mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 321, modified: 0)
This commit is contained in:
200
All_HDD.md
Normal file
200
All_HDD.md
Normal file
@@ -0,0 +1,200 @@
|
||||
Appendix 1: All HDD Samples
|
||||
===========================
|
||||
|
||||
This is a list of all tested HDD samples and their MTBFs. See more info on
|
||||
reliability test in the README. See SSD samples MTBFs in the Appendix 2 (All_SSD.md).
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Model | Size | Drive ID | Days | Err | MTBF |
|
||||
|-----------|--------------------|--------|--------------|-------|-------|--------|
|
||||
| WDC | WD1600JD-00GBB0 | 160 GB | 174B64FA6D11 | 5313 | 0 | 14.56 |
|
||||
| WDC | WD1600JD-00GBB0 | 160 GB | B987CF631DE2 | 5309 | 0 | 14.55 |
|
||||
| WDC | WD1600JD-00GBB0 | 160 GB | AEF7D2BC2CBA | 5308 | 0 | 14.55 |
|
||||
| Seagate | ST3120023A | 120 GB | CFFF016768F1 | 5214 | 0 | 14.29 |
|
||||
| WDC | WD1001FALS-00J7B0 | 1 TB | F228272CA526 | 4223 | 0 | 11.57 |
|
||||
| WDC | WD1001FALS-00J7B0 | 1 TB | BC775302F3D0 | 4223 | 0 | 11.57 |
|
||||
| WDC | WD1001FALS-00J7B0 | 1 TB | 0E2B0E84EBAB | 4223 | 0 | 11.57 |
|
||||
| Samsung | HD501LJ | 500 GB | 1BD671150948 | 4014 | 0 | 11.00 |
|
||||
| Seagate | ST3500630NS | 500 GB | 18474964BA39 | 4005 | 0 | 10.97 |
|
||||
| Hitachi | HDS725050KLA360 | 500 GB | A9CFD2B26630 | 3763 | 0 | 10.31 |
|
||||
| WDC | WD15EADS-00P8B0 | 1.5 TB | A26390F2CAED | 3554 | 0 | 9.74 |
|
||||
| WDC | WD2003FYYS-02W0B0 | 2 TB | 55B636AE7CE9 | 3072 | 0 | 8.42 |
|
||||
| WDC | WD2003FYYS-02W0B0 | 2 TB | 3E1628507DA9 | 3072 | 0 | 8.42 |
|
||||
| WDC | WD2003FYYS-02W0B0 | 2 TB | 5A67B1FA0E5F | 3031 | 0 | 8.31 |
|
||||
| WDC | WD2003FYYS-02W0B0 | 2 TB | 1FCF8CC33222 | 2981 | 0 | 8.17 |
|
||||
| WDC | WD20EARS-00MVWB0 | 2 TB | F1FB19E5016E | 2969 | 0 | 8.14 |
|
||||
| WDC | WD20EARX-00PASB0 | 2 TB | 10EC15076D37 | 2922 | 0 | 8.01 |
|
||||
| Hitachi | HUA723020ALA641 | 2 TB | 5B7005B0FA95 | 2714 | 0 | 7.44 |
|
||||
| Hitachi | HDT725025VLA380 | 250 GB | 22A6C9E780BF | 2680 | 0 | 7.34 |
|
||||
| WDC | WD20EARX-00PASB0 | 2 TB | 542C4CAAA23E | 2527 | 0 | 6.92 |
|
||||
| WDC | WD5003AZEX-00K1GA0 | 500 GB | B0E76D619E3A | 2461 | 0 | 6.74 |
|
||||
| WDC | WD10EALX-009BA0 | 1 TB | DE06E502BC17 | 2398 | 0 | 6.57 |
|
||||
| WDC | WD1002FBYS-02A6B0 | 1 TB | 013F16558DE1 | 2374 | 0 | 6.51 |
|
||||
| Seagate | ST3160318AS | 160 GB | 5E781043CFB0 | 2290 | 0 | 6.27 |
|
||||
| Seagate | ST4000NM0033-9Z... | 4 TB | 3E107E0D99C9 | 2281 | 0 | 6.25 |
|
||||
| Seagate | ST4000NM0033-9Z... | 4 TB | 04EBE94D138B | 2281 | 0 | 6.25 |
|
||||
| WDC | WD10EARX-00N0YB0 | 1 TB | 2E5BA7D80CDE | 2233 | 0 | 6.12 |
|
||||
| Hitachi | HUA723020ALA641 | 2 TB | 79BE99B5B32C | 2224 | 0 | 6.09 |
|
||||
| Hitachi | HDS721616PLAT80 | 160 GB | 120676B117DD | 2187 | 0 | 5.99 |
|
||||
| WDC | WD10EZRX-00L4HB0 | 1 TB | 4B40F3B3537A | 2073 | 0 | 5.68 |
|
||||
| WDC | WD10EZRX-00L4HB0 | 1 TB | D79D55090F4E | 2070 | 0 | 5.67 |
|
||||
| WDC | WD20EZRX-00D8PB0 | 2 TB | 85DC1F74D587 | 2026 | 0 | 5.55 |
|
||||
| WDC | WD30EZRX-00SPEB0 | 3 TB | 991B1AE2B8B4 | 2024 | 0 | 5.55 |
|
||||
| Toshiba | DT01ACA200 | 2 TB | 6ABB040F667C | 1992 | 0 | 5.46 |
|
||||
| Toshiba | DT01ACA200 | 2 TB | 3AA1524DEFBE | 1992 | 0 | 5.46 |
|
||||
| WDC | WD20EZRX-00D8PB0 | 2 TB | DF08C245D82A | 1992 | 0 | 5.46 |
|
||||
| Toshiba | DT01ACA200 | 2 TB | 60FF9E9DD9F2 | 1991 | 0 | 5.46 |
|
||||
| Toshiba | DT01ACA100 | 1 TB | EE4AA8A0E670 | 1942 | 0 | 5.32 |
|
||||
| WDC | WD10EZEX-08M2NA0 | 1 TB | F5F7D4F18146 | 1941 | 0 | 5.32 |
|
||||
| WDC | WD10EZEX-08M2NA0 | 1 TB | 0360EE971194 | 1925 | 0 | 5.27 |
|
||||
| Seagate | ST3320620A | 320 GB | 4CCB5639939A | 1913 | 0 | 5.24 |
|
||||
| Seagate | ST3500413AS | 500 GB | 118C4D6098A8 | 1885 | 0 | 5.17 |
|
||||
| Seagate | ST3500413AS | 500 GB | FBC60C19490A | 1885 | 0 | 5.17 |
|
||||
| Samsung | HD501LJ | 500 GB | EF58C0E9ABE3 | 3759 | 1 | 5.15 |
|
||||
| WDC | WD30EZRX-00DC0B0 | 3 TB | 9D5A4F2FD67C | 1870 | 0 | 5.12 |
|
||||
| Seagate | ST1000NC001-1DY162 | 1 TB | 56F4A6E70590 | 1848 | 0 | 5.06 |
|
||||
| WDC | WD30EFRX-68EUZN0 | 3 TB | 7E305DDD1497 | 1836 | 0 | 5.03 |
|
||||
| Hitachi | HUA722020ALA330 | 2 TB | 6293AEC6C3FA | 1757 | 0 | 4.82 |
|
||||
| Hitachi | HUA722020ALA330 | 2 TB | 8B348A8C0617 | 1750 | 0 | 4.80 |
|
||||
| Seagate | ST3320620AS | 320 GB | D89C07C13F33 | 1737 | 0 | 4.76 |
|
||||
| WDC | WD30EFRX-68EUZN0 | 3 TB | 95BBCB08BFF0 | 1737 | 0 | 4.76 |
|
||||
| WDC | WD5000AAKX-08U6AA0 | 500 GB | E0FD15B86C72 | 1673 | 0 | 4.58 |
|
||||
| WDC | WD30EZRX-00D8PB0 | 3 TB | 689D3FFC4F82 | 1670 | 0 | 4.58 |
|
||||
| WDC | WD30EZRX-00D8PB0 | 3 TB | A6ABFE44C61D | 1670 | 0 | 4.58 |
|
||||
| Seagate | ST3250318AS | 250 GB | 39EAC67B78F6 | 1636 | 0 | 4.48 |
|
||||
| WDC | WD20EZRX-00DC0B0 | 2 TB | 928B94FC109E | 1633 | 0 | 4.48 |
|
||||
| Seagate | ST91000640NS | 1 TB | 66832ACE4BF6 | 1630 | 0 | 4.47 |
|
||||
| Seagate | ST4000DM000-1F2168 | 4 TB | 42216A2FC4ED | 1593 | 0 | 4.37 |
|
||||
| WDC | WD10EZRZ-00HTKB0 | 1 TB | D99A6B5A01F8 | 1591 | 0 | 4.36 |
|
||||
| Seagate | ST2000DM001-1CH164 | 2 TB | D559A8F41E88 | 1518 | 0 | 4.16 |
|
||||
| WDC | WD40EFRX-68WT0N0 | 4 TB | 760EF829678F | 1468 | 0 | 4.02 |
|
||||
| Seagate | ST4000NM0033-9Z... | 4 TB | AF5573129323 | 1402 | 0 | 3.84 |
|
||||
| Seagate | ST5000DM000-1FK178 | 5 TB | 2F3183103AD9 | 1387 | 0 | 3.80 |
|
||||
| WDC | WD40EFRX-68WT0N0 | 4 TB | 044C7A0F0FE4 | 1347 | 0 | 3.69 |
|
||||
| WDC | WD20EFRX-68AX9N0 | 2 TB | 938188F4E867 | 2421 | 1 | 3.32 |
|
||||
| Seagate | ST9250315AS | 250 GB | C8D7EF8B922C | 1192 | 0 | 3.27 |
|
||||
| WDC | WD80EFZX-68UW8N0 | 8 TB | 8E03BF079ECE | 1184 | 0 | 3.24 |
|
||||
| Seagate | ST4000LM016-1N2170 | 4 TB | B9475BCCA4D8 | 1146 | 0 | 3.14 |
|
||||
| WDC | WD20EZRZ-00Z5HB0 | 2 TB | D0A038188FA0 | 1137 | 0 | 3.12 |
|
||||
| WDC | WD20EZRZ-00Z5HB0 | 2 TB | 7E402E3FF29A | 1093 | 0 | 3.00 |
|
||||
| Seagate | ST320VT000-1BS14C | 320 GB | A20C22C4AF6F | 1083 | 0 | 2.97 |
|
||||
| Toshiba | DT01ACA100 | 1 TB | 69726981F75F | 1065 | 0 | 2.92 |
|
||||
| Toshiba | DT01ACA100 | 1 TB | 7D00B503FDFE | 1065 | 0 | 2.92 |
|
||||
| WDC | WD20EARS-00MVWB0 | 2 TB | 7E8F8C1B7B1F | 1061 | 0 | 2.91 |
|
||||
| WDC | WD20EARX-00PASB0 | 2 TB | 9A07E12AFCBF | 1058 | 0 | 2.90 |
|
||||
| Seagate | ST3160023A | 160 GB | 57047AF8E587 | 1056 | 0 | 2.89 |
|
||||
| Seagate | ST3250312AS | 250 GB | 5C0F642B66FF | 1039 | 0 | 2.85 |
|
||||
| WDC | WD20EZRZ-00Z5HB0 | 2 TB | 3C56C7F32506 | 1016 | 0 | 2.78 |
|
||||
| WDC | WD40EFRX-68N32N0 | 4 TB | C857CFF718BC | 1013 | 0 | 2.78 |
|
||||
| Samsung | HD501LJ | 500 GB | DA9C7BFC6782 | 4013 | 3 | 2.75 |
|
||||
| WDC | WD80EFZX-68UW8N0 | 8 TB | F5688C2102F7 | 956 | 0 | 2.62 |
|
||||
| WDC | WD80EFZX-68UW8N0 | 8 TB | 22DB9DCBDED9 | 954 | 0 | 2.62 |
|
||||
| WDC | WD10EZEX-60WN4A0 | 1 TB | 6526181A72C8 | 890 | 0 | 2.44 |
|
||||
| WDC | WD10EZEX-60WN4A0 | 1 TB | 3F02613DC57B | 890 | 0 | 2.44 |
|
||||
| WDC | WD10EZEX-00BN5A0 | 1 TB | 0BABC6D73CF2 | 864 | 0 | 2.37 |
|
||||
| WDC | WD20NMVW-11AV3S2 | 2 TB | 19CB6266A5F4 | 860 | 0 | 2.36 |
|
||||
| WDC | WD20NMVW-11EDZS7 | 2 TB | 67EE2240CD22 | 856 | 0 | 2.35 |
|
||||
| WDC | WD20EZRZ-00Z5HB0 | 2 TB | 5E448F5C5385 | 827 | 0 | 2.27 |
|
||||
| WDC | WD4002FFWX-68TZ4N0 | 4 TB | 079FA436DA32 | 802 | 0 | 2.20 |
|
||||
| WDC | WD4002FFWX-68TZ4N0 | 4 TB | 736625A3997C | 802 | 0 | 2.20 |
|
||||
| WDC | WD10EZEX-21WN4A0 | 1 TB | 4A04536E9744 | 799 | 0 | 2.19 |
|
||||
| WDC | WD10EZEX-07WN4A0 | 1 TB | 0A48A5A0F35D | 790 | 0 | 2.17 |
|
||||
| WDC | WD40EFRX-68N32N0 | 4 TB | BC01E00D59B2 | 772 | 0 | 2.12 |
|
||||
| Seagate | ST6000DM003-2CY186 | 6 TB | E62AC93B0E19 | 765 | 0 | 2.10 |
|
||||
| Seagate | ST2000LM015-2E8174 | 2 TB | B9CCD1AAE7DB | 745 | 0 | 2.04 |
|
||||
| Toshiba | HDWQ140 | 4 TB | 9053FCE58A07 | 743 | 0 | 2.04 |
|
||||
| Toshiba | HDWQ140 | 4 TB | 37BBA354B965 | 741 | 0 | 2.03 |
|
||||
| Fujitsu | MJA2160BH FFS G1 | 160 GB | 6C038A2DAFFF | 707 | 0 | 1.94 |
|
||||
| Seagate | ST8000VN0022-2E... | 8 TB | 59D3FB96B73C | 658 | 0 | 1.80 |
|
||||
| Seagate | ST2000DM001-1CH164 | 2 TB | 62A4A80CFE9C | 630 | 0 | 1.73 |
|
||||
| Seagate | ST8000VN0002-1Z... | 8 TB | CDF29EC5DCF0 | 625 | 0 | 1.71 |
|
||||
| Samsung | HD501LJ | 500 GB | D37BC44F1A91 | 3698 | 5 | 1.69 |
|
||||
| WDC | WD2500BEVT-22A23T0 | 250 GB | CFA65DCCFF38 | 611 | 0 | 1.68 |
|
||||
| Seagate | ST4000DM000-1F2168 | 4 TB | 8071CC86F9BC | 604 | 0 | 1.66 |
|
||||
| WDC | WD40EZRZ-22GXCB0 | 4 TB | EDB32D87AAA0 | 598 | 0 | 1.64 |
|
||||
| Seagate | ST1000VX000-1CU162 | 1 TB | FA598C1BF090 | 596 | 0 | 1.63 |
|
||||
| Hitachi | HUA723030ALA640 | 3 TB | B570BB030A4D | 563 | 0 | 1.54 |
|
||||
| Hitachi | HTS725050A7E630 | 500 GB | 3F2B86E01F8A | 535 | 0 | 1.47 |
|
||||
| Hitachi | HTS541660J9SA00 | 64 GB | 290A83280B81 | 517 | 0 | 1.42 |
|
||||
| WDC | WD100EMAZ-00WJTA0 | 10 TB | EFFA89F4BF33 | 517 | 0 | 1.42 |
|
||||
| WDC | WD15EADS-00P8B0 | 1.5 TB | DA8FFAAFCAC4 | 2578 | 4 | 1.41 |
|
||||
| WDC | WD40EFRX-68N32N0 | 4 TB | 6DDDF5052987 | 467 | 0 | 1.28 |
|
||||
| Toshiba | MQ01ABD100 | 1 TB | C7A93B3F187E | 463 | 0 | 1.27 |
|
||||
| WDC | WD7500AYYS-01RCA0 | 752 GB | 66B364C2B2E8 | 455 | 0 | 1.25 |
|
||||
| HGST | HTS541075A7E630 | 752 GB | A30184300B45 | 454 | 0 | 1.25 |
|
||||
| WDC | WD5000BPVT-24HXZT3 | 500 GB | 0BC83243733C | 429 | 0 | 1.18 |
|
||||
| WDC | WD5000AAKS-00A7B0 | 500 GB | 56DE6283F211 | 424 | 0 | 1.16 |
|
||||
| HGST | HTS721010A9E630 | 1 TB | DCF1A8E71D52 | 423 | 0 | 1.16 |
|
||||
| WDC | WD40EZRZ-75GXCB0 | 4 TB | 84DFE8A3615B | 422 | 0 | 1.16 |
|
||||
| Seagate | ST380811AS | 80 GB | 3EDE73A1A00D | 383 | 0 | 1.05 |
|
||||
| WDC | WD15EADS-00P8B0 | 1.5 TB | 907F65E04B29 | 3325 | 8 | 1.01 |
|
||||
| WDC | WD2002FYPS-01U1B0 | 2 TB | B0438A2B2BFD | 1048 | 2 | 0.96 |
|
||||
| Seagate | ST1000LM024 HN-... | 1 TB | CCA7C0EF0228 | 347 | 0 | 0.95 |
|
||||
| WDC | WD1600JD-00GBB0 | 160 GB | E545026BA23A | 5323 | 15 | 0.91 |
|
||||
| WDC | WD40EFRX-68N32N0 | 4 TB | C7AB7644C7AC | 319 | 0 | 0.87 |
|
||||
| WDC | WD5000LPLX-00ZNTT0 | 500 GB | AC0457C6B12D | 263 | 0 | 0.72 |
|
||||
| WDC | WD5003AZEX-00MK2A0 | 500 GB | 700FE30F57C0 | 2015 | 7 | 0.69 |
|
||||
| Seagate | ST4000VN008-2DR166 | 4 TB | 53E85D414D7D | 239 | 0 | 0.66 |
|
||||
| Seagate | ST500LM012 HN-M... | 500 GB | 56D35D5B08B4 | 213 | 0 | 0.59 |
|
||||
| WDC | WD2002FYPS-01U1B0 | 2 TB | 5F31B0A40759 | 2094 | 9 | 0.57 |
|
||||
| WDC | WD5003AZEX-00K3CA0 | 500 GB | 2C6136E2B834 | 176 | 0 | 0.48 |
|
||||
| HGST | HTS725050A7E630 | 500 GB | AFF6E8E2A505 | 175 | 0 | 0.48 |
|
||||
| WDC | WD2003FZEX-00SRLA0 | 2 TB | FB891EBB6F81 | 327 | 1 | 0.45 |
|
||||
| WDC | WD40EFRX-68N32N0 | 4 TB | C4241540B18A | 319 | 1 | 0.44 |
|
||||
| WDC | WD60EFAX-68SHWN0 | 6 TB | 7F33B1E47105 | 154 | 0 | 0.42 |
|
||||
| WDC | WD60EFAX-68SHWN0 | 6 TB | 058E85E489BF | 153 | 0 | 0.42 |
|
||||
| WDC | WD80EFZX-68UW8N0 | 8 TB | 61D3D70A46C3 | 1184 | 8 | 0.36 |
|
||||
| Seagate | ST2000LM015-2E8174 | 2 TB | AA3FB7EC6773 | 116 | 0 | 0.32 |
|
||||
| Seagate | ST2000LM007-1R8174 | 2 TB | 7F0DCB998EE6 | 111 | 0 | 0.31 |
|
||||
| WDC | WD40EFRX-68N32N0 | 4 TB | 1D691B2028A0 | 319 | 2 | 0.29 |
|
||||
| Hitachi | HTS421260H9AT00 | 64 GB | B3561755EAE1 | 1338 | 12 | 0.28 |
|
||||
| Seagate | ST500LM021-1KJ152 | 500 GB | 6C78199707FD | 101 | 0 | 0.28 |
|
||||
| WDC | WD60EFAX-68SHWN0 | 6 TB | 4FE6E61C6AFB | 96 | 0 | 0.26 |
|
||||
| Toshiba | HDWD120 | 2 TB | 5776A120C467 | 77 | 0 | 0.21 |
|
||||
| Toshiba | HDWD110 | 1 TB | A99A2856788B | 62 | 0 | 0.17 |
|
||||
| Seagate | ST500LM030-2E717D | 500 GB | B6A38423E772 | 55 | 0 | 0.15 |
|
||||
| Hitachi | HUA721010KLA330 | 1 TB | 93B47133802E | 52 | 0 | 0.14 |
|
||||
| Seagate | ST1000LM048-2E7172 | 1 TB | D377199C1EDD | 44 | 0 | 0.12 |
|
||||
| WDC | WD5003AZEX-00K3CA0 | 500 GB | A4581DEEF1BB | 377 | 8 | 0.11 |
|
||||
| WDC | WD5000LPLX-08ZNTT0 | 500 GB | 9DDAFF939B76 | 41 | 0 | 0.11 |
|
||||
| Toshiba | MQ04ABF100 | 1 TB | 5A6F39BCA6B5 | 32 | 0 | 0.09 |
|
||||
| Toshiba | MQ04ABF100 | 1 TB | B4920ED6AFBF | 152 | 4 | 0.08 |
|
||||
| Samsung | HM320JI | 320 GB | 6A9B4A56F398 | 258 | 9 | 0.07 |
|
||||
| WDC | WD10SDZW-11UMGS0 | 1 TB | 82231660F583 | 24 | 0 | 0.07 |
|
||||
| Toshiba | MK5061GSYN | 500 GB | 78BEB04367F6 | 15 | 0 | 0.04 |
|
||||
| Hitachi | HTS543212L9A300 | 120 GB | 9458ABA347BE | 1158 | 88 | 0.04 |
|
||||
| Seagate | ST2000DM001-1CH164 | 2 TB | 183CF84B7E96 | 1283 | 153 | 0.02 |
|
||||
| Hitachi | HDS721010CLA332 | 1 TB | 64970F0E967D | 1511 | 220 | 0.02 |
|
||||
| Hitachi | HUA722020ALA330 | 2 TB | D089BA327DB5 | 1753 | 362 | 0.01 |
|
||||
| HGST | HTS721010A9E630 | 1 TB | 0E802F163734 | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 0A188F1CD3BA | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 144085CA4BA4 | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 3ED8AEB0B74D | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 442769CE2E0F | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 451BE7BB8810 | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 563B961B0EB5 | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 650F39F95C89 | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 661707D1EB57 | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 7C8BF5C82E69 | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 811E3EF98400 | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 8AC9E335B746 | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | C8E0C70F49ED | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 21AADC862859 | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 3BE93499BD79 | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 654AE1257A4E | 3 | 0 | 0.01 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 78504B519B2A | 3 | 0 | 0.01 |
|
||||
| WDC | WD40EFRX-68N32N0 | 4 TB | 0FE5461ABC90 | 2 | 0 | 0.01 |
|
||||
| Seagate | ST3500514NS | 500 GB | 17190995F3F2 | 205 | 103 | 0.01 |
|
||||
| Seagate | ST2000DM008-2FR102 | 2 TB | ED7A60B17EA5 | 161 | 144 | 0.00 |
|
||||
| WDC | WD6002FRYZ-01WD5B1 | 6 TB | 0CD9B193DFCB | 165 | 372 | 0.00 |
|
||||
| Seagate | ST9500420AS | 500 GB | 5C72704B9149 | 315 | 738 | 0.00 |
|
||||
| Seagate | ST500LM021-1KJ152 | 500 GB | 8834A4EAFC7A | 353 | 1009 | 0.00 |
|
||||
| HGST | HTS541075A7E630 | 752 GB | AD3BF90AF280 | 187 | 1014 | 0.00 |
|
||||
| Hitachi | HTS721060G9AT00 | 64 GB | 73147CBA22BD | 0 | 37 | 0.00 |
|
||||
21
All_NVMe.md
Normal file
21
All_NVMe.md
Normal file
@@ -0,0 +1,21 @@
|
||||
Appendix 5: All NVMe Samples
|
||||
============================
|
||||
|
||||
This is a list of all tested NVMe samples and their MTBFs. See more info on
|
||||
reliability test in the README. See HDD samples MTBFs in the Appendix 1 (All_HDD.md)
|
||||
and SSD samples MTBFs in the Appendix 2 (All_SSD.md).
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Model | Size | Drive ID | Days | Err | MTBF |
|
||||
|-----------|--------------------|--------|--------------|-------|-------|--------|
|
||||
| Samsung | MZVPV256HDGL-000L7 | 256 GB | 344D509D4D1D | 915 | 0 | 2.51 |
|
||||
| Intel | SSDPEKNW010T8 | 1 TB | 8AD553263F58 | 405 | 0 | 1.11 |
|
||||
| Corsair | Force MP510 1.9TB | 1.9 TB | EAB4CDC80694 | 109 | 0 | 0.30 |
|
||||
| Samsung | SSD 960 EVO | 1 TB | 241D5CAD434E | 154 | 3 | 0.11 |
|
||||
145
All_SSD.md
Normal file
145
All_SSD.md
Normal file
@@ -0,0 +1,145 @@
|
||||
Appendix 2: All SSD Samples
|
||||
===========================
|
||||
|
||||
This is a list of all tested SSD samples and their MTBFs. See more info on
|
||||
reliability test in the README. See HDD samples MTBFs in the Appendix 1 (All_HDD.md).
