mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 129, modified: 0)
This commit is contained in:
@@ -30,34 +30,44 @@ MTBF — avg. MTBF in years per sample.
|
||||
| Seagate | ST3320620A | 320 GB | 1 | 1913 | 0 | 5.24 |
|
||||
| Seagate | ST3500413AS | 500 GB | 2 | 1885 | 0 | 5.17 |
|
||||
| Seagate | ST1000NC001-1DY162 | 1 TB | 1 | 1848 | 0 | 5.06 |
|
||||
| Seagate | ST3320620AS | 320 GB | 1 | 1737 | 0 | 4.76 |
|
||||
| Seagate | ST3250318AS | 250 GB | 1 | 1636 | 0 | 4.48 |
|
||||
| Seagate | ST91000640NS | 1 TB | 1 | 1630 | 0 | 4.47 |
|
||||
| Seagate | ST5000DM000-1FK178 | 5 TB | 1 | 1387 | 0 | 3.80 |
|
||||
| Seagate | ST2000DL003-9VT166 | 2 TB | 3 | 1991 | 1 | 3.32 |
|
||||
| Seagate | ST9250315AS | 250 GB | 1 | 1192 | 0 | 3.27 |
|
||||
| Seagate | ST320LM001 HN-M... | 320 GB | 2 | 1189 | 0 | 3.26 |
|
||||
| Seagate | ST4000LM016-1N2170 | 4 TB | 1 | 1146 | 0 | 3.14 |
|
||||
| Seagate | ST4000DM000-1F2168 | 4 TB | 2 | 1098 | 0 | 3.01 |
|
||||
| Seagate | ST3000DM001-1CH166 | 3 TB | 1 | 1099 | 0 | 3.01 |
|
||||
| Seagate | ST4000DM000-1F2168 | 4 TB | 4 | 1087 | 0 | 2.98 |
|
||||
| Seagate | ST320VT000-1BS14C | 320 GB | 1 | 1083 | 0 | 2.97 |
|
||||
| Seagate | ST3160023A | 160 GB | 1 | 1056 | 0 | 2.89 |
|
||||
| Seagate | ST3250312AS | 250 GB | 1 | 1039 | 0 | 2.85 |
|
||||
| Seagate | ST1000DM003-1CH162 | 1 TB | 1 | 949 | 0 | 2.60 |
|
||||
| Seagate | ST3320620AS | 320 GB | 2 | 1023 | 86 | 2.38 |
|
||||
| Seagate | ST6000DM003-2CY186 | 6 TB | 1 | 765 | 0 | 2.10 |
|
||||
| Seagate | ST2000DM001-1CH164 | 2 TB | 3 | 1143 | 51 | 1.97 |
|
||||
| Seagate | ST5000DM000-1FK178 | 5 TB | 2 | 731 | 0 | 2.01 |
|
||||
| Seagate | ST8000VN0022-2E... | 8 TB | 1 | 658 | 0 | 1.80 |
|
||||
| Seagate | ST2000DM001-1CH164 | 2 TB | 4 | 1084 | 39 | 1.79 |
|
||||
| Seagate | ST8000VN0002-1Z... | 8 TB | 1 | 625 | 0 | 1.71 |
|
||||
| Seagate | ST1000VX000-1CU162 | 1 TB | 1 | 596 | 0 | 1.63 |
|
||||
| Seagate | ST4000LM024-2AN17V | 4 TB | 1 | 579 | 0 | 1.59 |
|
||||
| Seagate | ST5000LM000-2AN170 | 5 TB | 2 | 472 | 0 | 1.30 |
|
||||
| Seagate | ST2000LM015-2E8174 | 2 TB | 2 | 430 | 0 | 1.18 |
|
||||
| Seagate | ST380811AS | 80 GB | 1 | 383 | 0 | 1.05 |
|
||||
| Seagate | ST31500541AS | 1.5 TB | 5 | 649 | 119 | 1.03 |
|
||||
| Seagate | ST1000LM024 HN-... | 1 TB | 1 | 347 | 0 | 0.95 |
|
||||
| Seagate | ST4000VN008-2DR166 | 4 TB | 1 | 239 | 0 | 0.66 |
|
||||
| Seagate | ST1000LM048-2E7172 | 1 TB | 2 | 336 | 0 | 0.92 |
|
||||
| Seagate | ST500LM012 HN-M... | 500 GB | 1 | 213 | 0 | 0.59 |
|
||||
| Seagate | ST4000VN008-2DR166 | 4 TB | 2 | 135 | 0 | 0.37 |
|
||||
| Seagate | ST2000LM007-1R8174 | 2 TB | 1 | 111 | 0 | 0.31 |
|
||||
| Seagate | ST8000DM004-2CX188 | 8 TB | 1 | 82 | 0 | 0.23 |
|
||||
| Seagate | ST500LM030-2E717D | 500 GB | 1 | 55 | 0 | 0.15 |
|
||||
| Seagate | ST500LM021-1KJ152 | 500 GB | 2 | 227 | 505 | 0.14 |
|
||||
| Seagate | ST1000LM048-2E7172 | 1 TB | 1 | 44 | 0 | 0.12 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 16 | 3 | 0 | 0.01 |
|
||||
| Seagate | ST3500514NS | 500 GB | 1 | 205 | 103 | 0.01 |
|
||||
| Seagate | ST2000DM008-2FR102 | 2 TB | 1 | 161 | 144 | 0.00 |
|
||||
| Seagate | ST500LT012-9WS142 | 500 GB | 2 | 488 | 1010 | 0.00 |
|
||||
| Seagate | ST9500420AS | 500 GB | 1 | 315 | 738 | 0.00 |
|
||||
| Seagate | ST1000LM035-1RK172 | 1 TB | 1 | 278 | 910 | 0.00 |
|
||||
|
||||
HDD by Family
|
||||
-------------
|
||||
@@ -76,23 +86,25 @@ MTBF — avg. MTBF in years per sample.
|
||||
| Seagate | Barracuda ES | 1 | 1 | 4005 | 0 | 10.97 |
|
||||
| Seagate | Constellation ES.3 | 1 | 3 | 1988 | 0 | 5.45 |
|
||||
| Seagate | Constellation CS | 1 | 1 | 1848 | 0 | 5.06 |
|
||||
| Seagate | Barracuda 7200.10 | 2 | 2 | 1825 | 0 | 5.00 |
|
||||
| Seagate | Barracuda 7200.12 | 4 | 5 | 1747 | 0 | 4.79 |
|
||||
| Seagate | Constellation.2 (SATA) | 1 | 1 | 1630 | 0 | 4.47 |
|
||||
| Seagate | Desktop HDD.15 | 2 | 3 | 1194 | 0 | 3.27 |
|
||||
| Seagate | Barracuda 7200.10 | 2 | 3 | 1320 | 57 | 3.34 |
|
||||
| Seagate | Barracuda Green (AF) | 1 | 3 | 1991 | 1 | 3.32 |
|
||||
| Seagate | Momentus 5400.6 | 1 | 1 | 1192 | 0 | 3.27 |
|
||||
| Seagate | Unknown | 1 | 1 | 1083 | 0 | 2.97 |
|
||||
| Seagate | Barracuda 7200.7 an... | 1 | 1 | 1056 | 0 | 2.89 |
|
||||
| Seagate | Barracuda Compute | 1 | 1 | 765 | 0 | 2.10 |
|
||||
| Seagate | Barracuda 7200.14 (AF) | 1 | 3 | 1143 | 51 | 1.97 |
|
||||
| Seagate | Desktop HDD.15 | 2 | 6 | 968 | 0 | 2.65 |
|
||||
| Seagate | Barracuda 7200.14 (AF) | 3 | 6 | 1064 | 26 | 2.13 |
|
||||
| Seagate | SpinPoint M8 (AF) | 3 | 4 | 735 | 0 | 2.01 |
|
||||
| Seagate | NAS HDD | 1 | 1 | 625 | 0 | 1.71 |
|
||||
| Seagate | Surveillance | 1 | 1 | 596 | 0 | 1.63 |
|
||||
| Seagate | Laptop HDD | 2 | 3 | 534 | 337 | 1.14 |
|
||||
| Seagate | Barracuda Compute | 2 | 2 | 423 | 0 | 1.16 |
|
||||
| Seagate | Barracuda 2.5 5400 | 5 | 8 | 389 | 0 | 1.07 |
|
||||
| Seagate | Barracuda 7200.9 | 1 | 1 | 383 | 0 | 1.05 |
|
||||
| Seagate | SpinPoint M8 (AF) | 2 | 2 | 280 | 0 | 0.77 |
|
||||
| Seagate | Barracuda 2.5 5400 | 3 | 4 | 240 | 0 | 0.66 |
|
||||
| Seagate | Mobile HDD | 1 | 1 | 111 | 0 | 0.31 |
|
||||
| Seagate | IronWolf | 3 | 18 | 53 | 0 | 0.15 |
|
||||
| Seagate | Barracuda LP | 1 | 5 | 649 | 119 | 1.03 |
|
||||
| Seagate | Laptop HDD | 3 | 5 | 515 | 606 | 0.68 |
|
||||
| Seagate | Mobile HDD | 2 | 2 | 195 | 455 | 0.15 |
|
||||
| Seagate | IronWolf | 3 | 19 | 52 | 0 | 0.14 |
|
||||
| Seagate | Constellation ES (S... | 1 | 1 | 205 | 103 | 0.01 |
|
||||
| Seagate | BarraCuda 3.5 | 1 | 1 | 161 | 144 | 0.00 |
|
||||
| Seagate | Momentus 7200.4 | 1 | 1 | 315 | 738 | 0.00 |
|
||||
|
175
HDD/Seagate/ST1000/ST1000DM003-1CH162/66F5C343384B
Normal file
175
HDD/Seagate/ST1000/ST1000DM003-1CH162/66F5C343384B
Normal file
@@ -0,0 +1,175 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST1000DM003-1CH162
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC49
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Jun 3 12:31:47 2020 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 575) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 109) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 120 099 006 - 235913216
|
||||
3 Spin_Up_Time PO---- 097 097 000 - 0
|
||||
4 Start_Stop_Count -O--CK 094 094 020 - 6685
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 084 060 030 - 274351639
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 22794
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1377
|
||||
183 Runtime_Bad_Block -O--CK 073 073 000 - 27
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 097 000 - 98 98 128
|
||||
189 High_Fly_Writes -O-RCK 090 090 000 - 10
|
||||
190 Airflow_Temperature_Cel -O---K 071 053 045 - 29 (0 4 29 22 0)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 594
|
||||
193 Load_Cycle_Count -O--CK 087 087 000 - 27004
|
||||
194 Temperature_Celsius -O---K 029 047 000 - 29 (128 0 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 13386h+31m+58.636s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 48246273474
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 23605111409
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 15805 -
|
||||
# 2 Extended offline Interrupted (host reset) 90% 15726 -
|
||||
# 3 Extended offline Interrupted (host reset) 00% 15721 -
|
||||
# 4 Extended offline Interrupted (host reset) 90% 15705 -
|
||||
# 5 Extended offline Interrupted (host reset) 30% 15528 -
|
||||
# 6 Extended offline Interrupted (host reset) 00% 15522 -
|
||||
# 7 Extended offline Interrupted (host reset) 90% 15224 -
|
||||
# 8 Extended offline Completed without error 00% 15002 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/26 Celsius
|
||||
Lifetime Min/Max Temperature: 10/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
260
HDD/Seagate/ST1000/ST1000LM035-1RK172/493FEBA03D12
Normal file
260
HDD/Seagate/ST1000/ST1000LM035-1RK172/493FEBA03D12
Normal file
@@ -0,0 +1,260 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Mobile HDD
|
||||
Device Model: ST1000LM035-1RK172
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SDM4
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Jun 4 17:28:47 2020 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 160) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 080 052 006 - 106401579
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 098 098 020 - 2220
|
||||
5 Reallocated_Sector_Ct PO--CK 099 099 036 - 720
|
||||
7 Seek_Error_Rate POSR-- 087 060 045 - 544771362
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 6688 (56 134 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 261
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 001 001 000 - 190
|
||||
188 Command_Timeout -O--CK 100 099 000 - 81605623827
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 063 051 040 - 37 (Min/Max 34/37)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 6
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 43
|
||||
193 Load_Cycle_Count -O--CK 095 095 000 - 10346
|
||||
194 Temperature_Celsius -O---K 037 049 000 - 37 (0 18 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 6564 (164 2 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 46641818558
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 24763127262
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa8 GPL,SL VS 136 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 8920 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc2 GPL,SL VS 240 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xc9 GPL,SL VS 1 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
Device Error Count: 190 (device log contains only the most recent 20 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 190 [9] log entry is empty
|
||||
Error 189 [8] log entry is empty
|
||||
Error 188 [7] log entry is empty
|
||||
Error 187 [6] log entry is empty
|
||||
Error 186 [5] log entry is empty
|
||||
Error 185 [4] log entry is empty
|
||||
