@@ -11,7 +11,7 @@ User Capacity: 80,026,361,856 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Mon Dec 19 02:54:48 2022 CST
|
||||
Local Time is: Mon Dec 19 03:11:04 2022 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 128 (quiet), recommended: 128
|
||||
@@ -73,7 +73,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
12 Power_Cycle_Count -O--CK 091 091 000 - 9968
|
||||
192 Power-Off_Retract_Count -O--CK 192 192 000 - 6692
|
||||
193 Load_Cycle_Count -O--CK 195 195 000 - 15324
|
||||
194 Temperature_Celsius -O---K 106 087 000 - 37
|
||||
194 Temperature_Celsius -O---K 105 087 000 - 38
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
@@ -269,9 +269,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 37/37 Celsius
|
||||
Lifetime Min/Max Temperature: 37/56 Celsius
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 37/38 Celsius
|
||||
Lifetime Min/Max Temperature: ?/56 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -279,7 +279,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/60 Celsius
|
||||
Min/Max Temperature Limit: 1/85 Celsius
|
||||
Temperature History Size (Index): 128 (68)
|
||||
Temperature History Size (Index): 128 (84)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -299,5 +299,5 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 638 Vendor specific
|
||||
0x8000 4 1613 Vendor specific
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Fri Aug 13 11:52:03 2021 -03
|
||||
Local Time is: Mon Aug 16 16:42:17 2021 -03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -62,21 +62,21 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 2
|
||||
3 Spin_Up_Time PO---- 151 150 021 - 3416
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3864
|
||||
3 Spin_Up_Time PO---- 151 150 021 - 3433
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3866
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 052 052 000 - 35332
|
||||
9 Power_On_Hours -O--CK 052 052 000 - 35409
|
||||
10 Spin_Retry_Count PO--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count PO--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2088
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2090
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 098 000 - 2
|
||||
188 Command_Timeout -O--CK 100 098 000 - 29
|
||||
190 Airflow_Temperature_Cel -O---K 073 056 040 - 27
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1490
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 4369
|
||||
194 Temperature_Celsius -O---K 116 099 000 - 27
|
||||
190 Airflow_Temperature_Cel -O---K 068 056 040 - 32
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1492
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 4371
|
||||
194 Temperature_Celsius -O---K 111 099 000 - 32
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
@@ -224,9 +224,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/32 Celsius
|
||||
Lifetime Min/Max Temperature: 25/44 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/32 Celsius
|
||||
Lifetime Min/Max Temperature: 27/44 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -234,7 +234,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/85 Celsius
|
||||
Temperature History Size (Index): 128 (72)
|
||||
Temperature History Size (Index): 128 (65)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -253,6 +253,6 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 178835 Vendor specific
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 1012 Vendor specific
|
||||
|
||||
|
@@ -11,11 +11,11 @@ User Capacity: 80,025,280,000 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Sun Jun 20 20:16:18 2021 EDT
|
||||
Local Time is: Tue Jun 22 14:25:06 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 128 (quiet), recommended: 128
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
@@ -63,16 +63,16 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 159 143 021 - 1008
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4622
|
||||
3 Spin_Up_Time PO---- 159 143 021 - 1050
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4638
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 077 077 000 - 16806
|
||||
9 Power_On_Hours -O--CK 077 077 000 - 16818
|
||||
10 Spin_Retry_Count PO--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3923
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1265
|
||||
193 Load_Cycle_Count -O--CK 070 070 000 - 391091
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3939
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1269
|
||||
193 Load_Cycle_Count -O--CK 070 070 000 - 391187
|
||||
194 Temperature_Celsius -O---K 107 092 000 - 36
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
@@ -187,8 +187,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 22 Celsius
|
||||
Power Cycle Min/Max Temperature: --/22 Celsius
|
||||
Current Temperature: 40 Celsius
|
||||
Power Cycle Min/Max Temperature: --/40 Celsius
|
||||
Lifetime Min/Max Temperature: --/ 0 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -196,7 +196,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/65 Celsius
|
||||
Min/Max Temperature Limit: 1/70 Celsius
|
||||
Temperature History Size (Index): 128 (95)
|
||||
Temperature History Size (Index): 128 (127)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -215,6 +215,6 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 2102 Vendor specific
|
||||
0x000a 2 16 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 6522 Vendor specific
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE i386] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p5 i386] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Caviar SE
|
||||
@@ -10,7 +10,7 @@ User Capacity: 80,026,361,856 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-6 (minor revision not indicated)
|
||||
Local Time is: Wed Dec 16 14:30:57 2020 EET
|
||||
Local Time is: Fri Nov 5 09:49:39 2021 EET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -63,15 +63,15 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 190 161 021 - 1475
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3148
|
||||
3 Spin_Up_Time PO---- 184 161 021 - 1775
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3154
|
||||
5 Reallocated_Sector_Ct PO--CK 197 197 140 - 17
|
||||
7 Seek_Error_Rate POSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 011 011 000 - 65056
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 72815