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Model | Size | Drive ID | Days | Err | MTBF |
|
||||
|-----------|--------------------|--------|--------------|-------|-------|--------|
|
||||
| Intel | SSDSA2CT040G3 | 40 GB | FFB33E283F18 | 2994 | 0 | 8.20 |
|
||||
| Samsung | SSD 840 Series | 120 GB | 9E96649CFED6 | 2655 | 0 | 7.28 |
|
||||
| OCZ | AGILITY3 | 120 GB | 531A2B671C06 | 2119 | 0 | 5.81 |
|
||||
| Samsung | SSD 850 EVO | 250 GB | 708BDFA58843 | 1648 | 0 | 4.52 |
|
||||
| Samsung | SSD 850 EVO | 250 GB | 8C49516A825E | 1648 | 0 | 4.52 |
|
||||
| Intel | SSDSC2BW240A3L | 240 GB | 1AFEFC2A89FA | 1425 | 0 | 3.91 |
|
||||
| Samsung | SSD 850 EVO | 500 GB | 0D6AF08B8404 | 1364 | 0 | 3.74 |
|
||||
| Samsung | SSD 850 EVO | 250 GB | 741AB0880F27 | 1312 | 0 | 3.59 |
|
||||
| Crucial | FCCT128M4SSD1 | 128 GB | 1AD1B7221CE5 | 1267 | 0 | 3.47 |
|
||||
| Intel | SSDSC2BW240H6 | 240 GB | 62B67E8E36C4 | 1258 | 0 | 3.45 |
|
||||
| SanDisk | Ultra II | 960 GB | 12459DB064E4 | 1202 | 0 | 3.29 |
|
||||
| SanDisk | Ultra II | 960 GB | 0F240FC307CD | 1202 | 0 | 3.29 |
|
||||
| SuperM... | SSD | 16 GB | CE8863A4D332 | 1176 | 0 | 3.22 |
|
||||
| Samsung | SSD 850 EVO mSATA | 1 TB | 43FDDDD82CC6 | 2157 | 1 | 2.96 |
|
||||
| Samsung | SSD 850 EVO | 1 TB | 8BD341C95452 | 1068 | 0 | 2.93 |
|
||||
| Kingston | SKC400S37512G | 512 GB | 2D724BD9FF8D | 1059 | 0 | 2.90 |
|
||||
| Kingston | SKC400S37512G | 512 GB | 6D7F99EA4EAF | 1059 | 0 | 2.90 |
|
||||
| Toshiba | THNSNJ128GCSU | 128 GB | 91E68A945423 | 1009 | 0 | 2.77 |
|
||||
| Samsung | SSD 850 EVO | 250 GB | 726CD857B59F | 925 | 0 | 2.53 |
|
||||
| Samsung | SSD 850 EVO | 250 GB | AD49B3EA3046 | 925 | 0 | 2.53 |
|
||||
| Samsung | SSD 850 EVO | 250 GB | DF67D90D2A7A | 925 | 0 | 2.53 |
|
||||
| Samsung | SSD 850 EVO | 250 GB | DF736B6598E9 | 925 | 0 | 2.53 |
|
||||
| Crucial | CT240M500SSD3 | 240 GB | 2883DE3FC7A5 | 917 | 0 | 2.51 |
|
||||
| Crucial | CT250MX200SSD1 | 250 GB | 9B6FE8DB248D | 905 | 0 | 2.48 |
|
||||
| Kingston | SUV400S37240G | 240 GB | 2DC237E36B76 | 833 | 0 | 2.28 |
|
||||
| Crucial | FCCT128M4SSD1 | 128 GB | 17B168CC2ECE | 817 | 0 | 2.24 |
|
||||
| Crucial | CT1050MX300SSD1 | 1 TB | 648ECCD7B1AA | 811 | 0 | 2.22 |
|
||||
| Samsung | SSD 860 EVO | 500 GB | 5FA7624AC57B | 802 | 0 | 2.20 |
|
||||
| Micron | 5100_MTFDDAK240TCB | 240 GB | 35184446C3DB | 779 | 0 | 2.14 |
|
||||
| Micron | 5100_MTFDDAK240TCB | 240 GB | E194B45FC791 | 779 | 0 | 2.14 |
|
||||
| Micron | 5100_MTFDDAK240TCB | 240 GB | 4BE166349018 | 778 | 0 | 2.13 |
|
||||
| Micron | 5100_MTFDDAK240TCB | 240 GB | 8ECD1F51A5B7 | 778 | 0 | 2.13 |
|
||||
| Apple | SSD TS256C | 256 GB | 751D09466F92 | 752 | 0 | 2.06 |
|
||||
| Samsung | SSD 750 EVO | 250 GB | 72BC89D9FD2F | 734 | 0 | 2.01 |
|
||||
| Kingston | SV300S37A120G | 120 GB | 7E41E37286E7 | 709 | 0 | 1.94 |
|
||||
| Samsung | SSD 850 EVO | 250 GB | 5B7443313255 | 702 | 0 | 1.92 |
|
||||
| Samsung | SSD 850 EVO M.2 | 500 GB | 3C3646DE714D | 697 | 0 | 1.91 |
|
||||
| Samsung | MZ7PC128HAFU-000L1 | 128 GB | 0F321C63715D | 683 | 0 | 1.87 |
|
||||
| SanDisk | Ultra II | 480 GB | 6E56DA9E59CE | 676 | 0 | 1.85 |
|
||||
| Samsung | SSD 860 EVO M.2 | 2 TB | B93CF78FD433 | 607 | 0 | 1.66 |
|
||||
| Crucial | M4-CT064M4SSD2 | 64 GB | AF1883973174 | 589 | 0 | 1.61 |
|
||||
| Hoodisk | SSD | 32 GB | EE65DE21DD90 | 587 | 0 | 1.61 |
|
||||
| Kingston | SUV500MS240G | 240 GB | 3D414073FCD9 | 580 | 0 | 1.59 |
|
||||
| Samsung | MZ7TE256HMHP-000H1 | 256 GB | EAA19A4D16F8 | 544 | 0 | 1.49 |
|
||||
| Samsung | SSD 850 EVO | 1 TB | BEB64C2912ED | 2157 | 3 | 1.48 |
|
||||
| Samsung | SSD 850 EVO | 500 GB | D8B7C9E330D7 | 525 | 0 | 1.44 |
|
||||
| Samsung | SSD 850 EVO mSATA | 250 GB | 92EC8E6BBD4B | 516 | 0 | 1.42 |
|
||||
| Samsung | MZ7TY256HDHP-000L7 | 256 GB | AE95838BEEBD | 516 | 0 | 1.41 |
|
||||
| Samsung | SSD 860 EVO | 1 TB | 3805D45E8E42 | 515 | 0 | 1.41 |
|
||||
| Plextor | PX-128M7VC | 128 GB | 38EE83F81282 | 483 | 0 | 1.32 |
|
||||
| SPCC | SSD | 64 GB | BE2BE3E86A9B | 482 | 0 | 1.32 |
|
||||
| Samsung | SSD 850 PRO | 256 GB | 6DDA7383BEAE | 467 | 0 | 1.28 |
|
||||
| AEGO | SSD | 120 GB | DD401F7D44A3 | 445 | 0 | 1.22 |
|
||||
| Samsung | SSD PM830 FDE 2... | 256 GB | 41772AC62177 | 440 | 0 | 1.21 |
|
||||
| SanDisk | SD8SN8U128G1002 | 128 GB | 027B5A09BF54 | 424 | 0 | 1.16 |
|
||||
| Samsung | SSD 850 EVO | 1 TB | 5277D70B7CAA | 362 | 0 | 0.99 |
|
||||
| Samsung | SSD 850 EVO | 120 GB | EEF3B0DD1A68 | 358 | 0 | 0.98 |
|
||||
| Intel | SSDSC2BB480G7 | 480 GB | CF4E675990BE | 703 | 1 | 0.96 |
|
||||
| Intel | SSDSA2M080G2GC | 80 GB | 27C6CB1E583A | 3057 | 8 | 0.93 |
|
||||
| Intel | SSDSC2CW060A3 | 64 GB | 300ED56583C9 | 274 | 0 | 0.75 |
|
||||
| Samsung | SSD 860 EVO | 500 GB | DD1891C7B2F2 | 246 | 0 | 0.68 |
|
||||
| SanDisk | SD5SG2256G1052E | 256 GB | CCB49E73BA1A | 246 | 0 | 0.68 |
|
||||
| Samsung | SSD 840 PRO Series | 256 GB | EC680A1F4032 | 243 | 0 | 0.67 |
|
||||
| SPCC | SSD | 120 GB | F5A5BA4843D2 | 228 | 0 | 0.63 |
|
||||
| Samsung | SSD 840 Series | 250 GB | 1EFAF30D92C0 | 227 | 0 | 0.62 |
|
||||
| WDC | WDS500G1B0A-00H9H0 | 500 GB | D48760C20919 | 196 | 0 | 0.54 |
|
||||
| Samsung | SSD 860 EVO mSATA | 500 GB | A5EBC25744B2 | 188 | 0 | 0.52 |
|
||||
| Samsung | SSD 860 EVO | 500 GB | 916C6BDA8A20 | 183 | 0 | 0.50 |
|
||||
| Samsung | SSD 860 EVO | 1 TB | B1B1CEF2626E | 181 | 0 | 0.50 |
|
||||
| Samsung | SSD 850 EVO M.2 | 250 GB | 7AB384160713 | 162 | 0 | 0.44 |
|
||||
| Samsung | SSD 860 QVO | 1 TB | 1FD0BB72CE90 | 150 | 0 | 0.41 |
|
||||
| Transcend | TS240GMTS420S | 240 GB | 0600F99C7A91 | 145 | 0 | 0.40 |
|
||||
| Samsung | SSD 860 QVO | 4 TB | A7F9811844BB | 141 | 0 | 0.39 |
|
||||
| KingSpec | NT-128 | 128 GB | 62AC25420CF5 | 140 | 0 | 0.38 |
|
||||
| Samsung | SSD 850 EVO | 500 GB | F14082D7E628 | 138 | 0 | 0.38 |
|
||||
| Kingston | SA400S37480G | 480 GB | 63D28D46694E | 135 | 0 | 0.37 |
|
||||
| Crucial | CT250MX200SSD1 | 250 GB | 1DBA3C9B0868 | 130 | 0 | 0.36 |
|
||||
| WDC | WDS480G2G0A-00JH30 | 480 GB | 851ED0A48527 | 129 | 0 | 0.35 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 6634C44D2667 | 123 | 0 | 0.34 |
|
||||
| Micron | 1100_MTFDDAK256TBN | 256 GB | 270BD7E81CFA | 115 | 0 | 0.32 |
|
||||
| Verbatim | Vi500 S3 480GB SSD | 480 GB | 630F2F08C53A | 115 | 0 | 0.32 |
|
||||
| Crucial | CT120BX300SSD1 | 120 GB | EBE522823790 | 108 | 0 | 0.30 |
|
||||
| Crucial | CT525MX300SSD1 | 528 GB | 15A17F9A0137 | 300 | 2 | 0.27 |
|
||||
| Intel | SSDSC2BW240A4 | 240 GB | 2E8ACB1DA6B9 | 89 | 0 | 0.24 |
|
||||
| Samsung | SSD 860 QVO | 2 TB | 0016CA43DC4F | 88 | 0 | 0.24 |
|
||||
| Kingston | SUV500MS480G | 480 GB | 91AF2AA641F2 | 86 | 0 | 0.24 |
|
||||
| Toshiba | TR200 | 240 GB | B9DEFBBEAC7F | 77 | 0 | 0.21 |
|
||||
| Samsung | SSD 860 EVO | 500 GB | 138CC007FB6F | 77 | 0 | 0.21 |
|
||||
| SPCC | SSD | 256 GB | A783A66CB712 | 71 | 0 | 0.19 |
|
||||
| Samsung | SSD 860 EVO | 4 TB | E9F981F90C3C | 68 | 0 | 0.19 |
|
||||
| Samsung | MZMTE1T0HMJH-00000 | 1 TB | 5CDE597FB3B5 | 59 | 0 | 0.16 |
|
||||
| Crucial | CT500MX200SSD1 | 500 GB | 85009BF49FBA | 54 | 0 | 0.15 |
|
||||
| Corsair | Force LS SSD | 64 GB | 8B5DABA92083 | 39 | 0 | 0.11 |
|
||||
| ADATA | SU750 | 256 GB | 1B0890D14696 | 36 | 0 | 0.10 |
|
||||
| Intel | SSDSC2BF180A4L | 180 GB | 0BA41799BE7E | 107 | 2 | 0.10 |
|
||||
| Kingston | SA400S37120G | 120 GB | E38BE391FC77 | 22 | 0 | 0.06 |
|
||||
| Micron | MTFDDAV256MBF-1... | 256 GB | 7374477AE7D4 | 21 | 0 | 0.06 |
|
||||
| Samsung | SSD 850 EVO | 250 GB | 9489C78A2D56 | 17 | 0 | 0.05 |
|
||||
| Crucial | CT120BX500SSD1 | 120 GB | 4E80C9ADAF10 | 14 | 0 | 0.04 |
|
||||
| Kingston | SUV500MS480G | 480 GB | DB1644A0BF24 | 12 | 0 | 0.03 |
|
||||
| Leven | JAJS600M512C | 512 GB | F0E981EFBCAB | 9 | 0 | 0.03 |
|
||||
| Transcend | TS128GMTS430S | 128 GB | EFE5BC0610B6 | 8 | 0 | 0.02 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 1984E43E44F1 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 19EFAD8CFF01 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 3532BB96FC46 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 3A0FCAE4488A | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 3DBDD94A7746 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 4298DF2EBA82 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 449AA7F96715 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 4FB843407880 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 612F294C7F78 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 696DC019A710 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 7E433B4CF0FC | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 8472603979D0 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | 9F948F3B7FDA | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | A04EC822CE25 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | A2FF35985D3C | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | A4909B503BFB | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | A4CDD04360F0 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | BD6C2D32DC02 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | C01B0EBE4243 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | C928CC0370B4 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | D1A1C6C0D3C9 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | E8298EA3E785 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | F1154F5B0B16 | 3 | 0 | 0.01 |
|
||||
| WDC | WDS100T2B0A-00SM50 | 1 TB | F69DD43A07E3 | 3 | 0 | 0.01 |
|
||||
| Intel | SSDSCKKF256G8H | 256 GB | 433753F7B246 | 144 | 89 | 0.00 |
|
||||
| Lite-On | LCH-128V2S | 128 GB | 730E94A464CF | 1 | 0 | 0.00 |
|
||||
| Intel | SSDSC2KW480H6 | 480 GB | 6832CA9672D0 | 39 | 1010 | 0.00 |
|
||||
170
HDD/Fujitsu/MJA2160/MJA2160BH FFS G1/6C038A2DAFFF
Normal file
170
HDD/Fujitsu/MJA2160/MJA2160BH FFS G1/6C038A2DAFFF
Normal file
@@ -0,0 +1,170 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Fujitsu MJA BH
|
||||
Device Model: FUJITSU MJA2160BH FFS G1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00000e ...
|
||||
Firmware Version: 00810020
|
||||
User Capacity: 160,041,885,696 bytes [160 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 3f
|
||||
SATA Version is: SATA 2.6, 1.5 Gb/s
|
||||
Local Time is: Tue May 26 13:28:20 2020 +06
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 508) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 72) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 046 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 030 - 0
|
||||
3 Spin_Up_Time PO---- 100 100 025 - 0
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 15397
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 024 - 0
|
||||
7 Seek_Error_Rate POSR-- 100 100 047 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 019 - 0
|
||||
9 Power_On_Hours -O--CK 067 067 000 - 16977
|
||||
10 Spin_Retry_Count PO--C- 100 100 020 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 15185
|
||||
160 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 092 092 000 - 12892637237
|
||||
193 Load_Cycle_Count -O--CK 090 090 000 - 217148
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 37 (Min/Max 16/54)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 253 000 - 0
|
||||
200 Multi_Zone_Error_Rate POSR-- 100 100 060 - 0
|
||||
203 Run_Out_Cancel -O---- 100 100 000 - 0
|
||||
240 Head_Flying_Hours -OSRCK 200 200 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 717
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 64 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 2 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 1 Device vendor specific log
|
||||
0xa2 GPL,SL VS 193 Device vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (2 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 10935 -
|
||||
# 2 Short offline Completed without error 00% 10935 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/38 Celsius
|
||||
Lifetime Min/Max Temperature: 16/54 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 478 (335)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0002 4 0 R_ERR response for data FIS
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
|
||||
20
HDD/Fujitsu/README.md
Normal file
20
HDD/Fujitsu/README.md
Normal file
@@ -0,0 +1,20 @@
|
||||
Fujitsu Hard Drives
|
||||
===================
|
||||
|
||||
This is a list of all tested Fujitsu hard drive models and their MTBFs. See more
|
||||
info on reliability test in the [README](https://github.com/bsdhw/SMART).
|
||||
|
||||
HDD by Model
|
||||
------------
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Model | Size | Samples | Days | Err | MTBF |
|
||||
|-----------|--------------------|--------|---------|-------|-------|--------|
|
||||
| Fujitsu | MJA2160BH FFS G1 | 160 GB | 1 | 707 | 0 | 1.94 |
|
||||
188
HDD/HGST/HTS5410/HTS541075A7E630/A30184300B45
Normal file
188
HDD/HGST/HTS5410/HTS541075A7E630/A30184300B45
Normal file
@@ -0,0 +1,188 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: HGST Travelstar Z5K1000
|
||||
Device Model: HGST HTS541075A7E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: SE2OA4A0
|
||||
User Capacity: 750,156,374,016 bytes [750 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun May 24 11:39:48 2020 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x51) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 169) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--K 100 100 040 - 0
|
||||
3 Spin_Up_Time PO---K 123 100 033 - 1
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 2525
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate POSR-K 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--K 100 100 040 - 0
|
||||
9 Power_On_Hours -O--CK 076 076 000 - 10919
|
||||
10 Spin_Retry_Count PO--CK 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 2412
|
||||
183 Runtime_Bad_Block -O--CK 100 100 001 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 098 000 - 196610
|
||||
190 Airflow_Temperature_Cel -O---K 070 045 045 Past 30 (Min/Max 24/30)
|
||||
191 G-Sense_Error_Rate -O--CK 094 094 000 - 1597
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 3014702
|
||||
193 Load_Cycle_Count -O--CK 079 079 000 - 211939
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 0
|
||||
223 Load_Retry_Count -O-R-K 100 083 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 10916 -
|
||||
# 2 Short offline Completed without error 00% 10915 -
|
||||
# 3 Short offline Completed without error 00% 10914 -
|
||||
# 4 Short offline Completed without error 00% 10907 -
|
||||
# 5 Short offline Completed without error 00% 10895 -
|
||||
# 6 Short offline Completed without error 00% 10892 -
|
||||
# 7 Short offline Completed without error 00% 10891 -
|
||||
# 8 Short offline Completed without error 00% 10887 -
|
||||
# 9 Short offline Completed without error 00% 10857 -
|
||||
#10 Short offline Completed without error 00% 10851 -
|
||||
#11 Short offline Completed without error 00% 10843 -
|
||||
#12 Short offline Completed without error 00% 10833 -
|
||||
#13 Extended offline Completed without error 00% 10832 -
|
||||
#14 Short offline Completed without error 00% 10819 -
|
||||
#15 Short offline Completed without error 00% 10817 -
|
||||
#16 Short offline Completed without error 00% 10816 -
|
||||
#17 Short offline Completed without error 00% 10813 -
|
||||
#18 Short offline Completed without error 00% 10801 -
|
||||
#19 Short offline Completed without error 00% 10799 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/30 Celsius
|
||||
Lifetime Min/Max Temperature: 8/55 Celsius
|
||||
Specified Max Operating Temperature: 38 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (17)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
Write: 85 (8.5 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 0 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
||||
250
HDD/HGST/HTS5410/HTS541075A7E630/AD3BF90AF280
Normal file
250
HDD/HGST/HTS5410/HTS541075A7E630/AD3BF90AF280
Normal file
@@ -0,0 +1,250 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: HGST Travelstar Z5K1000
|
||||
Device Model: HGST HTS541075A7E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: SE2OA4A0
|
||||
User Capacity: 750,156,374,016 bytes [750 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue May 26 04:54:56 2020 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x51) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 165) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--K 100 100 040 - 0
|
||||
3 Spin_Up_Time PO---K 116 100 033 - 1
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 2902
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate POSR-K 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--K 100 100 040 - 0
|
||||
9 Power_On_Hours -O--CK 090 090 000 - 4489
|
||||
10 Spin_Retry_Count PO--CK 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 2899
|
||||
183 Runtime_Bad_Block -O--CK 100 100 001 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 458753
|
||||
188 Command_Timeout -O--CK 100 100 000 - 4295099171
|
||||
190 Airflow_Temperature_Cel -O---K 074 054 045 - 26 (Min/Max 21/31)
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 25832
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 7602292
|
||||
193 Load_Cycle_Count -O--CK 088 088 000 - 127842
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 3
|
||||
223 Load_Retry_Count -O-R-K 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
Device Error Count: 4
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 4 [3] occurred at disk power-on lifetime: 4488 hours (187 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 41 00 10 00 00 2b 4a ec 18 0b 00 Error: ICRC, ABRT at LBA = 0x2b4aec18 = 726330392
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 01 00 00 01 00 00 00 00 00 01 a0 ff 00:27:01.886 WRITE FPDMA QUEUED
|
||||
61 01 00 00 10 00 00 2b 4a ec 17 4b ff 00:27:01.885 WRITE FPDMA QUEUED
|
||||
61 01 00 00 a0 00 00 2b 4a f0 28 40 00 00:27:01.885 WRITE FPDMA QUEUED
|
||||
61 01 00 00 98 00 00 2b 4a ef 28 40 00 00:27:01.884 WRITE FPDMA QUEUED
|
||||
61 01 00 00 90 00 00 2b 4a ee 28 40 00 00:27:01.882 WRITE FPDMA QUEUED
|
||||
|
||||
Error 3 [2] occurred at disk power-on lifetime: 4462 hours (185 days + 22 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 41 00 01 00 00 03 d8 7e e7 03 00 Error: ICRC, ABRT at LBA = 0x03d87ee7 = 64519911
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 01 00 00 01 00 00 00 00 00 01 a0 ff 00:04:22.181 WRITE FPDMA QUEUED
|
||||
61 01 00 00 00 00 00 03 d8 7e e7 43 ff 00:04:22.180 WRITE FPDMA QUEUED
|
||||
61 01 00 00 90 00 00 03 d8 7d e8 40 00 00:04:22.180 WRITE FPDMA QUEUED
|
||||
61 01 00 00 88 00 00 03 d8 7c e8 40 00 00:04:21.842 WRITE FPDMA QUEUED
|
||||
61 01 00 00 80 00 00 03 d8 7b a8 40 00 00:04:21.842 WRITE FPDMA QUEUED
|
||||
|
||||
Error 2 [1] occurred at disk power-on lifetime: 4310 hours (179 days + 14 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 41 01 00 00 00 0b 96 dc a8 0b 00 Error: IDNF at LBA = 0x0b96dca8 = 194436264
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 01 00 00 40 00 00 0b 96 dc a8 40 00 00:12:13.095 WRITE FPDMA QUEUED
|
||||
ec 00 00 00 01 00 00 00 00 00 01 00 04 00:11:56.467 IDENTIFY DEVICE
|
||||
ec 00 00 00 01 00 00 00 00 00 01 a0 ff 00:11:24.273 IDENTIFY DEVICE
|
||||
ec 00 00 00 01 00 00 00 00 00 00 40 ff 00:11:24.273 IDENTIFY DEVICE
|
||||
ec 00 00 00 00 00 00 00 00 00 00 40 00 00:10:54.261 IDENTIFY DEVICE
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 4310 hours (179 days + 14 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 41 01 00 00 00 0b 96 db a8 0b 00 Error: ICRC, ABRT at LBA = 0x0b96dba8 = 194436008
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 01 00 00 20 00 00 0b 96 de a8 40 00 00:05:42.641 WRITE FPDMA QUEUED
|
||||
61 01 00 00 18 00 00 0b 96 dd a8 40 00 00:05:42.641 WRITE FPDMA QUEUED
|
||||
61 01 00 00 10 00 00 0b 96 dc a8 40 00 00:05:42.641 WRITE FPDMA QUEUED
|
||||
61 01 00 00 08 00 00 0b 96 db a8 40 00 00:05:42.641 WRITE FPDMA QUEUED
|
||||
ef 00 02 00 00 00 00 00 00 00 00 40 00 00:05:42.641 SET FEATURES [Enable write cache]
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 1350 -
|
||||
# 2 Short offline Completed without error 00% 1306 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/31 Celsius
|
||||
Lifetime Min/Max Temperature: 15/46 Celsius
|
||||
Specified Max Operating Temperature: 31 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (73)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
Write: 85 (8.5 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 266 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 266 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 1 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 1 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 271 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 271 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 185 CRC errors within host-to-device FIS
|
||||
0x000d 2 265 Non-CRC errors within host-to-device FIS
|
||||
|
||||
163
HDD/HGST/HTS7210/HTS721010A9E630/0E802F163734
Normal file
163
HDD/HGST/HTS7210/HTS721010A9E630/0E802F163734
Normal file
@@ -0,0 +1,163 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: HGST Travelstar 7K1000
|
||||
Device Model: HGST HTS721010A9E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: JB0OA3J0
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 2 03:47:41 2020 HDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 175) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 161 161 040 - 97
|
||||
3 Spin_Up_Time POS--- 121 121 033 - 2
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 97
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 138 138 040 - 34
|
||||
9 Power_On_Hours -O--C- 100 100 000 - 93
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 96
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 5
|
||||
193 Load_Cycle_Count -O--C- 100 100 000 - 615
|
||||
194 Temperature_Celsius -O---- 127 127 000 - 47 (Min/Max 10/52)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 47 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/47 Celsius
|
||||
Lifetime Min/Max Temperature: 10/52 Celsius
|
||||
Specified Max Operating Temperature: 40 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (38)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 9 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
165
HDD/HGST/HTS7210/HTS721010A9E630/DCF1A8E71D52
Normal file
165
HDD/HGST/HTS7210/HTS721010A9E630/DCF1A8E71D52
Normal file
@@ -0,0 +1,165 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 13.0-CURRENT amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: HGST Travelstar 7K1000
|
||||
Device Model: HGST HTS721010A9E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: JB0OA3V0
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue May 26 13:19:29 2020 +04
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 164) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 119 119 033 - 2
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 1266
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 077 077 000 - 10160
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1258
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 28
|
||||
193 Load_Cycle_Count -O--C- 041 041 000 - 596963
|
||||
194 Temperature_Celsius -O---- 171 171 000 - 35 (Min/Max 17/52)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short captive Completed without error 00% 149 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/36 Celsius
|
||||
Lifetime Min/Max Temperature: 17/52 Celsius
|
||||
Specified Max Operating Temperature: 37 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (42)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
||||
164
HDD/HGST/HTS7250/HTS725050A7E630/AFF6E8E2A505
Normal file
164
HDD/HGST/HTS7250/HTS725050A7E630/AFF6E8E2A505
Normal file
@@ -0,0 +1,164 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z7K500
|
||||
Device Model: HGST HTS725050A7E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GH2ZB550
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed May 27 16:30:57 2020 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 90) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 216 216 033 - 1
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 642
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 091 091 000 - 4217
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 636
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 7
|
||||
193 Load_Cycle_Count -O--C- 091 091 000 - 92714
|
||||
194 Temperature_Celsius -O---- 176 176 000 - 34 (Min/Max 8/49)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0x50) Completed without error 00% 3620 -
|
||||
# 2 Short offline Completed without error 00% 3620 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/35 Celsius
|
||||
Lifetime Min/Max Temperature: 8/49 Celsius
|
||||
Specified Max Operating Temperature: 33 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (40)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 22 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 17 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
45
HDD/HGST/README.md
Normal file
45
HDD/HGST/README.md
Normal file
@@ -0,0 +1,45 @@
|
||||
HGST Hard Drives
|
||||
================
|
||||
|
||||
This is a list of all tested HGST hard drive models and their MTBFs. See more
|
||||
info on reliability test in the [README](https://github.com/bsdhw/SMART).
