 Load_Cycle_Count -O--CK 021 021 000 - 537454
|
||||
194 Temperature_Celsius -O---K 119 096 000 - 24
|
||||
193 Load_Cycle_Count -O--CK 021 021 000 - 537460
|
||||
194 Temperature_Celsius -O---K 121 096 000 - 22
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
|
||||
240 Head_Flying_Hours -O--CK 069 069 000 - 22995
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 15782135929
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 38745500174
|
||||
240 Head_Flying_Hours -O--CK 069 069 000 - 22997
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 15794892756
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 38768657746
|
||||
254 Free_Fall_Sensor -O--CK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -135,8 +135,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 24 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/24 Celsius
|
||||
Current Temperature: 22 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/22 Celsius
|
||||
Lifetime Min/Max Temperature: 16/47 Celsius
|
||||
Specified Max Operating Temperature: 30 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -149,7 +149,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (55)
|
||||
Temperature History Size (Index): 128 (33)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -167,10 +167,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 5055 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 284 Vendor specific
|
||||
0x8000 4 233 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p7-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -12,7 +12,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Jan 28 08:31:31 2021 UTC
|
||||
Local Time is: Fri Jan 29 05:11:22 2021 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 153 149 021 - 1308
|
||||
4 Start_Stop_Count -O--CK 058 058 000 - 42466
|
||||
3 Spin_Up_Time POS--K 155 149 021 - 1233
|
||||
4 Start_Stop_Count -O--CK 058 058 000 - 42553
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 5981
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 5986
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 4559
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 4561
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 92
|
||||
193 Load_Cycle_Count -O--CK 155 155 000 - 137475
|
||||
194 Temperature_Celsius -O---K 111 100 000 - 32
|
||||
193 Load_Cycle_Count -O--CK 155 155 000 - 137930
|
||||
194 Temperature_Celsius -O---K 118 100 000 - 25
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/33 Celsius
|
||||
Current Temperature: 25 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/27 Celsius
|
||||
Lifetime Min/Max Temperature: 17/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (63)
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -159,10 +159,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 32 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 32 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 22 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 22 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 4131 Vendor specific
|
||||
0x8000 4 5669 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p19-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p20-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -12,7 +12,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Jul 13 10:16:24 2021 UTC
|
||||
Local Time is: Wed Sep 15 11:56:26 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,18 +63,18 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 154 146 021 - 1258
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2853
|
||||
3 Spin_Up_Time POS--K 152 146 021 - 1391
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2859
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 089 089 000 - 8186
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 8817
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2846
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2852
|
||||
191 G-Sense_Error_Rate -O--CK 073 073 000 - 27
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 45
|
||||
193 Load_Cycle_Count -O--CK 082 082 000 - 354038
|
||||
194 Temperature_Celsius -O---K 104 096 000 - 39
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 47
|
||||
193 Load_Cycle_Count -O--CK 082 082 000 - 354126
|
||||
194 Temperature_Celsius -O---K 105 096 000 - 38
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/39 Celsius
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/40 Celsius
|
||||
Lifetime Min/Max Temperature: 22/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (87)
|
||||
Temperature History Size (Index): 128 (95)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -159,10 +159,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 2675 Vendor specific
|
||||
0x8000 4 1722222 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p16-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p18-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 17 04:58:43 2021 UTC
|
||||
Local Time is: Sat Jun 19 12:08:42 2021 WIB
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,19 +63,19 @@ SCT capabilities: (0x7035) SCT Status supported.
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 7356
|
||||
3 Spin_Up_Time POS--K 152 149 021 - 1383
|
||||
4 Start_Stop_Count -O--CK 077 077 000 - 23909
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 7429
|
||||
3 Spin_Up_Time POS--K 156 149 021 - 1191
|
||||
4 Start_Stop_Count -O--CK 074 074 000 - 26393
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 1
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 5532
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 5615
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2619
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 135
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 70
|
||||
193 Load_Cycle_Count -O--CK 186 186 000 - 44605
|
||||
194 Temperature_Celsius -O---K 089 084 000 - 54
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2638
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 136
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 71
|
||||
193 Load_Cycle_Count -O--CK 182 182 000 - 55129
|
||||
194 Temperature_Celsius -O---K 098 084 000 - 45
|
||||
196 Reallocated_Event_Count -O--CK 199 199 000 - 1
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -130,8 +130,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 54 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/59 Celsius
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/51 Celsius
|
||||
Lifetime Min/Max Temperature: 23/59 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (110)
|
||||
Temperature History Size (Index): 128 (42)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -161,10 +161,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 57776 Vendor specific
|
||||
0x8000 4 86429 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Jan 23 15:07:27 2021 GMT
|
||||
Local Time is: Sat Jan 23 15:18:06 2021 GMT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -74,8 +74,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 35
|
||||
191 G-Sense_Error_Rate -O--CK 092 092 000 - 8
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 18
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 3306932
|
||||
194 Temperature_Celsius -O---K 100 085 000 - 43
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 3306954
|
||||
194 Temperature_Celsius -O---K 101 085 000 - 42
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -130,7 +130,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 43 Celsius
|
||||
Current Temperature: 42 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/52 Celsius
|
||||
Lifetime Min/Max Temperature: 0/58 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (73)
|
||||
Temperature History Size (Index): 128 (84)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -166,5 +166,5 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 15672819 Vendor specific
|
||||
0x8000 4 15673458 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jan 2 13:06:47 2021 CET
|
||||
Local Time is: Sat Jan 23 18:39:04 2021 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,18 +64,18 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 148 146 021 - 1566
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2745
|
||||
3 Spin_Up_Time POS--K 150 146 021 - 1491
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2844
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 832
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 875
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1100
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1144
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 958
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2865
|
||||
194 Temperature_Celsius -O---K 119 102 000 - 24
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1000
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2932
|
||||
194 Temperature_Celsius -O---K 116 102 000 - 27
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -134,8 +134,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Stand-by (1)
|
||||
Current Temperature: 24 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/24 Celsius
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/27 Celsius
|
||||
Lifetime Min/Max Temperature: 17/41 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -147,7 +147,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (6)
|
||||
Temperature History Size (Index): 128 (99)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -170,7 +170,7 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 192 Vendor specific
|
||||
0x8000 4 26835 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Blue Mobile
|
||||
@@ -10,10 +10,10 @@ Firmware Version: 01.01A01
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Aug 29 20:07:05 2021 CEST
|
||||
Local Time is: Sun Apr 17 10:55:09 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 152 150 021 - 1375
|
||||
4 Start_Stop_Count -O--CK 001 001 000 - 421883
|
||||
3 Spin_Up_Time POS--K 152 150 021 - 1391
|
||||
4 Start_Stop_Count -O--CK 001 001 000 - 422312
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 061 061 000 - 28484
|
||||
9 Power_On_Hours -O--CK 059 059 000 - 30389
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 98
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 102
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 60
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 637379
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 64
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 637852
|
||||
194 Temperature_Celsius -O---K 115 082 000 - 28
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
@@ -130,9 +130,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Stand-by (1)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/29 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/28 Celsius
|
||||
Lifetime Min/Max Temperature: 0/62 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -144,7 +144,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (91)
|
||||
Temperature History Size (Index): 128 (30)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -162,10 +162,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 86 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 87 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 3405485 Vendor specific
|
||||
0x8000 4 1267233 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Aug 3 15:34:57 2021 -03
|
||||
Local Time is: Tue Aug 3 16:01:57 2021 -03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,7 +68,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 078 078 000 - 22498
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 3437
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 3438
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2722
|
||||
@@ -191,7 +191,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (81)
|
||||
Temperature History Size (Index): 128 (108)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -214,5 +214,5 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 18150 Vendor specific
|
||||
0x8000 4 19768 Vendor specific
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Aug 20 14:27:22 2020 +08
|
||||
Local Time is: Wed Aug 26 11:20:08 2020 +08
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,23 +64,23 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 152 143 021 - 1383
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2589
|
||||
3 Spin_Up_Time POS--K 151 143 021 - 1408
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2603
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 089 089 000 - 8191
|
||||
9 Power_On_Hours -O--CK 089 089 000 - 8278
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2087
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2101
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 059 047 040 - 41 (Min/Max 24/41)
|
||||
190 Airflow_Temperature_Cel -O---K 063 047 040 - 37 (Min/Max 23/40)
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 125
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 111
|
||||
193 Load_Cycle_Count -O--CK 151 151 000 - 149904
|
||||
194 Temperature_Celsius -O---K 102 090 000 - 41
|
||||
193 Load_Cycle_Count -O--CK 149 149 000 - 154057
|
||||
194 Temperature_Celsius -O---K 106 090 000 - 37
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -153,8 +153,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/41 Celsius
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/41 Celsius
|
||||
Lifetime Min/Max Temperature: -13/53 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -166,7 +166,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (31)
|
||||
Temperature History Size (Index): 128 (57)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -186,10 +186,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 12 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 13 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 21381 Vendor specific
|
||||
0x8000 4 10249 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Apr 27 23:02:53 2021 EEST
|
||||
Local Time is: Sun May 2 21:13:28 2021 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,22 +68,22 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 980
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 095 095 000 - 4171
|
||||
9 Power_On_Hours -O--CK 095 095 000 - 4289
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 851
|
||||
191 G-Sense_Error_Rate -O--CK 065 065 000 - 35
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 174
|
||||
193 Load_Cycle_Count -O--CK 176 176 000 - 72031
|
||||
194 Temperature_Celsius -O---K 116 099 000 - 27
|
||||
193 Load_Cycle_Count -O--CK 173 173 000 - 83274
|
||||
194 Temperature_Celsius -O---K 115 099 000 - 28
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
|
||||
240 Head_Flying_Hours -O--CK 097 097 000 - 2722
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 9111410397
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 7282915533
|
||||
240 Head_Flying_Hours -O--CK 097 097 000 - 2828
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 9236747455
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 7285465204
|
||||
254 Free_Fall_Sensor -O--CK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -139,8 +139,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/27 Celsius
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/28 Celsius
|
||||
Lifetime Min/Max Temperature: 12/45 Celsius
|
||||
Specified Max Operating Temperature: 29 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -153,7 +153,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (89)
|
||||
Temperature History Size (Index): 128 (3)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -176,5 +176,5 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 6076 Vendor specific
|
||||
0x8000 4 431092 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Feb 9 15:21:56 2022 EST
|
||||
Local Time is: Thu Feb 10 04:09:56 2022 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,13 +68,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1712
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2484
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2496
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1710
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 377
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 31
|
||||
193 Load_Cycle_Count -O--CK 192 192 000 - 24711
|
||||
193 Load_Cycle_Count -O--CK 192 192 000 - 24738
|
||||
194 Temperature_Celsius -O---K 112 100 000 - 31
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
@@ -161,8 +161,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (65535)
|
||||
Invalid Temperature History Size or Index
|
||||
Temperature History Size (Index): 128 (124)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -180,10 +179,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 22 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 18 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 1833 Vendor specific
|
||||
0x8000 4 47866 Vendor specific
|
||||
|
||||
|
Reference in New Issue
Block a user