Error 184 [3] occurred at disk power-on lifetime: 5090 hours (212 days + 2 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 3f 96 54 38 00 00 Error: WP at LBA = 0x3f965438 = 1066816568
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 00 00 08 00 00 3a c6 21 d0 40 00 00:48:02.990 WRITE FPDMA QUEUED
|
||||
61 00 00 00 08 00 00 3a c4 d2 78 40 00 00:48:02.990 WRITE FPDMA QUEUED
|
||||
61 00 00 00 08 00 00 3a c5 a4 78 40 00 00:48:02.990 WRITE FPDMA QUEUED
|
||||
61 00 00 00 10 00 00 3a c2 bc 40 40 00 00:48:02.990 WRITE FPDMA QUEUED
|
||||
61 00 00 00 08 00 00 3a c5 a5 00 40 00 00:48:02.990 WRITE FPDMA QUEUED
|
||||
|
||||
Error 183 [2] occurred at disk power-on lifetime: 5090 hours (212 days + 2 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 3f 96 54 38 00 00 Error: WP at LBA = 0x3f965438 = 1066816568
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 00 00 40 00 00 3a 72 ed 00 40 00 00:48:02.738 WRITE FPDMA QUEUED
|
||||
61 00 00 00 40 00 00 3a 84 3b 80 40 00 00:48:02.736 WRITE FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 3f 96 53 80 40 00 00:48:02.735 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 00:48:02.732 READ LOG EXT
|
||||
61 00 00 00 40 00 00 3a 72 ed 00 40 00 00:48:02.545 WRITE FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 34/37 Celsius
|
||||
Lifetime Min/Max Temperature: 18/51 Celsius
|
||||
Specified Max Operating Temperature: 35 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 30 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (46)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 261 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 6688 --- Power-on Hours
|
||||
0x01 0x018 6 46650000478 --- Logical Sectors Written
|
||||
0x01 0x020 6 550877780 --- Number of Write Commands
|
||||
0x01 0x028 6 24763519874 --- Logical Sectors Read
|
||||
0x01 0x030 6 169982000 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 6660 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 3291 --- Head Flying Hours
|
||||
0x03 0x018 4 10346 --- Head Load Events
|
||||
0x03 0x020 4 720 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 198 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 19 --- Resets Between Cmd Acceptance and Completion
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
205
HDD/Seagate/ST1000/ST1000LM048-2E7172/77F31399A547
Normal file
205
HDD/Seagate/ST1000/ST1000LM048-2E7172/77F31399A547
Normal file
@@ -0,0 +1,205 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 2.5 5400
|
||||
Device Model: ST1000LM048-2E7172
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SDM1
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Jun 4 17:28:53 2020 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 163) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 083 060 006 - 194553255
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 090 090 020 - 10657
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 084 060 045 - 18076389305
|
||||
9 Power_On_Hours -O--CK 083 083 000 - 15090 (120 18 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 423
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 071 040 040 Past 29 (Min/Max 29/31)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 70
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 123
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 355070
|
||||
194 Temperature_Celsius -O---K 029 060 000 - 29 (0 12 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 13053 (161 110 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 71439226053
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 64290458043
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa8 GPL,SL VS 136 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 8920 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc2 GPL,SL VS 240 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xc9 GPL,SL VS 1 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/31 Celsius
|
||||
Lifetime Min/Max Temperature: 12/60 Celsius
|
||||
Specified Max Operating Temperature: 38 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 30 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (102)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 423 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 15090 --- Power-on Hours
|
||||
0x01 0x018 6 71440775966 --- Logical Sectors Written
|
||||
0x01 0x020 6 667910096 --- Number of Write Commands
|
||||
0x01 0x028 6 64306227602 --- Logical Sectors Read
|
||||
0x01 0x030 6 372671641 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 10747 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 3532 --- Head Flying Hours
|
||||
0x03 0x018 4 355070 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 68 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
342
HDD/Seagate/ST2000/ST2000DL003-9VT166/AFBF6EF0CAA2
Normal file
342
HDD/Seagate/ST2000/ST2000DL003-9VT166/AFBF6EF0CAA2
Normal file
@@ -0,0 +1,342 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda Green (AF)
|
||||
Device Model: ST2000DL003-9VT166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC32
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Jun 5 10:59:27 2020 -03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 0 (vendor specific), recommended: 254
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 623) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 340) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x30b7) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 114 099 006 - 76584848
|
||||
3 Spin_Up_Time PO---- 093 091 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1881
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 072 060 030 - 30214917582
|
||||
9 Power_On_Hours -O--CK 047 047 000 - 47142
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1890
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 098 098 000 - 2
|
||||
188 Command_Timeout -O--CK 100 099 000 - 1
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 064 052 045 - 36 (Min/Max 27/39)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 1841
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 1954
|
||||
194 Temperature_Celsius -O---K 036 048 000 - 36 (0 17 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 020 004 000 - 76584848
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 46991 (228 90 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 2643836350
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1972438971
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 20 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2819 Device vendor specific log
|
||||
0xbd GPL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
Device Error Count: 15
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 15 [14] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c7 00 00 Error: UNC at LBA = 0xc385f0c7 = 3280335047
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:31.810 READ FPDMA QUEUED
|
||||
60 00 00 00 10 00 00 03 56 b4 e0 40 00 22:15:31.672 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c6 40 00 22:15:31.672 WRITE FPDMA QUEUED
|
||||
60 00 00 00 10 00 00 03 56 7d 90 40 00 22:15:31.671 READ FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:31.633 CHECK POWER MODE
|
||||
|
||||
Error 14 [13] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c7 00 00 Error: UNC at LBA = 0xc385f0c7 = 3280335047
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:31.810 READ FPDMA QUEUED
|
||||
60 00 00 00 10 00 00 03 56 b4 e0 40 00 22:15:31.672 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c6 40 00 22:15:31.672 WRITE FPDMA QUEUED
|
||||
60 00 00 00 10 00 00 03 56 7d 90 40 00 22:15:31.671 READ FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:31.633 CHECK POWER MODE
|
||||
|
||||
Error 13 [12] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c6 00 00 Error: UNC at LBA = 0xc385f0c6 = 3280335046
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:31.194 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c5 40 00 22:15:31.022 WRITE FPDMA QUEUED
|
||||
60 00 00 00 10 00 00 03 56 05 00 40 00 22:15:31.021 READ FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:30.988 CHECK POWER MODE
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 22:15:30.880 READ LOG EXT
|
||||
|
||||
Error 12 [11] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c6 00 00 Error: UNC at LBA = 0xc385f0c6 = 3280335046
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:31.194 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c5 40 00 22:15:31.022 WRITE FPDMA QUEUED
|
||||
60 00 00 00 10 00 00 03 56 05 00 40 00 22:15:31.021 READ FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:30.988 CHECK POWER MODE
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 22:15:30.880 READ LOG EXT
|
||||
|
||||
Error 11 [10] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c5 00 00 Error: UNC at LBA = 0xc385f0c5 = 3280335045
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:30.558 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c4 40 00 22:15:30.421 WRITE FPDMA QUEUED
|
||||
60 00 00 04 00 00 00 03 55 fc 00 40 00 22:15:30.421 READ FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:30.391 CHECK POWER MODE
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 22:15:30.284 READ LOG EXT
|
||||
|
||||
Error 10 [9] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c5 00 00 Error: UNC at LBA = 0xc385f0c5 = 3280335045
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:30.558 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c4 40 00 22:15:30.421 WRITE FPDMA QUEUED
|
||||
60 00 00 04 00 00 00 03 55 fc 00 40 00 22:15:30.421 READ FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:30.391 CHECK POWER MODE
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 22:15:30.284 READ LOG EXT
|
||||
|
||||
Error 9 [8] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c4 00 00 Error: UNC at LBA = 0xc385f0c4 = 3280335044
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:29.962 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c3 40 00 22:15:29.803 WRITE FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:29.776 CHECK POWER MODE