|
||||
|
||||
Contents
|
||||
--------
|
||||
|
||||
1. [ HDD by Model ](#hdd-by-model)
|
||||
2. [ HDD by Family ](#hdd-by-family)
|
||||
|
||||
HDD by Model
|
||||
------------
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Model | Size | Samples | Days | Err | MTBF |
|
||||
|-----------|--------------------|--------|---------|-------|-------|--------|
|
||||
| HGST | HTS541075A7E630 | 752 GB | 2 | 321 | 507 | 0.62 |
|
||||
| HGST | HTS721010A9E630 | 1 TB | 2 | 213 | 0 | 0.59 |
|
||||
| HGST | HTS725050A7E630 | 500 GB | 1 | 175 | 0 | 0.48 |
|
||||
|
||||
HDD by Family
|
||||
-------------
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Family | Models | Samples | Days | Err | MTBF |
|
||||
|-----------|------------------------|--------|---------|-------|-------|--------|
|
||||
| HGST | Travelstar Z5K1000 | 1 | 2 | 321 | 507 | 0.62 |
|
||||
| HGST | Travelstar 7K1000 | 1 | 2 | 213 | 0 | 0.59 |
|
||||
| HGST | Travelstar Z7K500 | 1 | 1 | 175 | 0 | 0.48 |
|
||||
198
HDD/Hitachi/HDS7210/HDS721010CLA332/64970F0E967D
Normal file
198
HDD/Hitachi/HDS7210/HDS721010CLA332/64970F0E967D
Normal file
@@ -0,0 +1,198 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [i386-unknown-openbsd6.7] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Deskstar 7K1000.C
|
||||
Device Model: HDS721010CLA332
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: JP4OA3MA
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Mon May 25 16:25:48 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (10517) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 175) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x000b 094 094 016 Pre-fail Always - 786448
|
||||
2 Throughput_Performance 0x0005 135 135 054 Pre-fail Offline - 97
|
||||
3 Spin_Up_Time 0x0007 120 120 024 Pre-fail Always - 315 (Average 315)
|
||||
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 395
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 106
|
||||
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
|
||||
8 Seek_Time_Performance 0x0005 140 140 020 Pre-fail Offline - 30
|
||||
9 Power_On_Hours 0x0012 095 095 000 Old_age Always - 36284
|
||||
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
|
||||
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 388
|
||||
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 395
|
||||
193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 395
|
||||
194 Temperature_Celsius 0x0002 222 222 000 Old_age Always - 27 (Min/Max 19/59)
|
||||
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 109
|
||||
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
|
||||
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
|
||||
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
|
||||
|
||||
SMART Error Log Version: 1
|
||||
ATA Error Count: 2327 (device log contains only the most recent five errors)
|
||||
CR = Command Register [HEX]
|
||||
FR = Features Register [HEX]
|
||||
SC = Sector Count Register [HEX]
|
||||
SN = Sector Number Register [HEX]
|
||||
CL = Cylinder Low Register [HEX]
|
||||
CH = Cylinder High Register [HEX]
|
||||
DH = Device/Head Register [HEX]
|
||||
DC = Device Command Register [HEX]
|
||||
ER = Error register [HEX]
|
||||
ST = Status register [HEX]
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 2327 occurred at disk power-on lifetime: 35833 hours (1493 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 51 01 03 68 44 00 Error: UNC 1 sectors at LBA = 0x00446803 = 4483075
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
c8 00 01 03 68 44 e0 08 15d+21:37:03.784 READ DMA
|
||||
c8 00 01 02 68 44 e0 08 15d+21:37:03.740 READ DMA
|
||||
c8 00 01 01 68 44 e0 08 15d+21:37:03.738 READ DMA
|
||||
c8 00 01 00 68 44 e0 08 15d+21:37:03.643 READ DMA
|
||||
27 00 00 00 00 00 e0 08 15d+21:37:03.641 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
|
||||
Error 2326 occurred at disk power-on lifetime: 35833 hours (1493 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 51 fd 03 68 44 00 Error: UNC 253 sectors at LBA = 0x00446803 = 4483075
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
25 00 00 00 68 44 e0 08 15d+21:36:45.378 READ DMA EXT
|
||||
25 00 00 00 66 44 e0 08 15d+21:36:45.368 READ DMA EXT
|
||||
25 00 00 00 64 44 e0 08 15d+21:36:45.350 READ DMA EXT
|
||||
25 00 00 00 62 44 e0 08 15d+21:36:45.340 READ DMA EXT
|
||||
25 00 00 00 60 44 e0 08 15d+21:36:45.331 READ DMA EXT
|
||||
|
||||
Error 2325 occurred at disk power-on lifetime: 35833 hours (1493 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 51 01 ce c9 42 00 Error: UNC 1 sectors at LBA = 0x0042c9ce = 4377038
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
c8 00 01 ce c9 42 e0 08 15d+21:34:12.207 READ DMA
|
||||
c8 00 01 cd c9 42 e0 08 15d+21:34:12.206 READ DMA
|
||||
c8 00 01 cc c9 42 e0 08 15d+21:34:12.205 READ DMA
|
||||
c8 00 01 cb c9 42 e0 08 15d+21:34:12.204 READ DMA
|
||||
c8 00 01 ca c9 42 e0 08 15d+21:34:12.203 READ DMA
|
||||
|
||||
Error 2324 occurred at disk power-on lifetime: 35833 hours (1493 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 51 32 ce c9 42 00 Error: UNC 50 sectors at LBA = 0x0042c9ce = 4377038
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
25 00 00 00 c8 42 e0 08 15d+21:33:53.508 READ DMA EXT
|
||||
25 00 00 00 c6 42 e0 08 15d+21:33:53.491 READ DMA EXT
|
||||
25 00 00 00 c4 42 e0 08 15d+21:33:53.481 READ DMA EXT
|
||||
25 00 00 00 c2 42 e0 08 15d+21:33:53.472 READ DMA EXT
|
||||
25 00 00 00 c0 42 e0 08 15d+21:33:53.309 READ DMA EXT
|
||||
|
||||
Error 2323 occurred at disk power-on lifetime: 35833 hours (1493 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 51 01 03 68 44 00 Error: UNC 1 sectors at LBA = 0x00446803 = 4483075
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
c8 00 01 03 68 44 e0 08 15d+20:19:15.685 READ DMA
|
||||
c8 00 01 02 68 44 e0 08 15d+20:19:15.641 READ DMA
|
||||
c8 00 01 01 68 44 e0 08 15d+20:19:15.639 READ DMA
|
||||
c8 00 01 00 68 44 e0 08 15d+20:19:15.542 READ DMA
|
||||
27 00 00 00 00 00 e0 08 15d+20:19:15.539 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 36120 -
|
||||
# 2 Extended offline Completed without error 00% 35999 -
|
||||
# 3 Extended offline Completed without error 00% 35945 -
|
||||
# 4 Short offline Completed without error 00% 35919 -
|
||||
# 5 Extended offline Completed without error 00% 35860 -
|
||||
# 6 Extended offline Interrupted (host reset) 90% 35857 -
|
||||
# 7 Short offline Completed without error 00% 35841 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
146
HDD/Hitachi/HDS7216/HDS721616PLAT80/120676B117DD
Normal file
146
HDD/Hitachi/HDS7216/HDS721616PLAT80/120676B117DD
Normal file
@@ -0,0 +1,146 @@
|
||||
smartctl 6.6 2017-11-05 r4594 [FreeBSD 10.3-RELEASE-p11 i386] (local build)
|
||||
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Deskstar 7K160
|
||||
Device Model: HDS721616PLAT80
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: P22OA8BA
|
||||
User Capacity: 160,041,885,696 bytes [160 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
|
||||
Local Time is: Fri May 29 12:22:14 2020 JST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 2865) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 48) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 65536
|
||||
2 Throughput_Performance P-S--- 100 100 050 - 0
|
||||
3 Spin_Up_Time POS--- 121 121 024 - 165 (Average 164)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 1719
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 020 - 0
|
||||
9 Power_On_Hours -O--C- 093 093 000 - 52489
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1590
|
||||
192 Power-Off_Retract_Count -O--CK 097 097 000 - 3732
|
||||
193 Load_Cycle_Count -O--C- 097 097 000 - 3732
|
||||
194 Temperature_Celsius -O---- 142 142 000 - 42 (Min/Max 5/51)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 78
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
SCT Support Level: 1
|
||||
Device State: Active (0)
|
||||
Current Temperature: 42 Celsius
|
||||
Power Cycle Max Temperature: 51 Celsius
|
||||
Lifetime Max Temperature: 51 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (3)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
||||
|
||||
|
||||
165
HDD/Hitachi/HDS7250/HDS725050KLA360/A9CFD2B26630
Normal file
165
HDD/Hitachi/HDS7250/HDS725050KLA360/A9CFD2B26630
Normal file
@@ -0,0 +1,165 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Deskstar 7K500
|
||||
Device Model: HDS725050KLA360
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: K2ABCD5A
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
|
||||
Local Time is: Thu May 28 09:20:53 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (10419) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 174) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 050 - 0
|
||||
3 Spin_Up_Time POS--- 104 104 024 - 699 (Average 646)
|
||||
4 Start_Stop_Count -O--C- 094 094 000 - 27275
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 020 - 0
|
||||
9 Power_On_Hours -O--C- 088 088 000 - 90316
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 3372
|
||||
192 Power-Off_Retract_Count -O--CK 075 075 050 - 30466
|
||||
193 Load_Cycle_Count -O--C- 075 075 050 - 30466
|
||||
194 Temperature_Celsius -O---- 134 134 000 - 41 (Min/Max 12/56)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 24676 -
|
||||
# 2 Extended offline Completed without error 00% 24540 -
|
||||
# 3 Short offline Completed without error 00% 24513 -
|
||||
# 4 Short offline Completed without error 00% 24345 -
|
||||
# 5 Short offline Completed without error 00% 24177 -
|
||||
# 6 Short offline Completed without error 00% 24009 -
|
||||
# 7 Short offline Completed without error 00% 23841 -
|
||||
# 8 Extended offline Completed without error 00% 23820 -
|
||||
# 9 Short offline Completed without error 00% 23673 -
|
||||
#10 Short offline Completed without error 00% 23505 -
|
||||
#11 Short offline Completed without error 00% 23337 -
|
||||
#12 Short offline Completed without error 00% 23169 -
|
||||
#13 Extended offline Completed without error 00% 23076 -
|
||||
#14 Short offline Completed without error 00% 23001 -
|
||||
#15 Short offline Completed without error 00% 22834 -
|
||||
#16 Short offline Completed without error 00% 22671 -
|
||||
#17 Short offline Completed without error 00% 22503 -
|
||||
#18 Extended offline Completed without error 00% 22386 -
|
||||
|
||||
Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: --/49 Celsius
|
||||
Lifetime Min/Max Temperature: --/56 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (120)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
||||
|
||||
|
||||
152
HDD/Hitachi/HDT7250/HDT725025VLA380/22A6C9E780BF
Normal file
152
HDD/Hitachi/HDT7250/HDT725025VLA380/22A6C9E780BF
Normal file
@@ -0,0 +1,152 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Deskstar T7K500
|
||||
Device Model: HDT725025VLA380
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: V5DOA7EA
|
||||
User Capacity: 250,059,350,016 bytes [250 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
|
||||
Local Time is: Mon May 25 14:02:08 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 4949) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 83) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 050 - 0
|
||||
3 Spin_Up_Time POS--- 121 121 024 - 306 (Average 309)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 842
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 020 - 0
|
||||
9 Power_On_Hours -O--C- 091 091 000 - 64336
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 840
|
||||
192 Power-Off_Retract_Count -O--CK 098 098 000 - 3374
|
||||
193 Load_Cycle_Count -O--C- 098 098 000 - 3374
|
||||
194 Temperature_Celsius -O---- 250 250 000 - 24 (Min/Max 11/54)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short captive Completed without error 00% 9092 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 24 Celsius
|
||||
Power Cycle Min/Max Temperature: --/28 Celsius
|
||||
Lifetime Min/Max Temperature: --/54 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (31)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
194
HDD/Hitachi/HTC4260/HTC426060G9AT00/6C6B7515F5C2
Normal file
194
HDD/Hitachi/HTC4260/HTC426060G9AT00/6C6B7515F5C2
Normal file
@@ -0,0 +1,194 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [i386-unknown-openbsd6.7] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: HTC426060G9AT00
|
||||
Serial Number: --
|
||||
Firmware Version: 00P3A0B5
|
||||
User Capacity: 60,011,642,880 bytes [60.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ATA/ATAPI-6 T13/1410D revision 3a
|
||||
Local Time is: Mon May 25 17:03:27 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 73) The previous self-test completed having
|
||||
a test element that failed and the test
|
||||
element that failed is not known.
|
||||
Total time to complete Offline
|
||||
data collection: ( 3260) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
No General Purpose Logging support.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 55) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x000d 100 100 050 Pre-fail Offline - 0
|
||||
2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0
|
||||
3 Spin_Up_Time 0x0007 100 100 050 Pre-fail Always - 0
|
||||
4 Start_Stop_Count 0x0032 094 094 000 Old_age Always - 6029
|
||||
5 Reallocated_Sector_Ct 0x0033 001 001 010 Pre-fail Always FAILING_NOW 2020
|
||||
7 Seek_Error_Rate 0x000f 100 100 050 Pre-fail Always - 524
|
||||
8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0
|
||||
9 Power_On_Hours 0x0032 064 064 000 Old_age Always - 1090804
|
||||
10 Spin_Retry_Count 0x0013 100 100 050 Pre-fail Always - 0
|
||||
12 Power_Cycle_Count 0x0032 096 096 000 Old_age Always - 4562
|
||||
191 G-Sense_Error_Rate 0x000a 100 078 000 Old_age Always - 4294967295
|
||||
192 Power-Off_Retract_Count 0x0032 099 099 000 Old_age Always - 725
|
||||
193 Load_Cycle_Count 0x0032 080 080 000 Old_age Always - 2031016336312
|
||||
194 Temperature_Celsius 0x0022 100 062 000 Old_age Always - 39 (Min/Max 11/59)
|
||||
195 Hardware_ECC_Recovered 0x001a 100 001 000 Old_age Always - 19206
|
||||
196 Reallocated_Event_Count 0x0032 001 001 000 Old_age Always - 2020
|
||||
197 Current_Pending_Sector 0x0032 075 001 000 Old_age Always - 25
|
||||
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
|
||||
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
|
||||
200 Multi_Zone_Error_Rate 0x0013 100 100 050 Pre-fail Always - 0
|
||||
201 Soft_Read_Error_Rate 0x0012 087 087 000 Old_age Always - 136
|
||||
223 Load_Retry_Count 0x0012 100 100 000 Old_age Always - 0
|
||||
230 Head_Amplitude 0x0032 067 067 000 Old_age Always - 1001351
|
||||
250 Read_Error_Retry_Rate 0x000a 100 001 000 Old_age Always - 995
|
||||
|
||||
SMART Error Log Version: 1
|
||||
ATA Error Count: 35803 (device log contains only the most recent five errors)
|
||||
CR = Command Register [HEX]
|
||||
FR = Features Register [HEX]
|
||||
SC = Sector Count Register [HEX]
|
||||
SN = Sector Number Register [HEX]
|
||||
CL = Cylinder Low Register [HEX]
|
||||
CH = Cylinder High Register [HEX]
|
||||
DH = Device/Head Register [HEX]
|
||||
DC = Device Command Register [HEX]
|
||||
ER = Error register [HEX]
|
||||
ST = Status register [HEX]
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 35803 occurred at disk power-on lifetime: 18159 hours (756 days + 15 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 51 04 d4 c0 83 e0 Error: UNC 4 sectors at LBA = 0x0083c0d4 = 8634580
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
c8 00 08 d0 c0 83 e0 00 01:33:44.630 READ DMA
|
||||
e5 00 00 00 00 00 00 00 01:33:44.630 CHECK POWER MODE
|
||||
ca 00 08 70 81 17 e4 00 01:33:44.620 WRITE DMA
|
||||
ca 00 08 00 80 0f e4 00 01:33:44.610 WRITE DMA
|
||||
ca 00 08 18 02 90 e3 00 01:33:44.600 WRITE DMA
|
||||
|
||||
Error 35802 occurred at disk power-on lifetime: 18159 hours (756 days + 15 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 51 04 d4 c0 83 e0 Error: UNC 4 sectors at LBA = 0x0083c0d4 = 8634580
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
c8 00 08 d0 c0 83 e0 00 01:33:41.730 READ DMA
|
||||
c8 00 08 c8 c0 83 e0 00 01:33:41.730 READ DMA
|
||||
c8 00 08 c0 c0 83 e0 00 01:33:41.730 READ DMA
|
||||
c8 00 08 b8 c0 83 e0 00 01:33:41.730 READ DMA
|
||||
c8 00 08 b0 c0 83 e0 00 01:33:41.730 READ DMA
|
||||
|
||||
Error 35801 occurred at disk power-on lifetime: 18159 hours (756 days + 15 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 51 08 f8 41 62 e0 Error: UNC 8 sectors at LBA = 0x006241f8 = 6439416
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
c8 00 08 f8 41 62 e0 00 01:33:30.980 READ DMA
|
||||
e5 00 00 00 00 00 00 00 01:33:30.980 CHECK POWER MODE
|
||||
f8 00 00 00 00 00 e0 00 01:33:30.980 READ NATIVE MAX ADDRESS [OBS-ACS-3]
|
||||
ec 00 00 00 00 00 a0 00 01:33:30.980 IDENTIFY DEVICE
|
||||
ef 03 45 00 00 00 a0 00 01:33:30.980 SET FEATURES [Set transfer mode]
|
||||
|
||||
Error 35800 occurred at disk power-on lifetime: 18159 hours (756 days + 15 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 51 08 f8 41 62 e0 Error: UNC 8 sectors at LBA = 0x006241f8 = 6439416
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
c8 00 08 f8 41 62 e0 00 01:33:28.230 READ DMA
|
||||
c8 00 08 f0 41 62 e0 00 01:33:28.230 READ DMA
|
||||
c8 00 08 e8 41 62 e0 00 01:33:28.230 READ DMA
|
||||
c8 00 08 e0 41 62 e0 00 01:33:28.230 READ DMA
|
||||
c8 00 08 d8 41 62 e0 00 01:33:28.230 READ DMA
|
||||
|
||||
Error 35799 occurred at disk power-on lifetime: 18159 hours (756 days + 15 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 51 03 75 32 62 e0 Error: UNC 3 sectors at LBA = 0x00623275 = 6435445
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
c8 00 08 70 32 62 e0 00 01:33:23.960 READ DMA
|
||||
c8 00 08 68 32 62 e0 00 01:33:23.960 READ DMA
|
||||
c8 00 08 60 32 62 e0 00 01:33:23.950 READ DMA
|
||||
c8 00 08 58 32 62 e0 00 01:33:23.950 READ DMA
|
||||
c8 00 08 50 32 62 e0 00 01:33:23.950 READ DMA
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed: unknown failure 90% 17415 0
|
||||
# 2 Short offline Completed: unknown failure 90% 17147 0
|
||||
# 3 Short offline Completed: unknown failure 90% 17147 0
|
||||
# 4 Extended offline Completed: unknown failure 90% 17147 0
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
220
HDD/Hitachi/HTS4212/HTS421260H9AT00/B3561755EAE1
Normal file
220
HDD/Hitachi/HTS4212/HTS421260H9AT00/B3561755EAE1
Normal file
@@ -0,0 +1,220 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 i386] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Travelstar 4K120
|
||||
Device Model: HTS421260H9AT00
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: HA2OA70S
|
||||
User Capacity: 60,011,642,880 bytes [60.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
|
||||
Local Time is: Tue May 26 13:17:44 2020 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 645) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 47) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 227 227 033 - 1
|
||||
4 Start_Stop_Count -O--C- 083 083 000 - 28164
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 027 027 000 - 32129
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 092 092 000 - 12941
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 65536
|
||||
192 Power-Off_Retract_Count -O--CK 095 095 000 - 1081
|
||||
193 Load_Cycle_Count -O--C- 049 049 000 - 513420
|
||||
194 Temperature_Celsius -O---- 117 117 000 - 47 (Min/Max 9/58)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 8
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
Device Error Count: 144 (device log contains only the most recent 4 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 144 [3] occurred at disk power-on lifetime: 24607 hours (1025 days + 7 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 3a 00 00 01 61 bd 2e e1 00 Error: UNC 58 sectors at LBA = 0x0161bd2e = 23182638
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
c8 00 00 00 40 61 ba e7 61 bd 28 e1 00 04:43:14.200 READ DMA
|
||||
c8 00 00 00 40 61 b2 e7 61 ba a8 e1 00 04:43:14.200 READ DMA
|
||||
c8 00 00 00 40 61 b2 a7 61 b2 a8 e1 00 04:43:14.200 READ DMA
|
||||
c8 00 00 00 00 61 b0 e7 61 b1 a8 e1 00 04:43:14.200 READ DMA
|
||||
c8 00 00 00 40 61 b0 a7 61 b0 a8 e1 00 04:43:14.200 READ DMA
|
||||
|
||||
Error 143 [2] occurred at disk power-on lifetime: 21799 hours (908 days + 7 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 01 13 97 00 13 97 0a e0 00 Error: UNC 1 sectors at LBA = 0x13970013970a = 21539262273290
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
c8 00 00 01 01 13 97 0a 13 97 0a e0 00 00:02:15.500 READ DMA
|
||||
c8 00 00 01 01 13 97 0a 13 97 0a e0 00 00:02:10.600 READ DMA
|
||||
c8 00 00 01 01 13 97 0a 13 97 0a e0 00 00:02:05.700 READ DMA
|
||||
c8 00 00 01 01 13 97 0a 13 97 0a e0 00 00:02:00.700 READ DMA
|
||||
c8 00 00 00 01 13 97 09 13 97 0a e0 00 00:01:55.800 READ DMA
|
||||
|
||||
Error 142 [1] occurred at disk power-on lifetime: 21799 hours (908 days + 7 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 01 13 97 00 13 97 0a e0 00 Error: UNC 1 sectors at LBA = 0x13970013970a = 21539262273290
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
c8 00 00 01 01 13 97 0a 13 97 0a e0 00 00:02:10.600 READ DMA
|
||||
c8 00 00 01 01 13 97 0a 13 97 0a e0 00 00:02:05.700 READ DMA
|
||||
c8 00 00 01 01 13 97 0a 13 97 0a e0 00 00:02:00.700 READ DMA
|
||||
c8 00 00 00 01 13 97 09 13 97 0a e0 00 00:01:55.800 READ DMA
|
||||
c8 00 00 00 01 13 97 08 13 97 09 e0 00 00:01:55.800 READ DMA
|
||||
|
||||
Error 141 [0] occurred at disk power-on lifetime: 21799 hours (908 days + 7 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 01 13 97 00 13 97 0a e0 00 Error: UNC 1 sectors at LBA = 0x13970013970a = 21539262273290
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
c8 00 00 01 01 13 97 0a 13 97 0a e0 00 00:02:05.700 READ DMA
|
||||
c8 00 00 01 01 13 97 0a 13 97 0a e0 00 00:02:00.700 READ DMA
|
||||
c8 00 00 00 01 13 97 09 13 97 0a e0 00 00:01:55.800 READ DMA
|
||||
c8 00 00 00 01 13 97 08 13 97 09 e0 00 00:01:55.800 READ DMA
|
||||
c8 00 00 00 01 13 97 07 13 97 08 e0 00 00:01:55.800 READ DMA
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 32035 -
|
||||
# 2 Short offline Completed without error 00% 31950 -
|
||||
# 3 Short offline Completed without error 00% 31657 -
|
||||
# 4 Short offline Completed without error 00% 31506 -
|
||||
# 5 Extended offline Completed without error 00% 31328 -
|
||||
# 6 Short offline Completed without error 00% 30826 -
|
||||
# 7 Extended offline Completed without error 00% 30590 -
|
||||
# 8 Short offline Completed without error 00% 30167 -
|
||||
# 9 Short offline Completed without error 00% 30009 -
|
||||
#10 Short offline Completed without error 00% 29888 -
|
||||
#11 Extended offline Completed without error 00% 29566 -
|
||||
#12 Short offline Completed without error 00% 28985 -
|
||||
#13 Short offline Completed without error 00% 28694 -
|
||||
#14 Short offline Completed without error 00% 28486 -
|
||||
#15 Short offline Completed without error 00% 28256 -
|
||||
#16 Short offline Completed without error 00% 27968 -
|
||||
#17 Extended offline Aborted by host 90% 27935 -
|
||||
#18 Short offline Completed without error 00% 27480 -
|
||||
|
||||
Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
||||
129
HDD/Hitachi/HTS5416/HTS541660J9SA00/290A83280B81
Normal file
129
HDD/Hitachi/HTS5416/HTS541660J9SA00/290A83280B81
Normal file
@@ -0,0 +1,129 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Travelstar 5K160
|
||||
Device Model: HTS541660J9SA00
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: SBBIC7UP
|
||||
User Capacity: 60,011,642,880 bytes [60.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
|
||||
Local Time is: Mon May 25 14:30:08 2020 IST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 645) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 39) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 105 105 040 - 4569
|
||||
3 Spin_Up_Time POS--- 253 253 033 - 0
|
||||
4 Start_Stop_Count -O--C- 099 099 000 - 1850
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 128 128 040 - 36
|
||||
9 Power_On_Hours -O--C- 072 072 000 - 12420
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1742
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 97976345
|
||||
193 Load_Cycle_Count -O--C- 088 088 000 - 126906
|
||||
194 Temperature_Celsius -O---- 130 130 000 - 42 (Min/Max 9/52)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 253 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0009 2 4324 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
96
HDD/Hitachi/HTS5432/HTS543212L9A300/9458ABA347BE
Normal file
96
HDD/Hitachi/HTS5432/HTS543212L9A300/9458ABA347BE
Normal file
@@ -0,0 +1,96 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [DragonFly 5.8-RELEASE x86_64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Travelstar 5K320
|
||||
Device Model: HTS543212L9A300
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: FBBOC40C
|
||||
User Capacity: 120,034,123,776 bytes [120 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 3f
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Thu May 28 11:58:17 2020 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART Status not supported: Incomplete response, ATA output registers missing
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
Warning: This result is based on an Attribute check.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 645) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 52) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x000b 100 100 062 Pre-fail Always - 0
|
||||
2 Throughput_Performance 0x0005 107 107 040 Pre-fail Offline - 4467
|
||||
3 Spin_Up_Time 0x0007 253 253 033 Pre-fail Always - 0
|
||||
4 Start_Stop_Count 0x0012 099 099 000 Old_age Always - 3059
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
|
||||
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
|
||||
8 Seek_Time_Performance 0x0005 128 128 040 Pre-fail Offline - 36
|
||||
9 Power_On_Hours 0x0012 037 037 000 Old_age Always - 27793
|
||||
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
|
||||
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 3014
|
||||
191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age Always - 0
|
||||
192 Power-Off_Retract_Count 0x0032 099 099 000 Old_age Always - 302
|
||||
193 Load_Cycle_Count 0x0012 001 001 000 Old_age Always - 5088635
|
||||
194 Temperature_Celsius 0x0002 157 157 000 Old_age Always - 35 (Min/Max 8/56)
|
||||
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 88
|
||||
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
|
||||
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
|
||||
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 4
|
||||
223 Load_Retry_Count 0x000a 100 100 000 Old_age Always - 0
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
221
HDD/Hitachi/HTS7210/HTS721060G9AT00/73147CBA22BD
Normal file
221
HDD/Hitachi/HTS7210/HTS721060G9AT00/73147CBA22BD
Normal file
@@ -0,0 +1,221 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [i386-unknown-openbsd6.6] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Travelstar 7K100
|
||||
Device Model: HTS721060G9AT00
|
||||
Serial Number: --
|
||||
Firmware Version: MC3IA51A
|
||||
User Capacity: 60,011,642,880 bytes [60.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-6 T13/1410D revision 3a
|
||||
Local Time is: Wed May 6 09:42:20 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 645) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
No General Purpose Logging support.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 35) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 172 172 033 - 1
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 17
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 100 100 000 - 5
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 17
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 28442626
|
||||
193 Load_Cycle_Count -O--C- 100 100 000 - 71
|
||||
194 Temperature_Celsius -O---- 137 137 000 - 40 (Min/Max 23/45)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 37
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory not supported
|
||||
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x80-0x9f SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log Version: 1
|
||||
ATA Error Count: 2517 (device log contains only the most recent five errors)
|
||||
CR = Command Register [HEX]
|
||||
FR = Features Register [HEX]
|
||||
SC = Sector Count Register [HEX]
|
||||
SN = Sector Number Register [HEX]
|
||||
CL = Cylinder Low Register [HEX]
|
||||
CH = Cylinder High Register [HEX]
|
||||
DH = Device/Head Register [HEX]
|
||||
DC = Device Command Register [HEX]
|
||||
ER = Error register [HEX]
|
||||
ST = Status register [HEX]
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 2517 occurred at disk power-on lifetime: 3924 hours (163 days + 12 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
10 51 01 68 9a de ef Error: IDNF 1 sectors at LBA = 0x0fde9a68 = 266246760
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
c8 ff 01 68 9a de ef 00 00:15:44.100 READ DMA
|
||||
c8 ff 01 67 9a de ef 00 00:15:44.100 READ DMA
|
||||
c8 ff 01 66 9a de ef 00 00:15:44.100 READ DMA
|
||||
c8 ff 01 65 9a de ef 00 00:15:44.000 READ DMA
|
||||
c8 ff 01 64 9a de ef 00 00:15:44.000 READ DMA
|
||||
|
||||
Error 2516 occurred at disk power-on lifetime: 3924 hours (163 days + 12 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
10 51 01 67 9a de ef Error: IDNF 1 sectors at LBA = 0x0fde9a67 = 266246759
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
c8 ff 01 67 9a de ef 00 00:15:44.100 READ DMA
|
||||
c8 ff 01 66 9a de ef 00 00:15:44.100 READ DMA
|
||||
c8 ff 01 65 9a de ef 00 00:15:44.000 READ DMA
|
||||
c8 ff 01 64 9a de ef 00 00:15:44.000 READ DMA
|
||||
c8 ff 01 63 9a de ef 00 00:15:44.000 READ DMA
|
||||
|
||||
Error 2515 occurred at disk power-on lifetime: 3924 hours (163 days + 12 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
10 51 01 66 9a de ef Error: IDNF 1 sectors at LBA = 0x0fde9a66 = 266246758
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
c8 ff 01 66 9a de ef 00 00:15:44.100 READ DMA
|
||||
c8 ff 01 65 9a de ef 00 00:15:44.000 READ DMA
|
||||
c8 ff 01 64 9a de ef 00 00:15:44.000 READ DMA
|
||||
c8 ff 01 63 9a de ef 00 00:15:44.000 READ DMA
|
||||
c8 ff 01 62 9a de ef 00 00:15:43.900 READ DMA
|
||||
|
||||
Error 2514 occurred at disk power-on lifetime: 3924 hours (163 days + 12 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
10 51 01 65 9a de ef Error: IDNF 1 sectors at LBA = 0x0fde9a65 = 266246757
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
c8 ff 01 65 9a de ef 00 00:15:44.000 READ DMA
|
||||
c8 ff 01 64 9a de ef 00 00:15:44.000 READ DMA
|
||||
c8 ff 01 63 9a de ef 00 00:15:44.000 READ DMA
|
||||
c8 ff 01 62 9a de ef 00 00:15:43.900 READ DMA
|
||||
c8 ff 01 61 9a de ef 00 00:15:43.900 READ DMA
|
||||
|
||||
Error 2513 occurred at disk power-on lifetime: 3924 hours (163 days + 12 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
10 51 01 64 9a de ef Error: IDNF 1 sectors at LBA = 0x0fde9a64 = 266246756
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
c8 ff 01 64 9a de ef 00 00:15:44.000 READ DMA
|
||||
c8 ff 01 63 9a de ef 00 00:15:44.000 READ DMA
|
||||
c8 ff 01 62 9a de ef 00 00:15:43.900 READ DMA
|
||||
c8 ff 01 61 9a de ef 00 00:15:43.900 READ DMA
|
||||
c8 ff 01 60 9a de ef 00 00:15:43.900 READ DMA
|
||||
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Aborted by host 90% 4163 -
|
||||
|
||||
Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
||||
163
HDD/Hitachi/HTS7250/HTS725050A7E630/3F2B86E01F8A
Normal file
163
HDD/Hitachi/HTS7250/HTS725050A7E630/3F2B86E01F8A
Normal file
@@ -0,0 +1,163 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z7K500
|
||||
Device Model: HTS725050A7E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GH2ZB390
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue May 26 23:57:48 2020 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 87) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 215 215 033 - 1
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 854
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 071 071 000 - 12855
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 852
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 1572890
|
||||
193 Load_Cycle_Count -O--C- 074 074 000 - 261437
|
||||
194 Temperature_Celsius -O---- 171 171 000 - 35 (Min/Max 14/48)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0x50) Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/35 Celsius
|
||||
Lifetime Min/Max Temperature: 14/48 Celsius
|
||||
Specified Max Operating Temperature: 32 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (64)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 13 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
249
HDD/Hitachi/HUA7210/HUA721010KLA330/93B47133802E
Normal file
249
HDD/Hitachi/HUA7210/HUA721010KLA330/93B47133802E
Normal file
@@ -0,0 +1,249 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Ultrastar A7K1000
|
||||
Device Model: HUA721010KLA330
|
||||
Serial Number: --
|
||||
Firmware Version: GKAOA94A
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
|
||||
Local Time is: Fri May 22 10:34:50 2020 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 128
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (15354) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 255) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 054 - 0
|
||||
3 Spin_Up_Time POS--- 106 106 024 - 667 (Average 647)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 367
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 132 132 020 - 33
|
||||
9 Power_On_Hours -O--C- 100 100 000 - 1249
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 367
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 367
|
||||
193 Load_Cycle_Count -O--C- 100 100 000 - 367
|
||||
194 Temperature_Celsius -O---- 133 133 000 - 45 (Min/Max 16/52)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 541
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x24 GPL R/O 60 Current Device Internal Status Data log
|
||||
0x80 GPL R/W 60 Host vendor specific log
|
||||
0x81-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
Device Error Count: 12 (device log contains only the most recent 4 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 12 [3] occurred at disk power-on lifetime: 12743 hours (530 days + 23 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 08 00 00 15 7c cc 77 45 00 Error: ICRC, ABRT at LBA = 0x157ccc77 = 360500343
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 68 00 80 00 00 15 7c cc 18 40 00 43d+16:41:39.848 READ FPDMA QUEUED
|
||||
60 00 08 00 80 00 00 15 80 cf 30 40 00 43d+16:41:39.848 READ FPDMA QUEUED
|
||||
60 00 08 00 80 00 00 15 7f 07 c8 40 00 43d+16:41:39.848 READ FPDMA QUEUED
|
||||
60 00 08 00 80 00 00 15 7f 07 c0 40 00 43d+16:41:39.848 READ FPDMA QUEUED
|
||||
60 00 08 00 80 00 00 15 7c 08 98 40 00 43d+16:41:39.848 READ FPDMA QUEUED
|
||||
|
||||
Error 11 [2] occurred at disk power-on lifetime: 12482 hours (520 days + 2 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 00 00 00 35 32 23 8f 45 00 Error: ICRC, ABRT at LBA = 0x3532238f = 892478351
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 80 00 00 35 32 23 88 40 00 32d+19:47:51.348 READ FPDMA QUEUED
|
||||
60 00 08 00 80 00 00 35 32 23 80 40 00 32d+19:47:51.348 READ FPDMA QUEUED
|
||||
60 00 08 00 80 00 00 35 30 08 90 40 00 32d+19:47:51.348 READ FPDMA QUEUED
|
||||
60 00 10 00 80 00 00 27 7a 42 90 40 00 32d+19:47:45.848 READ FPDMA QUEUED
|
||||
60 00 68 00 80 00 00 27 7a 42 28 40 00 32d+19:47:45.848 READ FPDMA QUEUED
|
||||
|
||||
Error 10 [1] occurred at disk power-on lifetime: 11803 hours (491 days + 19 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 03 10 00 00 63 65 32 8f 43 00 Error: ICRC, ABRT at LBA = 0x6365328f = 1667576463
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 04 00 00 80 00 00 63 65 31 a0 40 00 4d+12:28:21.148 READ FPDMA QUEUED
|
||||
60 00 10 00 80 00 00 6c 68 4f 58 40 00 4d+12:28:21.148 READ FPDMA QUEUED
|
||||
60 00 08 00 80 00 00 6c 68 c9 40 40 00 4d+12:28:21.148 READ FPDMA QUEUED
|
||||
60 00 08 00 80 00 00 6c 68 08 a8 40 00 4d+12:28:21.048 READ FPDMA QUEUED
|
||||
60 00 08 00 80 00 00 6c 69 ca f0 40 00 4d+12:28:21.048 READ FPDMA QUEUED
|
||||
|
||||
Error 9 [0] occurred at disk power-on lifetime: 11369 hours (473 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 58 00 00 26 9f 01 c7 46 00 Error: ICRC, ABRT at LBA = 0x269f01c7 = 647954887
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 88 00 00 48 50 08 50 40 00 36d+04:28:11.644 READ FPDMA QUEUED
|
||||
60 00 68 00 80 00 00 26 9f 01 b8 40 00 36d+04:28:11.644 READ FPDMA QUEUED
|
||||
60 00 08 00 80 00 00 49 bb a1 30 40 00 36d+04:28:11.644 READ FPDMA QUEUED
|
||||
60 00 08 00 80 00 00 49 b8 0a a0 40 00 36d+04:28:11.644 READ FPDMA QUEUED
|
||||
60 00 08 00 88 00 00 26 9c d4 40 40 00 36d+04:28:11.644 READ FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 0 -
|
||||
# 2 Extended offline Completed without error 00% 15110 -
|
||||
# 3 Extended offline Completed without error 00% 13646 -
|
||||
# 4 Extended offline Completed without error 00% 12182 -
|
||||
# 5 Extended offline Completed without error 00% 10722 -
|
||||
# 6 Extended offline Completed without error 00% 7310 -
|
||||
# 7 Extended offline Completed without error 00% 5846 -
|
||||
# 8 Extended offline Completed without error 00% 4381 -
|
||||
# 9 Extended offline Completed without error 00% 2917 -
|
||||
#10 Extended offline Completed without error 00% 1453 -
|
||||
#11 Extended offline Completed without error 00% 65525 -
|
||||
#12 Extended offline Completed without error 00% 64061 -
|
||||
#13 Extended offline Completed without error 00% 62597 -
|
||||
#14 Extended offline Completed without error 00% 61133 -
|
||||
#15 Extended offline Completed without error 00% 59668 -
|
||||
#16 Extended offline Completed without error 00% 58204 -
|
||||
#17 Extended offline Completed without error 00% 56741 -
|
||||
#18 Extended offline Completed without error 00% 55276 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: --/45 Celsius
|
||||
Lifetime Min/Max Temperature: --/52 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (37)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 250 (25.0 seconds)
|
||||
Write: 250 (25.0 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
200
HDD/Hitachi/HUA7220/HUA722020ALA330/6293AEC6C3FA
Normal file
200
HDD/Hitachi/HUA7220/HUA722020ALA330/6293AEC6C3FA
Normal file
@@ -0,0 +1,200 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Ultrastar A7K2000
|
||||
Device Model: HUA722020ALA330
|
||||
Serial Number: --
|
||||
Firmware Version: JKAOA3FB
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Mon May 25 17:02:19 2020 +07
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (22036) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 367) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
||||
2 Throughput_Performance P-S--- 132 132 054 - 103
|
||||
3 Spin_Up_Time POS--- 115 115 024 - 630 (Average 630)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 1638
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 123 123 020 - 34
|
||||
9 Power_On_Hours -O--C- 094 094 000 - 42180
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1588
|
||||
192 Power-Off_Retract_Count -O--CK 099 099 000 - 1646
|
||||
193 Load_Cycle_Count -O--C- 099 099 000 - 1646
|
||||
194 Temperature_Celsius -O---- 115 115 000 - 52 (Min/Max 13/79)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 7 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 63 Current Device Internal Status Data log
|
||||
0x80 GPL R/W 63 Host vendor specific log
|
||||
0x81-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 0 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 52 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/52 Celsius
|
||||
Lifetime Min/Max Temperature: 13/79 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/70 Celsius
|
||||
Temperature History Size (Index): 128 (19)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 150 (15.0 seconds)
|
||||
Write: 150 (15.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1588 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 42180 --- Power-on Hours
|
||||
0x01 0x018 6 209533711547 --- Logical Sectors Written
|
||||
0x01 0x020 6 2888891186 --- Number of Write Commands
|
||||
0x01 0x028 6 366206392379 --- Logical Sectors Read
|
||||
0x01 0x030 6 3183472727 --- Number of Read Commands
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 42164 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 42164 --- Head Flying Hours
|
||||
0x03 0x018 4 1646 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 377 --- Read Recovery Attempts
|
||||
0x03 0x030 4 4294967295 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 2018 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 51 --- Current Temperature
|
||||
0x05 0x010 1 50 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 50 N-- Average Long Term Temperature
|
||||
0x05 0x020 1 79 --- Highest Temperature
|
||||
0x05 0x028 1 13 --- Lowest Temperature
|
||||
0x05 0x030 1 70 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 0 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 65 N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 0 N-- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 74710 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 23870 --- Number of Hardware Resets
|
||||
0x06 0x010 4 3801 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
||||
200
HDD/Hitachi/HUA7220/HUA722020ALA330/8B348A8C0617
Normal file
200
HDD/Hitachi/HUA7220/HUA722020ALA330/8B348A8C0617
Normal file
@@ -0,0 +1,200 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Ultrastar A7K2000
|
||||
Device Model: HUA722020ALA330
|
||||
Serial Number: --
|
||||
Firmware Version: JKAOA3FB
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Mon May 25 17:02:17 2020 +07
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (22771) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 380) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
||||
2 Throughput_Performance P-S--- 132 132 054 - 104
|
||||
3 Spin_Up_Time POS--- 114 114 024 - 635 (Average 635)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 1622
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 121 121 020 - 35
|
||||
9 Power_On_Hours -O--C- 094 094 000 - 42012
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1572
|
||||
192 Power-Off_Retract_Count -O--CK 099 099 000 - 1631
|
||||
193 Load_Cycle_Count -O--C- 099 099 000 - 1631
|
||||
194 Temperature_Celsius -O---- 117 117 000 - 51 (Min/Max 14/89)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 7 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 63 Current Device Internal Status Data log
|
||||
0x80 GPL R/W 63 Host vendor specific log
|
||||
0x81-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 0 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 52 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/52 Celsius
|
||||
Lifetime Min/Max Temperature: 14/89 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/70 Celsius
|
||||
Temperature History Size (Index): 128 (75)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 150 (15.0 seconds)
|
||||
Write: 150 (15.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1572 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 42012 --- Power-on Hours
|
||||
0x01 0x018 6 203864784076 --- Logical Sectors Written
|
||||
0x01 0x020 6 2866819451 --- Number of Write Commands
|
||||
0x01 0x028 6 367829226204 --- Logical Sectors Read
|
||||
0x01 0x030 6 3158955457 --- Number of Read Commands
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 41997 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 41997 --- Head Flying Hours
|
||||
0x03 0x018 4 1631 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 731 --- Read Recovery Attempts
|
||||
0x03 0x030 4 4294967295 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 2171 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 51 --- Current Temperature
|
||||
0x05 0x010 1 50 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 50 N-- Average Long Term Temperature
|
||||
0x05 0x020 1 89 --- Highest Temperature
|
||||
0x05 0x028 1 14 --- Lowest Temperature
|
||||
0x05 0x030 1 80 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 0 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 75 N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 0 N-- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 90640 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 17874 --- Number of Hardware Resets
|
||||
0x06 0x010 4 3734 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
||||
280
HDD/Hitachi/HUA7220/HUA722020ALA330/D089BA327DB5
Normal file
280
HDD/Hitachi/HUA7220/HUA722020ALA330/D089BA327DB5
Normal file
@@ -0,0 +1,280 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Ultrastar A7K2000
|
||||
Device Model: HUA722020ALA330
|
||||
Serial Number: --
|
||||
Firmware Version: JKAOA3FB
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Mon May 25 17:02:21 2020 +07
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (22330) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 372) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 098 098 016 - 262145
|
||||
2 Throughput_Performance P-S--- 133 133 054 - 102
|
||||
3 Spin_Up_Time POS--- 115 115 024 - 630 (Average 630)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 3147
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 177
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 119 119 020 - 36
|
||||
9 Power_On_Hours -O--C- 094 094 000 - 42095
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 3097
|
||||
192 Power-Off_Retract_Count -O--CK 098 098 000 - 3162
|
||||
193 Load_Cycle_Count -O--C- 098 098 000 - 3162
|
||||
194 Temperature_Celsius -O---- 122 122 000 - 49 (Min/Max 13/88)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 181
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 7 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 63 Current Device Internal Status Data log
|
||||
0x80 GPL R/W 63 Host vendor specific log
|
||||
0x81-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
Device Error Count: 57 (device log contains only the most recent 4 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 57 [0] occurred at disk power-on lifetime: 30881 hours (1286 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 64 00 00 35 99 f0 9e 05 00 Error: UNC at LBA = 0x3599f09e = 899281054
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 80 00 78 00 00 35 99 f0 82 40 00 49d+01:00:40.847 READ FPDMA QUEUED
|
||||
60 00 80 00 70 00 00 98 96 8e d4 40 00 49d+01:00:30.857 READ FPDMA QUEUED
|
||||
60 00 80 00 68 00 00 98 c1 d8 18 40 00 49d+01:00:24.495 READ FPDMA QUEUED
|
||||
60 00 80 00 60 00 00 98 c1 f2 d4 40 00 49d+01:00:23.069 READ FPDMA QUEUED
|
||||
60 00 80 00 58 00 00 35 7c f0 bb 40 00 49d+01:00:22.525 READ FPDMA QUEUED
|
||||
|
||||
Error 56 [3] occurred at disk power-on lifetime: 29922 hours (1246 days + 18 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 36 00 00 30 c9 1e 6a 00 00 Error: UNC at LBA = 0x30c91e6a = 818486890
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 80 00 38 00 00 30 c9 1e 20 40 00 3d+21:40:32.419 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 3d+21:40:32.416 READ LOG EXT
|
||||
60 00 80 00 28 00 00 30 c9 1e 20 40 00 3d+21:40:15.787 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 3d+21:40:15.784 READ LOG EXT
|
||||
60 00 80 00 18 00 00 30 c9 1e 20 40 00 3d+21:39:54.120 READ FPDMA QUEUED
|
||||
|
||||
Error 55 [2] occurred at disk power-on lifetime: 29922 hours (1246 days + 18 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 36 00 00 30 c9 1e 6a 00 00 Error: UNC at LBA = 0x30c91e6a = 818486890
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 80 00 28 00 00 30 c9 1e 20 40 00 3d+21:40:15.787 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 3d+21:40:15.784 READ LOG EXT
|
||||
60 00 80 00 18 00 00 30 c9 1e 20 40 00 3d+21:39:54.120 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 3d+21:39:54.117 READ LOG EXT
|
||||
60 00 80 00 08 00 00 30 c9 1e 20 40 00 3d+21:39:37.539 READ FPDMA QUEUED
|
||||
|
||||
Error 54 [1] occurred at disk power-on lifetime: 29922 hours (1246 days + 18 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 36 00 00 30 c9 1e 6a 00 00 Error: UNC at LBA = 0x30c91e6a = 818486890
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 80 00 18 00 00 30 c9 1e 20 40 00 3d+21:39:54.120 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 3d+21:39:54.117 READ LOG EXT
|
||||
60 00 80 00 08 00 00 30 c9 1e 20 40 00 3d+21:39:37.539 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 3d+21:39:37.537 READ LOG EXT
|
||||
60 00 80 00 f8 00 00 30 c9 1e 20 40 00 3d+21:39:19.888 READ FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 49 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/49 Celsius
|
||||
Lifetime Min/Max Temperature: 13/88 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/70 Celsius
|
||||
Temperature History Size (Index): 128 (15)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 150 (15.0 seconds)
|
||||
Write: 150 (15.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 3097 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 42095 --- Power-on Hours
|
||||
0x01 0x018 6 207922567676 --- Logical Sectors Written
|
||||
0x01 0x020 6 2867471473 --- Number of Write Commands
|
||||
0x01 0x028 6 392277792716 --- Logical Sectors Read
|
||||
0x01 0x030 6 3133628817 --- Number of Read Commands
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 42077 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 42077 --- Head Flying Hours
|
||||
0x03 0x018 4 3162 --- Head Load Events
|
||||
0x03 0x020 4 177 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 8743 --- Read Recovery Attempts
|
||||
0x03 0x030 4 4294967295 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 57 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 2114 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 48 --- Current Temperature
|
||||
0x05 0x010 1 47 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 47 N-- Average Long Term Temperature
|
||||
0x05 0x020 1 88 --- Highest Temperature
|
||||
0x05 0x028 1 13 --- Lowest Temperature
|
||||
0x05 0x030 1 83 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 0 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 83 N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 0 N-- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 86050 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 37339 --- Number of Hardware Resets
|
||||
0x06 0x010 4 3801 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
225
HDD/Hitachi/HUA7230/HUA723020ALA641/5B7005B0FA95
Normal file
225
HDD/Hitachi/HUA7230/HUA723020ALA641/5B7005B0FA95
Normal file
@@ -0,0 +1,225 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Ultrastar 7K3000
|
||||
Device Model: HUA723020ALA641
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: MK7OA840
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 11:21:40 2020 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (18286) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 305) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
||||
2 Throughput_Performance P-S--- 135 135 054 - 85
|
||||
3 Spin_Up_Time POS--- 178 178 024 - 351 (Average 348)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 92
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 123 123 020 - 31
|
||||
9 Power_On_Hours -O--C- 091 091 000 - 65151
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 91
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 479
|
||||
193 Load_Cycle_Count -O--C- 100 100 000 - 479
|
||||
194 Temperature_Celsius -O---- 157 157 000 - 38 (Min/Max 20/40)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 7 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 63 Current Device Internal Status Data log
|
||||
0x80 GPL R/W 63 Host vendor specific log
|
||||
0x81-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 65019 -
|
||||
# 2 Short offline Completed without error 00% 65018 -
|
||||
# 3 Short offline Completed without error 00% 65017 -
|
||||
# 4 Short offline Completed without error 00% 65016 -
|
||||
# 5 Short offline Completed without error 00% 65015 -
|
||||
# 6 Short offline Completed without error 00% 65014 -
|
||||
# 7 Short offline Completed without error 00% 65013 -
|
||||
# 8 Short offline Completed without error 00% 65012 -
|
||||
# 9 Short offline Completed without error 00% 65011 -
|
||||
#10 Short offline Completed without error 00% 65010 -
|
||||
#11 Short offline Completed without error 00% 65009 -
|
||||
#12 Short offline Completed without error 00% 65008 -
|
||||
#13 Short offline Completed without error 00% 65007 -
|
||||
#14 Short offline Completed without error 00% 65006 -
|
||||
#15 Short offline Completed without error 00% 65005 -
|
||||
#16 Short offline Completed without error 00% 65004 -
|
||||
#17 Short offline Completed without error 00% 65003 -
|
||||
#18 Short offline Completed without error 00% 65002 -
|
||||
#19 Short offline Completed without error 00% 65001 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/39 Celsius
|
||||
Lifetime Min/Max Temperature: 20/40 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/70 Celsius
|
||||
Temperature History Size (Index): 128 (32)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 91 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 65151 --- Power-on Hours
|
||||
0x01 0x018 6 1011831956241 --- Logical Sectors Written
|
||||
0x01 0x020 6 5317211136 --- Number of Write Commands
|
||||
0x01 0x028 6 840208032666 --- Logical Sectors Read
|
||||
0x01 0x030 6 3003455446 --- Number of Read Commands
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 65140 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 65140 --- Head Flying Hours
|
||||
0x03 0x018 4 479 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 140 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 38 --- Current Temperature
|
||||
0x05 0x010 1 37 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 36 N-- Average Long Term Temperature
|
||||
0x05 0x020 1 40 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 38 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 24 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 37 N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 1544 --- Number of Hardware Resets
|
||||
0x06 0x010 4 1459 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
||||
225
HDD/Hitachi/HUA7230/HUA723020ALA641/79BE99B5B32C
Normal file
225
HDD/Hitachi/HUA7230/HUA723020ALA641/79BE99B5B32C
Normal file
@@ -0,0 +1,225 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi Ultrastar 7K3000
|
||||
Device Model: HUA723020ALA641
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: MK7OA840
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 11:21:42 2020 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (19618) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 327) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
||||
2 Throughput_Performance P-S--- 133 133 054 - 92
|
||||
3 Spin_Up_Time POS--- 181 181 024 - 346 (Average 343)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 92
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 123 123 020 - 31
|
||||
9 Power_On_Hours -O--C- 093 093 000 - 53385
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 92
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 459
|
||||
193 Load_Cycle_Count -O--C- 100 100 000 - 459
|
||||
194 Temperature_Celsius -O---- 171 171 000 - 35 (Min/Max 20/47)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 7 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 63 Current Device Internal Status Data log
|
||||
0x80 GPL R/W 63 Host vendor specific log
|
||||
0x81-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 53253 -
|
||||
# 2 Short offline Completed without error 00% 53251 -
|
||||
# 3 Short offline Completed without error 00% 53250 -
|
||||
# 4 Short offline Completed without error 00% 53249 -
|
||||
# 5 Short offline Completed without error 00% 53248 -
|
||||
# 6 Short offline Completed without error 00% 53247 -
|
||||
# 7 Short offline Completed without error 00% 53246 -
|
||||
# 8 Short offline Completed without error 00% 53245 -
|
||||
# 9 Short offline Completed without error 00% 53244 -
|
||||
#10 Short offline Completed without error 00% 53243 -
|
||||
#11 Short offline Completed without error 00% 53242 -
|
||||
#12 Short offline Completed without error 00% 53241 -
|
||||
#13 Short offline Completed without error 00% 53241 -
|
||||
#14 Short offline Completed without error 00% 53239 -
|
||||
#15 Short offline Completed without error 00% 53238 -
|
||||
#16 Short offline Completed without error 00% 53237 -
|
||||
#17 Short offline Completed without error 00% 53236 -
|
||||
#18 Short offline Completed without error 00% 53235 -
|
||||
#19 Short offline Completed without error 00% 53234 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/36 Celsius
|
||||
Lifetime Min/Max Temperature: 20/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/70 Celsius
|
||||
Temperature History Size (Index): 128 (41)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 92 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 53385 --- Power-on Hours
|
||||
0x01 0x018 6 800849997789 --- Logical Sectors Written
|
||||
0x01 0x020 6 2276370548 --- Number of Write Commands
|
||||
0x01 0x028 6 1004162559221 --- Logical Sectors Read
|
||||
0x01 0x030 6 2428286949 --- Number of Read Commands
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 53375 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 53375 --- Head Flying Hours
|
||||
0x03 0x018 4 459 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 172 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 35 --- Current Temperature
|
||||
0x05 0x010 1 34 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 33 N-- Average Long Term Temperature
|
||||
0x05 0x020 1 47 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 43 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 21 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 40 N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 735 --- Number of Hardware Resets
|
||||
0x06 0x010 4 535 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
||||
208
HDD/Hitachi/HUA7230/HUA723030ALA640/B570BB030A4D
Normal file
208
HDD/Hitachi/HUA7230/HUA723030ALA640/B570BB030A4D
Normal file
@@ -0,0 +1,208 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: HUA723030ALA640
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: MKAONS01
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 11:21:36 2020 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (28319) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 472) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 054 - 0
|
||||
3 Spin_Up_Time POS--- 189 189 024 - 381 (Average 439)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 21
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 020 - 0
|
||||
9 Power_On_Hours -O--C- 099 099 000 - 13522
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 21
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 479
|
||||
193 Load_Cycle_Count -O--C- 100 100 000 - 479
|
||||
194 Temperature_Celsius -O---- 162 162 000 - 37 (Min/Max 24/38)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 7 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 63 Current Device Internal Status Data log
|
||||
0x80 GPL R/W 63 Host vendor specific log
|
||||
0x81-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa2 GPL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 49769 -
|
||||
# 2 Short offline Completed without error 00% 49761 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/38 Celsius
|
||||
Lifetime Min/Max Temperature: 24/38 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/70 Celsius
|
||||
Temperature History Size (Index): 128 (126)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 21 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 13522 --- Power-on Hours
|
||||
0x01 0x018 6 15657208876 --- Logical Sectors Written
|
||||
0x01 0x020 6 362663136 --- Number of Write Commands
|
||||
0x01 0x028 6 27986681356 --- Logical Sectors Read
|
||||
0x01 0x030 6 118607334 --- Number of Read Commands
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 13520 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 13520 --- Head Flying Hours
|
||||
0x03 0x018 4 479 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 36 --- Current Temperature
|
||||
0x05 0x010 1 35 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 34 N-- Average Long Term Temperature
|
||||
0x05 0x020 1 38 --- Highest Temperature
|
||||
0x05 0x028 1 24 --- Lowest Temperature
|
||||
0x05 0x030 1 36 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 25 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 35 N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 151 --- Number of Hardware Resets
|
||||
0x06 0x010 4 129 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
||||
64
HDD/Hitachi/README.md
Normal file
64
HDD/Hitachi/README.md
Normal file
@@ -0,0 +1,64 @@
|
||||
Hitachi Hard Drives
|
||||
===================
|
||||
|
||||
This is a list of all tested Hitachi hard drive models and their MTBFs. See more
|
||||
info on reliability test in the [README](https://github.com/bsdhw/SMART).
|
||||
|
||||
Contents
|
||||
--------
|
||||
|
||||
1. [ HDD by Model ](#hdd-by-model)
|
||||
2. [ HDD by Family ](#hdd-by-family)
|
||||
|
||||
HDD by Model
|
||||
------------
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Model | Size | Samples | Days | Err | MTBF |
|
||||
|-----------|--------------------|--------|---------|-------|-------|--------|
|
||||
| Hitachi | HDS725050KLA360 | 500 GB | 1 | 3763 | 0 | 10.31 |
|
||||
| Hitachi | HDT725025VLA380 | 250 GB | 1 | 2680 | 0 | 7.34 |
|
||||
| Hitachi | HUA723020ALA641 | 2 TB | 2 | 2469 | 0 | 6.77 |
|
||||
| Hitachi | HDS721616PLAT80 | 160 GB | 1 | 2187 | 0 | 5.99 |
|
||||
| Hitachi | HUA722020ALA330 | 2 TB | 3 | 1753 | 121 | 3.21 |
|
||||
| Hitachi | HUA723030ALA640 | 3 TB | 1 | 563 | 0 | 1.54 |
|
||||
| Hitachi | HTS725050A7E630 | 500 GB | 1 | 535 | 0 | 1.47 |
|
||||
| Hitachi | HTS541660J9SA00 | 64 GB | 1 | 517 | 0 | 1.42 |
|
||||
| Hitachi | HTS421260H9AT00 | 64 GB | 1 | 1338 | 12 | 0.28 |
|
||||
| Hitachi | HUA721010KLA330 | 1 TB | 1 | 52 | 0 | 0.14 |
|
||||
| Hitachi | HTS543212L9A300 | 120 GB | 1 | 1158 | 88 | 0.04 |
|
||||
| Hitachi | HDS721010CLA332 | 1 TB | 1 | 1511 | 220 | 0.02 |
|
||||
| Hitachi | HTS721060G9AT00 | 64 GB | 1 | 0 | 37 | 0.00 |
|
||||
|
||||
HDD by Family
|
||||
-------------
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Family | Models | Samples | Days | Err | MTBF |
|
||||
|-----------|------------------------|--------|---------|-------|-------|--------|
|
||||
| Hitachi | Deskstar 7K500 | 1 | 1 | 3763 | 0 | 10.31 |
|
||||
| Hitachi | Deskstar T7K500 | 1 | 1 | 2680 | 0 | 7.34 |
|
||||
| Hitachi | Deskstar 7K160 | 1 | 1 | 2187 | 0 | 5.99 |
|
||||
| Hitachi | Ultrastar 7K3000 | 2 | 3 | 1834 | 0 | 5.03 |
|
||||
| Hitachi | Ultrastar A7K2000 | 1 | 3 | 1753 | 121 | 3.21 |
|
||||
| Hitachi | Travelstar Z7K500 | 1 | 1 | 535 | 0 | 1.47 |
|
||||
| Hitachi | Travelstar 5K160 | 1 | 1 | 517 | 0 | 1.42 |
|
||||
| Hitachi | Travelstar 4K120 | 1 | 1 | 1338 | 12 | 0.28 |
|
||||
| Hitachi | Ultrastar A7K1000 | 1 | 1 | 52 | 0 | 0.14 |
|
||||
| Hitachi | Travelstar 5K320 | 1 | 1 | 1158 | 88 | 0.04 |
|
||||
| Hitachi | Deskstar 7K1000.C | 1 | 1 | 1511 | 220 | 0.02 |
|
||||
| Hitachi | Travelstar 7K100 | 1 | 1 | 0 | 37 | 0.00 |
|
||||
205
HDD/Samsung/HD501/HD501LJ/1BD671150948
Normal file
205
HDD/Samsung/HD501/HD501LJ/1BD671150948
Normal file
@@ -0,0 +1,205 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint T166
|
||||
Device Model: SAMSUNG HD501LJ
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0000f0 ...
|
||||
Firmware Version: CR100-12
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 3b
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Mon May 25 14:02:02 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 254
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 9032) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 154) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 4
|
||||
3 Spin_Up_Time POS--- 100 100 015 - 7360
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4156
|
||||
5 Reallocated_Sector_Ct PO--CK 253 253 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 253 253 051 - 0
|
||||
8 Seek_Time_Performance P-S--K 253 253 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 96344
|
||||
10 Spin_Retry_Count PO--CK 253 253 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 253 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 4141
|
||||
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 392426628
|
||||
187 Reported_Uncorrect -O--CK 253 253 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 1
|
||||
190 Airflow_Temperature_Cel -O---K 061 050 000 - 39
|
||||
194 Temperature_Celsius -O---K 121 088 000 - 39
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 392426628
|
||||
196 Reallocated_Event_Count -O--CK 253 253 000 - 0
|
||||
197 Total_Pending_Sectors -O--C- 253 253 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 253 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
|
||||
201 Soft_Read_Error_Rate -O-R-- 100 100 000 - 0
|
||||
202 Data_Address_Mark_Errs -O--CK 253 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
Invalid Error Log index = 0x0000, trying reserved byte (0x01) instead
|
||||
Device Error Count: 1
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 12562 hours (523 days + 10 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 80 00 00 00 21 c4 bf e0 00 Error: ABRT 128 sectors at LBA = 0x0021c4bf = 2213055
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
35 00 00 00 80 00 00 00 21 c4 bf e0 00 00:01:58.375 WRITE DMA EXT
|
||||
25 00 00 00 80 00 00 00 21 c5 bf e0 00 00:01:58.375 READ DMA EXT
|
||||
25 00 00 00 80 00 00 00 21 c5 3f e0 00 00:01:58.375 READ DMA EXT
|
||||
25 00 00 00 80 00 00 00 21 c4 bf e0 00 00:01:58.375 READ DMA EXT
|
||||
25 00 00 00 80 00 00 00 21 c4 3f e0 00 00:01:58.375 READ DMA EXT
|
||||
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/48 Celsius
|
||||
Lifetime Min/Max Temperature: 11/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: -4/72 Celsius
|
||||
Min/Max Temperature Limit: -9/77 Celsius
|
||||
Temperature History Size (Index): 128 (27)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 63 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x8001 2 0 Vendor specific
|
||||
|
||||
|
||||
|
||||
305
HDD/Samsung/HD501/HD501LJ/D37BC44F1A91
Normal file
305
HDD/Samsung/HD501/HD501LJ/D37BC44F1A91
Normal file
@@ -0,0 +1,305 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint T166
|
||||
Device Model: SAMSUNG HD501LJ
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0000f0 ...
