mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 14, modified: 3797)
This commit is contained in:
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Dec 10 16:30:06 2021 CET
|
||||
Local Time is: Fri Dec 31 20:15:31 2021 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -67,13 +67,13 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 149
|
||||
12 Power_Cycle_Count PO--CK 100 100 001 - 226
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 656
|
||||
12 Power_Cycle_Count PO--CK 100 100 001 - 230
|
||||
181 Program_Fail_Cnt_Total PO--CK 100 100 001 - 0
|
||||
182 Erase_Fail_Count_Total PO--CK 100 100 001 - 0
|
||||
177 Wear_Leveling_Count PO--CK 100 100 010 - 5
|
||||
177 Wear_Leveling_Count PO--CK 100 100 010 - 6
|
||||
187 Reported_Uncorrect PO--CK 100 100 001 - 0
|
||||
194 Temperature_Celsius -O---K 067 050 000 - 33 (Min/Max 16/50)
|
||||
194 Temperature_Celsius -O---K 066 050 000 - 34 (Min/Max 16/50)
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
238 Unknown_Attribute ----CK 100 100 000 - 0
|
||||
175 Program_Fail_Count_Chip PO--CK 100 100 000 - 0
|
||||
@@ -81,8 +81,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--CK 100 100 000 - 0
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2053
|
||||
195 Cumulativ_Corrected_ECC POSR-K 100 000 050 Past 0
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 1097329596
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 944312471
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 1402731569
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 986747996
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -128,10 +128,17 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 148 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 86 -
|
||||
# 3 Short offline Self-test routine in progress 90% 3 -
|
||||
# 4 Short offline Self-test routine in progress 90% 3 -
|
||||
# 1 Extended offline Completed without error 00% 598 -
|
||||
# 2 Short offline Completed without error 00% 598 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 597 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 466 -
|
||||
# 5 Extended offline Completed without error 00% 244 -
|
||||
# 6 Short offline Completed without error 00% 244 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 238 -
|
||||
# 8 Extended offline Completed without error 00% 148 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 86 -
|
||||
#10 Short offline Self-test routine in progress 90% 3 -
|
||||
#11 Short offline Self-test routine in progress 90% 3 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -147,8 +154,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/38 Celsius
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/40 Celsius
|
||||
Lifetime Min/Max Temperature: 16/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -157,29 +164,29 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (134)
|
||||
Temperature History Size (Index): 478 (368)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 226 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 149 --- Power-on Hours
|
||||
0x01 0x018 6 1097329596 --- Logical Sectors Written
|
||||
0x01 0x020 6 18048178 --- Number of Write Commands
|
||||
0x01 0x028 6 944312471 --- Logical Sectors Read
|
||||
0x01 0x030 6 14191060 --- Number of Read Commands
|
||||
0x01 0x008 4 230 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 656 --- Power-on Hours
|
||||
0x01 0x018 6 1402731569 --- Logical Sectors Written
|
||||
0x01 0x020 6 22537058 --- Number of Write Commands
|
||||
0x01 0x028 6 986747996 --- Logical Sectors Read
|
||||
0x01 0x030 6 15047608 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 216 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 218 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 33 --- Average Short Term Temperature
|
||||
0x05 0x008 1 34 --- Current Temperature
|
||||
0x05 0x010 1 34 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 50 --- Highest Temperature
|
||||
0x05 0x028 1 16 --- Lowest Temperature
|
||||
0x05 0x030 1 33 --- Highest Average Short Term Temperature
|
||||
0x05 0x030 1 34 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
@@ -188,8 +195,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 612 --- Number of Hardware Resets
|
||||
0x06 0x010 4 60 --- Number of ASR Events
|
||||
0x06 0x008 4 636 --- Number of Hardware Resets
|
||||
0x06 0x010 4 66 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 N-- Percentage Used Endurance Indicator
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: M.2
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Aug 20 14:27:22 2020 +08
|
||||
Local Time is: Wed Aug 26 11:20:08 2020 +08
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,13 +66,13 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 010 - 2
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 536
|
||||
12 Power_Cycle_Count PO--CK 100 100 001 - 969
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 619
|
||||
12 Power_Cycle_Count PO--CK 100 100 001 - 983
|
||||
181 Program_Fail_Cnt_Total PO--CK 100 100 001 - 0
|
||||
182 Erase_Fail_Count_Total PO--CK 100 100 001 - 0
|
||||
177 Wear_Leveling_Count PO--CK 096 096 010 - 60
|
||||
177 Wear_Leveling_Count PO--CK 096 096 010 - 61
|
||||
187 Reported_Uncorrect PO--CK 100 100 001 - 0
|
||||
194 Temperature_Celsius -O---K 048 034 000 - 52 (Min/Max 13/66)
|
||||
194 Temperature_Celsius -O---K 051 034 000 - 49 (Min/Max 13/66)
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
238 Unknown_Attribute ----CK 096 096 000 - 4
|
||||
175 Program_Fail_Count_Chip PO--CK 100 100 000 - 0
|
||||
@@ -80,8 +80,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--CK 100 100 000 - 1
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2043
|
||||
195 Cumulativ_Corrected_ECC POSR-K 100 000 050 Past 0
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 14731613003
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 10873621325
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 14835878868
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 10929416365
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--CK 100 100 000 - 2
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -158,8 +158,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 52 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/58 Celsius
|
||||
Current Temperature: 49 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/53 Celsius
|
||||
Lifetime Min/Max Temperature: 13/66 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -168,24 +168,24 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (236)
|
||||
Temperature History Size (Index): 478 (426)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 969 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 536 --- Power-on Hours
|
||||
0x01 0x018 6 14731613003 --- Logical Sectors Written
|
||||
0x01 0x020 6 214099122 --- Number of Write Commands
|
||||
0x01 0x028 6 10873621325 --- Logical Sectors Read
|
||||
0x01 0x030 6 145493079 --- Number of Read Commands
|
||||
0x01 0x008 4 983 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 619 --- Power-on Hours
|
||||
0x01 0x018 6 14835878868 --- Logical Sectors Written
|
||||
0x01 0x020 6 215689071 --- Number of Write Commands
|
||||
0x01 0x028 6 10929416365 --- Logical Sectors Read
|
||||
0x01 0x030 6 146367647 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 972 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 986 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 52 --- Current Temperature
|
||||
0x05 0x008 1 49 --- Current Temperature
|
||||
0x05 0x010 1 48 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 66 --- Highest Temperature
|
||||
@@ -199,8 +199,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 11091 --- Number of Hardware Resets
|
||||
0x06 0x010 4 277 --- Number of ASR Events
|
||||
0x06 0x008 4 11257 --- Number of Hardware Resets
|
||||
0x06 0x010 4 312 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 4 N-- Percentage Used Endurance Indicator
|
||||
@@ -213,7 +213,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 13 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: M.2
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Nov 20 22:35:06 2020 CET
|
||||
Local Time is: Fri Nov 20 22:36:23 2020 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -72,7 +72,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total PO--CK 100 100 001 - 0
|
||||
177 Wear_Leveling_Count PO--CK 100 100 010 - 1
|
||||
187 Reported_Uncorrect PO--CK 100 100 001 - 0
|
||||
194 Temperature_Celsius -O---K 055 045 000 - 45 (Min/Max 19/55)
|
||||
194 Temperature_Celsius -O---K 056 045 000 - 44 (Min/Max 19/55)
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
238 Unknown_Attribute ----CK 100 100 000 - 0
|
||||
175 Program_Fail_Count_Chip PO--CK 100 100 000 - 0
|
||||
@@ -80,8 +80,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--CK 100 100 000 - 0
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2041
|
||||
195 Cumulativ_Corrected_ECC POSR-K 100 000 050 Past 0
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 343702071
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 146355494
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 343715593
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 146361030
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -144,7 +144,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 45 Celsius
|
||||
Current Temperature: 44 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/47 Celsius
|
||||
Lifetime Min/Max Temperature: 19/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -154,7 +154,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (77)
|
||||
Temperature History Size (Index): 478 (78)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -163,15 +163,15 @@ Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 72 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 6 --- Power-on Hours
|
||||
0x01 0x018 6 343702071 --- Logical Sectors Written
|
||||
0x01 0x020 6 3564699 --- Number of Write Commands
|
||||
0x01 0x028 6 146355494 --- Logical Sectors Read
|
||||
0x01 0x030 6 1177671 --- Number of Read Commands
|
||||
0x01 0x018 6 343715593 --- Logical Sectors Written
|
||||
0x01 0x020 6 3564892 --- Number of Write Commands
|
||||
0x01 0x028 6 146361030 --- Logical Sectors Read
|
||||
0x01 0x030 6 1177750 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 72 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 45 --- Current Temperature
|
||||
0x05 0x008 1 44 --- Current Temperature
|
||||
0x05 0x010 1 - --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 55 --- Highest Temperature
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: M.2
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Feb 11 17:24:01 2021 EST
|
||||
Local Time is: Thu Feb 11 17:32:24 2021 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -72,7 +72,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total PO--CK 100 100 001 - 0
|
||||
177 Wear_Leveling_Count PO--CK 099 099 010 - 19
|
||||
187 Reported_Uncorrect PO--CK 100 100 001 - 0
|
||||
194 Temperature_Celsius -O---K 070 029 000 - 30 (Min/Max 7/71)
|
||||
194 Temperature_Celsius -O---K 064 029 000 - 36 (Min/Max 7/71)
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
238 Unknown_Attribute ----CK 099 099 000 - 1
|
||||
175 Program_Fail_Count_Chip PO--CK 100 100 000 - 0
|
||||
@@ -144,8 +144,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/30 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/36 Celsius
|
||||
Lifetime Min/Max Temperature: 7/71 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -154,7 +154,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (313)
|
||||
Temperature History Size (Index): 478 (321)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -171,7 +171,7 @@ Page Offset Size Value Flags Description
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 840 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x008 1 36 --- Current Temperature
|
||||
0x05 0x010 1 40 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 71 --- Highest Temperature
|
||||
|
@@ -1,8 +1,8 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron BX/MX1/2/3/500, M5/600, 1100 SSDs
|
||||
Model Family: Crucial/Micron Client SSDs
|
||||
Device Model: Micron 1100 SATA 256GB
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
@@ -11,10 +11,11 @@ User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Jan 7 14:54:23 2021 CET
|
||||
Local Time is: Mon Jan 18 10:17:52 2021 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,8 +67,8 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 82
|
||||
12 Power_Cycle_Count PO--CK 100 100 001 - 1064
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 83
|
||||
12 Power_Cycle_Count PO--CK 100 100 001 - 1086
|
||||
181 Program_Fail_Cnt_Total PO--CK 100 100 001 - 0
|
||||
182 Erase_Fail_Count_Total PO--CK 100 100 001 - 0
|
||||
177 Wear_Leveling_Count PO--CK 099 099 010 - 27
|
||||
@@ -80,8 +81,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--CK 100 100 000 - 0
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2059
|
||||
195 Cumulativ_Corrected_ECC POSR-K 100 000 050 Past 0
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 5609313338
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 4102098456
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 5770074595
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 4246261790
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -146,7 +147,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 22 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/22 Celsius
|
||||
Power Cycle Min/Max Temperature: 18/22 Celsius
|
||||
Lifetime Min/Max Temperature: 13/51 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -155,22 +156,22 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (208)
|
||||
Temperature History Size (Index): 478 (269)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1064 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 82 --- Power-on Hours
|
||||
0x01 0x018 6 5609313338 --- Logical Sectors Written
|
||||
0x01 0x020 6 105552244 --- Number of Write Commands
|
||||
0x01 0x028 6 4102098456 --- Logical Sectors Read
|
||||
0x01 0x030 6 71151855 --- Number of Read Commands
|
||||
0x01 0x008 4 1086 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 83 --- Power-on Hours
|
||||
0x01 0x018 6 5770074595 --- Logical Sectors Written
|
||||
0x01 0x020 6 109029008 --- Number of Write Commands
|
||||
0x01 0x028 6 4246261790 --- Logical Sectors Read
|
||||
0x01 0x030 6 74205699 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 1045 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 1067 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 22 --- Current Temperature
|
||||
0x05 0x010 1 25 --- Average Short Term Temperature
|
||||
@@ -186,8 +187,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 3377 --- Number of Hardware Resets
|
||||
0x06 0x010 4 67 --- Number of ASR Events
|
||||
0x06 0x008 4 3456 --- Number of Hardware Resets
|
||||
0x06 0x010 4 72 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 1 N-- Percentage Used Endurance Indicator
|
||||
@@ -200,5 +201,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 16 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p1 amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,8 +14,8 @@ Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Mar 17 22:22:56 2021 CDT
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Aug 12 16:01:24 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -23,7 +23,7 @@ APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
@@ -37,7 +37,7 @@ Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 340) seconds.
|
||||
data collection: ( 1599) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
@@ -55,7 +55,7 @@ Error logging capability: (0x01) Error logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 17) minutes.
|
||||
recommended polling time: ( 20) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
@@ -67,12 +67,12 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 4716
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 30
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 5942
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 44
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 100 100 000 - 4
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 25
|
||||
173 Ave_Block-Erase_Count -O--CK 100 100 000 - 5
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 35
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
@@ -83,9 +83,9 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 1
|
||||
202 Percent_Lifetime_Remain ----CK 100 100 001 - 0
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 6107363228
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 190855145
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 81590480
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 7835109003
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 244847250
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 102010163
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 9369
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
@@ -132,14 +132,17 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 4715 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 4282 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 4202 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 3690 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 3376 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 2576 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 1472 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 39 -
|
||||
# 1 Vendor (0xff) Completed without error 00% 5942 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 5370 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 5149 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 4717 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 4282 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 4202 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 3690 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 3376 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 2576 -
|
||||
#10 Vendor (0xff) Completed without error 00% 1472 -
|
||||
#11 Vendor (0xff) Completed without error 00% 39 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -156,7 +159,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/32 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/35 Celsius
|
||||
Lifetime Min/Max Temperature: 14/39 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -165,22 +168,22 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (179)
|
||||
Temperature History Size (Index): 478 (256)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 30 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 4716 --- Power-on Hours
|
||||
0x01 0x018 6 6107363228 --- Logical Sectors Written
|
||||
0x01 0x020 6 212389652 --- Number of Write Commands
|
||||
0x01 0x028 6 533070434 --- Logical Sectors Read
|
||||
0x01 0x030 6 29316041 --- Number of Read Commands
|
||||
0x01 0x008 4 44 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 5942 --- Power-on Hours
|
||||
0x01 0x018 6 7835109003 --- Logical Sectors Written
|
||||
0x01 0x020 6 262708609 --- Number of Write Commands
|
||||
0x01 0x028 6 1587293303 --- Logical Sectors Read
|
||||
0x01 0x030 6 57042625 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 47 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 81 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 29 --- Current Temperature
|
||||
0x05 0x010 1 24 --- Average Short Term Temperature
|
||||
@@ -196,8 +199,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 216 --- Number of Hardware Resets
|
||||
0x06 0x010 4 102 --- Number of ASR Events
|
||||
0x06 0x008 4 318 --- Number of Hardware Resets
|
||||
0x06 0x010 4 146 --- Number of ASR Events
|
||||
0x06 0x018 4 1 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 N-- Percentage Used Endurance Indicator
|
||||
@@ -210,5 +213,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 7 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 14 21:02:06 2022 UTC
|
||||
Local Time is: Sun May 15 20:52:06 2022 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -30,14 +30,14 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x03) Offline data collection activity
|
||||
is in progress.
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 198) seconds.
|
||||
data collection: ( 1115) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
@@ -67,7 +67,7 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 2
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 1
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 1300
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 1323
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 6
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 1
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
@@ -76,16 +76,16 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 067 054 000 - 33 (Min/Max 23/46)
|
||||
194 Temperature_Celsius -O---K 072 054 000 - 28 (Min/Max 23/46)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 1
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 085 085 001 - 15
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 1
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 109143028606
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 3410719905
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 4954797075
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 109341219356
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 3416913378
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 4955528210
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2452
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 4
|
||||
||||||_ K auto-keep
|
||||
@@ -132,7 +132,7 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 1299 -
|
||||
# 1 Vendor (0xff) Completed without error 00% 1314 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 1103 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 960 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 818 -
|
||||
@@ -145,7 +145,7 @@ Num Test_Description Status Remaining LifeTime(hours) LBA
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
2 0 0 Completed [00% left] (11670-77205)
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
@@ -155,8 +155,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 33 Celsius
|
||||
Device State: Active (0)
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/40 Celsius
|
||||
Lifetime Min/Max Temperature: 23/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -166,7 +166,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (318)
|
||||
Temperature History Size (Index): 478 (324)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -174,16 +174,16 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 6 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1300 --- Power-on Hours
|
||||
0x01 0x018 6 109143028606 --- Logical Sectors Written
|
||||
0x01 0x020 6 190976231 --- Number of Write Commands
|
||||
0x01 0x028 6 80600917668 --- Logical Sectors Read
|
||||
0x01 0x030 6 156903548 --- Number of Read Commands
|
||||
0x01 0x010 4 1323 --- Power-on Hours
|
||||
0x01 0x018 6 109341219356 --- Logical Sectors Written
|
||||
0x01 0x020 6 192978543 --- Number of Write Commands
|
||||
0x01 0x028 6 80604678766 --- Logical Sectors Read
|
||||
0x01 0x030 6 157051579 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 11 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x008 1 28 --- Current Temperature
|
||||
0x05 0x010 1 32 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 46 --- Highest Temperature
|
||||
@@ -197,8 +197,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 331 --- Number of Hardware Resets
|
||||
0x06 0x010 4 106 --- Number of ASR Events
|
||||
0x06 0x008 4 349 --- Number of Hardware Resets
|
||||
0x06 0x010 4 112 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 15 N-- Percentage Used Endurance Indicator
|
||||
@@ -211,5 +211,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 285 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 303 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Jul 13 10:52:57 2022 UTC
|
||||
Local Time is: Sun Jul 17 20:12:21 2022 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -30,14 +30,14 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Offline data collection status: (0x04) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 1357) seconds.
|
||||
data collection: ( 92) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
@@ -55,7 +55,7 @@ Error logging capability: (0x01) Error logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 7) minutes.
|
||||
recommended polling time: ( 6) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
@@ -67,7 +67,7 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 2
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 1
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 40692
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 40797
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 18
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 1
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
@@ -76,16 +76,16 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 066 044 000 - 34 (Min/Max 18/56)
|
||||
194 Temperature_Celsius -O---K 063 044 000 - 37 (Min/Max 18/56)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 1
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 021 021 001 - 79
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 1
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 506397052595
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 15938122746
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 99148140301
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 506748293464
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 15949099080
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 99148852538
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2467
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 4
|
||||
||||||_ K auto-keep
|
||||
@@ -132,25 +132,25 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 40691 -
|
||||
# 2 Extended offline Completed without error 00% 40678 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 40678 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 40334 -
|
||||
# 5 Extended offline Completed without error 00% 40216 -
|
||||
# 6 Extended offline Completed without error 00% 40204 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 32797 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 32736 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 27920 -
|
||||
#10 Vendor (0xff) Completed without error 00% 26827 -
|
||||
#11 Vendor (0xff) Completed without error 00% 24329 -
|
||||
#12 Vendor (0xff) Completed without error 00% 22077 -
|
||||
#13 Vendor (0xff) Completed without error 00% 20750 -
|
||||
#14 Vendor (0xff) Completed without error 00% 19509 -
|
||||
#15 Vendor (0xff) Completed without error 00% 18245 -
|
||||
#16 Vendor (0xff) Completed without error 00% 16952 -
|
||||
#17 Vendor (0xff) Completed without error 00% 15354 -
|
||||
#18 Vendor (0xff) Completed without error 00% 13939 -
|
||||
#19 Vendor (0xff) Completed without error 00% 12324 -
|
||||
# 1 Vendor (0xff) Completed without error 00% 40796 -
|
||||
# 2 Extended offline Completed without error 00% 40691 -
|
||||
# 3 Extended offline Completed without error 00% 40678 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 40678 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 40334 -
|
||||
# 6 Extended offline Completed without error 00% 40216 -
|
||||
# 7 Extended offline Completed without error 00% 40204 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 32797 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 32736 -
|
||||
#10 Vendor (0xff) Completed without error 00% 27920 -
|
||||
#11 Vendor (0xff) Completed without error 00% 26827 -
|
||||
#12 Vendor (0xff) Completed without error 00% 24329 -
|
||||
#13 Vendor (0xff) Completed without error 00% 22077 -
|
||||
#14 Vendor (0xff) Completed without error 00% 20750 -
|
||||
#15 Vendor (0xff) Completed without error 00% 19509 -
|
||||
#16 Vendor (0xff) Completed without error 00% 18245 -
|
||||
#17 Vendor (0xff) Completed without error 00% 16952 -
|
||||
#18 Vendor (0xff) Completed without error 00% 15354 -
|
||||
#19 Vendor (0xff) Completed without error 00% 13939 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -165,9 +165,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/35 Celsius
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/39 Celsius
|
||||
Lifetime Min/Max Temperature: 18/56 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -176,7 +176,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (83)
|
||||
Temperature History Size (Index): 478 (448)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -184,17 +184,17 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 18 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 40692 --- Power-on Hours
|
||||
0x01 0x018 6 506397052595 --- Logical Sectors Written
|
||||
0x01 0x020 6 11804301492 --- Number of Write Commands
|
||||
0x01 0x028 6 478040337066 --- Logical Sectors Read
|
||||
0x01 0x030 6 10435827862 --- Number of Read Commands
|
||||
0x01 0x010 4 40797 --- Power-on Hours
|
||||
0x01 0x018 6 506748293464 --- Logical Sectors Written
|
||||
0x01 0x020 6 11809522237 --- Number of Write Commands
|
||||
0x01 0x028 6 478051403750 --- Logical Sectors Read
|
||||
0x01 0x030 6 10436190339 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 24 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 34 --- Current Temperature
|
||||
0x05 0x010 1 29 --- Average Short Term Temperature
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x010 1 32 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 56 --- Highest Temperature
|
||||
0x05 0x028 1 18 --- Lowest Temperature
|
||||
@@ -207,8 +207,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 169 --- Number of Hardware Resets
|
||||
0x06 0x010 4 47 --- Number of ASR Events
|
||||
0x06 0x008 4 305 --- Number of Hardware Resets
|
||||
0x06 0x010 4 93 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 79 N-- Percentage Used Endurance Indicator
|
||||
@@ -221,7 +221,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 151 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Jul 13 10:52:57 2022 UTC
|
||||
Local Time is: Sun Jul 17 20:12:21 2022 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -30,14 +30,14 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Offline data collection status: (0x04) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 1357) seconds.
|
||||
data collection: ( 89) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
@@ -55,7 +55,7 @@ Error logging capability: (0x01) Error logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 7) minutes.
|
||||
recommended polling time: ( 6) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
@@ -67,7 +67,7 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 40691
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 40797
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 18
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
@@ -76,16 +76,16 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 066 045 000 - 34 (Min/Max 18/55)
|
||||
194 Temperature_Celsius -O---K 063 045 000 - 37 (Min/Max 18/55)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 020 020 001 - 80
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 506900081522
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 15953842396
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 100239685800
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 507238359091
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 15964413615
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 100242854534
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2459
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
@@ -132,25 +132,25 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 40691 -
|
||||
# 2 Extended offline Completed without error 00% 40678 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 40678 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 40333 -
|
||||
# 5 Extended offline Completed without error 00% 40216 -
|
||||
# 6 Extended offline Completed without error 00% 40204 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 32701 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 32619 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 27916 -
|
||||
#10 Vendor (0xff) Completed without error 00% 26553 -
|
||||
#11 Vendor (0xff) Completed without error 00% 23696 -
|
||||
#12 Vendor (0xff) Completed without error 00% 21990 -
|
||||
#13 Vendor (0xff) Completed without error 00% 20721 -
|
||||
#14 Vendor (0xff) Completed without error 00% 19515 -
|
||||
#15 Vendor (0xff) Completed without error 00% 18260 -
|
||||
#16 Vendor (0xff) Completed without error 00% 16978 -
|
||||
#17 Vendor (0xff) Completed without error 00% 15468 -
|
||||
#18 Vendor (0xff) Completed without error 00% 14112 -
|
||||
#19 Vendor (0xff) Completed without error 00% 12669 -
|
||||
# 1 Vendor (0xff) Completed without error 00% 40797 -
|
||||
# 2 Extended offline Completed without error 00% 40691 -
|
||||
# 3 Extended offline Completed without error 00% 40678 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 40678 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 40333 -
|
||||
# 6 Extended offline Completed without error 00% 40216 -
|
||||
# 7 Extended offline Completed without error 00% 40204 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 32701 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 32619 -
|
||||
#10 Vendor (0xff) Completed without error 00% 27916 -
|
||||
#11 Vendor (0xff) Completed without error 00% 26553 -
|
||||
#12 Vendor (0xff) Completed without error 00% 23696 -
|
||||
#13 Vendor (0xff) Completed without error 00% 21990 -
|
||||
#14 Vendor (0xff) Completed without error 00% 20721 -
|
||||
#15 Vendor (0xff) Completed without error 00% 19515 -
|
||||
#16 Vendor (0xff) Completed without error 00% 18260 -
|
||||
#17 Vendor (0xff) Completed without error 00% 16978 -
|
||||
#18 Vendor (0xff) Completed without error 00% 15468 -
|
||||
#19 Vendor (0xff) Completed without error 00% 14112 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -165,9 +165,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/34 Celsius
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/39 Celsius
|
||||
Lifetime Min/Max Temperature: 18/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -176,7 +176,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (372)
|
||||
Temperature History Size (Index): 478 (139)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -184,16 +184,16 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 18 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 40691 --- Power-on Hours
|
||||
0x01 0x018 6 506900081522 --- Logical Sectors Written
|
||||
0x01 0x020 6 11790825275 --- Number of Write Commands
|
||||
0x01 0x028 6 166244592064 --- Logical Sectors Read
|
||||
0x01 0x030 6 3615106507 --- Number of Read Commands
|
||||
0x01 0x010 4 40797 --- Power-on Hours
|
||||
0x01 0x018 6 507238359091 --- Logical Sectors Written
|
||||
0x01 0x020 6 11795903297 --- Number of Write Commands
|
||||
0x01 0x028 6 166252442754 --- Logical Sectors Read
|
||||
0x01 0x030 6 3615348241 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 26 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 34 --- Current Temperature
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x010 1 35 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 55 --- Highest Temperature
|
||||
@@ -207,8 +207,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 167 --- Number of Hardware Resets
|
||||
0x06 0x010 4 47 --- Number of ASR Events
|
||||
0x06 0x008 4 303 --- Number of Hardware Resets
|
||||
0x06 0x010 4 93 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 80 N-- Percentage Used Endurance Indicator
|
||||
@@ -221,5 +221,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 151 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 14 21:02:05 2022 UTC
|
||||
Local Time is: Sun May 15 20:52:06 2022 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -30,14 +30,14 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x03) Offline data collection activity
|
||||
is in progress.
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 202) seconds.
|
||||
data collection: ( 1087) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
@@ -67,7 +67,7 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 1422
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 1446
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 9
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
@@ -76,16 +76,16 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 1
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 064 050 000 - 36 (Min/Max 23/50)
|
||||
194 Temperature_Celsius -O---K 070 050 000 - 30 (Min/Max 23/50)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 085 085 001 - 15
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 109439248461
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 3419976781
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 4933945684
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 109644915931
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 3426403902
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 4934419287
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2466
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
@@ -132,7 +132,7 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 1422 -
|
||||
# 1 Vendor (0xff) Completed without error 00% 1437 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 1227 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 1083 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 937 -
|
||||
@@ -149,7 +149,7 @@ Num Test_Description Status Remaining LifeTime(hours) LBA
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
2 0 0 Completed [00% left] (12884-78419)
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
@@ -159,8 +159,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 36 Celsius
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/46 Celsius
|
||||
Lifetime Min/Max Temperature: 23/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -170,7 +170,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (39)
|
||||
Temperature History Size (Index): 478 (45)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -178,16 +178,16 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 9 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1422 --- Power-on Hours
|
||||
0x01 0x018 6 109439248461 --- Logical Sectors Written
|
||||
0x01 0x020 6 193885926 --- Number of Write Commands
|
||||
0x01 0x028 6 81264748347 --- Logical Sectors Read
|
||||
0x01 0x030 6 156371387 --- Number of Read Commands
|
||||
0x01 0x010 4 1446 --- Power-on Hours
|
||||
0x01 0x018 6 109644915931 --- Logical Sectors Written
|
||||
0x01 0x020 6 195964578 --- Number of Write Commands
|
||||
0x01 0x028 6 81268483633 --- Logical Sectors Read
|
||||
0x01 0x030 6 156524731 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 14 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 36 --- Current Temperature
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x010 1 28 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 50 --- Highest Temperature
|
||||
@@ -201,8 +201,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 368 --- Number of Hardware Resets
|
||||
0x06 0x010 4 106 --- Number of ASR Events
|
||||
0x06 0x008 4 386 --- Number of Hardware Resets
|
||||
0x06 0x010 4 112 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 15 N-- Percentage Used Endurance Indicator
|
||||
@@ -215,7 +215,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 285 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 303 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: < 1.8 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Nov 3 19:24:17 2020 CET
|
||||
Local Time is: Sun Dec 20 22:55:15 2020 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,25 +66,25 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 092 091 000 - 12
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 7
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 3461
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 6045
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 3480
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 6086
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 093 093 000 - 109
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 526
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 528
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 054 025 000 - 46 (Min/Max 7/75)
|
||||
194 Temperature_Celsius -O---K 037 025 000 - 63 (Min/Max 7/75)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 7
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 1
|
||||
202 Percent_Lifetime_Remain ----CK 093 093 001 - 7
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 24390533689
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 828765583
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 436570105
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 24505293634
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 833021199
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 440840534
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2035
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 30
|
||||
||||||_ K auto-keep
|
||||
@@ -146,8 +146,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 46 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/48 Celsius
|
||||
Current Temperature: 63 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/63 Celsius
|
||||
Lifetime Min/Max Temperature: 7/75 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -156,24 +156,24 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (147)
|
||||
Temperature History Size (Index): 478 (418)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 6045 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3461 --- Power-on Hours
|
||||
0x01 0x018 6 24390533689 --- Logical Sectors Written
|
||||
0x01 0x020 6 598144388 --- Number of Write Commands
|
||||
0x01 0x028 6 27993495739 --- Logical Sectors Read
|
||||
0x01 0x030 6 629982447 --- Number of Read Commands
|
||||
0x01 0x008 4 6086 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3480 --- Power-on Hours
|
||||
0x01 0x018 6 24505293634 --- Logical Sectors Written
|
||||
0x01 0x020 6 602176409 --- Number of Write Commands
|
||||
0x01 0x028 6 28055593148 --- Logical Sectors Read
|
||||
0x01 0x030 6 631626865 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 6050 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 6090 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 46 --- Current Temperature
|
||||
0x05 0x008 1 63 --- Current Temperature
|
||||
0x05 0x010 1 48 --- Average Short Term Temperature
|
||||
0x05 0x018 1 48 --- Average Long Term Temperature
|
||||
0x05 0x020 1 75 --- Highest Temperature
|
||||
@@ -187,8 +187,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 18410 --- Number of Hardware Resets
|
||||
0x06 0x010 4 4904 --- Number of ASR Events
|
||||
0x06 0x008 4 18500 --- Number of Hardware Resets
|
||||
0x06 0x010 4 4914 --- Number of ASR Events
|
||||
0x06 0x018 4 1 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 7 N-- Percentage Used Endurance Indicator
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jul 10 08:44:58 2021 EDT
|
||||
Local Time is: Thu Jul 29 21:31:49 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -37,7 +37,7 @@ Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 617) seconds.
|
||||
data collection: ( 745) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
@@ -55,7 +55,7 @@ Error logging capability: (0x01) Error logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 4) minutes.
|
||||
recommended polling time: ( 5) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
@@ -67,25 +67,25 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 16570
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 6
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 17037
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 8
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 098 098 000 - 33
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 4
|
||||
173 Ave_Block-Erase_Count -O--CK 098 098 000 - 34
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 6
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 056 038 000 - 44 (Min/Max 15/62)
|
||||
194 Temperature_Celsius -O---K 057 038 000 - 43 (Min/Max 15/62)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 098 098 001 - 2
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 9070651086
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 284551518
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 51568050
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 9346661518
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 293176840
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 52951592
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2043
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
@@ -132,30 +132,30 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 16510 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 5460 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 5312 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 5158 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 16093 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 15917 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 15731 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 15551 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 15355 -
|
||||
#10 Vendor (0xff) Completed without error 00% 15157 -
|
||||
#11 Vendor (0xff) Completed without error 00% 14963 -
|
||||
#12 Vendor (0xff) Completed without error 00% 14750 -
|
||||
#13 Vendor (0xff) Completed without error 00% 14604 -
|
||||
#14 Vendor (0xff) Completed without error 00% 14407 -
|
||||
#15 Vendor (0xff) Completed without error 00% 14195 -
|
||||
#16 Vendor (0xff) Completed without error 00% 13991 -
|
||||
#17 Vendor (0xff) Completed without error 00% 13869 -
|
||||
#18 Vendor (0xff) Completed without error 00% 13749 -
|
||||
#19 Vendor (0xff) Completed without error 00% 13633 -
|
||||
# 1 Vendor (0xff) Completed without error 00% 16994 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 16873 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 6183 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 6047 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 5895 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 5754 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 16510 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 5460 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 5312 -
|
||||
#10 Vendor (0xff) Completed without error 00% 5158 -
|
||||
#11 Vendor (0xff) Completed without error 00% 16093 -
|
||||
#12 Vendor (0xff) Completed without error 00% 15917 -
|
||||
#13 Vendor (0xff) Completed without error 00% 15731 -
|
||||
#14 Vendor (0xff) Completed without error 00% 15551 -
|
||||
#15 Vendor (0xff) Completed without error 00% 15355 -
|
||||
#16 Vendor (0xff) Completed without error 00% 15157 -
|
||||
#17 Vendor (0xff) Completed without error 00% 14963 -
|
||||
#18 Vendor (0xff) Completed without error 00% 14750 -
|
||||
#19 Vendor (0xff) Completed without error 00% 14604 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Completed [00% left] (12974-78509)
|
||||
2 0 0 Completed [00% left] (73822-139357)
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
@@ -166,8 +166,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 44 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/55 Celsius
|
||||
Current Temperature: 43 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/53 Celsius
|
||||
Lifetime Min/Max Temperature: 15/62 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -176,30 +176,30 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (124)
|
||||
Temperature History Size (Index): 478 (228)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 6 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 16570 --- Power-on Hours
|
||||
0x01 0x018 6 9070651086 --- Logical Sectors Written
|
||||
0x01 0x020 6 145163160 --- Number of Write Commands
|
||||
0x01 0x028 6 40621527 --- Logical Sectors Read
|
||||
0x01 0x030 6 1020787 --- Number of Read Commands
|
||||
0x01 0x008 4 8 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 17037 --- Power-on Hours
|
||||
0x01 0x018 6 9346661518 --- Logical Sectors Written
|
||||
0x01 0x020 6 149260916 --- Number of Write Commands
|
||||
0x01 0x028 6 47315968 --- Logical Sectors Read
|
||||
0x01 0x030 6 1224287 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 6 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 8 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 44 --- Current Temperature
|
||||
0x05 0x010 1 44 --- Average Short Term Temperature
|
||||
0x05 0x008 1 43 --- Current Temperature
|
||||
0x05 0x010 1 43 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 62 --- Highest Temperature
|
||||
0x05 0x028 1 15 --- Lowest Temperature
|
||||
0x05 0x030 1 53 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 44 --- Lowest Average Short Term Temperature
|
||||
0x05 0x038 1 43 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
@@ -207,8 +207,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 179 --- Number of Hardware Resets
|
||||
0x06 0x010 4 76 --- Number of ASR Events
|
||||
0x06 0x008 4 196 --- Number of Hardware Resets
|
||||
0x06 0x010 4 81 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 2 N-- Percentage Used Endurance Indicator
|
||||
@@ -221,5 +221,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 32 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 13 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p11-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p20-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Feb 2 08:41:01 2021 CET
|
||||
Local Time is: Sun Oct 24 19:49:04 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -27,17 +27,19 @@ ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
SMART overall-health self-assessment test result: FAILED!
|
||||
Drive failure expected in less than 24 hours. SAVE ALL DATA.
|
||||
No failed Attributes found.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x04) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Offline data collection status: (0x06) Offline data collection activity
|
||||
was aborted by the device with a fatal error.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 240) seconds.
|
||||
data collection: ( 678) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
@@ -55,7 +57,7 @@ Error logging capability: (0x01) Error logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 7) minutes.
|
||||
recommended polling time: ( 4) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
@@ -65,28 +67,28 @@ SCT capabilities: (0x0035) SCT Status supported.
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 19266
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 33
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 786
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 088 088 010 - 241
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 25611
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 34
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 043 043 000 - 859
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 25
|
||||
173 Ave_Block-Erase_Count -O--CK 001 001 000 - 7372
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 26
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 052 043 000 - 48 (Min/Max 17/57)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 052 037 000 - 48 (Min/Max 17/63)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 241
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 043 043 001 - 57
|
||||
202 Percent_Lifetime_Remain ----CK 000 000 001 NOW 100
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 237463565208
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 7420959629
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 1294393961
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2048
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 3094383313136
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 96699701752
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 33055886277
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1807
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -132,25 +134,25 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 19263 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 18883 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 18402 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 17899 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 17452 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 17004 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 16408 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 15962 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 15601 -
|
||||
#10 Vendor (0xff) Completed without error 00% 15052 -
|
||||
#11 Vendor (0xff) Completed without error 00% 14543 -
|
||||
#12 Vendor (0xff) Completed without error 00% 13995 -
|
||||
#13 Vendor (0xff) Completed without error 00% 3272 -
|
||||
#14 Vendor (0xff) Completed without error 00% 3061 -
|
||||
#15 Vendor (0xff) Completed without error 00% 2841 -
|
||||
#16 Vendor (0xff) Completed without error 00% 2628 -
|
||||
#17 Vendor (0xff) Completed without error 00% 2420 -
|
||||
#18 Vendor (0xff) Completed without error 00% 2234 -
|
||||
#19 Vendor (0xff) Completed without error 00% 2034 -
|
||||
# 1 Vendor (0xff) Completed without error 00% 22055 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 20144 -
|
||||
# 3 Short offline Self-test routine in progress 90% 20063 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 19928 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 19852 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 19341 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 18883 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 18402 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 17899 -
|
||||
#10 Vendor (0xff) Completed without error 00% 17452 -
|
||||
#11 Vendor (0xff) Completed without error 00% 17004 -
|
||||
#12 Vendor (0xff) Completed without error 00% 16408 -
|
||||
#13 Vendor (0xff) Completed without error 00% 15962 -
|
||||
#14 Vendor (0xff) Completed without error 00% 15601 -
|
||||
#15 Vendor (0xff) Completed without error 00% 15052 -
|
||||
#16 Vendor (0xff) Completed without error 00% 14543 -
|
||||
#17 Vendor (0xff) Completed without error 00% 13995 -
|
||||
#18 Vendor (0xff) Completed without error 00% 3272 -
|
||||
#19 Vendor (0xff) Completed without error 00% 3061 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -167,8 +169,8 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 48 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/56 Celsius
|
||||
Lifetime Min/Max Temperature: 17/57 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/63 Celsius
|
||||
Lifetime Min/Max Temperature: 17/63 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -176,27 +178,27 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (388)
|
||||
Temperature History Size (Index): 478 (378)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 33 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 19266 --- Power-on Hours
|
||||
0x01 0x018 6 237463565208 --- Logical Sectors Written
|
||||
0x01 0x020 6 3411397661 --- Number of Write Commands
|
||||
0x01 0x028 6 4581310790 --- Logical Sectors Read
|
||||
0x01 0x030 6 151739990 --- Number of Read Commands
|
||||
0x01 0x008 4 34 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 25611 --- Power-on Hours
|
||||
0x01 0x018 6 3094383313136 --- Logical Sectors Written
|
||||
0x01 0x020 6 42686156664 --- Number of Write Commands
|
||||
0x01 0x028 6 129647936382 --- Logical Sectors Read
|
||||
0x01 0x030 6 1388712629 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 29 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 30 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 48 --- Current Temperature
|
||||
0x05 0x010 1 44 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 57 --- Highest Temperature
|
||||
0x05 0x020 1 63 --- Highest Temperature
|
||||
0x05 0x028 1 17 --- Lowest Temperature
|
||||
0x05 0x030 1 44 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 35 --- Lowest Average Short Term Temperature
|
||||
@@ -207,11 +209,11 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 258 --- Number of Hardware Resets
|
||||
0x06 0x010 4 81 --- Number of ASR Events
|
||||
0x06 0x008 4 315 --- Number of Hardware Resets
|
||||
0x06 0x010 4 105 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 57 N-- Percentage Used Endurance Indicator
|
||||
0x07 0x008 1 235 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
@@ -221,5 +223,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 80 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 25 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-RELEASE-p7 amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Feb 6 17:45:03 2022 NZDT
|
||||
Local Time is: Wed Apr 13 05:57:30 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -67,25 +67,25 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 2736
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 5514
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 3186
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 5578
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 094 094 000 - 104
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 26
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 29
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 059 042 000 - 41 (Min/Max 8/58)
|
||||
194 Temperature_Celsius -O---K 064 042 000 - 36 (Min/Max 8/58)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 094 094 001 - 6
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 26967137165
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 845090884
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 233149140
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 26975709037
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 845361648
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 233204172
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2043
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
@@ -132,19 +132,23 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 2616 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 2515 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 2447 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 2408 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 2279 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 2196 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 2101 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 1964 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 1895 -
|
||||
#10 Vendor (0xff) Completed without error 00% 1816 -
|
||||
#11 Vendor (0xff) Completed without error 00% 1739 -
|
||||
#12 Vendor (0xff) Completed without error 00% 1645 -
|
||||
#13 Vendor (0xff) Completed without error 00% 1502 -
|
||||
# 1 Vendor (0xff) Completed without error 00% 3143 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 3053 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 2996 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 2741 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 2616 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 2515 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 2447 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 2408 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 2279 -
|
||||
#10 Vendor (0xff) Completed without error 00% 2196 -
|
||||
#11 Vendor (0xff) Completed without error 00% 2101 -
|
||||
#12 Vendor (0xff) Completed without error 00% 1964 -
|
||||
#13 Vendor (0xff) Completed without error 00% 1895 -
|
||||
#14 Vendor (0xff) Completed without error 00% 1816 -
|
||||
#15 Vendor (0xff) Completed without error 00% 1739 -
|
||||
#16 Vendor (0xff) Completed without error 00% 1645 -
|
||||
#17 Vendor (0xff) Completed without error 00% 1502 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -160,8 +164,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/53 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/46 Celsius
|
||||
Lifetime Min/Max Temperature: 8/58 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -170,39 +174,39 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (289)
|
||||
Temperature History Size (Index): 478 (310)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 5514 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2736 --- Power-on Hours
|
||||
0x01 0x018 6 26967137165 --- Logical Sectors Written
|
||||
0x01 0x020 6 459904172 --- Number of Write Commands
|
||||
0x01 0x028 6 33258428245 --- Logical Sectors Read
|
||||
0x01 0x030 6 617557382 --- Number of Read Commands
|
||||
0x01 0x008 4 5578 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3186 --- Power-on Hours
|
||||
0x01 0x018 6 26975709037 --- Logical Sectors Written
|
||||
0x01 0x020 6 460163191 --- Number of Write Commands
|
||||
0x01 0x028 6 33274502990 --- Logical Sectors Read
|
||||
0x01 0x030 6 617910963 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 5540 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 5614 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 41 --- Current Temperature
|
||||
0x05 0x010 1 37 --- Average Short Term Temperature
|
||||
0x05 0x018 1 44 --- Average Long Term Temperature
|
||||
0x05 0x008 1 36 --- Current Temperature
|
||||
0x05 0x010 1 38 --- Average Short Term Temperature
|
||||
0x05 0x018 1 37 --- Average Long Term Temperature
|
||||
0x05 0x020 1 58 --- Highest Temperature
|
||||
0x05 0x028 1 8 --- Lowest Temperature
|
||||
0x05 0x030 1 48 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 32 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 44 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 44 --- Lowest Average Long Term Temperature
|
||||
0x05 0x048 1 37 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 41181 --- Number of Hardware Resets
|
||||
0x06 0x010 4 131 --- Number of ASR Events
|
||||
0x06 0x008 4 41621 --- Number of Hardware Resets
|
||||
0x06 0x010 4 177 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 6 N-- Percentage Used Endurance Indicator
|
||||
@@ -215,7 +219,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 46 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jan 10 23:08:36 2023 CET
|
||||
Local Time is: Thu Jan 26 21:35:02 2023 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -67,8 +67,8 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct -O--CK 100 100 001 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 370
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 166
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 752
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 170
|
||||
170 Reserved_Block_Pct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 001 - 0
|
||||
@@ -77,8 +77,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
183 SATA_Int_Downshift_Ct -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 12
|
||||
194 Temperature_Celsius -O---K 052 045 000 - 48 (Min/Max 17/55)
|
||||
188 Command_Timeout -O--CK 100 100 000 - 16
|
||||
194 Temperature_Celsius -O---K 055 045 000 - 45 (Min/Max 17/55)
|
||||
195 Hardware_ECC_Recovered -O--CK 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
@@ -86,12 +86,12 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 100 100 001 - 0
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 459094658
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 14381337
|
||||
248 Bckgnd_Program_Page_Cnt -O--CK 100 100 000 - 1371476
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 701508707
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 21984715
|
||||
248 Bckgnd_Program_Page_Cnt -O--CK 100 100 000 - 2024597
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot PO--CK 000 000 000 - 9898
|
||||
210 RAIN_Success_Recovered -O--CK 100 100 000 - 0
|
||||
211 Integ_Scan_Complete_Cnt -O--CK 100 100 000 - 55
|
||||
211 Integ_Scan_Complete_Cnt -O--CK 100 100 000 - 62
|
||||
212 Integ_Scan_Folding_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -135,10 +135,11 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 15 -
|
||||
# 2 Short offline Completed without error 00% 14 -
|
||||
# 3 Short offline Completed without error 00% 0 -
|
||||
# 1 Vendor (0xff) Completed without error 00% 656 -
|
||||
# 2 Extended offline Completed without error 00% 15 -
|
||||
# 3 Short offline Completed without error 00% 14 -
|
||||
# 4 Short offline Completed without error 00% 0 -
|
||||
# 5 Short offline Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -154,8 +155,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 48 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/50 Celsius
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/45 Celsius
|
||||
Lifetime Min/Max Temperature: 17/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -164,31 +165,31 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (83)
|
||||
Temperature History Size (Index): 478 (32)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 166 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 370 --- Power-on Hours
|
||||
0x01 0x018 6 459094658 --- Logical Sectors Written
|
||||
0x01 0x020 6 7554383 --- Number of Write Commands
|
||||
0x01 0x028 6 22266601368 --- Logical Sectors Read
|
||||
0x01 0x030 6 18383221 --- Number of Read Commands
|
||||
0x01 0x038 6 1334400000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 170 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 752 --- Power-on Hours
|
||||
0x01 0x018 6 701508707 --- Logical Sectors Written
|
||||
0x01 0x020 6 11167400 --- Number of Write Commands
|
||||
0x01 0x028 6 22273247272 --- Logical Sectors Read
|
||||
0x01 0x030 6 18552687 --- Number of Read Commands
|
||||
0x01 0x038 6 2708640000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 12 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 16 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 48 --- Current Temperature
|
||||
0x05 0x010 1 48 --- Average Short Term Temperature
|
||||
0x05 0x008 1 45 --- Current Temperature
|
||||
0x05 0x010 1 37 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 55 --- Highest Temperature
|
||||
0x05 0x028 1 17 --- Lowest Temperature
|
||||
0x05 0x030 1 50 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 38 --- Lowest Average Short Term Temperature
|
||||
0x05 0x030 1 54 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 37 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
@@ -196,8 +197,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 468 --- Number of Hardware Resets
|
||||
0x06 0x010 4 127 --- Number of ASR Events
|
||||
0x06 0x008 4 492 --- Number of Hardware Resets
|
||||
0x06 0x010 4 131 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 N-- Percentage Used Endurance Indicator
|
||||
@@ -213,7 +214,7 @@ ID Size Value Description
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x000a 4 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Apr 20 02:28:46 2022 WIB
|
||||
Local Time is: Thu Apr 21 13:07:51 2022 WIB
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -67,18 +67,18 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct -O--CK 100 100 001 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 293
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 35
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 328
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 36
|
||||
170 Reserved_Block_Pct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 001 - 0
|
||||
173 Avg_Block-Erase_Count -O--CK 100 100 000 - 1
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 23
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 24
|
||||
183 SATA_Int_Downshift_Ct -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 29
|
||||
194 Temperature_Celsius -O---K 065 043 000 - 35 (Min/Max 21/57)
|
||||
188 Command_Timeout -O--CK 100 100 000 - 30
|
||||
194 Temperature_Celsius -O---K 064 043 000 - 36 (Min/Max 21/57)
|
||||
195 Hardware_ECC_Recovered -O--CK 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
@@ -86,12 +86,12 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 100 100 001 - 0
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 924370786
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 28886679
|
||||
248 Bckgnd_Program_Page_Cnt -O--CK 100 100 000 - 1265383
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 924370798
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 28886680
|
||||
248 Bckgnd_Program_Page_Cnt -O--CK 100 100 000 - 1271596
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot PO--CK 100 100 000 - 2161
|
||||
210 RAIN_Success_Recovered -O--CK 100 100 000 - 0
|
||||
211 Integ_Scan_Complete_Cnt -O--CK 100 100 000 - 34
|
||||
211 Integ_Scan_Complete_Cnt -O--CK 100 100 000 - 35
|
||||
212 Integ_Scan_Folding_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -150,8 +150,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/37 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/37 Celsius
|
||||
Lifetime Min/Max Temperature: 21/57 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -162,31 +162,31 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (449)
|
||||
Temperature History Size (Index): 478 (126)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 3) ==
|
||||
0x01 0x008 4 35 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 293 --- Power-on Hours
|
||||
0x01 0x018 6 924370786 --- Logical Sectors Written
|
||||
0x01 0x020 6 478173 --- Number of Write Commands
|
||||
0x01 0x028 6 2415522 --- Logical Sectors Read
|
||||
0x01 0x030 6 298958 --- Number of Read Commands
|
||||
0x01 0x038 6 1057620000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 36 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 328 --- Power-on Hours
|
||||
0x01 0x018 6 924370798 --- Logical Sectors Written
|
||||
0x01 0x020 6 478179 --- Number of Write Commands
|
||||
0x01 0x028 6 2416023 --- Logical Sectors Read
|
||||
0x01 0x030 6 299069 --- Number of Read Commands
|
||||
0x01 0x038 6 1181760000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 29 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 30 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 35 --- Current Temperature
|
||||
0x05 0x010 1 46 --- Average Short Term Temperature
|
||||
0x05 0x008 1 36 --- Current Temperature
|
||||
0x05 0x010 1 35 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 57 --- Highest Temperature
|
||||
0x05 0x028 1 21 --- Lowest Temperature
|
||||
0x05 0x030 1 54 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 37 --- Lowest Average Short Term Temperature
|
||||
0x05 0x038 1 35 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
@@ -194,8 +194,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 234 --- Number of Hardware Resets
|
||||
0x06 0x010 4 84 --- Number of ASR Events
|
||||
0x06 0x008 4 247 --- Number of Hardware Resets
|
||||
0x06 0x010 4 88 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
@@ -211,7 +211,7 @@ ID Size Value Description
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x000a 4 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 13 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Apr 20 02:28:46 2022 WIB
|
||||
Local Time is: Thu Apr 21 13:07:51 2022 WIB
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -67,17 +67,17 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct -O--CK 100 100 001 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 293
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 35
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 328
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 36
|
||||
170 Reserved_Block_Pct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 001 - 0
|
||||
173 Avg_Block-Erase_Count -O--CK 100 100 000 - 1
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 23
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 24
|
||||
183 SATA_Int_Downshift_Ct -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 29
|
||||
188 Command_Timeout -O--CK 100 100 000 - 30
|
||||
194 Temperature_Celsius -O---K 068 043 000 - 32 (Min/Max 22/57)
|
||||
195 Hardware_ECC_Recovered -O--CK 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
@@ -86,12 +86,12 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 100 100 001 - 0
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 22001210
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 687629
|
||||
248 Bckgnd_Program_Page_Cnt -O--CK 100 100 000 - 85066
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 22001222
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 687631
|
||||
248 Bckgnd_Program_Page_Cnt -O--CK 100 100 000 - 91267
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot PO--CK 100 100 000 - 2161
|
||||
210 RAIN_Success_Recovered -O--CK 100 100 000 - 0
|
||||
211 Integ_Scan_Complete_Cnt -O--CK 100 100 000 - 40
|
||||
211 Integ_Scan_Complete_Cnt -O--CK 100 100 000 - 42
|
||||
212 Integ_Scan_Folding_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -151,7 +151,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/34 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/34 Celsius
|
||||
Lifetime Min/Max Temperature: 22/57 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -162,31 +162,31 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (445)
|
||||
Temperature History Size (Index): 478 (122)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 3) ==
|
||||
0x01 0x008 4 35 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 293 --- Power-on Hours
|
||||
0x01 0x018 6 22001210 --- Logical Sectors Written
|
||||
0x01 0x020 6 16920 --- Number of Write Commands
|
||||
0x01 0x028 6 893219179 --- Logical Sectors Read
|
||||
0x01 0x030 6 660336 --- Number of Read Commands
|
||||
0x01 0x038 6 1057380000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 36 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 328 --- Power-on Hours
|
||||
0x01 0x018 6 22001222 --- Logical Sectors Written
|
||||
0x01 0x020 6 16926 --- Number of Write Commands
|
||||
0x01 0x028 6 893219302 --- Logical Sectors Read
|
||||
0x01 0x030 6 660420 --- Number of Read Commands
|
||||
0x01 0x038 6 1181520000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 29 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 30 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x010 1 42 --- Average Short Term Temperature
|
||||
0x05 0x010 1 32 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 57 --- Highest Temperature
|
||||
0x05 0x028 1 22 --- Lowest Temperature
|
||||
0x05 0x030 1 50 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 34 --- Lowest Average Short Term Temperature
|
||||
0x05 0x038 1 32 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
@@ -194,8 +194,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 234 --- Number of Hardware Resets
|
||||
0x06 0x010 4 84 --- Number of ASR Events
|
||||
0x06 0x008 4 247 --- Number of Hardware Resets
|
||||
0x06 0x010 4 88 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
@@ -211,7 +211,7 @@ ID Size Value Description
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x000a 4 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 13 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic
|
||||
Device is: Not in smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sun Jan 1 12:09:20 2012 CST
|
||||
Local Time is: Wed Aug 24 00:30:53 2022 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,10 +66,10 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 51200 (0 1)
|
||||
12 Power_Cycle_Count PO--CK 100 100 001 - 803
|
||||
12 Power_Cycle_Count PO--CK 100 100 001 - 808
|
||||
175 Program_Fail_Count_Chip PO--CK 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip PO--CK 100 100 000 - 0
|
||||
177 Wear_Leveling_Count PO--CK 092 092 010 - 253
|
||||
177 Wear_Leveling_Count PO--CK 092 092 010 - 256
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--CK 096 096 000 - 6
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--CK 100 100 000 - 57
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot PO--CK 002 002 000 - 8682
|
||||
@@ -77,8 +77,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total PO--CK 100 100 001 - 0
|
||||
187 Reported_Uncorrect PO--CK 100 100 001 - 1973
|
||||
195 Hardware_ECC_Recovered POSR-K 100 100 050 - 6
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 47015401651
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 9994006373
|
||||
241 Total_LBAs_Written PO--CK 100 100 000 - 47725104043
|
||||
242 Total_LBAs_Read PO--CK 100 100 000 - 10004833994
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -132,8 +132,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: 45/45 Celsius
|
||||
Current Temperature: 70 Celsius
|
||||
Power Cycle Min/Max Temperature: 69/70 Celsius
|
||||
Lifetime Min/Max Temperature: 28/86 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -142,7 +142,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (205)
|
||||
Temperature History Size (Index): 478 (230)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -151,18 +151,18 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 803 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 50815 --- Power-on Hours
|
||||
0x01 0x018 6 47015401651 --- Logical Sectors Written
|
||||
0x01 0x020 6 760860568 --- Number of Write Commands
|
||||
0x01 0x028 6 9994006373 --- Logical Sectors Read
|
||||
0x01 0x030 6 259229586 --- Number of Read Commands
|
||||
0x01 0x008 4 808 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 51282 --- Power-on Hours
|
||||
0x01 0x018 6 47725104043 --- Logical Sectors Written
|
||||
0x01 0x020 6 770111916 --- Number of Write Commands
|
||||
0x01 0x028 6 10004833994 --- Logical Sectors Read
|
||||
0x01 0x030 6 259793995 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 1973 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 45 --- Current Temperature
|
||||
0x05 0x010 1 73 --- Average Short Term Temperature
|
||||
0x05 0x008 1 70 --- Current Temperature
|
||||
0x05 0x010 1 68 --- Average Short Term Temperature
|
||||
0x05 0x018 1 71 --- Average Long Term Temperature
|
||||
0x05 0x020 1 88 --- Highest Temperature
|
||||
0x05 0x028 1 28 --- Lowest Temperature
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Aug 20 14:24:01 2022 EDT
|
||||
Local Time is: Sat Aug 20 19:16:56 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,13 +68,13 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 001 - 28338
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 26
|
||||
9 Power_On_Hours -O--CK 100 100 001 - 28339
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 28
|
||||
170 Grown_Failing_Block_Ct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 001 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 001 - 0
|
||||
173 Wear_Leveling_Count PO--CK 094 094 010 - 208
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 001 - 24
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 001 - 25
|
||||
181 Non4k_Aligned_Access -O---K 100 100 001 - 13319 8642 4676
|
||||
183 SATA_Iface_Downshift -O--CK 100 100 001 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 050 - 0
|
||||
@@ -149,7 +149,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (30)
|
||||
Temperature History Size (Index): 478 (31)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -158,12 +158,12 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 26 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 28338 --- Power-on Hours
|
||||
0x01 0x018 6 37313406908 --- Logical Sectors Written
|
||||
0x01 0x020 6 938253657 --- Number of Write Commands
|
||||
0x01 0x028 6 2704289696 --- Logical Sectors Read
|
||||
0x01 0x030 6 283525193 --- Number of Read Commands
|
||||
0x01 0x008 4 28 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 28339 --- Power-on Hours
|
||||
0x01 0x018 6 37318442181 --- Logical Sectors Written
|
||||
0x01 0x020 6 938270005 --- Number of Write Commands
|
||||
0x01 0x028 6 2704903390 --- Logical Sectors Read
|
||||
0x01 0x030 6 283543943 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -196,5 +196,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 9 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 4 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Oct 31 11:33:12 2021 CET
|
||||
Local Time is: Mon Nov 8 14:11:49 2021 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -30,14 +30,14 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 65) seconds.
|
||||
data collection: ( 595) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
@@ -68,14 +68,14 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 001 - 7982
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 1498
|
||||
9 Power_On_Hours -O--CK 100 100 001 - 8176
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 1500
|
||||
170 Grown_Failing_Block_Ct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 001 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 001 - 0
|
||||
173 Wear_Leveling_Count PO--CK 098 098 010 - 84
|
||||
173 Wear_Leveling_Count PO--CK 098 098 010 - 85
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 001 - 0
|
||||
181 Non4k_Aligned_Access -O---K 100 100 001 - 2398 730 1668
|
||||
181 Non4k_Aligned_Access -O---K 100 100 001 - 2399 731 1668
|
||||
183 SATA_Iface_Downshift -O--CK 100 100 001 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 001 - 0
|
||||
@@ -139,7 +139,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Device State: Active (0)
|
||||
Current Temperature: ? Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
@@ -150,7 +150,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (149)
|
||||
Temperature History Size (Index): 478 (364)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -159,12 +159,12 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 1498 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 7982 --- Power-on Hours
|
||||
0x01 0x018 6 15003828875 --- Logical Sectors Written
|
||||
0x01 0x020 6 374075928 --- Number of Write Commands
|
||||
0x01 0x028 6 26621477271 --- Logical Sectors Read
|
||||
0x01 0x030 6 534918258 --- Number of Read Commands
|
||||
0x01 0x008 4 1500 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 8176 --- Power-on Hours
|
||||
0x01 0x018 6 15131516409 --- Logical Sectors Written
|
||||
0x01 0x020 6 376103949 --- Number of Write Commands
|
||||
0x01 0x028 6 26623583985 --- Logical Sectors Read
|
||||
0x01 0x030 6 535002017 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -197,5 +197,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 2 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Apr 22 21:25:19 2022 UTC
|
||||
Local Time is: Sat Oct 1 10:27:26 2022 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,14 +68,14 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 001 - 1531
|
||||
9 Power_On_Hours -O--CK 100 100 001 - 5413
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 255
|
||||
170 Grown_Failing_Block_Ct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 001 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 001 - 0
|
||||
173 Wear_Leveling_Count PO--CK 100 100 010 - 14
|
||||
173 Wear_Leveling_Count PO--CK 099 099 010 - 40
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 001 - 140
|
||||
181 Non4k_Aligned_Access -O---K 100 100 001 - 268 99 168
|
||||
181 Non4k_Aligned_Access -O---K 100 100 001 - 301 127 174
|
||||
183 SATA_Iface_Downshift -O--CK 100 100 001 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 001 - 0
|
||||
@@ -87,7 +87,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
197 Current_Pending_Sector -O--CK 100 100 001 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 001 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 001 - 0
|
||||
202 Perc_Rated_Life_Used ---RC- 100 100 001 - 0
|
||||
202 Perc_Rated_Life_Used ---RC- 099 099 001 - 1
|
||||
206 Write_Error_Rate -OSR-- 100 100 001 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -149,7 +149,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (265)
|
||||
Temperature History Size (Index): 478 (441)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -159,11 +159,11 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 255 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1531 --- Power-on Hours
|
||||
0x01 0x018 6 1596740614 --- Logical Sectors Written
|
||||
0x01 0x020 6 32524796 --- Number of Write Commands
|
||||
0x01 0x028 6 3158597863 --- Logical Sectors Read
|
||||
0x01 0x030 6 38795670 --- Number of Read Commands
|
||||
0x01 0x010 4 5413 --- Power-on Hours
|
||||
0x01 0x018 6 4696311928 --- Logical Sectors Written
|
||||
0x01 0x020 6 62871333 --- Number of Write Commands
|
||||
0x01 0x028 6 3164264872 --- Logical Sectors Read
|
||||
0x01 0x030 6 39121516 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -196,5 +196,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 23 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Mar 17 20:39:51 2022 HKT
|
||||
Local Time is: Fri Mar 18 15:37:16 2022 HKT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -67,14 +67,14 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 001 - 7496
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 27
|
||||
9 Power_On_Hours -O--CK 100 100 001 - 7514
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 32
|
||||
170 Unknown_Attribute PO--CK 100 100 010 - 0
|
||||
171 Unknown_Attribute -O--CK 100 100 001 - 0
|
||||
172 Unknown_Attribute -O--CK 100 100 001 - 0
|
||||
173 Unknown_Attribute PO--CK 097 097 010 - 116
|
||||
174 Unknown_Attribute -O--CK 100 100 001 - 25
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 001 - 94490460163
|
||||
173 Unknown_Attribute PO--CK 097 097 010 - 117
|
||||
174 Unknown_Attribute -O--CK 100 100 001 - 29
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 001 - 94490460164
|
||||
183 Runtime_Bad_Block -O--CK 100 100 001 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 001 - 0
|
||||
@@ -148,7 +148,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (404)
|
||||
Temperature History Size (Index): 478 (41)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -157,12 +157,12 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 27 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 7496 --- Power-on Hours
|
||||
0x01 0x018 6 4048943840 --- Logical Sectors Written
|
||||
0x01 0x020 6 79155260 --- Number of Write Commands
|
||||
0x01 0x028 6 58363545 --- Logical Sectors Read
|
||||
0x01 0x030 6 1747566 --- Number of Read Commands
|
||||
0x01 0x008 4 32 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 7514 --- Power-on Hours
|
||||
0x01 0x018 6 4071890908 --- Logical Sectors Written
|
||||
0x01 0x020 6 80214131 --- Number of Write Commands
|
||||
0x01 0x028 6 62962381 --- Logical Sectors Read
|
||||
0x01 0x030 6 1891991 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -181,7 +181,7 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 70 --- Number of Hardware Resets
|
||||
0x06 0x008 4 92 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -195,5 +195,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 27 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p20-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Jul 21 13:14:42 2021 UTC
|
||||
Local Time is: Sun Nov 7 08:41:38 2021 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -67,14 +67,14 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 001 - 1375
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 513
|
||||
9 Power_On_Hours -O--CK 100 100 001 - 3920
|
||||
12 Power_Cycle_Count -O--CK 100 100 001 - 544
|
||||
170 Unknown_Attribute PO--CK 100 100 010 - 0
|
||||
171 Unknown_Attribute -O--CK 100 100 001 - 0
|
||||
172 Unknown_Attribute -O--CK 100 100 001 - 0
|
||||
173 Unknown_Attribute PO--CK 100 100 010 - 27
|
||||
174 Unknown_Attribute -O--CK 100 100 001 - 142
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 001 - 9453284754666
|
||||
173 Unknown_Attribute PO--CK 098 098 010 - 70
|
||||
174 Unknown_Attribute -O--CK 100 100 001 - 162
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 001 - 9534889919730
|
||||
183 Runtime_Bad_Block -O--CK 100 100 001 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 001 - 0
|
||||
@@ -86,7 +86,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
197 Current_Pending_Sector -O--CK 100 100 001 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 001 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 001 - 0
|
||||
202 Unknown_SSD_Attribute ---RC- 100 100 001 - 0
|
||||
202 Unknown_SSD_Attribute ---RC- 098 098 001 - 2
|
||||
206 Unknown_SSD_Attribute -OSR-- 100 100 001 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -123,7 +123,8 @@ No Errors Logged
|
||||
SMART Extended Self-test Log size 3449 not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 2307 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -148,7 +149,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (36)
|
||||
Temperature History Size (Index): 478 (126)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -157,12 +158,12 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 513 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1375 --- Power-on Hours
|
||||
0x01 0x018 6 2759665630 --- Logical Sectors Written
|
||||
0x01 0x020 6 50989623 --- Number of Write Commands
|
||||
0x01 0x028 6 3504277916 --- Logical Sectors Read
|
||||
0x01 0x030 6 68839633 --- Number of Read Commands
|
||||
0x01 0x008 4 544 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3920 --- Power-on Hours
|
||||
0x01 0x018 6 8124032782 --- Logical Sectors Written
|
||||
0x01 0x020 6 125048101 --- Number of Write Commands
|
||||
0x01 0x028 6 4084591877 --- Logical Sectors Read
|
||||
0x01 0x030 6 83237408 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -195,5 +196,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 15 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p21-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: MTFDBAK128MAG-1G1
|
||||
@@ -11,10 +11,10 @@ Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
Device is: Not in smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Jan 27 08:34:42 2022 CET
|
||||
Local Time is: Wed Jun 8 09:59:07 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,14 +68,14 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 3
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 1622
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1484
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 2840
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1491
|
||||
170 Unknown_Attribute PO--CK 100 100 010 - 0
|
||||
171 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
172 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
173 Unknown_Attribute PO--CK 093 093 010 - 357
|
||||
173 Unknown_Attribute PO--CK 093 093 010 - 372
|
||||
174 Unknown_Attribute -O--CK 100 100 000 - 3
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 11862763570938
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 11927188997884
|
||||
183 Runtime_Bad_Block -O--CK 100 100 050 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 002 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
@@ -155,7 +155,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (373)
|
||||
Temperature History Size (Index): 478 (38)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -164,12 +164,12 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 1484 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1622 --- Power-on Hours
|
||||
0x01 0x018 6 16384502339 --- Logical Sectors Written
|
||||
0x01 0x020 6 311149326 --- Number of Write Commands
|
||||
0x01 0x028 6 30415520958 --- Logical Sectors Read
|
||||
0x01 0x030 6 584800383 --- Number of Read Commands
|
||||
0x01 0x008 4 1491 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2840 --- Power-on Hours
|
||||
0x01 0x018 6 17064871250 --- Logical Sectors Written
|
||||
0x01 0x020 6 321021131 --- Number of Write Commands
|
||||
0x01 0x028 6 30432345936 --- Logical Sectors Read
|
||||
0x01 0x030 6 585391466 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -188,7 +188,7 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 6655 --- Number of Hardware Resets
|
||||
0x06 0x008 4 6739 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 4 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -202,5 +202,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 16 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 22 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Jul 15 22:14:21 2022 CEST
|
||||
Local Time is: Mon Nov 14 20:12:21 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,14 +68,14 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 4434
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1865
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 7243
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1870
|
||||
170 Grown_Failing_Block_Ct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Wear_Leveling_Count PO--CK 081 081 010 - 571
|
||||
173 Wear_Leveling_Count PO--CK 079 079 010 - 648
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 3
|
||||
181 Non4k_Aligned_Access -O---K 100 100 000 - 9725 6586 3138
|
||||
181 Non4k_Aligned_Access -O---K 100 100 000 - 10372 7228 3143
|
||||
183 SATA_Iface_Downshift -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
@@ -87,7 +87,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 0
|
||||
202 Perc_Rated_Life_Used ---RC- 082 082 000 - 18
|
||||
202 Perc_Rated_Life_Used ---RC- 079 079 000 - 21
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -148,7 +148,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (433)
|
||||
Temperature History Size (Index): 478 (21)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -157,12 +157,12 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 1865 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 4434 --- Power-on Hours