|
||||
10 Spin_Retry_Count PO--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2962
|
||||
194 Temperature_Celsius -O---K 110 084 000 - 33
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2968
|
||||
194 Temperature_Celsius -O---K 106 084 000 - 37
|
||||
196 Reallocated_Event_Count -O--CK 199 199 000 - 1
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Caviar SE Serial ATA
|
||||
@@ -8,9 +8,9 @@ Serial Number: --
|
||||
Firmware Version: 10.01E01
|
||||
User Capacity: 80,032,038,912 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Wed Aug 19 06:36:01 2020 PDT
|
||||
Local Time is: Fri Apr 22 08:08:22 2022 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -63,15 +63,15 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 167 166 021 - 2650
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 123
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 124
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 112511
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 127157
|
||||
10 Spin_Retry_Count PO--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 110
|
||||
190 Airflow_Temperature_Cel -O---K 075 053 000 - 25
|
||||
194 Temperature_Celsius -O---K 118 096 000 - 25
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 111
|
||||
190 Airflow_Temperature_Cel -O---K 078 053 000 - 22
|
||||
194 Temperature_Celsius -O---K 121 096 000 - 22
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
@@ -108,24 +108,24 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 46970 -
|
||||
# 2 Short offline Completed without error 00% 46946 -
|
||||
# 3 Short offline Completed without error 00% 46922 -
|
||||
# 4 Short offline Completed without error 00% 46898 -
|
||||
# 5 Extended offline Completed without error 00% 46876 -
|
||||
# 6 Short offline Completed without error 00% 46874 -
|
||||
# 7 Short offline Completed without error 00% 46851 -
|
||||
# 8 Short offline Completed without error 00% 46827 -
|
||||
# 9 Short offline Completed without error 00% 46803 -
|
||||
#10 Short offline Completed without error 00% 46779 -
|
||||
#11 Short offline Completed without error 00% 46755 -
|
||||
#12 Short offline Completed without error 00% 46731 -
|
||||
#13 Extended offline Completed without error 00% 46708 -
|
||||
#14 Short offline Completed without error 00% 46707 -
|
||||
#15 Short offline Completed without error 00% 46683 -
|
||||
#16 Short offline Completed without error 00% 46659 -
|
||||
#17 Short offline Completed without error 00% 46635 -
|
||||
#18 Short offline Completed without error 00% 46611 -
|
||||
# 1 Short offline Completed without error 00% 61615 -
|
||||
# 2 Short offline Completed without error 00% 61592 -
|
||||
# 3 Short offline Completed without error 00% 61568 -
|
||||
# 4 Short offline Completed without error 00% 61544 -
|
||||
# 5 Short offline Completed without error 00% 61520 -
|
||||
# 6 Short offline Completed without error 00% 61496 -
|
||||
# 7 Extended offline Completed without error 00% 61473 -
|
||||
# 8 Short offline Completed without error 00% 61472 -
|
||||
# 9 Short offline Completed without error 00% 61448 -
|
||||
#10 Short offline Completed without error 00% 61424 -
|
||||
#11 Short offline Completed without error 00% 61400 -
|
||||
#12 Short offline Completed without error 00% 61376 -
|
||||
#13 Short offline Completed without error 00% 61352 -
|
||||
#14 Short offline Completed without error 00% 61328 -
|
||||
#15 Extended offline Completed without error 00% 61305 -
|
||||
#16 Short offline Completed without error 00% 61304 -
|
||||
#17 Short offline Completed without error 00% 61280 -
|
||||
#18 Short offline Completed without error 00% 61256 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -141,8 +141,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 25 Celsius
|
||||
Power Cycle Min/Max Temperature: --/38 Celsius
|
||||
Current Temperature: 22 Celsius
|
||||
Power Cycle Min/Max Temperature: --/35 Celsius
|
||||
Lifetime Min/Max Temperature: --/48 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -150,7 +150,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/65 Celsius
|
||||
Min/Max Temperature Limit: 1/70 Celsius
|
||||
Temperature History Size (Index): 128 (40)
|
||||
Temperature History Size (Index): 128 (84)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -163,8 +163,8 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 43 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 25372658 Vendor specific
|
||||
0x000a 2 20 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 4630816 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -10,7 +10,7 @@ User Capacity: 80,000,000,000 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Sat Jan 8 00:45:47 2022 EST
|
||||
Local Time is: Mon Jan 10 15:28:58 2022 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -63,16 +63,16 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 165 160 021 - 2741
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1753
|
||||
3 Spin_Up_Time PO---- 166 160 021 - 2683
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1758
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 8866
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 8867
|
||||
10 Spin_Retry_Count PO--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1751
|
||||
190 Airflow_Temperature_Cel -O---K 069 040 045 Past 31
|
||||
194 Temperature_Celsius -O---K 112 083 000 - 31
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1756
|
||||
190 Airflow_Temperature_Cel -O---K 068 040 045 Past 32
|
||||
194 Temperature_Celsius -O---K 111 083 000 - 32
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
@@ -126,8 +126,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: --/33 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: --/32 Celsius
|
||||
Lifetime Min/Max Temperature: --/64 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -135,7 +135,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/65 Celsius
|
||||
Min/Max Temperature Limit: 1/70 Celsius
|
||||
Temperature History Size (Index): 128 (30)
|
||||
Temperature History Size (Index): 128 (82)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -148,6 +148,6 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 1017 Vendor specific
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 1553 Vendor specific
|
||||
|
||||
|
Reference in New Issue