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 22:15:29.668 READ LOG EXT
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:29.285 READ FPDMA QUEUED
|
||||
|
||||
Error 8 [7] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c4 00 00 Error: UNC at LBA = 0xc385f0c4 = 3280335044
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:29.962 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c3 40 00 22:15:29.803 WRITE FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:29.776 CHECK POWER MODE
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 22:15:29.668 READ LOG EXT
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:29.285 READ FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 47131 -
|
||||
# 2 Short offline Completed without error 00% 47107 -
|
||||
# 3 Short offline Completed without error 00% 47083 -
|
||||
# 4 Short offline Completed without error 00% 47059 -
|
||||
# 5 Short offline Completed without error 00% 47035 -
|
||||
# 6 Extended offline Completed without error 00% 47016 -
|
||||
# 7 Short offline Completed without error 00% 46987 -
|
||||
# 8 Short offline Completed without error 00% 46963 -
|
||||
# 9 Short offline Completed without error 00% 46939 -
|
||||
#10 Short offline Completed without error 00% 46915 -
|
||||
#11 Short offline Completed without error 00% 46891 -
|
||||
#12 Short offline Completed without error 00% 46867 -
|
||||
#13 Extended offline Completed without error 00% 46848 -
|
||||
#14 Short offline Completed without error 00% 46819 -
|
||||
#15 Short offline Completed without error 00% 46796 -
|
||||
#16 Short offline Completed without error 00% 46772 -
|
||||
#17 Short offline Completed without error 00% 46748 -
|
||||
#18 Short offline Completed without error 00% 46724 -
|
||||
#19 Short offline Completed without error 00% 46700 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/39 Celsius
|
||||
Lifetime Min/Max Temperature: 17/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (95)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 34 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
223
HDD/Seagate/ST2000/ST2000DL003-9VT166/C9B14737E223
Normal file
223
HDD/Seagate/ST2000/ST2000DL003-9VT166/C9B14737E223
Normal file
@@ -0,0 +1,223 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda Green (AF)
|
||||
Device Model: ST2000DL003-9VT166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC32
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Jun 5 10:59:26 2020 -03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 254
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 612) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 334) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x30b7) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 114 099 006 - 76191712
|
||||
3 Spin_Up_Time PO---- 093 079 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 402
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 087 060 030 - 648398781
|
||||
9 Power_On_Hours -O--CK 044 044 000 - 49403
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 359
|
||||
183 Runtime_Bad_Block -O--CK 099 099 000 - 1
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 099 099 000 - 1
|
||||
188 Command_Timeout -O--CK 100 094 000 - 65615
|
||||
189 High_Fly_Writes -O-RCK 095 095 000 - 5
|
||||
190 Airflow_Temperature_Cel -O---K 063 052 045 - 37 (Min/Max 28/39)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 266
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 406
|
||||
194 Temperature_Celsius -O---K 037 048 000 - 37 (0 14 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 020 004 000 - 76191712
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 79
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 49387 (232 71 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 3367998481
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1191976738
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 20 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2819 Device vendor specific log
|
||||
0xbd GPL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
Device Error Count: 1
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 21493 hours (895 days + 13 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 e8 29 0a e8 00 00 Error: UNC at LBA = 0xe8290ae8 = 3895003880
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 01 00 00 00 e8 29 0a 20 e0 00 22d+20:41:35.793 READ DMA EXT
|
||||
25 00 00 01 00 00 00 e8 29 09 20 e0 00 22d+20:41:35.793 READ DMA EXT
|
||||
35 00 00 00 08 00 00 94 17 2f e0 e0 00 22d+20:41:35.793 WRITE DMA EXT
|
||||
25 00 00 00 08 00 00 e8 29 09 18 e0 00 22d+20:41:35.792 READ DMA EXT
|
||||
35 00 00 00 28 00 00 94 17 2f b8 e0 00 22d+20:41:35.792 WRITE DMA EXT
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 49392 -
|
||||
# 2 Short offline Completed without error 00% 49368 -
|
||||
# 3 Short offline Completed without error 00% 49344 -
|
||||
# 4 Short offline Completed without error 00% 49320 -
|
||||
# 5 Short offline Completed without error 00% 49296 -
|
||||
# 6 Extended offline Completed without error 00% 49277 -
|
||||
# 7 Short offline Completed without error 00% 49248 -
|
||||
# 8 Short offline Completed without error 00% 49224 -
|
||||
# 9 Short offline Completed without error 00% 49200 -
|
||||
#10 Short offline Completed without error 00% 49176 -
|
||||
#11 Short offline Completed without error 00% 49152 -
|
||||
#12 Short offline Completed without error 00% 49128 -
|
||||
#13 Extended offline Completed without error 00% 49109 -
|
||||
#14 Short offline Completed without error 00% 49080 -
|
||||
#15 Short offline Completed without error 00% 49057 -
|
||||
#16 Short offline Completed without error 00% 49033 -
|
||||
#17 Short offline Completed without error 00% 49009 -
|
||||
#18 Short offline Completed without error 00% 48985 -
|
||||
#19 Short offline Completed without error 00% 48961 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/39 Celsius
|
||||
Lifetime Min/Max Temperature: 14/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (26)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 34 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
192
HDD/Seagate/ST2000/ST2000DL003-9VT166/F78691364020
Normal file
192
HDD/Seagate/ST2000/ST2000DL003-9VT166/F78691364020
Normal file
@@ -0,0 +1,192 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda Green (AF)
|
||||
Device Model: ST2000DL003-9VT166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC32
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Jun 5 10:59:27 2020 -03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 0 (vendor specific), recommended: 254
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 633) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 339) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x30b7) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 114 099 006 - 76173104
|
||||
3 Spin_Up_Time PO---- 093 092 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1880
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 076 060 030 - 13029319093
|
||||
9 Power_On_Hours -O--CK 047 047 000 - 46861
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1877
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 062 051 045 - 38 (Min/Max 29/40)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 1830
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 1940
|
||||
194 Temperature_Celsius -O---K 038 049 000 - 38 (0 17 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 021 004 000 - 76173104
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 46707 (67 225 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 1258048515
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 2144311778
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 20 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2819 Device vendor specific log
|
||||
0xbd GPL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 46851 -
|
||||
# 2 Short offline Completed without error 00% 46827 -
|
||||
# 3 Short offline Completed without error 00% 46803 -
|
||||
# 4 Short offline Completed without error 00% 46779 -
|
||||
# 5 Short offline Completed without error 00% 46754 -
|
||||
# 6 Extended offline Completed without error 00% 46736 -
|
||||
# 7 Short offline Completed without error 00% 46706 -
|
||||
# 8 Short offline Completed without error 00% 46683 -
|
||||
# 9 Short offline Completed without error 00% 46658 -
|
||||
#10 Short offline Completed without error 00% 46634 -
|
||||
#11 Short offline Completed without error 00% 46610 -
|
||||
#12 Short offline Completed without error 00% 46586 -
|
||||
#13 Extended offline Completed without error 00% 46568 -
|
||||
#14 Short offline Completed without error 00% 46538 -
|
||||
#15 Short offline Completed without error 00% 46515 -
|
||||
#16 Short offline Completed without error 00% 46491 -
|
||||
#17 Short offline Completed without error 00% 46467 -
|
||||
#18 Short offline Completed without error 00% 46443 -
|
||||
#19 Short offline Completed without error 00% 46419 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/40 Celsius
|
||||
Lifetime Min/Max Temperature: 17/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (100)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 34 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
203
HDD/Seagate/ST2000/ST2000DM001-1CH164/2F08836FD104
Normal file
203
HDD/Seagate/ST2000/ST2000DM001-1CH164/2F08836FD104
Normal file
@@ -0,0 +1,203 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST2000DM001-1CH164
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC43
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Jun 4 17:28:49 2020 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART Status not supported: Incomplete response, ATA output registers missing
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
Warning: This result is based on an Attribute check.
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 584) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 227) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 111 099 006 - 33611016
|
||||
3 Spin_Up_Time PO---- 098 095 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 953
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 068 058 030 - 21510906520
|
||||
9 Power_On_Hours -O--CK 076 076 000 - 21801
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 846
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 099 099 000 - 1
|
||||
188 Command_Timeout -O--CK 100 099 000 - 1 6 7
|
||||
189 High_Fly_Writes -O-RCK 098 098 000 - 2
|
||||
190 Airflow_Temperature_Cel -O---K 053 039 045 Past 47 (Min/Max 46/47 #9895)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 748
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 1650
|
||||
194 Temperature_Celsius -O---K 047 061 000 - 47 (0 8 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 21457h+10m+47.391s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 46200378072
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 81212636385
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbd GPL VS 512 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
Device Error Count: 1
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 667 hours (27 days + 19 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 00 00 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 04 00 00 00 00 00 00 e0 00 13:26:26.488 READ DMA EXT
|
||||
25 00 00 00 10 00 00 16 f1 11 d0 e0 00 07:31:40.042 READ DMA EXT
|
||||
25 00 00 00 f0 00 00 16 f1 10 e0 e0 00 07:31:40.024 READ DMA EXT
|
||||
25 00 00 00 10 00 00 16 f1 10 d0 e0 00 07:31:40.023 READ DMA EXT
|
||||
25 00 00 00 f0 00 00 16 f1 0f e0 e0 00 07:31:40.019 READ DMA EXT
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 5445 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 47 Celsius
|
||||
Power Cycle Min/Max Temperature: 46/47 Celsius
|
||||
Lifetime Min/Max Temperature: 7/61 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
169
HDD/Seagate/ST3000/ST3000DM001-1CH166/E0B3879C594F
Normal file
169
HDD/Seagate/ST3000/ST3000DM001-1CH166/E0B3879C594F
Normal file
@@ -0,0 +1,169 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST3000DM001-1CH166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC29
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Jun 3 12:31:47 2020 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 592) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 335) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 109 099 006 - 23716624
|
||||
3 Spin_Up_Time PO---- 093 093 000 - 0
|
||||
4 Start_Stop_Count -O--CK 096 096 020 - 4519
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 085 060 030 - 376829743
|
||||
9 Power_On_Hours -O--CK 070 070 000 - 26396
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1742
|
||||
183 Runtime_Bad_Block -O--CK 001 001 000 - 358
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 3 3 5
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 070 052 045 - 30 (0 1 30 22 0)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 589
|
||||
193 Load_Cycle_Count -O--CK 088 088 000 - 25559
|
||||
194 Temperature_Celsius -O---K 030 048 000 - 30 (128 0 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 24026h+01m+47.098s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 87850123392
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 125651990928
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Interrupted (host reset) 70% 20613 -
|
||||
# 2 Extended offline Completed without error 00% 14805 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/29 Celsius
|
||||
Lifetime Min/Max Temperature: 19/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
191
HDD/Seagate/ST3150/ST31500541AS/014C128A7949
Normal file
191
HDD/Seagate/ST3150/ST31500541AS/014C128A7949
Normal file
@@ -0,0 +1,191 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda LP
|
||||
Device Model: ST31500541AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC35
|
||||
User Capacity: 1,500,301,910,016 bytes [1.50 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Wed Jun 3 11:18:18 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 643) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 370) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 116 099 006 - 107879362
|
||||
3 Spin_Up_Time PO---- 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1887
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 072 058 030 - 17263568758
|
||||
9 Power_On_Hours -O--CK 085 085 000 - 13655
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1397
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 098 000 - 42950328335
|
||||
189 High_Fly_Writes -O-RCK 077 077 000 - 23
|
||||
190 Airflow_Temperature_Cel -O---K 060 056 045 - 40 (Min/Max 37/41)
|
||||
194 Temperature_Celsius -O---K 040 044 000 - 40 (0 18 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 053 035 000 - 107879362
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 16404 (110 250 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 3489214790
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 3868380020
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2928 Device vendor specific log
|
||||
0xbd GPL,SL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 13354 -
|
||||
# 2 Short offline Completed without error 00% 13176 -
|
||||
# 3 Short offline Completed without error 00% 12882 -
|
||||
# 4 Short offline Completed without error 00% 12881 -
|
||||
# 5 Short offline Completed without error 00% 12880 -
|
||||
# 6 Short offline Completed without error 00% 12879 -
|
||||
# 7 Short offline Completed without error 00% 12878 -
|
||||
# 8 Short offline Completed without error 00% 12877 -
|
||||
# 9 Short offline Completed without error 00% 12876 -
|
||||
#10 Short offline Completed without error 00% 12875 -
|
||||
#11 Short offline Completed without error 00% 12874 -
|
||||
#12 Short offline Completed without error 00% 12874 -
|
||||
#13 Short offline Completed without error 00% 12869 -
|
||||
#14 Short offline Completed without error 00% 12868 -
|
||||
#15 Short offline Completed without error 00% 12867 -
|
||||
#16 Short offline Completed without error 00% 12866 -
|
||||
#17 Short offline Completed without error 00% 12865 -
|
||||
#18 Short offline Completed without error 00% 12864 -
|
||||
#19 Short offline Completed without error 00% 12863 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 40 Celsius
|
||||
Power Cycle Min/Max Temperature: 37/41 Celsius
|
||||
Lifetime Min/Max Temperature: 18/44 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (9)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
191
HDD/Seagate/ST3150/ST31500541AS/277F6E5C9C81
Normal file
191
HDD/Seagate/ST3150/ST31500541AS/277F6E5C9C81
Normal file
@@ -0,0 +1,191 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda LP
|
||||
Device Model: ST31500541AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC35
|
||||
User Capacity: 1,500,301,910,016 bytes [1.50 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Wed Jun 3 11:18:19 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 633) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 296) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 118 099 006 - 188125803
|
||||
3 Spin_Up_Time PO---- 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 098 098 020 - 2155
|
||||
5 Reallocated_Sector_Ct PO--CK 097 097 036 - 150
|
||||
7 Seek_Error_Rate POSR-- 072 060 030 - 21565573334
|
||||
9 Power_On_Hours -O--CK 081 081 000 - 17136
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1803
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 30065229835
|
||||
189 High_Fly_Writes -O-RCK 091 091 000 - 9
|
||||
190 Airflow_Temperature_Cel -O---K 058 054 045 - 42 (Min/Max 39/42)
|
||||
194 Temperature_Celsius -O---K 042 046 000 - 42 (0 19 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 037 021 000 - 188125803
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 2
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 19331 (186 8 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 1866739352
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 2514712788
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2928 Device vendor specific log
|
||||
0xbd GPL,SL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 16834 -
|
||||
# 2 Short offline Completed without error 00% 16387 -
|
||||
# 3 Short offline Completed without error 00% 16386 -
|
||||
# 4 Short offline Completed without error 00% 16385 -
|
||||
# 5 Short offline Completed without error 00% 16384 -
|
||||
# 6 Short offline Completed without error 00% 16383 -
|
||||
# 7 Short offline Completed without error 00% 16382 -
|
||||
# 8 Short offline Completed without error 00% 16381 -
|
||||
# 9 Short offline Completed without error 00% 16380 -
|
||||
#10 Short offline Completed without error 00% 16379 -
|
||||
#11 Short offline Completed without error 00% 16379 -
|
||||
#12 Short offline Completed without error 00% 16374 -
|
||||
#13 Short offline Completed without error 00% 16373 -
|
||||
#14 Short offline Completed without error 00% 16372 -
|
||||
#15 Short offline Completed without error 00% 16371 -
|
||||
#16 Short offline Completed without error 00% 16370 -
|
||||
#17 Short offline Completed without error 00% 16369 -
|
||||
#18 Short offline Completed without error 00% 16368 -
|
||||
#19 Short offline Completed without error 00% 16367 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 42 Celsius
|
||||
Power Cycle Min/Max Temperature: 39/42 Celsius
|
||||
Lifetime Min/Max Temperature: 19/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (90)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
191
HDD/Seagate/ST3150/ST31500541AS/33051BA0B30C
Normal file
191
HDD/Seagate/ST3150/ST31500541AS/33051BA0B30C
Normal file
@@ -0,0 +1,191 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda LP
|
||||
Device Model: ST31500541AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC35
|
||||
User Capacity: 1,500,301,910,016 bytes [1.50 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Wed Jun 3 11:18:18 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 623) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 290) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 108 099 006 - 15186533
|
||||
3 Spin_Up_Time PO---- 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 2042
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 073 057 030 - 12963328875
|
||||
9 Power_On_Hours -O--CK 083 083 000 - 15377
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1630
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 42950328334
|
||||
189 High_Fly_Writes -O-RCK 097 097 000 - 3
|
||||
190 Airflow_Temperature_Cel -O---K 058 054 045 - 42 (Min/Max 39/43)
|
||||
194 Temperature_Celsius -O---K 042 046 000 - 42 (0 19 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 031 025 000 - 15186533
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 16183 (186 241 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 2948847074
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 2991238184
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2928 Device vendor specific log
|
||||
0xbd GPL,SL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 15074 -
|
||||
# 2 Short offline Aborted by host 90% 15070 -
|
||||
# 3 Short offline Completed without error 00% 14605 -
|
||||
# 4 Short offline Completed without error 00% 14604 -
|
||||
# 5 Short offline Completed without error 00% 14603 -
|
||||
# 6 Short offline Completed without error 00% 14602 -
|
||||
# 7 Short offline Completed without error 00% 14601 -
|
||||
# 8 Short offline Completed without error 00% 14600 -
|
||||
# 9 Short offline Completed without error 00% 14599 -
|
||||
#10 Short offline Completed without error 00% 14598 -
|
||||
#11 Short offline Completed without error 00% 14597 -
|
||||
#12 Short offline Completed without error 00% 14596 -
