1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 14, modified: 3797)

This commit is contained in:
Andrey Ponomarenko
2023-02-14 02:15:20 +03:00
parent 274416644b
commit a41331e270
3811 changed files with 71570 additions and 67733 deletions

View File

@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Fri Aug 13 11:52:03 2021 -03
Local Time is: Mon Aug 16 16:42:17 2021 -03
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -62,21 +62,21 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 2
3 Spin_Up_Time PO---- 151 150 021 - 3416
4 Start_Stop_Count -O--CK 097 097 000 - 3864
3 Spin_Up_Time PO---- 151 150 021 - 3433
4 Start_Stop_Count -O--CK 097 097 000 - 3866
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-- 200 200 051 - 0
9 Power_On_Hours -O--CK 052 052 000 - 35332
9 Power_On_Hours -O--CK 052 052 000 - 35409
10 Spin_Retry_Count PO--C- 100 100 051 - 0
11 Calibration_Retry_Count PO--C- 100 100 051 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 2088
12 Power_Cycle_Count -O--CK 098 098 000 - 2090
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 098 000 - 2
188 Command_Timeout -O--CK 100 098 000 - 29
190 Airflow_Temperature_Cel -O---K 073 056 040 - 27
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1490
193 Load_Cycle_Count -O--CK 199 199 000 - 4369
194 Temperature_Celsius -O---K 116 099 000 - 27
190 Airflow_Temperature_Cel -O---K 068 056 040 - 32
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1492
193 Load_Cycle_Count -O--CK 199 199 000 - 4371
194 Temperature_Celsius -O---K 111 099 000 - 32
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--C- 200 200 000 - 0
198 Offline_Uncorrectable ----C- 200 200 000 - 0
@@ -224,9 +224,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 27 Celsius
Power Cycle Min/Max Temperature: 25/32 Celsius
Lifetime Min/Max Temperature: 25/44 Celsius
Current Temperature: 32 Celsius
Power Cycle Min/Max Temperature: 32/32 Celsius
Lifetime Min/Max Temperature: 27/44 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
@@ -234,7 +234,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/85 Celsius
Temperature History Size (Index): 128 (72)
Temperature History Size (Index): 128 (65)
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
@@ -253,6 +253,6 @@ ID Size Value Description
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
0x8000 4 178835 Vendor specific
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET