1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 14, modified: 3797)

This commit is contained in:
Andrey Ponomarenko
2023-02-14 02:15:20 +03:00
parent 274416644b
commit a41331e270
3811 changed files with 71570 additions and 67733 deletions

View File

@@ -13,8 +13,8 @@ Rotation Rate: Solid State Device
TRIM Command: Available, deterministic
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Apr 23 18:14:38 2022 CEST
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sat Oct 15 14:44:40 2022 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
@@ -58,10 +58,10 @@ SCT capabilities: (0x0021) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 120 120 050 Pre-fail Always - 0/0
1 Raw_Read_Error_Rate 0x000f 086 086 050 Pre-fail Always - 0/3291889
5 Retired_Block_Count 0x0033 100 100 003 Pre-fail Always - 1
9 Power_On_Hours_and_Msec 0x0032 068 068 000 Old_age Always - 28477h+30m+09.870s
12 Power_Cycle_Count 0x0032 095 095 000 Old_age Always - 5229
9 Power_On_Hours_and_Msec 0x0032 068 068 000 Old_age Always - 28482h+04m+19.080s
12 Power_Cycle_Count 0x0032 095 095 000 Old_age Always - 5236
171 Program_Fail_Count 0x0032 000 000 000 Old_age Always - 1
172 Erase_Fail_Count 0x0032 000 000 000 Old_age Always - 0
174 Unexpect_Power_Loss_Ct 0x0030 000 000 000 Old_age Offline - 67
@@ -70,16 +70,16 @@ ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_
182 Erase_Fail_Count 0x0032 000 000 000 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
194 Temperature_Celsius 0x0022 030 030 000 Old_age Always - 30 (Min/Max 30/30)
195 ECC_Uncorr_Error_Count 0x001c 100 100 000 Old_age Offline - 0/0
195 ECC_Uncorr_Error_Count 0x001c 120 120 000 Old_age Offline - 0/3291889
196 Reallocated_Event_Count 0x0033 100 100 003 Pre-fail Always - 1
201 Unc_Soft_Read_Err_Rate 0x001c 100 100 000 Old_age Offline - 0/0
204 Soft_ECC_Correct_Rate 0x001c 100 100 000 Old_age Offline - 0/0
201 Unc_Soft_Read_Err_Rate 0x001c 120 120 000 Old_age Offline - 0/3291889
204 Soft_ECC_Correct_Rate 0x001c 120 120 000 Old_age Offline - 0/3291889
230 Life_Curve_Status 0x0013 100 100 000 Pre-fail Always - 100
231 SSD_Life_Left 0x0013 100 100 010 Pre-fail Always - 0
233 SandForce_Internal 0x0000 000 000 000 Old_age Offline - 19996
234 SandForce_Internal 0x0032 000 000 000 Old_age Always - 13760
241 Lifetime_Writes_GiB 0x0032 000 000 000 Old_age Always - 13760
242 Lifetime_Reads_GiB 0x0032 000 000 000 Old_age Always - 42433
233 SandForce_Internal 0x0000 000 000 000 Old_age Offline - 20009
234 SandForce_Internal 0x0032 000 000 000 Old_age Always - 13790
241 Lifetime_Writes_GiB 0x0032 000 000 000 Old_age Always - 13790
242 Lifetime_Reads_GiB 0x0032 000 000 000 Old_age Always - 42555
SMART Error Log not supported

View File

@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Thu May 5 16:30:36 2022 EDT
Local Time is: Fri May 6 13:43:41 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,7 +65,7 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 120 120 050 - 0/0
5 Retired_Block_Count PO--CK 100 100 003 - 1
9 Power_On_Hours_and_Msec -O--CK 000 000 000 - 64265h+27m+53.340s
9 Power_On_Hours_and_Msec -O--CK 000 000 000 - 64286h+40m+05.240s
12 Power_Cycle_Count -O--CK 100 100 000 - 114
171 Program_Fail_Count -O--CK 000 000 000 - 0
172 Erase_Fail_Count -O--CK 000 000 000 - 0
@@ -81,10 +81,10 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
204 Soft_ECC_Correct_Rate --SRC- 100 100 000 - 0/0
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left PO--C- 100 100 010 - 0
233 SandForce_Internal ------ 000 000 000 - 11464
234 SandForce_Internal -O--CK 000 000 000 - 12413
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 12413
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 4313
233 SandForce_Internal ------ 000 000 000 - 11468
234 SandForce_Internal -O--CK 000 000 000 - 12417
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 12417
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 4314
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate

View File

@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Jul 13 05:03:27 2021 EEST
Local Time is: Mon Jul 26 12:03:28 2021 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,11 +65,11 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 120 120 050 - 0/0
5 Retired_Block_Count PO--CK 100 100 003 - 0
9 Power_On_Hours_and_Msec -O--CK 000 000 000 - 55435h+38m+23.670s
12 Power_Cycle_Count -O--CK 095 095 000 - 5280
9 Power_On_Hours_and_Msec -O--CK 000 000 000 - 55665h+45m+54.370s
12 Power_Cycle_Count -O--CK 095 095 000 - 5302
171 Program_Fail_Count -O--CK 000 000 000 - 0
172 Erase_Fail_Count -O--CK 000 000 000 - 0
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 2478
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 2479
177 Wear_Range_Delta ------ 000 000 000 - 11
181 Program_Fail_Count -O--CK 000 000 000 - 0
182 Erase_Fail_Count -O--CK 000 000 000 - 0
@@ -81,10 +81,10 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
204 Soft_ECC_Correct_Rate --SRC- 100 100 000 - 0/0
230 Life_Curve_Status PO--C- 100 100 000 - 100
231 SSD_Life_Left PO--C- 099 099 010 - 0
233 SandForce_Internal ------ 000 000 000 - 31543
234 SandForce_Internal -O--CK 000 000 000 - 27221
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 27221
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 22841
233 SandForce_Internal ------ 000 000 000 - 31720
234 SandForce_Internal -O--CK 000 000 000 - 27361
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 27361
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 22898
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -137,9 +137,9 @@ Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 10 (Unknown, should be 2)
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 79/100 Celsius
Min/Max Temperature Limit: 56/84 Celsius
Temperature History Size (Index): 26880 (274)
Min/Max recommended Temperature: 0/120 Celsius
Min/Max Temperature Limit: 0/ 0 Celsius
Temperature History Size (Index): 3584 (333)
Invalid Temperature History Size or Index
SCT Error Recovery Control command not supported