|
||||
Firmware Version: CR100-12
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 3b
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Mon May 25 14:01:48 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 254
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 9041) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 154) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0
|
||||
3 Spin_Up_Time POS--- 100 100 015 - 7232
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 372
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 2
|
||||
7 Seek_Error_Rate POSR-- 253 253 051 - 0
|
||||
8 Seek_Time_Performance P-S--K 253 253 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 88771
|
||||
10 Spin_Retry_Count PO--CK 253 253 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 253 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 351
|
||||
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 188191809
|
||||
187 Reported_Uncorrect -O--CK 253 253 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 8
|
||||
190 Airflow_Temperature_Cel -O---K 070 053 000 - 30
|
||||
194 Temperature_Celsius -O---K 148 097 000 - 30
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 188191809
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 2
|
||||
197 Total_Pending_Sectors -O--C- 253 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 253 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
|
||||
201 Soft_Read_Error_Rate -O-R-- 100 100 000 - 0
|
||||
202 Data_Address_Mark_Errs -O--CK 253 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
Invalid Error Log index = 0x0000, trying reserved byte (0x02) instead
|
||||
Device Error Count: 42 (device log contains only the most recent 8 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 42 [1] occurred at disk power-on lifetime: 28745 hours (1197 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 07 40 00 00 0a 62 74 54 40 00 Error: WP at LBA = 0x0a627454 = 174224468
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 80 02 07 40 00 00 0a 62 74 54 40 00 29d+04:17:16.379 WRITE FPDMA QUEUED
|
||||
2f 80 00 00 01 00 00 00 00 00 10 40 00 29d+04:17:10.566 READ LOG EXT
|
||||
|
||||
Error 41 [0] occurred at disk power-on lifetime: 28745 hours (1197 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 03 20 00 00 0a 62 74 54 40 00 Error: WP at LBA = 0x0a627454 = 174224468
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 80 02 03 20 00 00 0a 62 74 54 40 00 29d+04:17:10.441 WRITE FPDMA QUEUED
|
||||
2f 80 00 00 01 00 00 00 00 00 10 40 00 29d+04:17:04.629 READ LOG EXT
|
||||
|
||||
Error 40 [7] occurred at disk power-on lifetime: 28745 hours (1197 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 1f 00 00 00 0a 62 74 54 40 00 Error: WP at LBA = 0x0a627454 = 174224468
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 80 02 1f 00 00 00 0a 62 74 54 40 00 29d+04:17:04.566 WRITE FPDMA QUEUED
|
||||
2f 80 00 00 01 00 00 00 00 00 10 40 00 29d+04:16:58.379 READ LOG EXT
|
||||
|
||||
Error 39 [6] occurred at disk power-on lifetime: 28745 hours (1197 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 1b e0 00 00 0a 62 74 54 40 00 Error: WP at LBA = 0x0a627454 = 174224468
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 80 02 1b e0 00 00 0a 62 74 54 40 00 29d+04:16:58.316 WRITE FPDMA QUEUED
|
||||
2f 80 00 00 01 00 00 00 00 00 10 40 00 29d+04:16:53.129 READ LOG EXT
|
||||
|
||||
Error 38 [5] occurred at disk power-on lifetime: 28745 hours (1197 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 14 a0 00 00 01 6a 42 80 40 00 Error: UNC at LBA = 0x016a4280 = 23741056
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 80 80 14 a0 00 00 01 6a 42 80 40 00 29d+04:16:53.004 READ FPDMA QUEUED
|
||||
60 80 80 14 a0 00 00 01 6a 42 00 40 00 29d+04:16:46.879 READ FPDMA QUEUED
|
||||
60 80 80 14 a0 00 00 01 6a 41 80 40 00 29d+04:16:46.879 READ FPDMA QUEUED
|
||||
60 80 80 14 a0 00 00 01 6a 41 00 40 00 29d+04:16:46.879 READ FPDMA QUEUED
|
||||
60 80 80 14 a0 00 00 01 6a 40 80 40 00 29d+04:16:46.879 READ FPDMA QUEUED
|
||||
|
||||
Error 37 [4] occurred at disk power-on lifetime: 28739 hours (1197 days + 11 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 16 b8 00 00 0a ba 55 38 40 00 Error: WP at LBA = 0x0aba5538 = 179983672
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 02 16 b8 00 00 0a ba 55 38 40 00 28d+22:22:42.129 WRITE FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 00 28d+22:22:36.629 READ LOG EXT
|
||||
|
||||
Error 36 [3] occurred at disk power-on lifetime: 28739 hours (1197 days + 11 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 12 98 00 00 0a ba 55 38 40 00 Error: WP at LBA = 0x0aba5538 = 179983672
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 02 12 98 00 00 0a ba 55 38 40 00 28d+22:22:36.566 WRITE FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 00 28d+22:22:29.754 READ LOG EXT
|
||||
|
||||
Error 35 [2] occurred at disk power-on lifetime: 28739 hours (1197 days + 11 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 0e 78 00 00 0a ba 55 38 40 00 Error: WP at LBA = 0x0aba5538 = 179983672
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 02 0e 78 00 00 0a ba 55 38 40 00 28d+22:22:29.629 WRITE FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 00 28d+22:22:23.816 READ LOG EXT
|
||||
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 17716 -
|
||||
# 2 Extended offline Completed without error 00% 6938 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/35 Celsius
|
||||
Lifetime Min/Max Temperature: 12/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: -4/72 Celsius
|
||||
Min/Max Temperature Limit: -9/77 Celsius
|
||||
Temperature History Size (Index): 128 (58)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 66 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x8001 2 0 Vendor specific
|
||||
|
||||
|
||||
|
||||
301
HDD/Samsung/HD501/HD501LJ/DA9C7BFC6782
Normal file
301
HDD/Samsung/HD501/HD501LJ/DA9C7BFC6782
Normal file
@@ -0,0 +1,301 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint T166
|
||||
Device Model: SAMSUNG HD501LJ
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0000f0 ...
|
||||
Firmware Version: CR100-12
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 3b
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Mon May 25 14:02:03 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 254
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 9032) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 154) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 76
|
||||
3 Spin_Up_Time POS--- 100 100 015 - 7296
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4223
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 1
|
||||
7 Seek_Error_Rate POSR-- 253 253 051 - 0
|
||||
8 Seek_Time_Performance P-S--K 253 253 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 96326
|
||||
10 Spin_Retry_Count PO--CK 253 253 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 253 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 4209
|
||||
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 585510691
|
||||
187 Reported_Uncorrect -O--CK 253 253 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 4
|
||||
190 Airflow_Temperature_Cel -O---K 063 045 000 - 37
|
||||
194 Temperature_Celsius -O---K 127 073 000 - 37
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 585510691
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 1
|
||||
197 Total_Pending_Sectors -O--C- 253 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 253 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
|
||||
201 Soft_Read_Error_Rate -O-R-- 100 100 000 - 0
|
||||
202 Data_Address_Mark_Errs -O--CK 253 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
Invalid Error Log index = 0x0000, trying reserved byte (0x03) instead
|
||||
Device Error Count: 11 (device log contains only the most recent 8 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 11 [2] occurred at disk power-on lifetime: 22162 hours (923 days + 10 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 1b e0 00 00 00 00 04 2a 40 00 Error: UNC at LBA = 0x0000042a = 1066
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 c0 08 1b e0 00 00 00 00 04 2a 40 00 10d+14:40:24.695 READ FPDMA QUEUED
|
||||
2f c0 00 00 01 00 00 00 00 00 10 40 00 10d+14:40:17.820 READ LOG EXT
|
||||
|
||||
Error 10 [1] occurred at disk power-on lifetime: 22162 hours (923 days + 10 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
01 -- 51 18 c8 00 00 00 00 04 2a 40 00 Error: AMNF at LBA = 0x0000042a = 1066
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 c0 08 18 c8 00 00 00 00 04 2a 40 00 10d+14:40:17.695 READ FPDMA QUEUED
|
||||
2f 07 00 00 01 00 00 00 00 00 10 40 00 10d+14:40:09.695 READ LOG EXT
|
||||
|
||||
Error 9 [0] occurred at disk power-on lifetime: 22162 hours (923 days + 10 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 15 b0 00 00 27 52 2b bf 40 00 Error: WP at LBA = 0x27522bbf = 659696575
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 07 08 15 b0 00 00 27 52 2b bf 40 00 10d+14:40:09.570 WRITE FPDMA QUEUED
|
||||
61 07 08 15 b0 00 00 27 52 2b bf 40 00 10d+14:40:04.007 WRITE FPDMA QUEUED
|
||||
61 07 08 15 b0 00 00 27 52 2b bf 40 00 10d+14:40:04.007 WRITE FPDMA QUEUED
|
||||
61 07 08 15 b0 00 00 27 52 2b bf 40 00 10d+14:40:04.007 WRITE FPDMA QUEUED
|
||||
61 07 08 15 b0 00 00 27 52 2b bf 40 00 10d+14:40:04.007 WRITE FPDMA QUEUED
|
||||
|
||||
Error 8 [7] occurred at disk power-on lifetime: 22162 hours (923 days + 10 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 0e 78 00 00 27 52 2b bf 40 00 Error: WP at LBA = 0x27522bbf = 659696575
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 08 08 0e 78 00 00 27 52 2b bf 40 00 10d+14:40:03.820 WRITE FPDMA QUEUED
|
||||
2f 08 00 00 01 00 00 00 00 00 10 40 00 10d+14:39:56.132 READ LOG EXT
|
||||
|
||||
Error 7 [6] occurred at disk power-on lifetime: 22162 hours (923 days + 10 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 06 38 00 00 27 52 2b bf 40 00 Error: WP at LBA = 0x27522bbf = 659696575
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 08 08 06 38 00 00 27 52 2b bf 40 00 10d+14:39:56.007 WRITE FPDMA QUEUED
|
||||
2f 08 00 00 01 00 00 00 00 00 10 40 00 10d+14:39:48.757 READ LOG EXT
|
||||
|
||||
Error 6 [5] occurred at disk power-on lifetime: 22162 hours (923 days + 10 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 1e f8 00 00 27 52 2b bf 40 00 Error: WP at LBA = 0x27522bbf = 659696575
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 08 08 1e f8 00 00 27 52 2b bf 40 00 10d+14:39:48.632 WRITE FPDMA QUEUED
|
||||
2f 08 00 00 01 00 00 00 00 00 10 40 00 10d+14:39:42.382 READ LOG EXT
|
||||
|
||||
Error 5 [4] occurred at disk power-on lifetime: 22162 hours (923 days + 10 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 16 b8 00 00 27 52 2b bf 40 00 Error: WP at LBA = 0x27522bbf = 659696575
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 08 08 16 b8 00 00 27 52 2b bf 40 00 10d+14:39:42.257 WRITE FPDMA QUEUED
|
||||
2f 08 00 00 01 00 00 00 00 00 10 40 00 10d+14:39:35.320 READ LOG EXT
|
||||
|
||||
Error 4 [3] occurred at disk power-on lifetime: 22162 hours (923 days + 10 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 0e 78 00 00 27 52 2b bf 40 00 Error: WP at LBA = 0x27522bbf = 659696575
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 08 08 0e 78 00 00 27 52 2b bf 40 00 10d+14:39:35.257 WRITE FPDMA QUEUED
|
||||
2f c0 00 00 01 00 00 00 00 00 10 40 00 10d+14:39:27.257 READ LOG EXT
|
||||
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/45 Celsius
|
||||
Lifetime Min/Max Temperature: 12/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: -4/72 Celsius
|
||||
Min/Max Temperature Limit: -9/77 Celsius
|
||||
Temperature History Size (Index): 128 (29)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 15 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 63 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x8001 2 0 Vendor specific
|
||||
|
||||
309
HDD/Samsung/HD501/HD501LJ/EF58C0E9ABE3
Normal file
309
HDD/Samsung/HD501/HD501LJ/EF58C0E9ABE3
Normal file
@@ -0,0 +1,309 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint T166
|
||||
Device Model: SAMSUNG HD501LJ
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0000f0 ...
|
||||
Firmware Version: CR100-12
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 3b
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Mon May 25 14:01:49 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 254
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 9033) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 154) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 1
|
||||
3 Spin_Up_Time POS--- 100 100 015 - 7360
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 787
|
||||
5 Reallocated_Sector_Ct PO--CK 253 253 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 253 253 051 - 0
|
||||
8 Seek_Time_Performance P-S--K 253 253 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 90221
|
||||
10 Spin_Retry_Count PO--CK 253 253 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 253 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 586
|
||||
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 253323093
|
||||
187 Reported_Uncorrect -O--CK 253 253 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 2
|
||||
190 Airflow_Temperature_Cel -O---K 067 051 000 - 33
|
||||
194 Temperature_Celsius -O---K 139 091 000 - 33
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 253323093
|
||||
196 Reallocated_Event_Count -O--CK 253 253 000 - 0
|
||||
197 Total_Pending_Sectors -O--C- 253 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 253 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
|
||||
201 Soft_Read_Error_Rate -O-R-- 100 100 000 - 0
|
||||
202 Data_Address_Mark_Errs -O--CK 253 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
Invalid Error Log index = 0x0000, trying reserved byte (0x08) instead
|
||||
Device Error Count: 56 (device log contains only the most recent 8 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 56 [7] occurred at disk power-on lifetime: 30381 hours (1265 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 0a 58 00 00 27 ea ed 19 40 00 Error: WP at LBA = 0x27eaed19 = 669707545
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 01 02 0a 58 00 00 27 ea ed 19 40 00 1d+06:25:56.688 WRITE FPDMA QUEUED
|
||||
2f 01 00 00 01 00 00 00 00 00 10 40 00 1d+06:25:51.813 READ LOG EXT
|
||||
|
||||
Error 55 [6] occurred at disk power-on lifetime: 30381 hours (1265 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 06 38 00 00 27 ea ed 19 40 00 Error: WP at LBA = 0x27eaed19 = 669707545
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 01 02 06 38 00 00 27 ea ed 19 40 00 1d+06:25:51.688 WRITE FPDMA QUEUED
|
||||
2f 01 00 00 01 00 00 00 00 00 10 40 00 1d+06:25:46.563 READ LOG EXT
|
||||
|
||||
Error 54 [5] occurred at disk power-on lifetime: 30381 hours (1265 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 02 18 00 00 27 ea ed 19 40 00 Error: WP at LBA = 0x27eaed19 = 669707545
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 01 02 02 18 00 00 27 ea ed 19 40 00 1d+06:25:46.438 WRITE FPDMA QUEUED
|
||||
2f 01 00 00 01 00 00 00 00 00 10 40 00 1d+06:25:40.563 READ LOG EXT
|
||||
|
||||
Error 53 [4] occurred at disk power-on lifetime: 30381 hours (1265 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 1e f8 00 00 27 ea ed 19 40 00 Error: WP at LBA = 0x27eaed19 = 669707545
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 01 02 1e f8 00 00 27 ea ed 19 40 00 1d+06:25:40.438 WRITE FPDMA QUEUED
|
||||
2f 01 00 00 01 00 00 00 00 00 10 40 00 1d+06:25:34.313 READ LOG EXT
|
||||
|
||||
Error 52 [3] occurred at disk power-on lifetime: 30381 hours (1265 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 17 b8 00 00 33 d1 6f b9 40 00 Error: UNC at LBA = 0x33d16fb9 = 869363641
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 01 17 b8 00 00 33 d1 6f b9 40 00 1d+06:25:34.188 READ FPDMA QUEUED
|
||||
ea 02 00 00 00 00 00 00 00 00 00 40 00 1d+06:25:29.438 FLUSH CACHE EXT
|
||||
61 02 02 16 b8 00 00 3a 38 5e c6 40 00 1d+06:25:29.438 WRITE FPDMA QUEUED
|
||||
61 02 02 16 b8 00 00 3a 38 5e c6 40 00 1d+06:25:29.438 WRITE FPDMA QUEUED
|
||||
61 02 02 15 b0 00 00 3a 38 5c c6 40 00 1d+06:25:29.438 WRITE FPDMA QUEUED
|
||||
|
||||
Error 51 [2] occurred at disk power-on lifetime: 30381 hours (1265 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 16 b8 00 00 0a 81 07 80 40 00 Error: WP at LBA = 0x0a810780 = 176228224
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 01 08 16 b8 00 00 0a 81 07 80 40 00 1d+06:24:38.875 WRITE FPDMA QUEUED
|
||||
ec d5 00 00 01 00 00 00 00 00 00 40 00 1d+06:24:33.125 IDENTIFY DEVICE
|
||||
b0 00 d5 00 01 00 00 00 c2 4f 01 40 00 1d+06:24:33.000 SMART READ LOG
|
||||
2f 01 00 00 01 00 00 00 00 00 10 40 00 1d+06:24:33.000 READ LOG EXT
|
||||
|
||||
Error 50 [1] occurred at disk power-on lifetime: 30381 hours (1265 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 15 b0 00 00 0a 81 07 80 40 00 Error: WP at LBA = 0x0a810780 = 176228224
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 01 08 15 b0 00 00 0a 81 07 80 40 00 1d+06:24:32.875 WRITE FPDMA QUEUED
|
||||
b0 00 d5 00 01 00 00 00 c2 4f 06 40 00 1d+06:24:28.063 SMART READ LOG
|
||||
2f 01 00 00 01 00 00 00 00 00 10 40 00 1d+06:24:28.000 READ LOG EXT
|
||||
|
||||
Error 49 [0] occurred at disk power-on lifetime: 30381 hours (1265 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 14 a8 00 00 0a 81 07 80 40 00 Error: WP at LBA = 0x0a810780 = 176228224
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 01 08 14 a8 00 00 0a 81 07 80 40 00 1d+06:24:27.875 WRITE FPDMA QUEUED
|
||||
b0 00 d0 00 01 00 00 00 c2 4f 00 40 00 1d+06:24:20.688 SMART READ DATA
|
||||
2f 01 00 00 01 00 00 00 00 00 10 40 00 1d+06:24:20.625 READ LOG EXT
|
||||
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 19174 -
|
||||
# 2 Extended offline Completed without error 00% 8405 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/38 Celsius
|
||||
Lifetime Min/Max Temperature: 12/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: -4/72 Celsius
|
||||
Min/Max Temperature Limit: -9/77 Celsius
|
||||
Temperature History Size (Index): 128 (26)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 66 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x8001 2 0 Vendor specific
|
||||
|
||||
|
||||
|
||||
192
HDD/Samsung/HM320/HM320JI/6A9B4A56F398
Normal file
192
HDD/Samsung/HM320/HM320JI/6A9B4A56F398
Normal file
@@ -0,0 +1,192 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint M6
|
||||
Device Model: SAMSUNG HM320JI
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0f0000 ...
|
||||
Firmware Version: 2SS00_01
|
||||
User Capacity: 320,072,933,376 bytes [320 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 0
|
||||
SATA Version is: SATA 2.5, 1.5 Gb/s
|
||||
Local Time is: Mon May 25 21:13:29 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 111) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 111) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0
|
||||
3 Spin_Up_Time POS--- 252 252 025 - 2937
|
||||
4 Start_Stop_Count -O--CK 070 070 000 - 30996
|
||||
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
|
||||
7 Seek_Error_Rate -OSR-- 252 252 051 - 0
|
||||
8 Seek_Time_Performance --S--K 252 252 015 - 0
|
||||
9 Power_On_Hours -O--CK 089 089 000 - 6214
|
||||
10 Spin_Retry_Count -O--CK 100 100 051 - 9
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3223
|
||||
191 G-Sense_Error_Rate -O--CK 096 096 000 - 45273
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 105
|
||||
194 Temperature_Celsius -O---K 124 079 000 - 38 (Min/Max 11/53)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 252 252 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 252 252 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
|
||||
201 Soft_Read_Error_Rate -O--CK 252 252 000 - 0
|
||||
223 Load_Retry_Count -O--CK 100 100 000 - 573
|
||||
225 Load_Cycle_Count -O--CK 079 079 000 - 221085
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x08 SL R/O 1 Power Conditions log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80 GPL,SL R/W 16 Host vendor specific log
|
||||
0x81-0x9f SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
Device Error Count: 1
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 1623 hours (67 days + 15 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 08 00 00 02 4c b1 43 40 00 Error: ABRT at LBA = 0x024cb143 = 38580547
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 08 0a 58 00 00 02 4c e8 93 40 00 00:00:10.750 WRITE FPDMA QUEUED
|
||||
61 00 08 09 50 00 00 02 4c b1 43 40 00 00:00:10.687 WRITE FPDMA QUEUED
|
||||
61 00 08 08 48 00 00 00 18 80 63 40 00 00:00:10.687 WRITE FPDMA QUEUED
|
||||
61 00 08 07 40 00 00 00 16 79 63 40 00 00:00:10.687 WRITE FPDMA QUEUED
|
||||
61 00 10 06 38 00 00 00 16 79 03 40 00 00:00:10.687 WRITE FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 5541 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Completed [00% left] (0-65535)
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/38 Celsius
|
||||
Lifetime Min/Max Temperature: 11/53 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 15/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (83)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x8001 2 0 Vendor specific
|
||||
|
||||
43
HDD/Samsung/README.md
Normal file
43
HDD/Samsung/README.md
Normal file
@@ -0,0 +1,43 @@
|
||||
Samsung Hard Drives
|
||||
===================
|
||||
|
||||
This is a list of all tested Samsung hard drive models and their MTBFs. See more
|
||||
info on reliability test in the [README](https://github.com/bsdhw/SMART).
|
||||
|
||||
Contents
|
||||
--------
|
||||
|
||||
1. [ HDD by Model ](#hdd-by-model)
|
||||
2. [ HDD by Family ](#hdd-by-family)
|
||||
|
||||
HDD by Model
|
||||
------------
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Model | Size | Samples | Days | Err | MTBF |
|
||||
|-----------|--------------------|--------|---------|-------|-------|--------|
|
||||
| Samsung | HD501LJ | 500 GB | 4 | 3871 | 3 | 5.15 |
|
||||
| Samsung | HM320JI | 320 GB | 1 | 258 | 9 | 0.07 |
|
||||
|
||||
HDD by Family
|
||||
-------------
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Family | Models | Samples | Days | Err | MTBF |
|
||||
|-----------|------------------------|--------|---------|-------|-------|--------|
|
||||
| Samsung | SpinPoint T166 | 1 | 4 | 3871 | 3 | 5.15 |
|
||||
| Samsung | SpinPoint M6 | 1 | 1 | 258 | 9 | 0.07 |
|
||||
98
HDD/Seagate/README.md
Normal file
98
HDD/Seagate/README.md
Normal file
@@ -0,0 +1,98 @@
|
||||
Seagate Hard Drives
|
||||
===================
|
||||
|
||||
This is a list of all tested Seagate hard drive models and their MTBFs. See more
|
||||
info on reliability test in the [README](https://github.com/bsdhw/SMART).
|
||||
|
||||
Contents
|
||||
--------
|
||||
|
||||
1. [ HDD by Model ](#hdd-by-model)
|
||||
2. [ HDD by Family ](#hdd-by-family)
|
||||
|
||||
HDD by Model
|
||||
------------
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Model | Size | Samples | Days | Err | MTBF |
|
||||
|-----------|--------------------|--------|---------|-------|-------|--------|
|
||||
| Seagate | ST3120023A | 120 GB | 1 | 5214 | 0 | 14.29 |
|
||||
| Seagate | ST3500630NS | 500 GB | 1 | 4005 | 0 | 10.97 |
|
||||
| Seagate | ST3160318AS | 160 GB | 1 | 2290 | 0 | 6.27 |
|
||||
| Seagate | ST4000NM0033-9Z... | 4 TB | 3 | 1988 | 0 | 5.45 |
|
||||
| Seagate | ST3320620A | 320 GB | 1 | 1913 | 0 | 5.24 |
|
||||
| Seagate | ST3500413AS | 500 GB | 2 | 1885 | 0 | 5.17 |
|
||||
| Seagate | ST1000NC001-1DY162 | 1 TB | 1 | 1848 | 0 | 5.06 |
|
||||
| Seagate | ST3320620AS | 320 GB | 1 | 1737 | 0 | 4.76 |
|
||||
| Seagate | ST3250318AS | 250 GB | 1 | 1636 | 0 | 4.48 |
|
||||
| Seagate | ST91000640NS | 1 TB | 1 | 1630 | 0 | 4.47 |
|
||||
| Seagate | ST5000DM000-1FK178 | 5 TB | 1 | 1387 | 0 | 3.80 |
|
||||
| Seagate | ST9250315AS | 250 GB | 1 | 1192 | 0 | 3.27 |
|
||||
| Seagate | ST4000LM016-1N2170 | 4 TB | 1 | 1146 | 0 | 3.14 |
|
||||
| Seagate | ST4000DM000-1F2168 | 4 TB | 2 | 1098 | 0 | 3.01 |
|
||||
| Seagate | ST320VT000-1BS14C | 320 GB | 1 | 1083 | 0 | 2.97 |
|
||||
| Seagate | ST3160023A | 160 GB | 1 | 1056 | 0 | 2.89 |
|
||||
| Seagate | ST3250312AS | 250 GB | 1 | 1039 | 0 | 2.85 |
|
||||
| Seagate | ST6000DM003-2CY186 | 6 TB | 1 | 765 | 0 | 2.10 |
|
||||
| Seagate | ST2000DM001-1CH164 | 2 TB | 3 | 1143 | 51 | 1.97 |
|
||||
| Seagate | ST8000VN0022-2E... | 8 TB | 1 | 658 | 0 | 1.80 |
|
||||
| Seagate | ST8000VN0002-1Z... | 8 TB | 1 | 625 | 0 | 1.71 |
|
||||
| Seagate | ST1000VX000-1CU162 | 1 TB | 1 | 596 | 0 | 1.63 |
|
||||
| Seagate | ST2000LM015-2E8174 | 2 TB | 2 | 430 | 0 | 1.18 |
|
||||
| Seagate | ST380811AS | 80 GB | 1 | 383 | 0 | 1.05 |
|
||||
| Seagate | ST1000LM024 HN-... | 1 TB | 1 | 347 | 0 | 0.95 |
|
||||
| Seagate | ST4000VN008-2DR166 | 4 TB | 1 | 239 | 0 | 0.66 |
|
||||
| Seagate | ST500LM012 HN-M... | 500 GB | 1 | 213 | 0 | 0.59 |
|
||||
| Seagate | ST2000LM007-1R8174 | 2 TB | 1 | 111 | 0 | 0.31 |
|
||||
| Seagate | ST500LM030-2E717D | 500 GB | 1 | 55 | 0 | 0.15 |
|
||||
| Seagate | ST500LM021-1KJ152 | 500 GB | 2 | 227 | 505 | 0.14 |
|
||||
| Seagate | ST1000LM048-2E7172 | 1 TB | 1 | 44 | 0 | 0.12 |
|
||||
| Seagate | ST12000VN0008-2... | 12 TB | 16 | 3 | 0 | 0.01 |
|
||||
| Seagate | ST3500514NS | 500 GB | 1 | 205 | 103 | 0.01 |
|
||||
| Seagate | ST2000DM008-2FR102 | 2 TB | 1 | 161 | 144 | 0.00 |
|
||||
| Seagate | ST9500420AS | 500 GB | 1 | 315 | 738 | 0.00 |
|
||||
|
||||
HDD by Family
|
||||
-------------
|
||||
|
||||
Please take all columns into account when reading the table. Pay attention on the
|
||||
number of tested samples and power-on days. Simultaneous high values of both MTBF
|
||||
and errors are possible if only rare drives in the subset encounter errors.
|
||||
|
||||
Days — avg. days per sample,
|
||||
Err — avg. errors per sample,
|
||||
MTBF — avg. MTBF in years per sample.
|
||||
|
||||
| MFG | Family | Models | Samples | Days | Err | MTBF |
|
||||
|-----------|------------------------|--------|---------|-------|-------|--------|
|
||||
| Seagate | Barracuda ATA V | 1 | 1 | 5214 | 0 | 14.29 |
|
||||
| Seagate | Barracuda ES | 1 | 1 | 4005 | 0 | 10.97 |
|
||||
| Seagate | Constellation ES.3 | 1 | 3 | 1988 | 0 | 5.45 |
|
||||
| Seagate | Constellation CS | 1 | 1 | 1848 | 0 | 5.06 |
|
||||
| Seagate | Barracuda 7200.10 | 2 | 2 | 1825 | 0 | 5.00 |
|
||||
| Seagate | Barracuda 7200.12 | 4 | 5 | 1747 | 0 | 4.79 |
|
||||
| Seagate | Constellation.2 (SATA) | 1 | 1 | 1630 | 0 | 4.47 |
|
||||
| Seagate | Desktop HDD.15 | 2 | 3 | 1194 | 0 | 3.27 |
|
||||
| Seagate | Momentus 5400.6 | 1 | 1 | 1192 | 0 | 3.27 |
|
||||
| Seagate | Unknown | 1 | 1 | 1083 | 0 | 2.97 |
|
||||
| Seagate | Barracuda 7200.7 an... | 1 | 1 | 1056 | 0 | 2.89 |
|
||||
| Seagate | Barracuda Compute | 1 | 1 | 765 | 0 | 2.10 |
|
||||
| Seagate | Barracuda 7200.14 (AF) | 1 | 3 | 1143 | 51 | 1.97 |
|
||||
| Seagate | NAS HDD | 1 | 1 | 625 | 0 | 1.71 |
|
||||
| Seagate | Surveillance | 1 | 1 | 596 | 0 | 1.63 |
|
||||
| Seagate | Laptop HDD | 2 | 3 | 534 | 337 | 1.14 |
|
||||
| Seagate | Barracuda 7200.9 | 1 | 1 | 383 | 0 | 1.05 |
|
||||
| Seagate | SpinPoint M8 (AF) | 2 | 2 | 280 | 0 | 0.77 |
|
||||
| Seagate | Barracuda 2.5 5400 | 3 | 4 | 240 | 0 | 0.66 |
|
||||
| Seagate | Mobile HDD | 1 | 1 | 111 | 0 | 0.31 |
|
||||
| Seagate | IronWolf | 3 | 18 | 53 | 0 | 0.15 |
|
||||
| Seagate | Constellation ES (S... | 1 | 1 | 205 | 103 | 0.01 |
|
||||
| Seagate | BarraCuda 3.5 | 1 | 1 | 161 | 144 | 0.00 |
|
||||
| Seagate | Momentus 7200.4 | 1 | 1 | 315 | 738 | 0.00 |
|
||||
191
HDD/Seagate/ST1000/ST1000LM024 HN-M101MBB/CCA7C0EF0228
Normal file
191
HDD/Seagate/ST1000/ST1000LM024 HN-M101MBB/CCA7C0EF0228
Normal file
@@ -0,0 +1,191 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Samsung SpinPoint M8 (AF)
|
||||
Device Model: ST1000LM024 HN-M101MBB
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0004cf ...