|
||||
#13 Short offline Completed without error 00% 14592 -
|
||||
#14 Short offline Completed without error 00% 14591 -
|
||||
#15 Short offline Completed without error 00% 14590 -
|
||||
#16 Short offline Completed without error 00% 14589 -
|
||||
#17 Short offline Completed without error 00% 14588 -
|
||||
#18 Short offline Completed without error 00% 14587 -
|
||||
#19 Short offline Completed without error 00% 14586 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 42 Celsius
|
||||
Power Cycle Min/Max Temperature: 39/43 Celsius
|
||||
Lifetime Min/Max Temperature: 19/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (56)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
191
HDD/Seagate/ST3150/ST31500541AS/8728B45F9B6C
Normal file
191
HDD/Seagate/ST3150/ST31500541AS/8728B45F9B6C
Normal file
@@ -0,0 +1,191 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda LP
|
||||
Device Model: ST31500541AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC35
|
||||
User Capacity: 1,500,301,910,016 bytes [1.50 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Wed Jun 3 11:18:18 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 663) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 399) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 117 099 006 - 160511373
|
||||
3 Spin_Up_Time PO---- 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1945
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 071 060 030 - 21549620099
|
||||
9 Power_On_Hours -O--CK 082 082 000 - 15923
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1594
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 098 000 - 47245426705
|
||||
189 High_Fly_Writes -O-RCK 080 080 000 - 20
|
||||
190 Airflow_Temperature_Cel -O---K 059 054 045 - 41 (Min/Max 38/42)
|
||||
194 Temperature_Celsius -O---K 041 046 000 - 41 (0 19 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 051 033 000 - 160511373
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 16567 (99 14 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 196276759
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 505058063
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2928 Device vendor specific log
|
||||
0xbd GPL,SL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 15622 -
|
||||
# 2 Short offline Completed without error 00% 15151 -
|
||||
# 3 Short offline Completed without error 00% 15150 -
|
||||
# 4 Short offline Completed without error 00% 15149 -
|
||||
# 5 Short offline Completed without error 00% 15148 -
|
||||
# 6 Short offline Completed without error 00% 15147 -
|
||||
# 7 Short offline Completed without error 00% 15146 -
|
||||
# 8 Short offline Completed without error 00% 15145 -
|
||||
# 9 Short offline Completed without error 00% 15144 -
|
||||
#10 Short offline Completed without error 00% 15143 -
|
||||
#11 Short offline Completed without error 00% 15142 -
|
||||
#12 Short offline Completed without error 00% 15138 -
|
||||
#13 Short offline Completed without error 00% 15137 -
|
||||
#14 Short offline Completed without error 00% 15136 -
|
||||
#15 Short offline Completed without error 00% 15135 -
|
||||
#16 Short offline Completed without error 00% 15134 -
|
||||
#17 Short offline Completed without error 00% 15133 -
|
||||
#18 Short offline Completed without error 00% 15132 -
|
||||
#19 Short offline Completed without error 00% 15131 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/42 Celsius
|
||||
Lifetime Min/Max Temperature: 19/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (100)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
197
HDD/Seagate/ST3150/ST31500541AS/DB6D003CA022
Normal file
197
HDD/Seagate/ST3150/ST31500541AS/DB6D003CA022
Normal file
@@ -0,0 +1,197 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda LP
|
||||
Device Model: ST31500541AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC34
|
||||
User Capacity: 1,500,301,910,016 bytes [1.50 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Wed Jun 3 11:18:19 2020 PDT
|
||||
|
||||
==> WARNING: A firmware update for this drive may be available,
|
||||
see the following Seagate web pages:
|
||||
http://knowledge.seagate.com/articles/en_US/FAQ/207931en
|
||||
http://knowledge.seagate.com/articles/en_US/FAQ/213915en
|
||||
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 653) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 378) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 118 099 006 - 183866909
|
||||
3 Spin_Up_Time PO---- 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 093 093 020 - 7478
|
||||
5 Reallocated_Sector_Ct PO--CK 090 090 036 - 442
|
||||
7 Seek_Error_Rate POSR-- 063 057 030 - 128921092761
|
||||
9 Power_On_Hours -O--CK 082 082 000 - 15842
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 037 020 - 1909
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 094 000 - 111670919249
|
||||
189 High_Fly_Writes -O-RCK 086 086 000 - 14
|
||||
190 Airflow_Temperature_Cel -O---K 057 051 045 - 43 (Min/Max 40/43 #1)
|
||||
194 Temperature_Celsius -O---K 043 049 000 - 43 (0 13 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 053 036 000 - 183866909
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 2525
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 17267 (183 223 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 1286708435
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1261885333
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2928 Device vendor specific log
|
||||
0xbd GPL,SL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 15541 -
|
||||
# 2 Short offline Completed without error 00% 14925 -
|
||||
# 3 Extended offline Completed without error 00% 14912 -
|
||||
# 4 Short offline Completed without error 00% 14903 -
|
||||
# 5 Short offline Completed without error 00% 14902 -
|
||||
# 6 Short offline Completed without error 00% 14901 -
|
||||
# 7 Short offline Completed without error 00% 14900 -
|
||||
# 8 Short offline Completed without error 00% 14899 -
|
||||
# 9 Short offline Completed without error 00% 14899 -
|
||||
#10 Short offline Completed without error 00% 14897 -
|
||||
#11 Short offline Completed without error 00% 14897 -
|
||||
#12 Short offline Completed without error 00% 14896 -
|
||||
#13 Short offline Completed without error 00% 14895 -
|
||||
#14 Short offline Completed without error 00% 14894 -
|
||||
#15 Short offline Completed without error 00% 14893 -
|
||||
#16 Short offline Completed without error 00% 14892 -
|
||||
#17 Short offline Completed without error 00% 14891 -
|
||||
#18 Short offline Completed without error 00% 14890 -
|
||||
#19 Short offline Completed without error 00% 14889 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 43 Celsius
|
||||
Power Cycle Min/Max Temperature: 40/43 Celsius
|
||||
Lifetime Min/Max Temperature: 13/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (116)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 13 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
214
HDD/Seagate/ST320/ST320LM001 HN-M320MBB/083E66BA3525
Normal file
214
HDD/Seagate/ST320/ST320LM001 HN-M320MBB/083E66BA3525
Normal file
@@ -0,0 +1,214 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Samsung SpinPoint M8 (AF)
|
||||
Device Model: ST320LM001 HN-M320MBB
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0004cf ...
|
||||
Firmware Version: 2AR10001
|
||||
User Capacity: 320,072,933,376 bytes [320 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Jun 4 16:07:11 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 0 (vendor specific), recommended: 254
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 5280) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 88) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 0
|
||||
2 Throughput_Performance -OS--K 056 056 000 - 4759
|
||||
3 Spin_Up_Time PO---K 091 091 025 - 2865
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1469
|
||||
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
|
||||
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
|
||||
8 Seek_Time_Performance --S--K 252 252 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 24457
|
||||
10 Spin_Retry_Count -O--CK 252 252 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 488
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1529
|
||||
191 G-Sense_Error_Rate -O---K 100 100 000 - 1
|
||||
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
|
||||
194 Temperature_Celsius -O---- 064 047 000 - 35 (Min/Max 16/53)
|
||||
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 252 252 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 252 252 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 4
|
||||
223 Load_Retry_Count -O--CK 100 100 000 - 488
|
||||
225 Load_Cycle_Count -O--CK 007 007 000 - 939953
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 2 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xc0-0xdf GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (2 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 24443 -
|
||||
# 2 Short offline Completed without error 00% 24419 -
|
||||
# 3 Short offline Completed without error 00% 24395 -
|
||||
# 4 Short offline Completed without error 00% 24371 -
|
||||
# 5 Short offline Completed without error 00% 24347 -
|
||||
# 6 Extended offline Completed without error 00% 24326 -
|
||||
# 7 Short offline Completed without error 00% 24323 -
|
||||
# 8 Short offline Completed without error 00% 24299 -
|
||||
# 9 Short offline Completed without error 00% 24275 -
|
||||
#10 Short offline Completed without error 00% 24251 -
|
||||
#11 Short offline Completed without error 00% 24227 -
|
||||
#12 Short offline Completed without error 00% 24203 -
|
||||
#13 Short offline Completed without error 00% 24179 -
|
||||
#14 Extended offline Completed without error 00% 24158 -
|
||||
#15 Short offline Completed without error 00% 24155 -
|
||||
#16 Short offline Completed without error 00% 24131 -
|
||||
#17 Short offline Completed without error 00% 24107 -
|
||||
#18 Short offline Completed without error 00% 24083 -
|
||||
#19 Short offline Completed without error 00% 24059 -
|
||||
#20 Short offline Completed without error 00% 24035 -
|
||||
#21 Short offline Completed without error 00% 24011 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Completed [00% left] (0-65535)
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/43 Celsius
|
||||
Lifetime Min/Max Temperature: 18/66 Celsius
|
||||
Specified Max Operating Temperature: 80 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 5 minutes
|
||||
Temperature Logging Interval: 5 minutes
|
||||
Min/Max recommended Temperature: -5/80 Celsius
|
||||
Min/Max Temperature Limit: -10/85 Celsius
|
||||
Temperature History Size (Index): 128 (121)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0002 4 0 R_ERR response for data FIS
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 4 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 19 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x8e00 4 0 Vendor specific
|
||||
0x8e01 4 0 Vendor specific
|
||||
0x8e02 4 0 Vendor specific
|
||||
0x8e03 4 0 Vendor specific
|
||||
0x8e04 4 0 Vendor specific
|
||||
0x8e05 4 0 Vendor specific
|
||||
0x8e06 4 0 Vendor specific
|
||||
0x8e07 4 0 Vendor specific
|
||||
0x8e08 4 0 Vendor specific
|
||||
0x8e09 4 0 Vendor specific
|
||||
0x8e0a 4 0 Vendor specific
|
||||
0x8e0b 4 0 Vendor specific
|
||||
0x8e0c 4 0 Vendor specific
|
||||
0x8e0d 4 0 Vendor specific
|
||||
0x8e0e 4 0 Vendor specific
|
||||
0x8e0f 4 0 Vendor specific
|
||||
0x8e10 4 0 Vendor specific
|
||||
0x8e11 4 0 Vendor specific
|
||||
|
||||
|
||||
|
214
HDD/Seagate/ST320/ST320LM001 HN-M320MBB/DC43497ADB01
Normal file
214
HDD/Seagate/ST320/ST320LM001 HN-M320MBB/DC43497ADB01
Normal file
@@ -0,0 +1,214 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Samsung SpinPoint M8 (AF)
|
||||
Device Model: ST320LM001 HN-M320MBB
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0004cf ...
