smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p13-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p19-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Sat Feb 13 15:25:30 2021 UTC
|
||||
Local Time is: Sun Sep 19 19:12:07 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -66,17 +66,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 240 239 021 - 966
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 142
|
||||
3 Spin_Up_Time POS--K 240 239 021 - 975
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 159
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 017 017 000 - 61090
|
||||
9 Power_On_Hours -O--CK 010 010 000 - 66325
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 141
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 133
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 142
|
||||
194 Temperature_Celsius -O---K 108 106 000 - 39
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 158
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 150
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 159
|
||||
194 Temperature_Celsius -O---K 108 105 000 - 39
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -134,8 +134,8 @@ SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/41 Celsius
|
||||
Lifetime Min/Max Temperature: 36/41 Celsius
|
||||
Power Cycle Min/Max Temperature: 37/41 Celsius
|
||||
Lifetime Min/Max Temperature: 37/42 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (6)
|
||||
Temperature History Size (Index): 478 (256)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 80 (8.0 seconds)
|
||||
@@ -163,5 +163,5 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 233805 Vendor specific
|
||||
0x8000 4 1930991 Vendor specific
|
||||
|
||||
|
Reference in New Issue