|
||||
Firmware Version: 2AR10002
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon May 25 18:33:37 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (12780) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 213) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 19
|
||||
2 Throughput_Performance -OS--K 252 252 000 - 0
|
||||
3 Spin_Up_Time PO---K 089 089 025 - 3466
|
||||
4 Start_Stop_Count -O--CK 095 095 000 - 5511
|
||||
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
|
||||
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
|
||||
8 Seek_Time_Performance --S--K 252 252 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 8331
|
||||
10 Spin_Retry_Count -O--CK 252 252 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 195
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1946
|
||||
191 G-Sense_Error_Rate -O---K 100 100 000 - 231
|
||||
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
|
||||
194 Temperature_Celsius -O---- 051 040 000 - 49 (Min/Max 11/62)
|
||||
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 252 252 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 252 252 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 9534
|
||||
223 Load_Retry_Count -O--CK 100 100 000 - 195
|
||||
225 Load_Cycle_Count -O--CK 053 053 000 - 476749
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 2 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xc0-0xdf GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (2 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Completed [00% left] (0-65535)
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 49 Celsius
|
||||
Power Cycle Min/Max Temperature: 42/51 Celsius
|
||||
Lifetime Min/Max Temperature: 13/62 Celsius
|
||||
Specified Max Operating Temperature: 80 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 5 minutes
|
||||
Temperature Logging Interval: 5 minutes
|
||||
Min/Max recommended Temperature: -5/80 Celsius
|
||||
Min/Max Temperature Limit: -10/85 Celsius
|
||||
Temperature History Size (Index): 128 (94)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0002 4 0 R_ERR response for data FIS
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 4 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 12 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x8e00 4 0 Vendor specific
|
||||
0x8e01 4 0 Vendor specific
|
||||
0x8e02 4 0 Vendor specific
|
||||
0x8e03 4 0 Vendor specific
|
||||
0x8e04 4 0 Vendor specific
|
||||
0x8e05 4 0 Vendor specific
|
||||
0x8e06 4 0 Vendor specific
|
||||
0x8e07 4 0 Vendor specific
|
||||
0x8e08 4 0 Vendor specific
|
||||
0x8e09 4 0 Vendor specific
|
||||
0x8e0a 4 0 Vendor specific
|
||||
0x8e0b 4 0 Vendor specific
|
||||
0x8e0c 4 0 Vendor specific
|
||||
0x8e0d 4 0 Vendor specific
|
||||
0x8e0e 4 0 Vendor specific
|
||||
0x8e0f 4 0 Vendor specific
|
||||
0x8e10 4 0 Vendor specific
|
||||
0x8e11 4 0 Vendor specific
|
||||
|
||||
204
HDD/Seagate/ST1000/ST1000LM048-2E7172/D377199C1EDD
Normal file
204
HDD/Seagate/ST1000/ST1000LM048-2E7172/D377199C1EDD
Normal file
@@ -0,0 +1,204 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 2.5 5400
|
||||
Device Model: ST1000LM048-2E7172
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun May 31 09:39:03 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 163) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 083 064 006 - 209629381
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1150
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 077 060 045 - 56010470
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 1059 (149 254 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 160
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 065 053 040 - 35 (Min/Max 19/35)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 13
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 23
|
||||
193 Load_Cycle_Count -O--CK 099 099 000 - 2107
|
||||
194 Temperature_Celsius -O---K 035 047 000 - 35 (0 10 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 976 (13 20 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 2958959469
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 4819180323
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa8 GPL,SL VS 136 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 8920 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc2 GPL,SL VS 240 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/35 Celsius
|
||||
Lifetime Min/Max Temperature: 10/48 Celsius
|
||||
Specified Max Operating Temperature: 39 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 30 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (72)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 160 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1059 --- Power-on Hours
|
||||
0x01 0x018 6 2956689312 --- Logical Sectors Written
|
||||
0x01 0x020 6 50295528 --- Number of Write Commands
|
||||
0x01 0x028 6 4819430698 --- Logical Sectors Read
|
||||
0x01 0x030 6 65423896 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 1054 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 975 --- Head Flying Hours
|
||||
0x03 0x018 4 2107 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
173
HDD/Seagate/ST1000/ST1000NC001-1DY162/56F4A6E70590
Normal file
173
HDD/Seagate/ST1000/ST1000NC001-1DY162/56F4A6E70590
Normal file
@@ -0,0 +1,173 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 13.0-CURRENT amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Constellation CS
|
||||
Device Model: ST1000NC001-1DY162
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CN02
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 15:05:48 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 592) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 112) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x10bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 082 063 044 - 191925984
|
||||
3 Spin_Up_Time PO---- 097 097 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 101
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 077 060 030 - 52202989
|
||||
9 Power_On_Hours -O--CK 050 050 000 - 44363
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 102
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 073 056 045 - 27 (Min/Max 25/36)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 55
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 102
|
||||
194 Temperature_Celsius -O---K 027 044 000 - 27 (0 15 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL,SL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/36 Celsius
|
||||
Lifetime Min/Max Temperature: 15/44 Celsius
|
||||
Under/Over Temperature Limit Count: 0/2997
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (104)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 100 (10.0 seconds)
|
||||
Write: 100 (10.0 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 30 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
173
HDD/Seagate/ST1000/ST1000VX000-1CU162/FA598C1BF090
Normal file
173
HDD/Seagate/ST1000/ST1000VX000-1CU162/FA598C1BF090
Normal file
@@ -0,0 +1,173 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Surveillance
|
||||
Device Model: ST1000VX000-1CU162
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CV22
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 18:20:45 2020 +06
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 72) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 102) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x10b9) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 115 099 006 - 91871976
|
||||
3 Spin_Up_Time PO---- 097 097 000 - 0
|
||||
4 Start_Stop_Count -O--CK 097 097 020 - 3399
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 084 060 030 - 4594868805
|
||||
9 Power_On_Hours -O--CK 084 084 000 - 14312
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 020 - 3398
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 001 001 000 - 1267
|
||||
190 Airflow_Temperature_Cel -O---K 062 058 045 - 38 (Min/Max 24/38)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 28
|
||||
193 Load_Cycle_Count -O--CK 099 099 000 - 3399
|
||||
194 Temperature_Celsius -O---K 038 042 000 - 38 (0 18 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 8609 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/38 Celsius
|
||||
Lifetime Min/Max Temperature: 18/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 94 minutes
|
||||
Min/Max recommended Temperature: 1/61 Celsius
|
||||
Min/Max Temperature Limit: 2/60 Celsius
|
||||
Temperature History Size (Index): 128 (77)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/0A188F1CD3BA
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/0A188F1CD3BA
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:28 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1170) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 069 064 044 - 8337848
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1509164
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 90
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 067 044 040 - 33 (Min/Max 20/36)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 17
|
||||
194 Temperature_Celsius -O---K 033 040 000 - 33 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 069 064 000 - 8337848
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (162 104 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 250924994
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1553523
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/36 Celsius
|
||||
Lifetime Min/Max Temperature: 20/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/87
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 90 --- Power-on Hours
|
||||
0x01 0x018 6 250924994 --- Logical Sectors Written
|
||||
0x01 0x020 6 2795359 --- Number of Write Commands
|
||||
0x01 0x028 6 1553523 --- Logical Sectors Read
|
||||
0x01 0x030 6 64198 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 90 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 90 --- Head Flying Hours
|
||||
0x03 0x018 4 17 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 31 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 36 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 31 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 29 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/144085CA4BA4
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/144085CA4BA4
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:27 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 575) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1173) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 069 064 044 - 8307232
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1444293
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 90
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 068 045 040 - 32 (Min/Max 20/35)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 19
|
||||
194 Temperature_Celsius -O---K 032 040 000 - 32 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 069 064 000 - 8307232
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (182 85 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 250893402
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1554477
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/35 Celsius
|
||||
Lifetime Min/Max Temperature: 20/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/80
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 90 --- Power-on Hours
|
||||
0x01 0x018 6 250893402 --- Logical Sectors Written
|
||||
0x01 0x020 6 2792928 --- Number of Write Commands
|
||||
0x01 0x028 6 1554477 --- Logical Sectors Read
|
||||
0x01 0x030 6 64117 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 90 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 90 --- Head Flying Hours
|
||||
0x03 0x018 4 19 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x010 1 30 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 35 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 30 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/21AADC862859
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/21AADC862859
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:35 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1176) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 066 064 044 - 4223088
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 061 060 045 - 1392495
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 89
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 070 049 040 - 30 (Min/Max 20/33)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 13
|
||||
194 Temperature_Celsius -O---K 030 040 000 - 30 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 066 064 000 - 4223088
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (31 24 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 246782090
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1581624
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/33 Celsius
|
||||
Lifetime Min/Max Temperature: 20/51 Celsius
|
||||
Under/Over Temperature Limit Count: 0/66
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 89 --- Power-on Hours
|
||||
0x01 0x018 6 246782090 --- Logical Sectors Written
|
||||
0x01 0x020 6 2743331 --- Number of Write Commands
|
||||
0x01 0x028 6 1581624 --- Logical Sectors Read
|
||||
0x01 0x030 6 63667 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 89 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 89 --- Head Flying Hours
|
||||
0x03 0x018 4 13 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x010 1 27 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 33 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 28 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 26 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/3BE93499BD79
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/3BE93499BD79
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:34 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1172) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 066 064 044 - 4208504
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1468951
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 89
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 067 045 040 - 33 (Min/Max 20/35)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 13
|
||||
194 Temperature_Celsius -O---K 033 040 000 - 33 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 066 064 000 - 4208504
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (189 199 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 246764986
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1584173
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/35 Celsius
|
||||
Lifetime Min/Max Temperature: 20/54 Celsius
|
||||
Under/Over Temperature Limit Count: 0/82
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 89 --- Power-on Hours
|
||||
0x01 0x018 6 246764986 --- Logical Sectors Written
|
||||
0x01 0x020 6 2743547 --- Number of Write Commands
|
||||
0x01 0x028 6 1584173 --- Logical Sectors Read
|
||||
0x01 0x030 6 63914 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 89 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 89 --- Head Flying Hours
|
||||
0x03 0x018 4 13 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 30 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 35 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 30 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/3ED8AEB0B74D
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/3ED8AEB0B74D
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:25 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1172) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 069 064 044 - 8335048
|
||||
3 Spin_Up_Time PO---- 097 097 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 2
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1443703
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 90
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 2
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 068 066 040 - 32 (Min/Max 22/34)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 22
|
||||
194 Temperature_Celsius -O---K 032 040 000 - 32 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 069 064 000 - 8335048
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (202 206 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 250914810
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1560877
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/34 Celsius
|
||||
Lifetime Min/Max Temperature: 20/34 Celsius
|
||||
Under/Over Temperature Limit Count: 0/79
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (95)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 2 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 90 --- Power-on Hours
|
||||
0x01 0x018 6 250914810 --- Logical Sectors Written
|
||||
0x01 0x020 6 2799030 --- Number of Write Commands
|
||||
0x01 0x028 6 1560877 --- Logical Sectors Read
|
||||
0x01 0x030 6 64629 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 90 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 90 --- Head Flying Hours
|
||||
0x03 0x018 4 22 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x010 1 29 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 34 --- Highest Temperature
|
||||
0x05 0x028 1 22 --- Lowest Temperature
|
||||
0x05 0x030 1 29 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/442769CE2E0F
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/442769CE2E0F
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:29 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1174) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 070 064 044 - 11093184
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1559297
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 90
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 068 066 040 - 32 (Min/Max 20/34)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 17
|
||||
194 Temperature_Celsius -O---K 032 040 000 - 32 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 070 064 000 - 11093184
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (122 20 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 253569490
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1664510
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/34 Celsius
|
||||
Lifetime Min/Max Temperature: 20/34 Celsius
|
||||
Under/Over Temperature Limit Count: 0/79
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 90 --- Power-on Hours
|
||||
0x01 0x018 6 253569490 --- Logical Sectors Written
|
||||
0x01 0x020 6 2914856 --- Number of Write Commands
|
||||
0x01 0x028 6 1664510 --- Logical Sectors Read
|
||||
0x01 0x030 6 68445 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 90 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 90 --- Head Flying Hours
|
||||
0x03 0x018 4 17 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x010 1 29 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 34 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 30 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/451BE7BB8810
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/451BE7BB8810
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:30 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1163) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 070 064 044 - 11084816
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1534887
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 90
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 070 049 040 - 30 (Min/Max 20/33)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 17
|
||||
194 Temperature_Celsius -O---K 030 040 000 - 30 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 070 064 000 - 11084816
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (40 49 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 253570418
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1655263
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/33 Celsius
|
||||
Lifetime Min/Max Temperature: 20/51 Celsius
|
||||
Under/Over Temperature Limit Count: 0/67
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 90 --- Power-on Hours
|
||||
0x01 0x018 6 253570418 --- Logical Sectors Written
|
||||
0x01 0x020 6 2912658 --- Number of Write Commands
|
||||
0x01 0x028 6 1655263 --- Logical Sectors Read
|
||||
0x01 0x030 6 68113 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 90 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 90 --- Head Flying Hours
|
||||
0x03 0x018 4 17 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x010 1 27 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 33 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 28 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 26 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/563B961B0EB5
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/563B961B0EB5
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:30 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 575) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1176) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 066 064 044 - 4173000
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1422451
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 90
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 067 045 040 - 33 (Min/Max 20/36)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 14
|
||||
194 Temperature_Celsius -O---K 033 040 000 - 33 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 066 064 000 - 4173000
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (58 207 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 246734450
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1579182
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/36 Celsius
|
||||
Lifetime Min/Max Temperature: 20/54 Celsius
|
||||
Under/Over Temperature Limit Count: 0/88
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 90 --- Power-on Hours
|
||||
0x01 0x018 6 246734450 --- Logical Sectors Written
|
||||
0x01 0x020 6 2743255 --- Number of Write Commands
|
||||
0x01 0x028 6 1579182 --- Logical Sectors Read
|
||||
0x01 0x030 6 63682 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 90 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 89 --- Head Flying Hours
|
||||
0x03 0x018 4 14 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 31 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 36 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 31 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 29 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/650F39F95C89
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/650F39F95C89
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:26 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 575) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1172) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 069 064 044 - 8289016
|
||||
3 Spin_Up_Time PO---- 097 097 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 2
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1511144
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 90
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 2
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 069 066 040 - 31 (Min/Max 22/34)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 22
|
||||
194 Temperature_Celsius -O---K 031 040 000 - 31 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 069 064 000 - 8289016
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (228 4 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 250874802
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1554869
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/34 Celsius
|
||||
Lifetime Min/Max Temperature: 20/34 Celsius
|
||||
Under/Over Temperature Limit Count: 0/76
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (95)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 2 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 90 --- Power-on Hours
|
||||
0x01 0x018 6 250874802 --- Logical Sectors Written
|
||||
0x01 0x020 6 2794943 --- Number of Write Commands
|
||||
0x01 0x028 6 1554869 --- Logical Sectors Read
|
||||
0x01 0x030 6 64107 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 90 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 90 --- Head Flying Hours
|
||||
0x03 0x018 4 22 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 31 --- Current Temperature
|
||||
0x05 0x010 1 29 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 34 --- Highest Temperature
|
||||
0x05 0x028 1 22 --- Lowest Temperature
|
||||
0x05 0x030 1 29 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 27 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/654AE1257A4E
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/654AE1257A4E
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:34 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1173) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 068 064 044 - 6963928
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1476038
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 89
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 067 045 040 - 33 (Min/Max 20/35)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 13
|
||||
194 Temperature_Celsius -O---K 033 040 000 - 33 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 068 064 000 - 6963928
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (200 223 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 249418530
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1686205
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/35 Celsius
|
||||
Lifetime Min/Max Temperature: 20/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/83
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 89 --- Power-on Hours
|
||||
0x01 0x018 6 249418530 --- Logical Sectors Written
|
||||
0x01 0x020 6 2871521 --- Number of Write Commands
|
||||
0x01 0x028 6 1686205 --- Logical Sectors Read
|
||||
0x01 0x030 6 67232 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 89 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 89 --- Head Flying Hours
|
||||
0x03 0x018 4 13 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 30 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 35 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 30 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 29 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/661707D1EB57
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/661707D1EB57
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:24 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1169) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 070 064 044 - 11085248
|
||||
3 Spin_Up_Time PO---- 097 097 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 2
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1571837
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 90
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 2
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 070 067 040 - 30 (Min/Max 21/33)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 22
|
||||
194 Temperature_Celsius -O---K 030 040 000 - 30 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 070 064 000 - 11085248
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (237 60 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 253570394
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1655485
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/33 Celsius
|
||||
Lifetime Min/Max Temperature: 20/33 Celsius
|
||||
Under/Over Temperature Limit Count: 0/68
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (95)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 2 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 90 --- Power-on Hours
|
||||
0x01 0x018 6 253570506 --- Logical Sectors Written
|
||||
0x01 0x020 6 2910388 --- Number of Write Commands
|
||||
0x01 0x028 6 1655485 --- Logical Sectors Read
|
||||
0x01 0x030 6 68296 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 90 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 90 --- Head Flying Hours
|
||||
0x03 0x018 4 22 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x010 1 28 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 33 --- Highest Temperature
|
||||
0x05 0x028 1 21 --- Lowest Temperature
|
||||
0x05 0x030 1 28 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 26 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/78504B519B2A
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/78504B519B2A
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:33 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1142) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 068 064 044 - 6949688
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1475473
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 89
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 068 044 040 - 32 (Min/Max 20/35)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 13
|
||||
194 Temperature_Celsius -O---K 032 040 000 - 32 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 068 064 000 - 6949688
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (101 98 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 249412594
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1677871
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/35 Celsius
|
||||
Lifetime Min/Max Temperature: 20/56 Celsius
|
||||
Under/Over Temperature Limit Count: 0/78
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 89 --- Power-on Hours
|
||||
0x01 0x018 6 249412594 --- Logical Sectors Written
|
||||
0x01 0x020 6 2868200 --- Number of Write Commands
|
||||
0x01 0x028 6 1677871 --- Logical Sectors Read
|
||||
0x01 0x030 6 67198 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 89 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 89 --- Head Flying Hours
|
||||
0x03 0x018 4 13 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x010 1 29 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 35 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 30 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 27 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/7C8BF5C82E69
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/7C8BF5C82E69
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:27 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 575) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1178) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 070 064 044 - 11086528
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1582007
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 90
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 070 044 040 - 30 (Min/Max 20/32)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 21
|
||||
194 Temperature_Celsius -O---K 030 040 000 - 30 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 070 064 000 - 11086528
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (105 69 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 253573866
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1653299
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/32 Celsius
|
||||
Lifetime Min/Max Temperature: 20/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/63
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 90 --- Power-on Hours
|
||||
0x01 0x018 6 253573866 --- Logical Sectors Written
|
||||
0x01 0x020 6 2910568 --- Number of Write Commands
|
||||
0x01 0x028 6 1653299 --- Logical Sectors Read
|
||||
0x01 0x030 6 67934 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 90 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 90 --- Head Flying Hours
|
||||
0x03 0x018 4 21 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 30 --- Current Temperature
|
||||
0x05 0x010 1 27 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 32 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 28 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 26 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/811E3EF98400
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/811E3EF98400
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:31 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 575) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1172) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 068 064 044 - 6949136
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1525345
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 90
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 066 045 040 - 34 (Min/Max 20/36)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 15
|
||||
194 Temperature_Celsius -O---K 034 040 000 - 34 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 068 064 000 - 6949136
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (95 65 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 249412866
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1677051
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/36 Celsius
|
||||
Lifetime Min/Max Temperature: 20/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/89
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 90 --- Power-on Hours
|
||||
0x01 0x018 6 249412866 --- Logical Sectors Written
|
||||
0x01 0x020 6 2875558 --- Number of Write Commands
|
||||
0x01 0x028 6 1677051 --- Logical Sectors Read
|
||||
0x01 0x030 6 66849 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 90 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 89 --- Head Flying Hours
|
||||
0x03 0x018 4 15 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 34 --- Current Temperature
|
||||
0x05 0x010 1 31 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 36 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 31 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 30 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/8AC9E335B746
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/8AC9E335B746
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:32 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1173) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 066 064 044 - 4164880
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1465642
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 90
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 069 045 040 - 31 (Min/Max 20/33)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 15
|
||||
194 Temperature_Celsius -O---K 031 040 000 - 31 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 066 064 000 - 4164880
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (198 182 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 246726474
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1579045
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/34 Celsius
|
||||
Lifetime Min/Max Temperature: 20/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/72
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 90 --- Power-on Hours
|
||||
0x01 0x018 6 246726474 --- Logical Sectors Written
|
||||
0x01 0x020 6 2741077 --- Number of Write Commands
|
||||
0x01 0x028 6 1579045 --- Logical Sectors Read
|
||||
0x01 0x030 6 63718 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 90 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 89 --- Head Flying Hours
|
||||
0x03 0x018 4 15 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 31 --- Current Temperature
|
||||
0x05 0x010 1 28 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 33 --- Highest Temperature
|
||||
0x05 0x028 1 21 --- Lowest Temperature
|
||||
0x05 0x030 1 29 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 27 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/C8E0C70F49ED
Normal file
244
HDD/Seagate/ST1200/ST12000VN0008-2JH101/C8E0C70F49ED
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST12000VN0008-2JH101
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 12,000,138,625,024 bytes [12.0 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-4 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 23 12:35:32 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Disabled
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0x000d (action_code=0, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: (1172) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 068 064 044 - 6951512
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 1
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 045 - 1475419
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 90
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
||||
18 Unknown_Attribute PO-R-- 100 100 050 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 067 049 040 - 33 (Min/Max 20/35)
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 15
|
||||
194 Temperature_Celsius -O---K 033 040 000 - 33 (0 20 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 068 064 000 - 6951512
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 89 (251 80 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 249413018
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1679251
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 256 Device Statistics log
|
||||
0x04 SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0a GPL R/W 8 Device Statistics Notification
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 768 Current Device Internal Status Data log
|
||||
0x2f GPL - 1 Set Sector Configuration
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 16320 Device vendor specific log
|
||||
0xa4 GPL,SL VS 160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xad GPL VS 16 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 8 Device vendor specific log
|
||||
0xc3 GPL,SL VS 32 Device vendor specific log
|
||||
0xc9 GPL,SL VS 8 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 336 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd4 GPL VS 2048 Device vendor specific log
|
||||
0xda GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/35 Celsius
|
||||
Lifetime Min/Max Temperature: 20/51 Celsius
|
||||
Under/Over Temperature Limit Count: 0/83
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 03 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 10/25 Celsius
|
||||
Min/Max Temperature Limit: 5/70 Celsius
|
||||
Temperature History Size (Index): 128 (93)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 90 --- Power-on Hours
|
||||
0x01 0x018 6 249413018 --- Logical Sectors Written
|
||||
0x01 0x020 6 2871291 --- Number of Write Commands
|
||||
0x01 0x028 6 1679251 --- Logical Sectors Read
|
||||
0x01 0x030 6 66869 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 90 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 89 --- Head Flying Hours
|
||||
0x03 0x018 4 15 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 0 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x04 0x018 4 0 -D- Physical Element Status Changed
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 30 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 35 --- Highest Temperature
|
||||
0x05 0x028 1 20 --- Lowest Temperature
|
||||
0x05 0x030 1 30 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 29 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0xff ===== = = === == Vendor Specific Statistics (rev 1) ==
|
||||
0xff 0x008 7 0 --- Vendor Specific
|
||||
0xff 0x010 7 0 --- Vendor Specific
|
||||
0xff 0x018 7 0 --- Vendor Specific
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
168
HDD/Seagate/ST2000/ST2000DM001-1CH164/183CF84B7E96
Normal file
168
HDD/Seagate/ST2000/ST2000DM001-1CH164/183CF84B7E96
Normal file
@@ -0,0 +1,168 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST2000DM001-1CH164
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC27
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed May 27 00:19:35 2020 +07
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 584) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 223) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 118 099 006 - 191230464
|
||||
3 Spin_Up_Time PO---- 096 096 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 107
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 086 060 030 - 4739546676
|
||||
9 Power_On_Hours -O--CK 065 065 000 - 30797
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 107
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 001 001 099 NOW 153
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0 0 0
|
||||
189 High_Fly_Writes -O-RCK 079 079 000 - 21
|
||||
190 Airflow_Temperature_Cel -O---K 055 043 045 Past 45 (Min/Max 39/47 #98)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 69
|
||||
193 Load_Cycle_Count -O--CK 076 076 000 - 48407
|
||||
194 Temperature_Celsius -O---K 045 057 000 - 45 (0 15 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 23354h+36m+14.855s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 418478352665
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 7149547768
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 42 Celsius
|
||||
Power Cycle Min/Max Temperature: 39/47 Celsius
|
||||
Lifetime Min/Max Temperature: 15/57 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
175
HDD/Seagate/ST2000/ST2000DM001-1CH164/62A4A80CFE9C
Normal file
175
HDD/Seagate/ST2000/ST2000DM001-1CH164/62A4A80CFE9C
Normal file
@@ -0,0 +1,175 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST2000DM001-1CH164
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: HP34
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed May 27 18:26:49 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 584) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x53) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 222) minutes.