|
||||
Firmware Version: 2AR10001
|
||||
User Capacity: 320,072,933,376 bytes [320 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Jun 4 16:07:10 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 0 (vendor specific), recommended: 254
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 3480) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 58) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 2
|
||||
2 Throughput_Performance -OS--K 056 056 000 - 3163
|
||||
3 Spin_Up_Time PO---K 091 091 025 - 2863
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 726
|
||||
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
|
||||
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
|
||||
8 Seek_Time_Performance --S--K 252 252 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 32643
|
||||
10 Spin_Retry_Count -O--CK 252 252 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 096 096 000 - 4966
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 722
|
||||
191 G-Sense_Error_Rate -O---K 100 100 000 - 27
|
||||
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
|
||||
194 Temperature_Celsius -O---- 064 052 000 - 34 (Min/Max 17/51)
|
||||
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 252 252 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 252 252 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 33
|
||||
223 Load_Retry_Count -O--CK 096 096 000 - 4966
|
||||
225 Load_Cycle_Count -O--CK 018 018 000 - 833951
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 2 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xc0-0xdf GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (2 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 32629 -
|
||||
# 2 Short offline Completed without error 00% 32605 -
|
||||
# 3 Short offline Completed without error 00% 32581 -
|
||||
# 4 Short offline Completed without error 00% 32557 -
|
||||
# 5 Short offline Completed without error 00% 32533 -
|
||||
# 6 Extended offline Completed without error 00% 32511 -
|
||||
# 7 Short offline Completed without error 00% 32509 -
|
||||
# 8 Short offline Completed without error 00% 32485 -
|
||||
# 9 Short offline Completed without error 00% 32461 -
|
||||
#10 Short offline Completed without error 00% 32437 -
|
||||
#11 Short offline Completed without error 00% 32413 -
|
||||
#12 Short offline Completed without error 00% 32389 -
|
||||
#13 Short offline Completed without error 00% 32365 -
|
||||
#14 Extended offline Completed without error 00% 32343 -
|
||||
#15 Short offline Completed without error 00% 32341 -
|
||||
#16 Short offline Completed without error 00% 32317 -
|
||||
#17 Short offline Completed without error 00% 32293 -
|
||||
#18 Short offline Completed without error 00% 32269 -
|
||||
#19 Short offline Completed without error 00% 32245 -
|
||||
#20 Short offline Completed without error 00% 32221 -
|
||||
#21 Short offline Completed without error 00% 32197 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Completed [00% left] (0-65535)
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/42 Celsius
|
||||
Lifetime Min/Max Temperature: 17/63 Celsius
|
||||
Specified Max Operating Temperature: 80 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 5 minutes
|
||||
Temperature Logging Interval: 5 minutes
|
||||
Min/Max recommended Temperature: -5/80 Celsius
|
||||
Min/Max Temperature Limit: -10/85 Celsius
|
||||
Temperature History Size (Index): 128 (118)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0002 4 0 R_ERR response for data FIS
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 4 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 19 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x8e00 4 0 Vendor specific
|
||||
0x8e01 4 0 Vendor specific
|
||||
0x8e02 4 0 Vendor specific
|
||||
0x8e03 4 0 Vendor specific
|
||||
0x8e04 4 0 Vendor specific
|
||||
0x8e05 4 0 Vendor specific
|
||||
0x8e06 4 0 Vendor specific
|
||||
0x8e07 4 0 Vendor specific
|
||||
0x8e08 4 0 Vendor specific
|
||||
0x8e09 4 0 Vendor specific
|
||||
0x8e0a 4 0 Vendor specific
|
||||
0x8e0b 4 0 Vendor specific
|
||||
0x8e0c 4 0 Vendor specific
|
||||
0x8e0d 4 0 Vendor specific
|
||||
0x8e0e 4 0 Vendor specific
|
||||
0x8e0f 4 0 Vendor specific
|
||||
0x8e10 4 0 Vendor specific
|
||||
0x8e11 4 0 Vendor specific
|
||||
|
||||
|
||||
|
293
HDD/Seagate/ST3320/ST3320620AS/D6417A44BE7A
Normal file
293
HDD/Seagate/ST3320/ST3320620AS/D6417A44BE7A
Normal file
@@ -0,0 +1,293 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.10
|
||||
Device Model: ST3320620AS
|
||||
Serial Number: --
|
||||
Firmware Version: 3.AAK
|
||||
User Capacity: 320,071,851,520 bytes [320 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Tue Jun 2 22:17:52 2020 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 33) The self-test routine was interrupted
|
||||
by the host with a hard or soft reset.
|
||||
Total time to complete Offline
|
||||
data collection: ( 430) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 115) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 104 091 006 - 7167037
|
||||
3 Spin_Up_Time PO---- 095 095 000 - 0
|
||||
4 Start_Stop_Count -O--CK 085 085 020 - 16100
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 24
|
||||
7 Seek_Error_Rate POSR-- 059 048 030 - 1237172762142
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 7439
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 085 085 020 - 16276
|
||||
187 Reported_Uncorrect -O--CK 001 001 000 - 123
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 061 050 045 - 39 (Min/Max 31/39)
|
||||
194 Temperature_Celsius -O---K 039 050 000 - 39 (0 15 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 084 060 000 - 215897900
|
||||
197 Current_Pending_Sector -O--C- 100 001 000 - 12
|
||||
198 Offline_Uncorrectable ----C- 100 001 000 - 12
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 188 000 - 108
|
||||
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
|
||||
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL,SL VS 1 Device vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL,SL VS 101 Device vendor specific log
|
||||
0xa8 GPL,SL VS 20 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
0xff GPL - 23040 Reserved
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
Device Error Count: 416 (device log contains only the most recent 20 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 416 [15] occurred at disk power-on lifetime: 7389 hours (307 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 00 00 0e 8a 8f 24 8f e0 00 Error: ICRC, ABRT at LBA = 0xe8a8f248f = 62454178959
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 10 00 1b 93 00 9f d8 e0 00 08:30:51.740 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 93 00 9f b8 e0 00 08:30:51.739 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 93 00 9f 98 e0 00 08:30:51.739 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 93 00 9f 78 e0 00 08:30:51.739 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 93 00 9f 58 e0 00 08:30:51.739 READ DMA EXT
|
||||
|
||||
Error 415 [14] occurred at disk power-on lifetime: 7389 hours (307 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 00 00 0e 8a 8f 24 8f e0 00 Error: ICRC, ABRT at LBA = 0xe8a8f248f = 62454178959
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 20 00 1b 90 00 9f b8 e0 00 08:30:50.415 READ DMA EXT
|
||||
25 00 00 00 18 00 1b 90 00 9f 00 e0 00 08:30:50.415 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 8f 00 9f e0 e0 00 08:30:50.415 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 8f 00 9f c0 e0 00 08:30:50.415 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 8f 00 9f a0 e0 00 08:30:50.414 READ DMA EXT
|
||||
|
||||
Error 414 [13] occurred at disk power-on lifetime: 7389 hours (307 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 0f 00 0e 8a 8f 24 8f e0 00 Error: ICRC, ABRT 15 sectors at LBA = 0xe8a8f248f = 62454178959
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 20 00 1b 8e 00 9f c0 e0 00 08:30:46.416 READ DMA EXT
|
||||
c6 00 00 00 10 00 00 00 00 00 00 e0 00 08:30:46.415 SET MULTIPLE MODE
|
||||
91 00 00 00 3f 00 0f 00 00 00 00 ef 00 08:30:46.415 INITIALIZE DEVICE PARAMETERS [OBS-6]
|
||||
10 00 00 01 00 00 00 00 00 00 00 e0 00 08:30:46.415 RECALIBRATE [OBS-4]
|
||||
00 00 00 00 20 00 1b 8e 00 9f c0 00 00 08:30:49.067 NOP [Abort queued commands]
|
||||
|
||||
Error 413 [12] occurred at disk power-on lifetime: 7389 hours (307 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 0f 00 0e 8a 8f 24 8f e0 00 Error: ICRC, ABRT 15 sectors at LBA = 0xe8a8f248f = 62454178959
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 20 00 1b 8e 00 9f c0 e0 00 08:30:46.416 READ DMA EXT
|
||||
c6 00 00 00 10 00 00 00 00 00 00 e0 00 08:30:46.415 SET MULTIPLE MODE
|
||||
91 00 00 00 3f 00 0f 00 00 00 00 ef 00 08:30:46.415 INITIALIZE DEVICE PARAMETERS [OBS-6]
|
||||
10 00 00 01 00 00 00 00 00 00 00 e0 00 08:30:46.415 RECALIBRATE [OBS-4]
|
||||
00 00 00 00 20 00 1b 8e 00 9f c0 00 00 08:30:46.414 NOP [Abort queued commands]
|
||||
|
||||
Error 412 [11] occurred at disk power-on lifetime: 7389 hours (307 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 00 00 0e 8a 8f 24 8f e0 00 Error: ICRC, ABRT at LBA = 0xe8a8f248f = 62454178959
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 10 00 1b 93 00 9f d8 e0 00 08:30:51.740 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 93 00 9f b8 e0 00 08:30:51.739 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 93 00 9f 98 e0 00 08:30:51.739 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 93 00 9f 78 e0 00 08:30:51.739 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 93 00 9f 58 e0 00 08:30:51.739 READ DMA EXT
|
||||
|
||||
Error 411 [10] occurred at disk power-on lifetime: 7389 hours (307 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 00 00 0e 8a 8f 24 8f e0 00 Error: ICRC, ABRT at LBA = 0xe8a8f248f = 62454178959
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 20 00 1b 90 00 9f b8 e0 00 08:30:50.415 READ DMA EXT
|
||||
25 00 00 00 18 00 1b 90 00 9f 00 e0 00 08:30:50.415 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 8f 00 9f e0 e0 00 08:30:50.415 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 8f 00 9f c0 e0 00 08:30:50.415 READ DMA EXT
|
||||
25 00 00 00 20 00 1b 8f 00 9f a0 e0 00 08:30:50.414 READ DMA EXT
|
||||
|
||||
Error 410 [9] occurred at disk power-on lifetime: 7389 hours (307 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 0f 00 0e 8a 8f 24 8f e0 00 Error: ICRC, ABRT 15 sectors at LBA = 0xe8a8f248f = 62454178959
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 20 00 1b 8e 00 9f c0 e0 00 08:30:46.416 READ DMA EXT
|
||||
c6 00 00 00 10 00 00 00 00 00 00 e0 00 08:30:46.415 SET MULTIPLE MODE
|
||||
91 00 00 00 3f 00 0f 00 00 00 00 ef 00 08:30:46.415 INITIALIZE DEVICE PARAMETERS [OBS-6]
|
||||
10 00 00 01 00 00 00 00 00 00 00 e0 00 08:30:46.415 RECALIBRATE [OBS-4]
|
||||
00 00 00 00 20 00 1b 8e 00 9f c0 00 00 08:30:49.067 NOP [Abort queued commands]
|
||||
|
||||
Error 409 [8] occurred at disk power-on lifetime: 7389 hours (307 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 0f 00 0e 8a 8f 24 8f e0 00 Error: ICRC, ABRT 15 sectors at LBA = 0xe8a8f248f = 62454178959
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 20 00 1b 8e 00 9f c0 e0 00 08:30:46.416 READ DMA EXT
|
||||
c6 00 00 00 10 00 00 00 00 00 00 e0 00 08:30:46.415 SET MULTIPLE MODE
|
||||
91 00 00 00 3f 00 0f 00 00 00 00 ef 00 08:30:46.415 INITIALIZE DEVICE PARAMETERS [OBS-6]
|
||||
10 00 00 01 00 00 00 00 00 00 00 e0 00 08:30:46.415 RECALIBRATE [OBS-4]
|
||||
00 00 00 00 20 00 1b 8e 00 9f c0 00 00 08:30:46.414 NOP [Abort queued commands]
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Interrupted (host reset) 10% 2856 -
|
||||
# 2 Short offline Completed without error 00% 2219 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 20 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
188
HDD/Seagate/ST4000/ST4000DM000-1F2168/8E0A72698B10
Normal file
188
HDD/Seagate/ST4000/ST4000DM000-1F2168/8E0A72698B10
Normal file
@@ -0,0 +1,188 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Desktop HDD.15
|
||||
Device Model: ST4000DM000-1F2168
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC52
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Jun 5 10:59:37 2020 -03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 1 (minimum power consumption with standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 602) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 522) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 111 099 006 - 38986504
|
||||
3 Spin_Up_Time PO---- 091 091 000 - 0
|
||||
4 Start_Stop_Count -O--CK 093 093 020 - 7983
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 084 060 030 - 4592302509
|
||||
9 Power_On_Hours -O--CK 059 059 000 - 36341
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 401
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0 0 0
|
||||
189 High_Fly_Writes -O-RCK 049 049 000 - 51
|
||||
190 Airflow_Temperature_Cel -O---K 065 048 045 - 35 (Min/Max 25/42 #1)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 365
|
||||
193 Load_Cycle_Count -O--CK 094 094 000 - 12820
|
||||
194 Temperature_Celsius -O---K 035 052 000 - 35 (128 0 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 21
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 31772h+52m+15.486s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 197478192263
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 428230833773
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 1223 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 1223 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 36330 -
|
||||
# 2 Short offline Completed without error 00% 36306 -
|
||||