|
||||
0x01 0x018 6 106011391828 --- Logical Sectors Written
|
||||
0x01 0x020 6 1535484625 --- Number of Write Commands
|
||||
0x01 0x028 6 30539141832 --- Logical Sectors Read
|
||||
0x01 0x030 6 340463477 --- Number of Read Commands
|
||||
0x01 0x008 4 1870 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 7243 --- Power-on Hours
|
||||
0x01 0x018 6 111855263224 --- Logical Sectors Written
|
||||
0x01 0x020 6 1645493701 --- Number of Write Commands
|
||||
0x01 0x028 6 31301269130 --- Logical Sectors Read
|
||||
0x01 0x030 6 351931085 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -181,7 +181,7 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 60 --- Number of Hardware Resets
|
||||
0x06 0x008 4 78 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p14-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Feb 3 18:54:38 2021 UTC
|
||||
Local Time is: Sun Mar 21 19:46:57 2021 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,14 +68,14 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 1922
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1504
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 2814
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1512
|
||||
170 Grown_Failing_Block_Ct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Wear_Leveling_Count PO--CK 098 098 010 - 69
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 275
|
||||
181 Non4k_Aligned_Access -O---K 100 100 000 - 951 380 570
|
||||
173 Wear_Leveling_Count PO--CK 098 098 010 - 83
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 281
|
||||
181 Non4k_Aligned_Access -O---K 100 100 000 - 952 380 571
|
||||
183 SATA_Iface_Downshift -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
@@ -146,7 +146,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (82)
|
||||
Temperature History Size (Index): 478 (83)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -155,12 +155,12 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 1504 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1922 --- Power-on Hours
|
||||
0x01 0x018 6 9176296760 --- Logical Sectors Written
|
||||
0x01 0x020 6 164476688 --- Number of Write Commands
|
||||
0x01 0x028 6 8581232372 --- Logical Sectors Read
|
||||
0x01 0x030 6 140642111 --- Number of Read Commands
|
||||
0x01 0x008 4 1512 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2814 --- Power-on Hours
|
||||
0x01 0x018 6 11982634438 --- Logical Sectors Written
|
||||
0x01 0x020 6 200126675 --- Number of Write Commands
|
||||
0x01 0x028 6 8654424189 --- Logical Sectors Read
|
||||
0x01 0x030 6 142127307 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p16-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jan 30 05:36:36 2021 AEDT
|
||||
Local Time is: Sun May 23 14:29:23 2021 AEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -23,7 +23,7 @@ APM level is: 0 (reserved)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
@@ -68,21 +68,21 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 337
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 4658
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 3056
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 4667
|
||||
170 Grown_Failing_Block_Ct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Wear_Leveling_Count PO--CK 099 099 010 - 31
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 1
|
||||
181 Non4k_Aligned_Access -O---K 100 100 000 - 1484 427 1056
|
||||
181 Non4k_Aligned_Access -O---K 100 100 000 - 1485 428 1057
|
||||
183 SATA_Iface_Downshift -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 Factory_Bad_Block_Ct -OSR-- 100 100 000 - 88
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 0
|
||||
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 37
|
||||
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 262
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
@@ -148,7 +148,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (408)
|
||||
Temperature History Size (Index): 478 (374)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -157,25 +157,25 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 4658 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 337 --- Power-on Hours
|
||||
0x01 0x018 6 9737157431 --- Logical Sectors Written
|
||||
0x01 0x020 6 208090353 --- Number of Write Commands
|
||||
0x01 0x028 6 14715337604 --- Logical Sectors Read
|
||||
0x01 0x030 6 273165795 --- Number of Read Commands
|
||||
0x01 0x008 4 4667 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3056 --- Power-on Hours
|
||||
0x01 0x018 6 9799324290 --- Logical Sectors Written
|
||||
0x01 0x020 6 209216106 --- Number of Write Commands
|
||||
0x01 0x028 6 14718792254 --- Logical Sectors Read
|
||||
0x01 0x030 6 273241058 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 0 --- Current Temperature
|
||||
0x05 0x010 1 0 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x018 1 0 --- Average Long Term Temperature
|
||||
0x05 0x020 1 0 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 0 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 0 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x040 1 0 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 0 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 - --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
@@ -195,5 +195,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 16 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p16-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jan 30 05:36:36 2021 AEDT
|
||||
Local Time is: Sun May 23 14:29:23 2021 AEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -23,7 +23,7 @@ APM level is: 0 (reserved)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
@@ -68,14 +68,14 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 8472
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 9076
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 11191
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 9084
|
||||
170 Grown_Failing_Block_Ct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Wear_Leveling_Count PO--CK 099 099 010 - 58
|
||||
173 Wear_Leveling_Count PO--CK 092 092 010 - 245
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 0
|
||||
181 Non4k_Aligned_Access -O---K 100 100 000 - 2099 363 1735
|
||||
181 Non4k_Aligned_Access -O---K 100 100 000 - 2100 363 1736
|
||||
183 SATA_Iface_Downshift -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
@@ -87,7 +87,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 0
|
||||
202 Perc_Rated_Life_Used ---RC- 099 099 000 - 1
|
||||
202 Perc_Rated_Life_Used ---RC- 092 092 000 - 8
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -148,7 +148,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (135)
|
||||
Temperature History Size (Index): 478 (100)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -157,12 +157,12 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 9076 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 8472 --- Power-on Hours
|
||||
0x01 0x018 6 16952196089 --- Logical Sectors Written
|
||||
0x01 0x020 6 265650206 --- Number of Write Commands
|
||||
0x01 0x028 6 30216832010 --- Logical Sectors Read
|
||||
0x01 0x030 6 397152377 --- Number of Read Commands
|
||||
0x01 0x008 4 9084 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 11191 --- Power-on Hours
|
||||
0x01 0x018 6 80421647851 --- Logical Sectors Written
|
||||
0x01 0x020 6 1084580714 --- Number of Write Commands
|
||||
0x01 0x028 6 36665029719 --- Logical Sectors Read
|
||||
0x01 0x030 6 452017727 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -195,7 +195,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 19 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
0x000a 4 7 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sun Jul 18 13:25:19 2021 CEST
|
||||
Local Time is: Tue Jul 20 05:58:45 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,14 +68,14 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 1301
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 224
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 1340
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 233
|
||||
170 Grown_Failing_Block_Ct PO--CK 100 100 010 - 0
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Wear_Leveling_Count PO--CK 100 100 010 - 28
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 42
|
||||
181 Non4k_Aligned_Access -O---K 100 100 000 - 1545 890 655
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 50
|
||||
181 Non4k_Aligned_Access -O---K 100 100 000 - 1546 890 656
|
||||
183 SATA_Iface_Downshift -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
@@ -146,7 +146,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (236)
|
||||
Temperature History Size (Index): 478 (266)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -155,12 +155,12 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 224 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1301 --- Power-on Hours
|
||||
0x01 0x018 6 9077782192 --- Logical Sectors Written
|
||||
0x01 0x020 6 258267551 --- Number of Write Commands
|
||||
0x01 0x028 6 16615584660 --- Logical Sectors Read
|
||||
0x01 0x030 6 280355601 --- Number of Read Commands
|
||||
0x01 0x008 4 233 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1340 --- Power-on Hours
|
||||
0x01 0x018 6 9103453744 --- Logical Sectors Written
|
||||
0x01 0x020 6 258595330 --- Number of Write Commands
|
||||
0x01 0x028 6 16624603040 --- Logical Sectors Read
|
||||
0x01 0x030 6 280591248 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -193,5 +193,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 4
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Oct 23 01:47:17 2021 +03
|
||||
Local Time is: Tue Oct 26 20:59:19 2021 +03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 6073
|
||||
11 Unknown_SSD_Attribute -O---K 100 100 000 - 87
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 5982
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 6164
|
||||
11 Unknown_SSD_Attribute -O---K 100 100 000 - 88
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 5983
|
||||
171 Program_Fail_Count -O---K 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count PO--CK 095 095 010 - 151
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 87
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 15290161957180
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 88
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 15294456990012
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 1
|
||||
184 Error_Correction_Count PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 1516
|
||||
194 Temperature_Celsius -O---K 062 053 000 - 38 (Min/Max 17/47)
|
||||
188 Command_Timeout -O--CK 100 100 000 - 1517
|
||||
194 Temperature_Celsius -O---K 061 053 000 - 39 (Min/Max 17/47)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O---K 100 100 000 - 0
|
||||
@@ -137,8 +137,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/39 Celsius
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/47 Celsius
|
||||
Lifetime Min/Max Temperature: 17/47 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -148,29 +148,29 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (329)
|
||||
Temperature History Size (Index): 478 (64)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 5982 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 6073 --- Power-on Hours
|
||||
0x01 0x018 6 20248173934 --- Logical Sectors Written
|
||||
0x01 0x020 6 464787434 --- Number of Write Commands
|
||||
0x01 0x028 6 44814421190 --- Logical Sectors Read
|
||||
0x01 0x030 6 925912378 --- Number of Read Commands
|
||||
0x01 0x008 4 5983 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 6164 --- Power-on Hours
|
||||
0x01 0x018 6 20296861199 --- Logical Sectors Written
|
||||
0x01 0x020 6 465451082 --- Number of Write Commands
|
||||
0x01 0x028 6 44818594847 --- Logical Sectors Read
|
||||
0x01 0x030 6 926029827 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 1516 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 1517 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x010 1 33 --- Average Short Term Temperature
|
||||
0x05 0x008 1 39 --- Current Temperature
|
||||
0x05 0x010 1 43 --- Average Short Term Temperature
|
||||
0x05 0x018 1 34 --- Average Long Term Temperature
|
||||
0x05 0x020 1 47 --- Highest Temperature
|
||||
0x05 0x028 1 17 --- Lowest Temperature
|
||||
0x05 0x030 1 38 --- Highest Average Short Term Temperature
|
||||
0x05 0x030 1 43 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 30 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 35 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 34 --- Lowest Average Long Term Temperature
|
||||
@@ -179,7 +179,7 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 4154 --- Number of Hardware Resets
|
||||
0x06 0x008 4 4157 --- Number of Hardware Resets
|
||||
0x06 0x010 4 215 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -193,5 +193,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 9 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 4
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue May 11 13:03:05 2021 CEST
|
||||
Local Time is: Mon May 24 13:24:33 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,19 +65,19 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 6997
|
||||
11 Unknown_SSD_Attribute -O---K 100 100 000 - 297
