@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Fri Aug 13 11:52:03 2021 -03
|
||||
Local Time is: Mon Aug 16 16:42:17 2021 -03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -62,21 +62,21 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 2
|
||||
3 Spin_Up_Time PO---- 151 150 021 - 3416
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3864
|
||||
3 Spin_Up_Time PO---- 151 150 021 - 3433
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3866
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 052 052 000 - 35332
|
||||
9 Power_On_Hours -O--CK 052 052 000 - 35409
|
||||
10 Spin_Retry_Count PO--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count PO--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2088
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2090
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 098 000 - 2
|
||||
188 Command_Timeout -O--CK 100 098 000 - 29
|
||||
190 Airflow_Temperature_Cel -O---K 073 056 040 - 27
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1490
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 4369
|
||||
194 Temperature_Celsius -O---K 116 099 000 - 27
|
||||
190 Airflow_Temperature_Cel -O---K 068 056 040 - 32
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1492
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 4371
|
||||
194 Temperature_Celsius -O---K 111 099 000 - 32
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
@@ -224,9 +224,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/32 Celsius
|
||||
Lifetime Min/Max Temperature: 25/44 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/32 Celsius
|
||||
Lifetime Min/Max Temperature: 27/44 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -234,7 +234,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/85 Celsius
|
||||
Temperature History Size (Index): 128 (72)
|
||||
Temperature History Size (Index): 128 (65)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -253,6 +253,6 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 178835 Vendor specific
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 1012 Vendor specific
|
||||
|
||||
|
Reference in New Issue