# 3 Short offline Completed without error 00% 36282 -
|
||||
# 4 Short offline Completed without error 00% 36258 -
|
||||
# 5 Short offline Completed without error 00% 36234 -
|
||||
# 6 Extended offline Completed without error 00% 36218 -
|
||||
# 7 Short offline Completed without error 00% 36186 -
|
||||
# 8 Short offline Completed without error 00% 36162 -
|
||||
# 9 Short offline Completed without error 00% 36138 -
|
||||
#10 Short offline Completed without error 00% 36114 -
|
||||
#11 Short offline Completed without error 00% 36090 -
|
||||
#12 Short offline Completed without error 00% 36066 -
|
||||
#13 Extended offline Completed without error 00% 36050 -
|
||||
#14 Short offline Completed without error 00% 36018 -
|
||||
#15 Short offline Completed without error 00% 35995 -
|
||||
#16 Short offline Completed without error 00% 35971 -
|
||||
#17 Short offline Completed without error 00% 35947 -
|
||||
#18 Short offline Completed without error 00% 35923 -
|
||||
#19 Short offline Completed without error 00% 35899 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/42 Celsius
|
||||
Lifetime Min/Max Temperature: 16/52 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 42 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
212
HDD/Seagate/ST4000/ST4000DM000-1F2168/B7C3F9A50401
Normal file
212
HDD/Seagate/ST4000/ST4000DM000-1F2168/B7C3F9A50401
Normal file
@@ -0,0 +1,212 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Desktop HDD.15
|
||||
Device Model: ST4000DM000-1F2168
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC54
|
||||
User Capacity: 4,000,785,948,160 bytes [4.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Jun 5 10:59:29 2020 -03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 1 (minimum power consumption with standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 107) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 498) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 117 099 006 - 164474952
|
||||
3 Spin_Up_Time PO---- 093 091 000 - 0
|
||||
4 Start_Stop_Count -O--CK 093 093 020 - 7458
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 074 060 030 - 27533035
|
||||
9 Power_On_Hours -O--CK 083 083 000 - 15299
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 115
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0 0 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 067 050 045 - 33 (Min/Max 24/41)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 049 049 000 - 103776
|
||||
194 Temperature_Celsius -O---K 033 050 000 - 33 (0 13 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 14624h+42m+17.011s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 36328411443
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 122375282338
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 1223 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 1223 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 15289 -
|
||||
# 2 Short offline Completed without error 00% 15265 -
|
||||
# 3 Short offline Completed without error 00% 15241 -
|
||||
# 4 Short offline Completed without error 00% 15216 -
|
||||
# 5 Short offline Completed without error 00% 15192 -
|
||||
# 6 Extended offline Completed without error 00% 15176 -
|
||||
# 7 Short offline Completed without error 00% 15144 -
|
||||
# 8 Short offline Completed without error 00% 15120 -
|
||||
# 9 Short offline Completed without error 00% 15096 -
|
||||
#10 Short offline Completed without error 00% 15072 -
|
||||
#11 Short offline Completed without error 00% 15048 -
|
||||
#12 Short offline Completed without error 00% 15024 -
|
||||
#13 Extended offline Completed without error 00% 15008 -
|
||||
#14 Short offline Completed without error 00% 14976 -
|
||||
#15 Short offline Completed without error 00% 14953 -
|
||||
#16 Short offline Completed without error 00% 14929 -
|
||||
#17 Short offline Completed without error 00% 14905 -
|
||||
#18 Short offline Completed without error 00% 14881 -
|
||||
#19 Short offline Completed without error 00% 14857 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/41 Celsius
|
||||
Lifetime Min/Max Temperature: 13/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 115 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 15299 --- Power-on Hours
|
||||
0x01 0x018 6 36753260229 --- Logical Sectors Written
|
||||
0x01 0x020 6 295695755 --- Number of Write Commands
|
||||
0x01 0x028 6 30237899437 --- Logical Sectors Read
|
||||
0x01 0x030 6 142954334 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 12437 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 4024 --- Head Flying Hours
|
||||
0x03 0x018 4 103776 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 42 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
223
HDD/Seagate/ST4000/ST4000LM024-2AN17V/8BF69C0EDD66
Normal file
223
HDD/Seagate/ST4000/ST4000LM024-2AN17V/8BF69C0EDD66
Normal file
@@ -0,0 +1,223 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 2.5 5400
|
||||
Device Model: ST4000LM024-2AN17V
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5526 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Jun 9 20:50:31 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 709) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x30a5) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 077 064 006 - 51065632
|
||||
3 Spin_Up_Time PO---- 097 095 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 119
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 084 060 045 - 273154255
|
||||
9 Power_On_Hours -O--CK 085 085 000 - 13897 (117 44 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 60
|
||||
183 SATA_Downshift_Count -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 053 033 040 Past 47 (Min/Max 46/63 #4793)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 8
|
||||
193 Load_Cycle_Count -O--CK 098 098 000 - 4704
|
||||
194 Temperature_Celsius -O---K 047 067 000 - 47 (0 18 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 077 064 000 - 51065632
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 1989 (29 123 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 19413151810
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 19062595998
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xd1 GPL VS 168 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 47 Celsius
|
||||
Power Cycle Min/Max Temperature: 45/64 Celsius
|
||||
Lifetime Min/Max Temperature: 18/67 Celsius
|
||||
Under/Over Temperature Limit Count: 0/337
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (22)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 60 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 13897 --- Power-on Hours
|
||||
0x01 0x018 6 19412538082 --- Logical Sectors Written
|
||||
0x01 0x020 6 216910367 --- Number of Write Commands
|
||||
0x01 0x028 6 19092510950 --- Logical Sectors Read
|
||||
0x01 0x030 6 119953522 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 13896 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 0 --- Head Flying Hours
|
||||
0x03 0x018 4 4705 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 10 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 47 --- Current Temperature
|
||||
0x05 0x010 1 48 --- Average Short Term Temperature
|
||||
0x05 0x018 1 50 --- Average Long Term Temperature
|
||||
0x05 0x020 1 67 --- Highest Temperature
|
||||
0x05 0x028 1 25 --- Lowest Temperature
|
||||
0x05 0x030 1 65 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 33 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 56 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 47 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 254680 --- Time in Over-Temperature
|
||||
0x05 0x058 1 55 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 13 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
222
HDD/Seagate/ST4000/ST4000VN008-2DR166/3F11CF2DDCA0
Normal file
222
HDD/Seagate/ST4000/ST4000VN008-2DR166/3F11CF2DDCA0
Normal file
@@ -0,0 +1,222 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate IronWolf
|
||||
Device Model: ST4000VN008-2DR166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5980 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jun 2 06:35:02 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 591) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 661) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 080 075 044 - 89905609
|
||||
3 Spin_Up_Time PO---- 093 093 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 40
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 063 060 045 - 2077523
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 737 (203 244 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 40
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 068 065 040 - 32 (Min/Max 32/34)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 4
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 312
|
||||
194 Temperature_Celsius -O---K 032 040 000 - 32 (0 22 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 15 (198 52 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 63236744
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 26668865
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 136 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/36 Celsius
|
||||
Lifetime Min/Max Temperature: 22/36 Celsius
|
||||
Under/Over Temperature Limit Count: 0/706
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (21)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 40 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 737 --- Power-on Hours
|
||||
0x01 0x018 6 63236744 --- Logical Sectors Written
|
||||
0x01 0x020 6 586325 --- Number of Write Commands
|
||||
0x01 0x028 6 26668707 --- Logical Sectors Read
|
||||
0x01 0x030 6 249989 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 3023707279 N-- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 3023706547 N-- Head Flying Hours
|
||||
0x03 0x018 4 312 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 5 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x010 1 32 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 36 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 35 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 30 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 103 --- Number of Hardware Resets
|
||||
0x06 0x010 4 48 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
103
HDD/Seagate/ST500/ST500LT012-9WS142/41DB4691AB7C
Normal file
103
HDD/Seagate/ST500/ST500LT012-9WS142/41DB4691AB7C
Normal file
@@ -0,0 +1,103 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [NetBSD 9.0 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Laptop HDD
|
||||
Device Model: ST500LT012-9WS142
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001LVM1
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Jun 3 12:38:49 2020 IST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 103) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1031) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x000f 118 099 034 Pre-fail Always - 181394440
|
||||
3 Spin_Up_Time 0x0003 099 099 000 Pre-fail Always - 0
|
||||
4 Start_Stop_Count 0x0032 097 097 020 Old_age Always - 3957
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
|
||||
7 Seek_Error_Rate 0x000f 076 060 030 Pre-fail Always - 8677995024
|
||||
9 Power_On_Hours 0x0032 092 092 000 Old_age Always - 7108 (120 155 0)
|
||||
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
|
||||
12 Power_Cycle_Count 0x0032 097 097 020 Old_age Always - 3413
|
||||
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
|
||||
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
|
||||
188 Command_Timeout 0x0032 100 100 000 Old_age Always - 4295032834
|
||||
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0022 055 037 045 Old_age Always In_the_past 45 (Min/Max 39/45 #496)
|
||||
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 826
|
||||
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 161
|
||||
193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 264279
|
||||
194 Temperature_Celsius 0x0022 045 063 000 Old_age Always - 45 (0 18 0 0 0)
|
||||
196 Reallocated_Event_Count 0x000f 094 094 030 Pre-fail Always - 6042 (31269 0)
|
||||
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
|
||||
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
|
||||
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
|
||||
254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 5044 -
|
||||
# 2 Short offline Completed without error 00% 5041 -
|
||||
# 3 Short offline Completed without error 00% 5037 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
191
HDD/Seagate/ST500/ST500LT012-9WS142/E85C763737DA
Normal file
191
HDD/Seagate/ST500/ST500LT012-9WS142/E85C763737DA
Normal file
@@ -0,0 +1,191 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Laptop HDD
|
||||
Device Model: ST500LT012-9WS142
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001SDM1
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Jun 10 14:27:24 2020 IST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 104) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 118 099 006 - 173088272
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 096 096 020 - 4573
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 081 060 030 - 4420334111
|
||||
9 Power_On_Hours -O--CK 082 082 000 - 16352 (186 238 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 096 096 020 - 4558
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 065 053 045 - 35 (Min/Max 29/35)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 177
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 518
|
||||
193 Load_Cycle_Count -O--CK 019 019 000 - 163189
|
||||
194 Temperature_Celsius -O---K 035 047 000 - 35 (0 19 0 0 0)
|
||||