|
||||
SCT capabilities: (0x303b) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 117 099 006 - 148729032
|
||||
3 Spin_Up_Time PO---K 096 096 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1338
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-K 081 060 030 - 131729840
|
||||
9 Power_On_Hours -O--CK 083 083 000 - 15120
|
||||
10 Spin_Retry_Count PO--CK 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1323
|
||||
180 Unknown_HDD_Attribute -O-R-K 100 100 000 - 1734537341
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0 0 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 068 060 045 - 32 (Min/Max 23/32)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 499
|
||||
193 Load_Cycle_Count -O--CK 037 037 000 - 127252
|
||||
194 Temperature_Celsius -O---K 032 040 000 - 32 (0 11 0 0 0)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 036 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xb6 GPL VS 1918 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Aborted by host 90% 3 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/30 Celsius
|
||||
Lifetime Min/Max Temperature: 11/40 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (127)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
167
HDD/Seagate/ST2000/ST2000DM001-1CH164/D559A8F41E88
Normal file
167
HDD/Seagate/ST2000/ST2000DM001-1CH164/D559A8F41E88
Normal file
@@ -0,0 +1,167 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST2000DM001-1CH164
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC27
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed May 27 10:39:01 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 584) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 222) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 117 099 006 - 163518032
|
||||
3 Spin_Up_Time PO---- 096 096 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 83
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 088 060 030 - 796805842
|
||||
9 Power_On_Hours -O--CK 059 059 000 - 36440
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 83
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0 0 0
|
||||
189 High_Fly_Writes -O-RCK 094 094 000 - 6
|
||||
190 Airflow_Temperature_Cel -O---K 066 057 045 - 34 (Min/Max 22/41)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 57
|
||||
193 Load_Cycle_Count -O--CK 096 096 000 - 9346
|
||||
194 Temperature_Celsius -O---K 034 043 000 - 34 (0 18 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 27192h+21m+00.053s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 153267865116
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 61964074356
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/41 Celsius
|
||||
Lifetime Min/Max Temperature: 18/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 24 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
222
HDD/Seagate/ST2000/ST2000DM008-2FR102/ED7A60B17EA5
Normal file
222
HDD/Seagate/ST2000/ST2000DM008-2FR102/ED7A60B17EA5
Normal file
@@ -0,0 +1,222 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST2000DM008-2FR102
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 30 12:03:23 2020 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 200) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x30a5) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 065 048 006 - 126287008
|
||||
3 Spin_Up_Time PO---- 098 098 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 9
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 144
|
||||
7 Seek_Error_Rate POSR-- 087 060 045 - 463600715
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 3873 (36 161 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 9
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 061 058 040 - 39 (Min/Max 34/42)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 7
|
||||
193 Load_Cycle_Count -O--CK 095 095 000 - 10539
|
||||
194 Temperature_Celsius -O---K 039 042 000 - 39 (0 23 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 081 064 000 - 126287008
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 3667 (159 67 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 3846501253
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 24115478
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbd GPL VS 8 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xd1 GPL VS 264 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 34/42 Celsius
|
||||
Lifetime Min/Max Temperature: 23/42 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (39)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 9 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3873 --- Power-on Hours
|
||||
0x01 0x018 6 3846476892 --- Logical Sectors Written
|
||||
0x01 0x020 6 73823517 --- Number of Write Commands
|
||||
0x01 0x028 6 24112391 --- Logical Sectors Read
|
||||
0x01 0x030 6 1694674 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 3860 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 3668 --- Head Flying Hours
|
||||
0x03 0x018 4 10539 --- Head Load Events
|
||||
0x03 0x020 4 144 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 41 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 5 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 339 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 39 --- Current Temperature
|
||||
0x05 0x010 1 38 --- Average Short Term Temperature
|
||||
0x05 0x018 1 37 --- Average Long Term Temperature
|
||||
0x05 0x020 1 42 --- Highest Temperature
|
||||
0x05 0x028 1 27 --- Lowest Temperature
|
||||
0x05 0x030 1 40 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 34 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 37 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 34 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 34 --- Number of Hardware Resets
|
||||
0x06 0x010 4 5 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
202
HDD/Seagate/ST2000/ST2000LM007-1R8174/7F0DCB998EE6
Normal file
202
HDD/Seagate/ST2000/ST2000LM007-1R8174/7F0DCB998EE6
Normal file
@@ -0,0 +1,202 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Mobile HDD
|
||||
Device Model: ST2000LM007-1R8174
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: EB01
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 30 09:27:24 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 339) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 082 064 006 - 143908431
|
||||
3 Spin_Up_Time PO---- 098 098 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 657
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 074 060 045 - 24532984
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2683 (144 86 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 314
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 001 000 - 280
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 068 048 040 - 32 (Min/Max 30/37)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 4
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 52
|
||||
193 Load_Cycle_Count -O--CK 099 099 000 - 3656
|
||||
194 Temperature_Celsius -O---K 032 052 000 - 32 (0 14 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 600 (78 245 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 15895723091
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 12104442538
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa8 GPL,SL VS 136 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 8920 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc2 GPL,SL VS 240 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/37 Celsius
|
||||
Lifetime Min/Max Temperature: 14/52 Celsius
|
||||
Specified Max Operating Temperature: 29 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 30 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (118)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 314 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2683 --- Power-on Hours
|
||||
0x01 0x018 6 15895544000 --- Logical Sectors Written
|
||||
0x01 0x020 6 65086581 --- Number of Write Commands
|
||||
0x01 0x028 6 12103160909 --- Logical Sectors Read
|
||||
0x01 0x030 6 51860204 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 2337645997 N-- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 2337644812 N-- Head Flying Hours
|
||||
0x03 0x018 4 3656 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 5 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 273 --- Resets Between Cmd Acceptance and Completion
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
204
HDD/Seagate/ST2000/ST2000LM015-2E8174/AA3FB7EC6773
Normal file
204
HDD/Seagate/ST2000/ST2000LM015-2E8174/AA3FB7EC6773
Normal file
@@ -0,0 +1,204 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 2.5 5400
|
||||
Device Model: ST2000LM015-2E8174
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SDM1
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 20:11:56 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 325) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 081 065 006 - 118821485
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1520
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 068 060 045 - 5811111
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2802 (36 10 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1511
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 065 054 040 - 35 (Min/Max 22/35)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 1
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 11
|
||||
193 Load_Cycle_Count -O--CK 096 096 000 - 8884
|
||||
194 Temperature_Celsius -O---K 035 046 000 - 35 (0 11 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 939 (240 65 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 4291189917
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 5357492567
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa8 GPL,SL VS 136 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 8920 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc2 GPL,SL VS 240 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xc9 GPL,SL VS 1 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/35 Celsius
|
||||
Lifetime Min/Max Temperature: 11/46 Celsius
|
||||
Specified Max Operating Temperature: 37 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 30 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (94)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1511 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2802 --- Power-on Hours
|
||||
0x01 0x018 6 4326237805 --- Logical Sectors Written
|
||||
0x01 0x020 6 21114723 --- Number of Write Commands
|
||||
0x01 0x028 6 5392411133 --- Logical Sectors Read
|
||||
0x01 0x030 6 22833549 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 2799 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 9 --- Head Flying Hours
|
||||
0x03 0x018 4 8884 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
208
HDD/Seagate/ST2000/ST2000LM015-2E8174/B9CCD1AAE7DB
Normal file
208
HDD/Seagate/ST2000/ST2000LM015-2E8174/B9CCD1AAE7DB
Normal file
@@ -0,0 +1,208 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 2.5 5400
|
||||
Device Model: ST2000LM015-2E8174
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SDM1
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat May 30 09:27:23 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 333) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 067 064 006 - 4545798
|
||||
3 Spin_Up_Time PO---- 099 098 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1493
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 077 060 045 - 47280443
|
||||
9 Power_On_Hours -O--CK 080 080 000 - 17880 (246 111 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 126
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 071 046 040 - 29 (Min/Max 27/33)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 7
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 43
|
||||
193 Load_Cycle_Count -O--CK 099 099 000 - 2894
|
||||
194 Temperature_Celsius -O---K 029 054 000 - 29 (0 16 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 10404 (100 184 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 20505973060
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 16636213166
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa8 GPL,SL VS 136 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 8920 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc2 GPL,SL VS 240 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xc9 GPL,SL VS 1 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 14734 -
|
||||
# 2 Short offline Completed without error 00% 1 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/33 Celsius
|
||||
Lifetime Min/Max Temperature: 16/54 Celsius
|
||||
Specified Max Operating Temperature: 39 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 30 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (30)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 126 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 17880 --- Power-on Hours
|
||||
0x01 0x018 6 20505973060 --- Logical Sectors Written
|
||||
0x01 0x020 6 72947789 --- Number of Write Commands
|
||||
0x01 0x028 6 16636227431 --- Logical Sectors Read
|
||||
0x01 0x030 6 301014434 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 11894 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 9172 --- Head Flying Hours
|
||||
0x03 0x018 4 2894 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
124
HDD/Seagate/ST3120/ST3120023A/CFFF016768F1
Normal file
124
HDD/Seagate/ST3120/ST3120023A/CFFF016768F1
Normal file
@@ -0,0 +1,124 @@
|
||||
smartctl 6.6 2017-11-05 r4594 [FreeBSD 10.4-RELEASE-p13 amd64] (local build)
|
||||
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda ATA V
|
||||
Device Model: ST3120023A
|
||||
Serial Number: --
|
||||
Firmware Version: 3.31
|
||||
User Capacity: 120,034,123,776 bytes [120 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-6 T13/1410D revision 2
|
||||
Local Time is: Fri May 29 12:18:49 2020 JST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 128 (quiet), recommended: 128
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 426) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
No General Purpose Logging support.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 84) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 054 049 006 - 20033440
|
||||
3 Spin_Up_Time PO---- 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 88
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 088 060 030 - 740922613
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 125144
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1839
|
||||
194 Temperature_Celsius -O---K 050 061 000 - 50
|
||||
195 Hardware_ECC_Recovered -O-RC- 054 049 000 - 20033440
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
|
||||
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory not supported
|
||||
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x80-0x9f SL R/W 16 Host vendor specific log
|
||||
0xa0 SL VS 1 Device vendor specific log
|
||||
0xa1 SL VS 20 Device vendor specific log
|
||||
0xa2 SL VS 101 Device vendor specific log
|
||||
0xa8 SL VS 20 Device vendor specific log
|
||||
0xa9 SL VS 1 Device vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
||||
228
HDD/Seagate/ST3160/ST3160023A/57047AF8E587
Normal file
228
HDD/Seagate/ST3160/ST3160023A/57047AF8E587
Normal file
@@ -0,0 +1,228 @@
|
||||
smartctl 6.6 2017-11-05 r4594 [FreeBSD 11.2-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus
|
||||
Device Model: ST3160023A
|
||||
Serial Number: --
|
||||
Firmware Version: 3.01
|
||||
User Capacity: 160,040,803,840 bytes [160 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-6 T13/1410D revision 2
|
||||
Local Time is: Mon May 25 18:19:33 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 430) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
No General Purpose Logging support.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 111) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 065 054 006 - 0
|
||||
3 Spin_Up_Time PO---- 097 096 000 - 0
|
||||
4 Start_Stop_Count -O--CK 098 098 020 - 2054
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 084 060 030 - 321042941
|
||||
9 Power_On_Hours -O--CK 072 072 000 - 25344
|
||||
10 Spin_Retry_Count PO--C- 100 099 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 020 - 2655
|
||||
194 Temperature_Celsius -O---K 033 064 000 - 33
|
||||
195 Hardware_ECC_Recovered -O-RC- 065 054 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 081 000 - 4637
|
||||
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
|
||||
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory not supported
|
||||
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 SL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x20 SL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 SL R/O 1 Write stream error log
|
||||
0x22 SL R/O 1 Read stream error log
|
||||
0x23 SL R/O 1 Delayed sector log [OBS-8]
|
||||
0x80-0x9f SL R/W 16 Host vendor specific log
|
||||
0xa0 SL VS 1 Device vendor specific log
|
||||
0xa1 SL VS 20 Device vendor specific log
|
||||
0xa2 SL VS 101 Device vendor specific log
|
||||
0xa8 SL VS 20 Device vendor specific log
|
||||
0xa9 SL VS 1 Device vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log Version: 1
|
||||
ATA Error Count: 7128 (device log contains only the most recent five errors)
|
||||
CR = Command Register [HEX]
|
||||
FR = Features Register [HEX]
|
||||
SC = Sector Count Register [HEX]
|
||||
SN = Sector Number Register [HEX]
|
||||
CL = Cylinder Low Register [HEX]
|
||||
CH = Cylinder High Register [HEX]
|
||||
DH = Device/Head Register [HEX]
|
||||
DC = Device Command Register [HEX]
|
||||
ER = Error register [HEX]
|
||||
ST = Status register [HEX]
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 7128 occurred at disk power-on lifetime: 25235 hours (1051 days + 11 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
84 51 01 46 fb 38 e2 Error: ICRC, ABRT 1 sectors at LBA = 0x0238fb46 = 37288774
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
25 03 08 3f fb 38 e2 00 00:00:40.631 READ DMA EXT
|
||||
25 03 08 37 fb 38 e2 00 00:00:40.631 READ DMA EXT
|
||||
25 03 08 2f fb 38 e2 00 00:00:40.631 READ DMA EXT
|
||||
25 03 08 27 fb 38 e2 00 00:00:40.631 READ DMA EXT
|
||||
25 03 08 1f fb 38 e2 00 00:00:40.630 READ DMA EXT
|
||||
|
||||
Error 7127 occurred at disk power-on lifetime: 25128 hours (1047 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
84 51 01 1f d2 00 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x0000d21f = 53791
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
25 03 20 00 d2 00 e0 00 00:03:12.525 READ DMA EXT
|
||||
25 03 20 e0 d1 00 e0 00 00:03:12.524 READ DMA EXT
|
||||
25 03 20 c0 d1 00 e0 00 00:03:12.522 READ DMA EXT
|
||||
25 03 20 a0 d1 00 e0 00 00:03:12.521 READ DMA EXT
|
||||
25 03 20 80 d1 00 e0 00 00:03:12.519 READ DMA EXT
|
||||
|
||||
Error 7126 occurred at disk power-on lifetime: 25044 hours (1043 days + 12 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
84 51 01 5f 88 a0 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00a0885f = 10520671
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
25 03 80 e0 87 a0 e0 00 02:52:43.818 READ DMA EXT
|
||||
25 03 80 60 87 a0 e0 00 02:52:43.815 READ DMA EXT
|
||||
25 03 80 e0 86 a0 e0 00 02:52:43.813 READ DMA EXT
|
||||
25 03 80 60 86 a0 e0 00 02:52:43.810 READ DMA EXT
|
||||
25 03 80 e0 85 a0 e0 00 02:52:43.808 READ DMA EXT
|
||||
|
||||
Error 7125 occurred at disk power-on lifetime: 24336 hours (1014 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
84 51 01 a3 cf c6 e0 Error: ICRC, ABRT 1 sectors at LBA = 0x00c6cfa3 = 13029283
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
25 03 20 84 cf c6 e0 00 00:11:27.479 READ DMA EXT
|
||||
35 03 20 60 43 c6 e0 00 00:11:27.478 WRITE DMA EXT
|
||||
35 03 08 80 d0 c6 e0 00 00:11:27.476 WRITE DMA EXT
|
||||
25 03 20 80 cf c6 e0 00 00:11:27.476 READ DMA EXT
|
||||
35 03 20 60 43 c6 e0 00 00:11:27.475 WRITE DMA EXT
|
||||
|
||||
Error 7124 occurred at disk power-on lifetime: 24295 hours (1012 days + 7 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
84 51 01 df 9f 4a e0 Error: ICRC, ABRT 1 sectors at LBA = 0x004a9fdf = 4890591
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
25 03 80 60 9f 4a e0 00 00:59:42.541 READ DMA EXT
|
||||
25 03 80 e0 9e 4a e0 00 00:59:42.537 READ DMA EXT
|
||||
25 03 80 60 9e 4a e0 00 00:59:42.533 READ DMA EXT
|
||||
25 03 80 e0 9d 4a e0 00 00:59:42.530 READ DMA EXT
|
||||
25 03 80 60 9d 4a e0 00 00:59:42.526 READ DMA EXT
|
||||
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
||||
178
HDD/Seagate/ST3160/ST3160318AS/5E781043CFB0
Normal file
178
HDD/Seagate/ST3160/ST3160318AS/5E781043CFB0
Normal file
@@ -0,0 +1,178 @@
|
||||
smartctl 6.6 2017-11-05 r4594 [FreeBSD 10.4-RELEASE-p13 amd64] (local build)
|
||||
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.12
|
||||
Device Model: ST3160318AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: HP34
|
||||
User Capacity: 160,041,885,696 bytes [160 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Fri May 29 12:15:45 2020 JST
|
||||
|
||||
==> WARNING: A firmware update for this drive may be available,
|
||||
see the following Seagate web pages:
|
||||
http://knowledge.seagate.com/articles/en_US/FAQ/207931en
|
||||
http://knowledge.seagate.com/articles/en_US/FAQ/213891en
|
||||
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 617) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 35) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 109 099 006 - 20996419
|
||||
3 Spin_Up_Time PO---K 097 097 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 274
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-K 085 060 030 - 339997925
|
||||
9 Power_On_Hours -O--CK 038 038 000 - 54967
|
||||
10 Spin_Retry_Count PO--CK 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 137
|
||||
180 Unknown_HDD_Attribute PO-R-K 100 100 000 - 4294967295
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 4295032833
|
||||
189 High_Fly_Writes -O-RCK 099 099 000 - 1
|
||||
190 Airflow_Temperature_Cel -O---K 067 057 045 - 33 (Min/Max 21/35)
|
||||
194 Temperature_Celsius -O---K 033 043 000 - 33 (0 12 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RCK 054 032 000 - 20996419
|
||||
196 Reallocated_Event_Count -O--CK 100 100 036 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2928 Device vendor specific log
|
||||
0xbd GPL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 6 -
|
||||
# 2 Short offline Completed without error 00% 6 -
|
||||
# 3 Extended offline Interrupted (host reset) 70% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
SCT Support Level: 1
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/35 Celsius
|
||||
Lifetime Min/Max Temperature: 12/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (6)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
184
HDD/Seagate/ST320/ST320VT000-1BS14C/A20C22C4AF6F
Normal file
184
HDD/Seagate/ST320/ST320VT000-1BS14C/A20C22C4AF6F
Normal file
@@ -0,0 +1,184 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: ST320VT000-1BS14C
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001SDC1
|
||||
User Capacity: 320,072,933,376 bytes [320 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat May 23 06:22:17 2020 WIB
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 192 (intermediate level without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 76) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x10b1) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 116 099 006 - 102680952
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 086 086 020 - 14712
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 087 060 030 - 557212808
|
||||
9 Power_On_Hours -O--CK 071 071 000 - 26011
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 094 094 020 - 6400
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 098 000 - 2
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 059 054 045 - 41 (Min/Max 29/41)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 39
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 1028
|
||||
193 Load_Cycle_Count -O--CK 089 089 000 - 22941
|
||||
194 Temperature_Celsius -O---K 041 046 000 - 41 (0 16 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 65 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2864 Device vendor specific log
|
||||
0xbd-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 25396 -
|
||||
# 2 Short offline Completed without error 00% 25378 -
|
||||
# 3 Short offline Completed without error 00% 25344 -
|
||||
# 4 Short offline Completed without error 00% 25310 -
|
||||
# 5 Short offline Completed without error 00% 25277 -
|
||||
# 6 Short offline Completed without error 00% 25247 -
|
||||
# 7 Short offline Completed without error 00% 25216 -
|
||||
# 8 Short offline Completed without error 00% 25186 -
|
||||
# 9 Short offline Completed without error 00% 25151 -
|
||||
#10 Short offline Completed without error 00% 25121 -
|
||||
#11 Short offline Completed without error 00% 25091 -
|
||||
#12 Short offline Completed without error 00% 25057 -
|
||||
#13 Short offline Completed without error 00% 25026 -
|
||||
#14 Short offline Completed without error 00% 24996 -
|
||||
#15 Short offline Completed without error 00% 24996 -
|
||||
#16 Short offline Completed without error 00% 24966 -
|
||||
#17 Short offline Completed without error 00% 24936 -
|
||||
#18 Short offline Completed without error 00% 24905 -
|
||||
#19 Short offline Completed without error 00% 24876 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/41 Celsius
|
||||
Lifetime Min/Max Temperature: 16/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 300 minutes
|
||||
Min/Max recommended Temperature: 1/61 Celsius
|
||||
Min/Max Temperature Limit: 2/60 Celsius
|
||||
Temperature History Size (Index): 432 (228)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
189
HDD/Seagate/ST3250/ST3250312AS/5C0F642B66FF
Normal file
189
HDD/Seagate/ST3250/ST3250312AS/5C0F642B66FF
Normal file
@@ -0,0 +1,189 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.12
|
||||
Device Model: ST3250312AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: JC45
|
||||
User Capacity: 250,059,350,016 bytes [250 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri May 22 15:58:36 2020 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 592) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 39) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 108 099 006 - 15084326
|
||||
3 Spin_Up_Time PO---- 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 098 098 020 - 2442
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 084 060 030 - 256005867
|
||||
9 Power_On_Hours -O--CK 072 072 000 - 24947
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1384
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 8590065672
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 076 051 045 - 24 (Min/Max 23/35)
|
||||
194 Temperature_Celsius -O---K 024 049 000 - 24 (0 17 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 034 024 000 - 15084326
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 26060 (140 177 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 3684481479
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 774679952
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2928 Device vendor specific log
|
||||
0xbd GPL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 11778 -
|
||||
# 2 Short offline Completed without error 00% 11754 -
|
||||
# 3 Short offline Completed without error 00% 11730 -
|
||||
# 4 Short offline Completed without error 00% 11706 -
|
||||
# 5 Short offline Completed without error 00% 11682 -
|
||||
# 6 Short offline Completed without error 00% 11658 -
|
||||
# 7 Short offline Completed without error 00% 11634 -
|
||||
# 8 Short offline Completed without error 00% 11610 -
|
||||
# 9 Short offline Completed without error 00% 11586 -
|
||||
#10 Short offline Completed without error 00% 11562 -
|
||||
#11 Short offline Completed without error 00% 11538 -
|
||||
#12 Short offline Completed without error 00% 11514 -
|
||||
#13 Short offline Completed without error 00% 11490 -
|
||||
#14 Short offline Completed without error 00% 11466 -
|
||||
#15 Short offline Completed without error 00% 11442 -
|
||||
#16 Short offline Completed without error 00% 11418 -
|
||||
#17 Short offline Completed without error 00% 11394 -
|
||||
#18 Short offline Completed without error 00% 11370 -
|
||||
#19 Short offline Completed without error 00% 11346 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 24 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/36 Celsius
|
||||
Lifetime Min/Max Temperature: 17/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (5)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
108
HDD/Seagate/ST3250/ST3250318AS/39EAC67B78F6
Normal file
108
HDD/Seagate/ST3250/ST3250318AS/39EAC67B78F6
Normal file
@@ -0,0 +1,108 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [i386-unknown-openbsd6.7] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.12
|
||||
Device Model: ST3250318AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC49
|
||||
User Capacity: 250,059,350,016 bytes [250 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Wed May 27 12:43:25 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 600) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 41) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x000f 119 099 006 Pre-fail Always - 203977650
|
||||
3 Spin_Up_Time 0x0003 097 097 000 Pre-fail Always - 0
|
||||
4 Start_Stop_Count 0x0032 099 099 020 Old_age Always - 1653
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
|
||||
7 Seek_Error_Rate 0x000f 083 060 030 Pre-fail Always - 230779772
|
||||
9 Power_On_Hours 0x0032 056 056 000 Old_age Always - 39268
|
||||
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
|
||||
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 825
|
||||
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
|
||||
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
|
||||
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
|
||||
188 Command_Timeout 0x0032 100 099 000 Old_age Always - 15
|
||||
189 High_Fly_Writes 0x003a 099 099 000 Old_age Always - 1
|
||||
190 Airflow_Temperature_Cel 0x0022 057 052 045 Old_age Always - 43 (Min/Max 23/47)
|
||||
194 Temperature_Celsius 0x0022 043 048 000 Old_age Always - 43 (0 19 0 0 0)
|
||||
195 Hardware_ECC_Recovered 0x001a 030 023 000 Old_age Always - 203977650
|
||||
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
|
||||
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
|
||||
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
|
||||
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 41430 (131 161 0)
|
||||
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 1408244340
|
||||
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 211551134
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 36369 -
|
||||
# 2 Extended offline Completed without error 00% 34385 -
|
||||
# 3 Extended offline Completed without error 00% 33164 -
|
||||
# 4 Extended offline Completed without error 00% 31652 -
|
||||
# 5 Extended offline Completed without error 00% 29114 -
|
||||
# 6 Extended offline Completed without error 00% 27805 -
|
||||
# 7 Short offline Completed without error 00% 27250 -
|
||||
# 8 Extended offline Completed without error 00% 23303 -
|
||||
# 9 Extended offline Completed without error 00% 13492 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
131
HDD/Seagate/ST3320/ST3320620A/4CCB5639939A
Normal file
131
HDD/Seagate/ST3320/ST3320620A/4CCB5639939A
Normal file
@@ -0,0 +1,131 @@
|
||||
smartctl 6.6 2017-11-05 r4594 [FreeBSD 10.3-RELEASE-p11 i386] (local build)
|
||||
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.10
|
||||
Device Model: ST3320620A
|
||||
Serial Number: --
|
||||
Firmware Version: 3.AAE
|
||||
User Capacity: 320,072,933,376 bytes [320 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Fri May 29 12:22:15 2020 JST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 430) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 115) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 106 085 006 - 163078992
|
||||
3 Spin_Up_Time PO---- 095 095 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 19
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 041 040 030 - 35231726283838
|
||||
9 Power_On_Hours -O--CK 048 048 000 - 45928
|
||||
10 Spin_Retry_Count PO--C- 100 069 097 Past 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 20
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 059 051 045 - 41 (Min/Max 25/49)
|
||||
194 Temperature_Celsius -O---K 041 049 000 - 41 (0 23 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 062 046 000 - 117723264
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
|
||||
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL,SL VS 1 Device vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL,SL VS 101 Device vendor specific log
|
||||
0xa8 GPL,SL VS 20 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
0xff GPL - 23552 Reserved
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
||||
141
HDD/Seagate/ST3320/ST3320620AS/D89C07C13F33
Normal file
141
HDD/Seagate/ST3320/ST3320620AS/D89C07C13F33
Normal file
@@ -0,0 +1,141 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.10
|
||||
Device Model: ST3320620AS
|
||||
Serial Number: --
|
||||
Firmware Version: 3.AAE
|
||||
User Capacity: 320,072,933,376 bytes [320 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Mon May 25 14:02:07 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 430) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 115) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 115 099 006 - 98776671
|
||||
3 Spin_Up_Time PO---- 096 096 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1470
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 069 060 030 - 271119912017
|
||||
9 Power_On_Hours -O--CK 053 053 000 - 41697
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1572
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 074 048 045 - 26 (Min/Max 18/28)
|
||||
194 Temperature_Celsius -O---K 026 052 000 - 26 (0 15 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 061 056 000 - 196309809
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
|
||||
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL,SL VS 1 Device vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL,SL VS 101 Device vendor specific log
|
||||
0xa8 GPL,SL VS 20 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
0xff GPL - 23040 Reserved
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
172
HDD/Seagate/ST3500/ST3500413AS/118C4D6098A8
Normal file
172
HDD/Seagate/ST3500/ST3500413AS/118C4D6098A8
Normal file
@@ -0,0 +1,172 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.12
|
||||
Device Model: ST3500413AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: JC47
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat May 23 15:03:39 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 208 (intermediate), recommended: 208
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 600) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 86) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 119 099 006 - 221033871
|
||||
3 Spin_Up_Time PO---- 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 67
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 090 060 030 - 974456483
|
||||
9 Power_On_Hours -O--CK 049 049 000 - 45260
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 67
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 1
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 062 054 045 - 38 (Min/Max 23/40)
|
||||
194 Temperature_Celsius -O---K 038 046 000 - 38 (0 14 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 026 017 000 - 221033871
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 45406 (188 134 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 2767225473
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 3452498518
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2928 Device vendor specific log
|
||||
0xbd GPL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/40 Celsius
|
||||
Lifetime Min/Max Temperature: 14/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (65)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
170
HDD/Seagate/ST3500/ST3500413AS/FBC60C19490A
Normal file
170
HDD/Seagate/ST3500/ST3500413AS/FBC60C19490A
Normal file
@@ -0,0 +1,170 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.12
|
||||
Device Model: ST3500413AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: JC47
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat May 23 15:03:40 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 208 (intermediate), recommended: 208
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 600) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 82) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 117 099 006 - 130214092
|
||||
3 Spin_Up_Time PO---- 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 67
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 089 060 030 - 909042221
|
||||
9 Power_On_Hours -O--CK 049 049 000 - 45258
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 67
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 1
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 063 056 045 - 37 (Min/Max 24/40)
|
||||
194 Temperature_Celsius -O---K 037 044 000 - 37 (0 15 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 021 015 000 - 130214092
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 45389 (234 52 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 93007281
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1598560638
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2928 Device vendor specific log
|
||||
0xbd GPL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/40 Celsius
|
||||
Lifetime Min/Max Temperature: 15/45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (58)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
172
HDD/Seagate/ST3500/ST3500514NS/17190995F3F2
Normal file
172
HDD/Seagate/ST3500/ST3500514NS/17190995F3F2
Normal file
@@ -0,0 +1,172 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Constellation ES (SATA)
|
||||
Device Model: ST3500514NS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SN11
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon May 25 14:02:01 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 609) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 87) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x10bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 082 063 044 - 192937428
|
||||
3 Spin_Up_Time PO---- 100 100 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 72
|
||||
5 Reallocated_Sector_Ct PO--CK 098 098 036 - 103
|
||||
7 Seek_Error_Rate POSR-- 089 060 030 - 886873865
|
||||
9 Power_On_Hours -O--CK 095 011 000 - 4938
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 94
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 091 000 - 120
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 074 052 045 - 26 (Min/Max 24/40)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 50
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 94
|
||||
194 Temperature_Celsius -O---K 026 048 000 - 26 (0 12 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 025 017 000 - 192937428
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x12 GPL,SL R/O 1 SATA NCQ Non-Data log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2928 Device vendor specific log
|
||||
0xb6 GPL VS 1918 Device vendor specific log
|
||||
0xbd GPL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/40 Celsius
|
||||
Lifetime Min/Max Temperature: 12/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/110489
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (64)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 100 (10.0 seconds)
|
||||
Write: 100 (10.0 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 55 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
160
HDD/Seagate/ST3500/ST3500630NS/18474964BA39
Normal file
160
HDD/Seagate/ST3500/ST3500630NS/18474964BA39
Normal file
@@ -0,0 +1,160 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda ES
|
||||
Device Model: ST3500630NS
|
||||
Serial Number: --
|
||||
Firmware Version: 3.AEG
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Mon May 25 14:02:01 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Unexpected SCT status 0xffff (action_code=4, function_code=2)
|
||||
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 430) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 163) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 114 092 006 - 71582601
|
||||
3 Spin_Up_Time PO---- 096 093 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 166
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 088 060 030 - 700759197
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 96136
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 204
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 066 028 045 Past 34 (Min/Max 31/46 #11235)
|
||||
194 Temperature_Celsius -O---K 034 072 000 - 34 (0 12 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 057 051 000 - 126809258
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
|
||||
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL,SL VS 1 Device vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL,SL VS 101 Device vendor specific log
|
||||
0xa8 GPL,SL VS 20 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
0xff GPL - 23040 Reserved
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 521 (0x0209)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: --/46 Celsius
|
||||
Lifetime Min/Max Temperature: --/72 Celsius
|
||||
|
||||
Another SCT command is executing, abort Read Data Table
|
||||
(SCT ext_status_code 0xffff, action_code=4, function_code=2)
|
||||
Read SCT Temperature History failed
|
||||
|
||||
Another SCT command is executing, abort Error Recovery Control
|
||||
(SCT ext_status_code 0xffff, action_code=4, function_code=2)
|
||||
SCT (Get) Error Recovery Control command failed
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 77 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
289
HDD/Seagate/ST3808/ST380811AS/3EDE73A1A00D
Normal file
289
HDD/Seagate/ST3808/ST380811AS/3EDE73A1A00D
Normal file
@@ -0,0 +1,289 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.9
|
||||
Device Model: ST380811AS
|
||||
Serial Number: --
|
||||
Firmware Version: 3.AAE
|
||||
User Capacity: 80,025,280,000 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Mon May 25 17:47:22 2020 YEKT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 430) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 27) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 093 087 006 - 0
|
||||
3 Spin_Up_Time PO---- 096 095 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1353
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 087 060 030 - 580788136
|
||||
9 Power_On_Hours -O--CK 090 090 000 - 9203
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1375
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 061 049 045 - 39 (Min/Max 38/41)
|
||||
194 Temperature_Celsius -O---K 039 051 000 - 39 (0 8 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 071 045 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
|
||||