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1388
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 7155
|
||||
11 Unknown_SSD_Attribute -O---K 100 100 000 - 315
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1421
|
||||
171 Program_Fail_Count -O---K 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count PO--CK 096 096 010 - 122
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 297
|
||||
173 Ave_Block-Erase_Count PO--CK 096 096 010 - 124
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 315
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 19091236260610
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 556
|
||||
194 Temperature_Celsius -O---K 067 053 000 - 33 (Min/Max 6/47)
|
||||
188 Command_Timeout -O--CK 100 100 000 - 576
|
||||
194 Temperature_Celsius -O---K 068 053 000 - 32 (Min/Max 6/47)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O---K 100 100 000 - 0
|
||||
@@ -121,15 +121,18 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 6976 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 6886 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 5356 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 5237 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 5199 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 5184 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 5160 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 4947 -
|
||||
# 9 Short offline Completed without error 00% 0 -
|
||||
# 1 Vendor (0xff) Completed without error 00% 7136 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 7085 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 7065 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 6976 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 6886 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 5356 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 5237 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 5199 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 5184 -
|
||||
#10 Vendor (0xff) Completed without error 00% 5160 -
|
||||
#11 Vendor (0xff) Completed without error 00% 4947 -
|
||||
#12 Short offline Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -145,8 +148,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/36 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/32 Celsius
|
||||
Lifetime Min/Max Temperature: 6/47 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -156,25 +159,25 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (25)
|
||||
Temperature History Size (Index): 478 (468)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 1388 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 6997 --- Power-on Hours
|
||||
0x01 0x018 6 10569357612 --- Logical Sectors Written
|
||||
0x01 0x020 6 287414969 --- Number of Write Commands
|
||||
0x01 0x028 6 19064498502 --- Logical Sectors Read
|
||||
0x01 0x030 6 442126164 --- Number of Read Commands
|
||||
0x01 0x008 4 1421 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 7155 --- Power-on Hours
|
||||
0x01 0x018 6 10678835379 --- Logical Sectors Written
|
||||
0x01 0x020 6 291378770 --- Number of Write Commands
|
||||
0x01 0x028 6 19101497225 --- Logical Sectors Read
|
||||
0x01 0x030 6 443350070 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 556 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x010 4 576 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 33 --- Average Short Term Temperature
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x010 1 29 --- Average Short Term Temperature
|
||||
0x05 0x018 1 29 --- Average Long Term Temperature
|
||||
0x05 0x020 1 47 --- Highest Temperature
|
||||
0x05 0x028 1 6 --- Lowest Temperature
|
||||
@@ -187,8 +190,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 4276 --- Number of Hardware Resets
|
||||
0x06 0x010 4 889 --- Number of ASR Events
|
||||
0x06 0x008 4 4517 --- Number of Hardware Resets
|
||||
0x06 0x010 4 956 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 4 N-- Percentage Used Endurance Indicator
|
||||
@@ -201,7 +204,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 6 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jul 10 02:51:09 2021 CEST
|
||||
Local Time is: Sat Jul 10 04:11:22 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,7 +65,7 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 10345
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 10346
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 733
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
@@ -77,13 +77,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
184 Error_Correction_Count PO-RCK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 1343
|
||||
194 Temperature_Celsius -O---K 072 048 000 - 28 (Min/Max 15/52)
|
||||
194 Temperature_Celsius -O---K 071 048 000 - 29 (Min/Max 15/52)
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
240 Unknown_SSD_Attribute -O--CK 100 100 000 - 10646727 (0 0 63)
|
||||
241 Total_LBAs_Written -O--CK 100 100 000 - 34156374784
|
||||
242 Total_LBAs_Read -O--CK 100 100 000 - 83250847287
|
||||
243 Unknown_Attribute -O--CK 100 100 000 - 2355525979
|
||||
240 Unknown_SSD_Attribute -O--CK 100 100 000 - 10700607 (0 0 63)
|
||||
241 Total_LBAs_Written -O--CK 100 100 000 - 34158098944
|
||||
242 Total_LBAs_Read -O--CK 100 100 000 - 83250852159
|
||||
243 Unknown_Attribute -O--CK 100 100 000 - 2355601123
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -163,7 +163,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 28 Celsius
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/30 Celsius
|
||||
Lifetime Min/Max Temperature: 15/52 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
@@ -174,7 +174,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (71)
|
||||
Temperature History Size (Index): 478 (151)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -182,16 +182,16 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 733 -D- Lifetime Power-On Resets
|
||||
0x01 0x010 4 10345 -D- Power-on Hours
|
||||
0x01 0x018 6 34156374784 -D- Logical Sectors Written
|
||||
0x01 0x020 6 1126054641 -D- Number of Write Commands
|
||||
0x01 0x028 6 83250847287 -D- Logical Sectors Read
|
||||
0x01 0x030 6 2656069482 -D- Number of Read Commands
|
||||
0x01 0x010 4 10346 -D- Power-on Hours
|
||||
0x01 0x018 6 34158098944 -D- Logical Sectors Written
|
||||
0x01 0x020 6 1126079128 -D- Number of Write Commands
|
||||
0x01 0x028 6 83250852159 -D- Logical Sectors Read
|
||||
0x01 0x030 6 2656069653 -D- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 -D- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 1343 -D- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 28 -D- Current Temperature
|
||||
0x05 0x008 1 29 -D- Current Temperature
|
||||
0x05 0x010 1 40 -D- Average Short Term Temperature
|
||||
0x05 0x018 1 40 -D- Average Long Term Temperature
|
||||
0x05 0x020 1 52 -D- Highest Temperature
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p20-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Feb 8 05:42:08 2021 CET
|
||||
Local Time is: Mon Nov 1 23:26:45 2021 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -67,13 +67,13 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 1503
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1326
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 7333
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1351
|
||||
170 Unknown_Attribute PO--CK 100 100 010 - 0
|
||||
171 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
172 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
173 Unknown_Attribute PO--CK 098 098 010 - 74
|
||||
174 Unknown_Attribute -O--CK 100 100 000 - 313
|
||||
174 Unknown_Attribute -O--CK 100 100 000 - 337
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 3951377122089
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
@@ -146,7 +146,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (214)
|
||||
Temperature History Size (Index): 478 (400)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -155,12 +155,12 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 1326 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1503 --- Power-on Hours
|
||||
0x01 0x008 4 1351 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 7333 --- Power-on Hours
|
||||
0x01 0x018 6 7311953967 --- Logical Sectors Written
|
||||
0x01 0x020 6 129369692 --- Number of Write Commands
|
||||
0x01 0x028 6 15075172619 --- Logical Sectors Read
|
||||
0x01 0x030 6 280971390 --- Number of Read Commands
|
||||
0x01 0x028 6 15075185164 --- Logical Sectors Read
|
||||
0x01 0x030 6 280975160 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -179,7 +179,7 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 54 --- Number of Hardware Resets
|
||||
0x06 0x008 4 119 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 220 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -193,7 +193,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 55 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 11 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-BETA3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Form Factor: < 1.8 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Jun 9 20:35:25 2020 CEST
|
||||
Local Time is: Sat Oct 3 11:08:40 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -21,7 +21,7 @@ APM level is: 0 (reserved)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
@@ -66,14 +66,14 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 69
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 2048 (0 2)
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 687
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 5078
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 854
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 5115
|
||||
170 Unknown_Attribute PO--CK 100 100 010 - 65
|
||||
171 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
172 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
173 Unknown_Attribute PO--CK 098 098 010 - 89
|
||||
174 Unknown_Attribute -O--CK 100 100 000 - 165
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 5269936866323
|
||||
173 Unknown_Attribute PO--CK 097 097 010 - 106
|
||||
174 Unknown_Attribute -O--CK 100 100 000 - 170
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 5269936866324
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 515
|
||||
@@ -85,7 +85,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 0
|
||||
202 Unknown_SSD_Attribute ---RC- 098 098 000 - 2
|
||||
202 Unknown_SSD_Attribute ---RC- 097 097 000 - 3
|
||||
206 Unknown_SSD_Attribute -OSR-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -145,7 +145,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (396)
|
||||
Temperature History Size (Index): 478 (207)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 40 (4.0 seconds)
|
||||
@@ -154,12 +154,12 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 5078 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 687 --- Power-on Hours
|
||||
0x01 0x018 6 17315383236 --- Logical Sectors Written
|
||||
0x01 0x020 6 310672297 --- Number of Write Commands
|
||||
0x01 0x028 6 21772653877 --- Logical Sectors Read
|
||||
0x01 0x030 6 342420729 --- Number of Read Commands
|
||||
0x01 0x008 4 5115 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 854 --- Power-on Hours
|
||||
0x01 0x018 6 20850695988 --- Logical Sectors Written
|
||||
0x01 0x020 6 408305017 --- Number of Write Commands
|
||||
0x01 0x028 6 24505945712 --- Logical Sectors Read
|
||||
0x01 0x030 6 414553993 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 515 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
@@ -178,7 +178,7 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 274 --- Number of Hardware Resets
|
||||
0x06 0x008 4 284 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -192,5 +192,5 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 4 48 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 4
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Dec 30 03:01:01 2022 UTC
|
||||
Local Time is: Fri Dec 30 03:36:45 2022 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,7 +65,7 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 18934
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 18935
|
||||
11 Unknown_SSD_Attribute -O---K 100 100 000 - 462
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1915
|
||||
171 Program_Fail_Count -O---K 100 100 000 - 0
|
||||
@@ -161,7 +161,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (162)
|
||||
Temperature History Size (Index): 478 (198)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -169,11 +169,11 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 1915 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 18934 --- Power-on Hours
|
||||
0x01 0x018 6 46256469857 --- Logical Sectors Written
|
||||
0x01 0x020 6 723505803 --- Number of Write Commands
|
||||
0x01 0x028 6 18821321386 --- Logical Sectors Read
|
||||
0x01 0x030 6 278762466 --- Number of Read Commands
|
||||
0x01 0x010 4 18935 --- Power-on Hours
|
||||
0x01 0x018 6 46258756161 --- Logical Sectors Written
|
||||
0x01 0x020 6 723570121 --- Number of Write Commands
|
||||
0x01 0x028 6 18821356562 --- Logical Sectors Read
|
||||
0x01 0x030 6 278765600 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 1547 --- Resets Between Cmd Acceptance and Completion
|
||||
|
Reference in New Issue