196 Reallocated_Event_Count POSR-- 082 082 030 - 15830 (21993 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 082 082 000 - 15830 (85 233 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 792065856
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 793264703
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 65 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2864 Device vendor specific log
|
||||
0xbd-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 15523 -
|
||||
# 2 Extended offline Completed without error 00% 14208 -
|
||||
# 3 Extended offline Completed without error 00% 13739 -
|
||||
# 4 Extended offline Completed without error 00% 13021 -
|
||||
# 5 Extended offline Completed without error 00% 12641 -
|
||||
# 6 Extended offline Completed without error 00% 11933 -
|
||||
# 7 Extended offline Completed without error 00% 11668 -
|
||||
# 8 Extended offline Completed without error 00% 11432 -
|
||||
# 9 Extended offline Completed without error 00% 11271 -
|
||||
#10 Extended offline Completed without error 00% 10789 -
|
||||
#11 Extended offline Completed without error 00% 9922 -
|
||||
#12 Extended offline Completed without error 00% 9625 -
|
||||
#13 Extended offline Completed without error 00% 9423 -
|
||||
#14 Extended offline Completed without error 00% 9013 -
|
||||
#15 Extended offline Completed without error 00% 8647 -
|
||||
#16 Extended offline Completed without error 00% 8445 -
|
||||
#17 Extended offline Completed without error 00% 8321 -
|
||||
#18 Extended offline Completed without error 00% 8128 -
|
||||
#19 Extended offline Completed without error 00% 7965 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/36 Celsius
|
||||
Lifetime Min/Max Temperature: 19/47 Celsius
|
||||
Specified Max Operating Temperature: 36 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 30 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (31)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
182
HDD/Seagate/ST5000/ST5000DM000-1FK178/28DC8DFE751A
Normal file
182
HDD/Seagate/ST5000/ST5000DM000-1FK178/28DC8DFE751A
Normal file
@@ -0,0 +1,182 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Desktop HDD.15
|
||||
Device Model: ST5000DM000-1FK178
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC49
|
||||
User Capacity: 5,000,981,078,016 bytes [5.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5980 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jun 9 02:35:50 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART Status not supported: Incomplete response, ATA output registers missing
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
Warning: This result is based on an Attribute check.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 96) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 627) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 116 100 006 - 103252184
|
||||
3 Spin_Up_Time PO---- 091 091 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 781
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 072 060 030 - 16693690
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 1840
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 110
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0 0 1
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 062 055 045 - 38 (Min/Max 23/39)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 1555
|
||||
194 Temperature_Celsius -O---K 038 045 000 - 38 (0 17 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 116 100 000 - 103252184
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 139h+26m+28.553s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 5104726195
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 61299571675
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa8 GPL,SL VS 136 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 8920 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65528 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc2 GPL,SL VS 56 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xc7 GPL,SL VS 8 Device vendor specific log
|
||||
0xd1 GPL,SL VS 64 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/39 Celsius
|
||||
Lifetime Min/Max Temperature: 17/45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (111)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 84 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
225
HDD/Seagate/ST5000/ST5000LM000-2AN170/1788BC895C60
Normal file
225
HDD/Seagate/ST5000/ST5000LM000-2AN170/1788BC895C60
Normal file
@@ -0,0 +1,225 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 2.5 5400
|
||||
Device Model: ST5000LM000-2AN170
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001
|
||||
User Capacity: 5,000,981,078,016 bytes [5.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5526 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jun 9 20:47:38 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 831) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x30a5) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 074 064 006 - 23279961
|
||||
3 Spin_Up_Time PO---- 100 096 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 160
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 085 060 045 - 335835491
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 11328 (102 33 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 160
|
||||
183 SATA_Downshift_Count -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 063 038 040 Past 37 (Min/Max 32/55 #45)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 105
|
||||
193 Load_Cycle_Count -O--CK 086 086 000 - 29346
|
||||
194 Temperature_Celsius -O---K 037 062 000 - 37 (0 17 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 074 064 000 - 23279961
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 2846 (228 239 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 29880558393
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 118711336417
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xd1 GPL VS 168 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/55 Celsius
|
||||
Lifetime Min/Max Temperature: 17/62 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (37)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 160 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 11328 --- Power-on Hours
|
||||
0x01 0x018 6 29907047761 --- Logical Sectors Written
|
||||
0x01 0x020 6 146180982 --- Number of Write Commands
|
||||
0x01 0x028 6 118765625043 --- Logical Sectors Read
|
||||
0x01 0x030 6 673128839 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 11297 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 0 --- Head Flying Hours
|
||||
0x03 0x018 4 29346 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 106 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x010 1 39 --- Average Short Term Temperature
|
||||
0x05 0x018 1 39 --- Average Long Term Temperature
|
||||
0x05 0x020 1 62 --- Highest Temperature
|
||||
0x05 0x028 1 21 --- Lowest Temperature
|
||||
0x05 0x030 1 60 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 29 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 47 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 31 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 9533 --- Time in Over-Temperature
|
||||
0x05 0x058 1 55 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 13 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 167 --- Number of Hardware Resets
|
||||
0x06 0x010 4 1 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
223
HDD/Seagate/ST5000/ST5000LM000-2AN170/2703EBCF0EC8
Normal file
223
HDD/Seagate/ST5000/ST5000LM000-2AN170/2703EBCF0EC8
Normal file
@@ -0,0 +1,223 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 2.5 5400
|
||||
Device Model: ST5000LM000-2AN170
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001
|
||||
User Capacity: 5,000,981,078,016 bytes [5.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5526 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Jun 9 20:47:39 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 808) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x30a5) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 084 064 006 - 243646585
|
||||
3 Spin_Up_Time PO---- 100 096 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 166
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 085 060 045 - 337978526
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 11363 (49 146 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 163
|
||||
183 SATA_Downshift_Count -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 063 039 040 Past 37 (Min/Max 32/54 #2)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 122
|
||||
193 Load_Cycle_Count -O--CK 086 086 000 - 28951
|
||||
194 Temperature_Celsius -O---K 037 061 000 - 37 (0 17 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 084 064 000 - 243646585
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 2787 (97 39 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 33812889914
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 118411017584
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xd1 GPL VS 168 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/54 Celsius
|
||||
Lifetime Min/Max Temperature: 17/61 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (96)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 163 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 11363 --- Power-on Hours
|
||||
0x01 0x018 6 33759848122 --- Logical Sectors Written
|
||||
0x01 0x020 6 162394110 --- Number of Write Commands
|
||||
0x01 0x028 6 118443096696 --- Logical Sectors Read
|
||||
0x01 0x030 6 673494189 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 1883523863 N-- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 1883512523 N-- Head Flying Hours
|
||||
0x03 0x018 4 28951 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 123 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x010 1 39 --- Average Short Term Temperature
|
||||
0x05 0x018 1 38 --- Average Long Term Temperature
|
||||
0x05 0x020 1 61 --- Highest Temperature
|
||||
0x05 0x028 1 21 --- Lowest Temperature
|
||||
0x05 0x030 1 59 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 29 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 47 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 32 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 6336 --- Time in Over-Temperature
|
||||
0x05 0x058 1 55 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 13 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 174 --- Number of Hardware Resets
|
||||
0x06 0x010 4 18 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
226
HDD/Seagate/ST8000/ST8000DM004-2CX188/1178E8D89BFD
Normal file
226
HDD/Seagate/ST8000/ST8000DM004-2CX188/1178E8D89BFD
Normal file
@@ -0,0 +1,226 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p6 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda Compute
|
||||
Device Model: ST8000DM004-2CX188
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001
|
||||
User Capacity: 8,001,563,222,016 bytes [8.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5425 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Jun 15 18:47:44 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 966) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x30a5) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 077 064 006 - 45395267
|
||||
3 Spin_Up_Time PO---- 092 092 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 61
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 081 060 045 - 140028998
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 1975 (9 49 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 61
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 048 046 040 - 52 (Min/Max 27/53)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 37
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 251
|
||||
194 Temperature_Celsius -O---K 052 054 000 - 52 (0 22 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 077 064 000 - 45395267
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 1872 (32 10 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 11170721226
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 3563326724
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbd GPL VS 8 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xd1 GPL VS 264 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 52 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/53 Celsius
|
||||
Lifetime Min/Max Temperature: 22/54 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (20)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 61 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1975 --- Power-on Hours
|
||||
0x01 0x018 6 11170721467 --- Logical Sectors Written
|
||||
0x01 0x020 6 71821997 --- Number of Write Commands
|
||||
0x01 0x028 6 3562919642 --- Logical Sectors Read
|
||||
0x01 0x030 6 24855260 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 1973 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 1933 --- Head Flying Hours
|
||||
0x03 0x018 4 251 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 37 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 52 --- Current Temperature
|
||||
0x05 0x010 1 50 --- Average Short Term Temperature
|
||||
0x05 0x018 1 47 --- Average Long Term Temperature
|
||||
0x05 0x020 1 54 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 52 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 42 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 47 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 43 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 1032 --- Number of Hardware Resets
|
||||
0x06 0x010 4 547 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
Reference in New Issue
Block a user