mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 14, modified: 3797)
This commit is contained in:
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Caviar SE Serial ATA
|
||||
@@ -8,9 +8,9 @@ Serial Number: --
|
||||
Firmware Version: 10.01E01
|
||||
User Capacity: 80,032,038,912 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Wed Aug 19 06:36:01 2020 PDT
|
||||
Local Time is: Fri Apr 22 08:08:22 2022 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -63,15 +63,15 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 167 166 021 - 2650
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 123
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 124
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 112511
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 127157
|
||||
10 Spin_Retry_Count PO--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 110
|
||||
190 Airflow_Temperature_Cel -O---K 075 053 000 - 25
|
||||
194 Temperature_Celsius -O---K 118 096 000 - 25
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 111
|
||||
190 Airflow_Temperature_Cel -O---K 078 053 000 - 22
|
||||
194 Temperature_Celsius -O---K 121 096 000 - 22
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
@@ -108,24 +108,24 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 46970 -
|
||||
# 2 Short offline Completed without error 00% 46946 -
|
||||
# 3 Short offline Completed without error 00% 46922 -
|
||||
# 4 Short offline Completed without error 00% 46898 -
|
||||
# 5 Extended offline Completed without error 00% 46876 -
|
||||
# 6 Short offline Completed without error 00% 46874 -
|
||||
# 7 Short offline Completed without error 00% 46851 -
|
||||
# 8 Short offline Completed without error 00% 46827 -
|
||||
# 9 Short offline Completed without error 00% 46803 -
|
||||
#10 Short offline Completed without error 00% 46779 -
|
||||
#11 Short offline Completed without error 00% 46755 -
|
||||
#12 Short offline Completed without error 00% 46731 -
|
||||
#13 Extended offline Completed without error 00% 46708 -
|
||||
#14 Short offline Completed without error 00% 46707 -
|
||||
#15 Short offline Completed without error 00% 46683 -
|
||||
#16 Short offline Completed without error 00% 46659 -
|
||||
#17 Short offline Completed without error 00% 46635 -
|
||||
#18 Short offline Completed without error 00% 46611 -
|
||||
# 1 Short offline Completed without error 00% 61615 -
|
||||
# 2 Short offline Completed without error 00% 61592 -
|
||||
# 3 Short offline Completed without error 00% 61568 -
|
||||
# 4 Short offline Completed without error 00% 61544 -
|
||||
# 5 Short offline Completed without error 00% 61520 -
|
||||
# 6 Short offline Completed without error 00% 61496 -
|
||||
# 7 Extended offline Completed without error 00% 61473 -
|
||||
# 8 Short offline Completed without error 00% 61472 -
|
||||
# 9 Short offline Completed without error 00% 61448 -
|
||||
#10 Short offline Completed without error 00% 61424 -
|
||||
#11 Short offline Completed without error 00% 61400 -
|
||||
#12 Short offline Completed without error 00% 61376 -
|
||||
#13 Short offline Completed without error 00% 61352 -
|
||||
#14 Short offline Completed without error 00% 61328 -
|
||||
#15 Extended offline Completed without error 00% 61305 -
|
||||
#16 Short offline Completed without error 00% 61304 -
|
||||
#17 Short offline Completed without error 00% 61280 -
|
||||
#18 Short offline Completed without error 00% 61256 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -141,8 +141,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 25 Celsius
|
||||
Power Cycle Min/Max Temperature: --/38 Celsius
|
||||
Current Temperature: 22 Celsius
|
||||
Power Cycle Min/Max Temperature: --/35 Celsius
|
||||
Lifetime Min/Max Temperature: --/48 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -150,7 +150,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/65 Celsius
|
||||
Min/Max Temperature Limit: 1/70 Celsius
|
||||
Temperature History Size (Index): 128 (40)
|
||||
Temperature History Size (Index): 128 (84)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -163,8 +163,8 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 43 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 25372658 Vendor specific
|
||||
0x000a 2 20 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 4630816 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
Reference in New Issue
Block a user