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL,SL VS 1 Device vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL,SL VS 101 Device vendor specific log
|
||||
0xa8 GPL,SL VS 20 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
0xff GPL - 23040 Reserved
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
Device Error Count: 542 (device log contains only the most recent 20 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 542 [1] occurred at disk power-on lifetime: 9197 hours (383 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 01 01 00 00 05 df 00 df e9 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
37 00 00 01 01 00 09 f0 00 50 6e e9 00 00:30:11.805 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 00 00 00 09 f0 00 50 6e e0 00 00:30:11.588 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
37 00 00 00 00 00 09 f0 00 50 6e e9 00 00:30:11.525 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 01 01 00 09 f0 00 50 6e e0 00 00:30:09.444 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
37 00 00 01 01 00 09 f0 00 50 6e e9 00 00:30:09.385 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
|
||||
Error 541 [0] occurred at disk power-on lifetime: 9197 hours (383 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 01 01 00 00 05 df 00 df e9 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
37 00 00 01 01 00 09 f0 00 50 6e e9 00 00:30:06.738 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 00 00 00 09 f0 00 50 6e e0 00 00:30:06.738 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
37 00 00 00 00 00 09 f0 00 50 6e e9 00 00:30:06.738 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 00 01 00 09 f8 00 50 af e0 00 00:30:09.444 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
29 00 00 00 01 00 09 f8 00 50 af e0 00 00:30:09.385 READ MULTIPLE EXT
|
||||
|
||||
Error 540 [19] occurred at disk power-on lifetime: 9091 hours (378 days + 19 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 01 01 00 00 98 4f 13 4f e9 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
37 00 00 01 01 00 09 f0 00 50 6e e9 00 02:54:01.060 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 00 00 00 09 f0 00 50 6e e0 00 02:54:00.999 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
37 00 00 00 00 00 09 f0 00 50 6e e9 00 02:54:00.999 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 01 01 00 09 f0 00 50 6e e0 00 02:54:06.117 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
37 00 00 01 01 00 09 f0 00 50 6e e9 00 02:54:06.058 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
|
||||
Error 539 [18] occurred at disk power-on lifetime: 9091 hours (378 days + 19 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 01 01 00 00 98 4f 13 4f e9 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
37 00 00 01 01 00 09 f0 00 50 6e e9 00 02:54:01.060 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 00 00 00 09 f0 00 50 6e e0 00 02:54:00.999 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
37 00 00 00 00 00 09 f0 00 50 6e e9 00 02:54:00.999 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 00 01 00 09 f8 00 50 af e0 00 02:54:00.999 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
29 00 00 00 01 00 09 f8 00 50 af e0 00 02:54:00.999 READ MULTIPLE EXT
|
||||
|
||||
Error 538 [17] occurred at disk power-on lifetime: 9197 hours (383 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 01 01 00 00 05 df 00 df e9 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
37 00 00 01 01 00 09 f0 00 50 6e e9 00 00:30:11.805 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 00 00 00 09 f0 00 50 6e e0 00 00:30:11.588 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
37 00 00 00 00 00 09 f0 00 50 6e e9 00 00:30:11.525 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 01 01 00 09 f0 00 50 6e e0 00 00:30:09.444 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
37 00 00 01 01 00 09 f0 00 50 6e e9 00 00:30:09.385 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
|
||||
Error 537 [16] occurred at disk power-on lifetime: 9197 hours (383 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 01 01 00 00 05 df 00 df e9 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
37 00 00 01 01 00 09 f0 00 50 6e e9 00 00:30:06.738 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 00 00 00 09 f0 00 50 6e e0 00 00:30:06.738 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
37 00 00 00 00 00 09 f0 00 50 6e e9 00 00:30:06.738 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 00 01 00 09 f8 00 50 af e0 00 00:30:09.444 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
29 00 00 00 01 00 09 f8 00 50 af e0 00 00:30:09.385 READ MULTIPLE EXT
|
||||
|
||||
Error 536 [15] occurred at disk power-on lifetime: 9091 hours (378 days + 19 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 01 01 00 00 98 4f 13 4f e9 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
37 00 00 01 01 00 09 f0 00 50 6e e9 00 02:54:01.060 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 00 00 00 09 f0 00 50 6e e0 00 02:54:00.999 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
37 00 00 00 00 00 09 f0 00 50 6e e9 00 02:54:00.999 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 01 01 00 09 f0 00 50 6e e0 00 02:54:06.117 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
37 00 00 01 01 00 09 f0 00 50 6e e9 00 02:54:06.058 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
|
||||
Error 535 [14] occurred at disk power-on lifetime: 9091 hours (378 days + 19 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 01 01 00 00 98 4f 13 4f e9 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
37 00 00 01 01 00 09 f0 00 50 6e e9 00 02:54:01.060 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 00 00 00 09 f0 00 50 6e e0 00 02:54:00.999 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
37 00 00 00 00 00 09 f0 00 50 6e e9 00 02:54:00.999 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
27 00 00 00 01 00 09 f8 00 50 af e0 00 02:54:00.999 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
29 00 00 00 01 00 09 f8 00 50 af e0 00 02:54:00.999 READ MULTIPLE EXT
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 62 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
210
HDD/Seagate/ST4000/ST4000DM000-1F2168/42216A2FC4ED
Normal file
210
HDD/Seagate/ST4000/ST4000DM000-1F2168/42216A2FC4ED
Normal file
@@ -0,0 +1,210 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Desktop HDD.15
|
||||
Device Model: ST4000DM000-1F2168
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC54
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu May 28 09:20:54 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 97) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 490) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 120 099 006 - 235172104
|
||||
3 Spin_Up_Time PO---- 091 091 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 16
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 080 060 030 - 109563833
|
||||
9 Power_On_Hours -O--CK 057 057 000 - 38244
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 16
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0 0 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 071 056 045 - 29 (Min/Max 18/39)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 060 060 000 - 80250
|
||||
194 Temperature_Celsius -O---K 029 044 000 - 29 (0 11 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 36947h+02m+16.444s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 8914296730
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 659145686724
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 1223 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 1223 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 38140 -
|
||||
# 2 Extended offline Completed without error 00% 38012 -
|
||||
# 3 Short offline Completed without error 00% 37977 -
|
||||
# 4 Short offline Completed without error 00% 37809 -
|
||||
# 5 Short offline Completed without error 00% 37641 -
|
||||
# 6 Short offline Completed without error 00% 37473 -
|
||||
# 7 Short offline Completed without error 00% 37305 -
|
||||
# 8 Extended offline Completed without error 00% 37292 -
|
||||
# 9 Short offline Completed without error 00% 37137 -
|
||||
#10 Short offline Completed without error 00% 36969 -
|
||||
#11 Short offline Completed without error 00% 36801 -
|
||||
#12 Short offline Completed without error 00% 36633 -
|
||||
#13 Extended offline Completed without error 00% 36548 -
|
||||
#14 Short offline Completed without error 00% 36465 -
|
||||
#15 Short offline Completed without error 00% 36298 -
|
||||
#16 Short offline Completed without error 00% 36136 -
|
||||
#17 Short offline Completed without error 00% 35968 -
|
||||
#18 Extended offline Completed without error 00% 35858 -
|
||||
#19 Short offline Completed without error 00% 35800 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 18/39 Celsius
|
||||
Lifetime Min/Max Temperature: 11/44 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 16 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 38244 --- Power-on Hours
|
||||
0x01 0x018 6 8916794082 --- Logical Sectors Written
|
||||
0x01 0x020 6 90112967 --- Number of Write Commands
|
||||
0x01 0x028 6 204268653713 --- Logical Sectors Read
|
||||
0x01 0x030 6 1379890370 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 38244 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 126 --- Head Flying Hours
|
||||
0x03 0x018 4 80250 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
212
HDD/Seagate/ST4000/ST4000DM000-1F2168/8071CC86F9BC
Normal file
212
HDD/Seagate/ST4000/ST4000DM000-1F2168/8071CC86F9BC
Normal file
@@ -0,0 +1,212 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Desktop HDD.15
|
||||
Device Model: ST4000DM000-1F2168
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC54
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu May 28 09:25:35 2020 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 107) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 501) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 120 099 006 - 237602104
|
||||
3 Spin_Up_Time PO---- 091 091 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1439
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 077 060 030 - 51764414
|
||||
9 Power_On_Hours -O--CK 084 084 000 - 14500
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1439
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0 0 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 076 060 045 - 24 (Min/Max 22/24)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 241914
|
||||
194 Temperature_Celsius -O---K 024 040 000 - 24 (0 15 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 4206h+15m+51.088s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 3263056698
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1098048055223
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 1223 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 1223 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 14484 -
|
||||
# 2 Short offline Completed without error 00% 14456 -
|
||||
# 3 Extended offline Completed without error 00% 14455 -
|
||||
# 4 Extended offline Completed without error 00% 14427 -
|
||||
# 5 Extended offline Completed without error 00% 14401 -
|
||||
# 6 Extended offline Completed without error 00% 14376 -
|
||||
# 7 Extended offline Completed without error 00% 14348 -
|
||||
# 8 Short offline Completed without error 00% 14323 -
|
||||
# 9 Extended offline Completed without error 00% 14321 -
|
||||
#10 Extended offline Completed without error 00% 14295 -
|
||||
#11 Extended offline Completed without error 00% 14269 -
|
||||
#12 Extended offline Completed without error 00% 14241 -
|
||||
#13 Extended offline Completed without error 00% 14217 -
|
||||
#14 Extended offline Completed without error 00% 14177 -
|
||||
#15 Extended offline Completed without error 00% 14138 -
|
||||
#16 Extended offline Completed without error 00% 14104 -
|
||||
#17 Extended offline Completed without error 00% 14077 -
|
||||
#18 Extended offline Completed without error 00% 14047 -
|
||||
#19 Short offline Completed without error 00% 14022 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 23 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/23 Celsius
|
||||
Lifetime Min/Max Temperature: 15/40 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 1439 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 14500 --- Power-on Hours
|
||||
0x01 0x018 6 2994095042 --- Logical Sectors Written
|
||||
0x01 0x020 6 52168027 --- Number of Write Commands
|
||||
0x01 0x028 6 99494725427 --- Logical Sectors Read
|
||||
0x01 0x030 6 517637536 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 14496 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 80 --- Head Flying Hours
|
||||
0x03 0x018 4 241914 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
181
HDD/Seagate/ST4000/ST4000LM016-1N2170/B9475BCCA4D8
Normal file
181
HDD/Seagate/ST4000/ST4000LM016-1N2170/B9475BCCA4D8
Normal file
@@ -0,0 +1,181 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Laptop HDD
|
||||
Device Model: ST4000LM016-1N2170
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0003
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed May 27 00:19:37 2020 +07
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 690) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 123 099 006 - 537001052
|
||||
3 Spin_Up_Time PO---- 097 096 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 869
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 062 060 030 - 60158705860
|
||||
9 Power_On_Hours -O--CK 069 069 000 - 27520 (125 153 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 689
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 084 000 - 65
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 054 039 045 Past 46 (Min/Max 38/46 #266)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 269
|
||||
193 Load_Cycle_Count -O--CK 081 081 000 - 39406
|
||||
194 Temperature_Celsius -O---K 046 061 000 - 46 (0 22 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 2267 (23 27 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 12650901671
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 5636182377
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5180 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc2 GPL,SL VS 50 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xc7 GPL,SL VS 1 Device vendor specific log
|
||||
0xd3 GPL VS 16385 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/46 Celsius
|
||||
Lifetime Min/Max Temperature: 22/61 Celsius
|
||||
Specified Max Operating Temperature: 45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 30 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (3)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
177
HDD/Seagate/ST4000/ST4000NM0033-9ZM170/04EBE94D138B
Normal file
177
HDD/Seagate/ST4000/ST4000NM0033-9ZM170/04EBE94D138B
Normal file
@@ -0,0 +1,177 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 13.0-CURRENT amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Constellation ES.3
|
||||
Device Model: ST4000NM0033-9ZM170
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 15:05:48 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 592) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 509) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 078 063 044 - 64957635
|
||||
3 Spin_Up_Time PO---- 092 091 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 239
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 095 060 030 - 3583213312
|
||||
9 Power_On_Hours -O--CK 038 038 000 - 54745
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 247
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 060 048 045 - 40 (Min/Max 38/52)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 176
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 242
|
||||
194 Temperature_Celsius -O---K 040 052 000 - 40 (0 21 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 060 012 000 - 64957635
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL,SL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbd GPL VS 512 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc2 GPL,SL VS 50 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 40 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/52 Celsius
|
||||
Lifetime Min/Max Temperature: 21/52 Celsius
|
||||
Under/Over Temperature Limit Count: 0/2996
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (109)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 100 (10.0 seconds)
|
||||
Write: 100 (10.0 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 30 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
177
HDD/Seagate/ST4000/ST4000NM0033-9ZM170/3E107E0D99C9
Normal file
177
HDD/Seagate/ST4000/ST4000NM0033-9ZM170/3E107E0D99C9
Normal file
@@ -0,0 +1,177 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 13.0-CURRENT amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Constellation ES.3
|
||||
Device Model: ST4000NM0033-9ZM170
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 15:05:49 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 600) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 517) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 083 063 044 - 224185446
|
||||
3 Spin_Up_Time PO---- 092 091 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 242
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 095 060 030 - 3698417078
|
||||
9 Power_On_Hours -O--CK 038 038 000 - 54746
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 251
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 093 093 000 - 7
|
||||
190 Airflow_Temperature_Cel -O---K 061 049 045 - 39 (Min/Max 37/51)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 181
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 247
|
||||
194 Temperature_Celsius -O---K 039 051 000 - 39 (0 21 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 047 011 000 - 224185446
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL,SL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbd GPL VS 512 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc2 GPL,SL VS 50 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 37/50 Celsius
|
||||
Lifetime Min/Max Temperature: 21/51 Celsius
|
||||
Under/Over Temperature Limit Count: 0/2995
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (112)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 100 (10.0 seconds)
|
||||
Write: 100 (10.0 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 30 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
179
HDD/Seagate/ST4000/ST4000NM0033-9ZM170/AF5573129323
Normal file
179
HDD/Seagate/ST4000/ST4000NM0033-9ZM170/AF5573129323
Normal file
@@ -0,0 +1,179 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 13.0-CURRENT amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Constellation ES.3
|
||||
Device Model: ST4000NM0033-9ZM170
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SN04
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 15:05:48 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 584) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 479) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 080 063 044 - 102138713
|
||||
3 Spin_Up_Time PO---- 092 091 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 74
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 088 060 030 - 747126935
|
||||
9 Power_On_Hours -O--CK 062 062 000 - 33655
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 74
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 1
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 062 050 045 - 38 (Min/Max 36/50)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 30
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 1448
|
||||
194 Temperature_Celsius -O---K 038 050 000 - 38 (0 21 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 061 016 000 - 102138713
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL,SL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbd GPL VS 512 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc2 GPL,SL VS 50 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xd1 GPL,SL VS 8 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/50 Celsius
|
||||
Lifetime Min/Max Temperature: 21/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/2988
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (80)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 100 (10.0 seconds)
|
||||
Write: 100 (10.0 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 30 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
223
HDD/Seagate/ST4000/ST4000VN008-2DR166/53E85D414D7D
Normal file
223
HDD/Seagate/ST4000/ST4000VN008-2DR166/53E85D414D7D
Normal file
@@ -0,0 +1,223 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate IronWolf
|
||||
Device Model: ST4000VN008-2DR166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC60
|
||||
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5980 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 18:20:45 2020 +06
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 581) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 636) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 084 064 044 - 241268427
|
||||
3 Spin_Up_Time PO---- 093 093 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1193
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 090 060 045 - 954752179
|
||||
9 Power_On_Hours -O--CK 094 094 000 - 5748 (231 84 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1193
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 091 000 - 81
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 065 061 040 - 35 (Min/Max 24/35)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 1
|
||||
193 Load_Cycle_Count -O--CK 099 099 000 - 3885
|
||||
194 Temperature_Celsius -O---K 035 040 000 - 35 (0 19 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 76
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 5249 (10 32 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 17339557438
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 292306829410
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x15 GPL R/W 1 Rebuild Assist log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xd1 GPL VS 136 Device vendor specific log
|
||||
0xd2 GPL VS 10000 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 1 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/35 Celsius
|
||||
Lifetime Min/Max Temperature: 19/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/1
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (45)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1193 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 5748 --- Power-on Hours
|
||||
0x01 0x018 6 17339617918 --- Logical Sectors Written
|
||||
0x01 0x020 6 106276973 --- Number of Write Commands
|
||||
0x01 0x028 6 292319462754 --- Logical Sectors Read
|
||||
0x01 0x030 6 1325154474 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 12595260 N-- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 12590444 N-- Head Flying Hours
|
||||
0x03 0x018 4 3885 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 2 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 81 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 35 --- Current Temperature
|
||||
0x05 0x010 1 34 --- Average Short Term Temperature
|
||||
0x05 0x018 1 33 --- Average Long Term Temperature
|
||||
0x05 0x020 1 39 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 36 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 34 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 30 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 3559 --- Number of Hardware Resets
|
||||
0x06 0x010 4 580 --- Number of ASR Events
|
||||
0x06 0x018 4 76 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
204
HDD/Seagate/ST500/ST500LM012 HN-M500MBB/56D35D5B08B4
Normal file
204
HDD/Seagate/ST500/ST500LM012 HN-M500MBB/56D35D5B08B4
Normal file
@@ -0,0 +1,204 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Samsung SpinPoint M8 (AF)
|
||||
Device Model: ST500LM012 HN-M500MBB
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0004cf ...
|
||||
Firmware Version: 2BA30001
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon Jun 1 13:20:28 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 39) The self-test routine was interrupted
|
||||
by the host with a hard or soft reset.
|
||||
Total time to complete Offline
|
||||
data collection: ( 6840) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 114) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 0
|
||||
2 Throughput_Performance -OS--K 056 056 000 - 6174
|
||||
3 Spin_Up_Time PO---K 095 095 025 - 1743
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 424
|
||||
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
|
||||
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
|
||||
8 Seek_Time_Performance --S--K 252 252 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 5133
|
||||
10 Spin_Retry_Count -O--CK 252 252 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 72
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 370
|
||||
191 G-Sense_Error_Rate -O---K 100 100 000 - 8
|
||||
192 Power-Off_Retract_Count -O---K 100 100 000 - 14
|
||||
194 Temperature_Celsius -O---- 062 057 000 - 38 (Min/Max 17/48)
|
||||
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 252 252 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 252 252 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 15326
|
||||
223 Load_Retry_Count -O--CK 100 100 000 - 72
|
||||
225 Load_Cycle_Count -O--CK 040 040 000 - 608535
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 2 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xc0-0xdf GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (2 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Interrupted (host reset) 70% 5079 -
|
||||
# 2 Short offline Completed without error 00% 4193 -
|
||||
# 3 Extended offline Completed without error 00% 4189 -
|
||||
# 4 Extended offline Interrupted (host reset) 90% 3471 -
|
||||
# 5 Extended offline Completed without error 00% 2829 -
|
||||
# 6 Extended offline Completed without error 00% 2476 -
|
||||
# 7 Extended offline Completed without error 00% 2005 -
|
||||
# 8 Extended offline Aborted by host 90% 1993 -
|
||||
# 9 Extended offline Completed without error 00% 1390 -
|
||||
#10 Extended offline Interrupted (host reset) 90% 1152 -
|
||||
#11 Extended offline Completed without error 00% 973 -
|
||||
#12 Extended offline Interrupted (host reset) 50% 81 -
|
||||
#13 Short offline Completed without error 00% 58 -
|
||||
#14 Short offline Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Interrupted [70% left] (0-65535)
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/38 Celsius
|
||||
Lifetime Min/Max Temperature: 12/47 Celsius
|
||||
Specified Max Operating Temperature: 80 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 5 minutes
|
||||
Temperature Logging Interval: 5 minutes
|
||||
Min/Max recommended Temperature: -5/80 Celsius
|
||||
Min/Max Temperature Limit: -10/85 Celsius
|
||||
Temperature History Size (Index): 128 (100)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0002 4 0 R_ERR response for data FIS
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 4 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
0x8e00 4 0 Vendor specific
|
||||
0x8e01 4 0 Vendor specific
|
||||
0x8e02 4 0 Vendor specific
|
||||
0x8e03 4 0 Vendor specific
|
||||
0x8e04 4 0 Vendor specific
|
||||
0x8e05 4 0 Vendor specific
|
||||
0x8e06 4 0 Vendor specific
|
||||
0x8e07 4 0 Vendor specific
|
||||
0x8e08 4 0 Vendor specific
|
||||
0x8e09 4 0 Vendor specific
|
||||
0x8e0a 4 0 Vendor specific
|
||||
0x8e0b 4 0 Vendor specific
|
||||
0x8e0c 4 0 Vendor specific
|
||||
0x8e0d 4 0 Vendor specific
|
||||
0x8e0e 4 0 Vendor specific
|
||||
0x8e0f 4 0 Vendor specific
|
||||
0x8e10 4 0 Vendor specific
|
||||
0x8e11 4 0 Vendor specific
|
||||
|
||||
190
HDD/Seagate/ST500/ST500LM021-1KJ152/6C78199707FD
Normal file
190
HDD/Seagate/ST500/ST500LM021-1KJ152/6C78199707FD
Normal file
@@ -0,0 +1,190 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Laptop HDD
|
||||
Device Model: ST500LM021-1KJ152
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001SDM1
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon Jun 1 13:20:27 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 82) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 114 100 006 - 74354064
|
||||
3 Spin_Up_Time PO---- 098 098 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 374
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 069 060 030 - 8001839
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 2436 (81 239 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 353
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 2
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 055 043 045 Past 45 (Min/Max 21/45 #6)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 6
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 7
|
||||
193 Load_Cycle_Count -O--CK 098 098 000 - 5077
|
||||
194 Temperature_Celsius -O---K 045 057 000 - 45 (0 13 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 100 000 - 192 (239 122 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 1348850764
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1979671755
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 65 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2864 Device vendor specific log
|
||||
0xbd-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 18 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 2431 -
|
||||
# 2 Short offline Completed without error 00% 2218 -
|
||||
# 3 Extended offline Completed without error 00% 2214 -
|
||||
# 4 Extended offline Completed without error 00% 1898 -
|
||||
# 5 Extended offline Completed without error 00% 1533 -
|
||||
# 6 Extended offline Completed without error 00% 1270 -
|
||||
# 7 Extended offline Completed without error 00% 942 -
|
||||
# 8 Extended offline Completed without error 00% 931 -
|
||||
# 9 Extended offline Completed without error 00% 500 -
|
||||
#10 Extended offline Completed without error 00% 450 -
|
||||
#11 Extended offline Completed without error 00% 416 -
|
||||
#12 Extended offline Interrupted (host reset) 00% 38 -
|
||||
#13 Short offline Completed without error 00% 23 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/45 Celsius
|
||||
Lifetime Min/Max Temperature: 13/57 Celsius
|
||||
Specified Max Operating Temperature: 45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 30 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (32)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
175
HDD/Seagate/ST500/ST500LM021-1KJ152/8834A4EAFC7A
Normal file
175
HDD/Seagate/ST500/ST500LM021-1KJ152/8834A4EAFC7A
Normal file
@@ -0,0 +1,175 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Laptop HDD
|
||||
Device Model: ST500LM021-1KJ152
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0003LIM1
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri May 22 09:58:59 2020 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 81) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x1031) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 115 099 034 - 86243112
|
||||
3 Spin_Up_Time PO---- 099 098 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1108
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 081 060 030 - 135566505
|
||||
9 Power_On_Hours -O--CK 091 091 000 - 8494 (253 126 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1107
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 059 041 045 Past 41 (Min/Max 25/48 #25)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 34
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 404307
|
||||
194 Temperature_Celsius -O---K 041 059 000 - 41 (128 0 0 0 0)
|
||||
196 Reallocated_Event_Count POSR-- 093 093 030 - 6303 (40424 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 65 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2864 Device vendor specific log
|
||||
0xbd-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 18 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/48 Celsius
|
||||
Lifetime Min/Max Temperature: 8/58 Celsius
|
||||
Under/Over Temperature Limit Count: 0/1341
|
||||
Vendor specific:
|
||||
00 00 00 00 00 00 00 00 00 00 02 00 00 00 00 00
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 11 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (60)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
204
HDD/Seagate/ST500/ST500LM030-2E717D/B6A38423E772
Normal file
204
HDD/Seagate/ST500/ST500LM030-2E717D/B6A38423E772
Normal file
@@ -0,0 +1,204 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 2.5 5400
|
||||
Device Model: ST500LM030-2E717D
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SDM1
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun May 31 09:39:04 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 84) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 079 064 006 - 85129661
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1644
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 068 060 045 - 6045112
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 1338 (125 107 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 191
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 065 052 040 - 35 (Min/Max 20/35)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 1
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 14
|
||||
193 Load_Cycle_Count -O--CK 095 095 000 - 10197
|
||||
194 Temperature_Celsius -O---K 035 048 000 - 35 (0 10 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 369 (238 29 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 2976148524
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 5931973172
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa8 GPL,SL VS 136 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 8920 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc2 GPL,SL VS 240 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xc9 GPL,SL VS 1 Device vendor specific log
|
||||
0xca GPL,SL VS 16 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/35 Celsius
|
||||
Lifetime Min/Max Temperature: 10/48 Celsius
|
||||
Specified Max Operating Temperature: 35 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 30 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (102)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 191 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1338 --- Power-on Hours
|
||||
0x01 0x018 6 2976155388 --- Logical Sectors Written
|
||||
0x01 0x020 6 17350973 --- Number of Write Commands
|
||||
0x01 0x028 6 5931975036 --- Logical Sectors Read
|
||||
0x01 0x030 6 56305414 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 844 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 7 --- Head Flying Hours
|
||||
0x03 0x018 4 10197 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
100
HDD/Seagate/ST5000/ST5000DM000-1FK178/2F3183103AD9
Normal file
100
HDD/Seagate/ST5000/ST5000DM000-1FK178/2F3183103AD9
Normal file
@@ -0,0 +1,100 @@
|
||||
smartctl 6.6 2017-11-05 r4594 [MidnightBSD 1.2 amd64] (local build)
|
||||
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Desktop HDD.15
|
||||
Device Model: ST5000DM000-1FK178
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC41
|
||||
User Capacity: 5,000,981,078,016 bytes [5.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5980 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri May 22 12:06:36 2020 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 642) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3025) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x000f 114 100 006 Pre-fail Always - 71450288
|
||||
3 Spin_Up_Time 0x0003 092 091 000 Pre-fail Always - 0
|
||||
4 Start_Stop_Count 0x0032 067 067 020 Old_age Always - 34050
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
7 Seek_Error_Rate 0x000f 082 060 030 Pre-fail Always - 48942441472
|
||||
9 Power_On_Hours 0x0032 062 062 000 Old_age Always - 33288
|
||||
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
|
||||
12 Power_Cycle_Count 0x0032 067 067 020 Old_age Always - 34053
|
||||
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
|
||||
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
|
||||
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
|
||||
188 Command_Timeout 0x0032 100 098 000 Old_age Always - 7 7 36
|
||||
189 High_Fly_Writes 0x003a 094 094 000 Old_age Always - 6
|
||||
190 Airflow_Temperature_Cel 0x0022 060 048 045 Old_age Always - 40 (Min/Max 35/43)
|
||||
194 Temperature_Celsius 0x0022 040 052 000 Old_age Always - 40 (0 18 0 0 0)
|
||||
195 Hardware_ECC_Recovered 0x001a 114 100 000 Old_age Always - 71450288
|
||||
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
|
||||
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
|
||||
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
|
||||
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 25439h+43m+46.678s
|
||||
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 62890329714
|
||||
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 12550340456329
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 18966 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
|
||||
|
||||
227
HDD/Seagate/ST6000/ST6000DM003-2CY186/E62AC93B0E19
Normal file
227
HDD/Seagate/ST6000/ST6000DM003-2CY186/E62AC93B0E19
Normal file
@@ -0,0 +1,227 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda Compute
|
||||
Device Model: ST6000DM003-2CY186
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001
|
||||
User Capacity: 6,001,175,126,016 bytes [6.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5425 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed May 27 00:19:36 2020 +07
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 783) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x30a5) SCT Status supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 075 064 006 - 34059461
|
||||
3 Spin_Up_Time PO---- 093 092 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 248
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 079 060 045 - 82031308
|
||||
9 Power_On_Hours -O--CK 080 080 000 - 18370 (150 50 0)
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 217
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 3
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 053 034 040 Past 47 (Min/Max 39/51 #252)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 231
|
||||
193 Load_Cycle_Count -O--CK 099 099 000 - 2033
|
||||
194 Temperature_Celsius -O---K 047 066 000 - 47 (0 17 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 075 064 000 - 34059461
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 5108 (79 145 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 18960883277
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 22153175087
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x0c GPL R/O 2048 Pending Defects log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x24 GPL R/O 512 Current Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 24 Device vendor specific log
|
||||
0xa2 GPL VS 8160 Device vendor specific log
|
||||
0xa6 GPL VS 192 Device vendor specific log
|
||||
0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 9048 Device vendor specific log
|
||||
0xbd GPL VS 8 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 16 Device vendor specific log
|
||||
0xc3 GPL,SL VS 8 Device vendor specific log
|
||||
0xc4 GPL,SL VS 24 Device vendor specific log
|
||||
0xd1 GPL VS 264 Device vendor specific log
|
||||
0xd3 GPL VS 1920 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 47 Celsius
|
||||
Power Cycle Min/Max Temperature: 39/51 Celsius
|
||||
Lifetime Min/Max Temperature: 17/66 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 3 minutes
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (89)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 217 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 18370 --- Power-on Hours
|
||||
0x01 0x018 6 18973384565 --- Logical Sectors Written
|
||||
0x01 0x020 6 95520869 --- Number of Write Commands
|
||||
0x01 0x028 6 22171813328 --- Logical Sectors Read
|
||||
0x01 0x030 6 211993909 --- Number of Read Commands
|
||||
0x01 0x038 6 - --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 16833 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 5189 --- Head Flying Hours
|
||||
0x03 0x018 4 2033 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
||||
0x03 0x040 4 231 --- Number of High Priority Unload Events
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 5 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 47 --- Current Temperature
|
||||
0x05 0x010 1 46 --- Average Short Term Temperature
|
||||
0x05 0x018 1 47 --- Average Long Term Temperature
|
||||
0x05 0x020 1 66 --- Highest Temperature
|
||||
0x05 0x028 1 0 --- Lowest Temperature
|
||||
0x05 0x030 1 59 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 44 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 53 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 46 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 50339 --- Time in Over-Temperature
|
||||
0x05 0x058 1 55 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 550 --- Time in Under-Temperature
|
||||
0x05 0x068 1 13 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 7 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c)
|
||||
No Defects Logged
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
105
HDD/Seagate/ST8000/ST8000VN0002-1Z8112/CDF29EC5DCF0
Normal file
105
HDD/Seagate/ST8000/ST8000VN0002-1Z8112/CDF29EC5DCF0
Normal file
@@ -0,0 +1,105 @@
|
||||
smartctl 6.6 2017-11-05 r4594 [MidnightBSD 1.2 amd64] (local build)
|
||||
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate NAS HDD
|
||||
Device Model: ST8000VN0002-1Z8112
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC61
|
||||
User Capacity: 8,001,563,222,016 bytes [8.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri May 22 12:06:38 2020 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 703) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x000f 080 064 044 Pre-fail Always - 99704808
|
||||
3 Spin_Up_Time 0x0003 086 084 000 Pre-fail Always - 0
|
||||
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 23
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
7 Seek_Error_Rate 0x000f 095 060 045 Pre-fail Always - 3093872723
|
||||
9 Power_On_Hours 0x0032 083 083 000 Old_age Always - 15010 (203 228 0)
|
||||
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
|
||||
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 23
|
||||
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
|
||||
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
|
||||
188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
|
||||
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0022 050 049 040 Old_age Always - 50 (Min/Max 42/51)
|
||||
191 G-Sense_Error_Rate 0x0032 088 088 000 Old_age Always - 25137
|
||||
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 22
|
||||
193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 168
|
||||
194 Temperature_Celsius 0x0022 050 051 000 Old_age Always - 50 (0 23 0 0 0)
|
||||
195 Hardware_ECC_Recovered 0x001a 006 001 000 Old_age Always - 99704808
|
||||
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
|
||||
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
|
||||
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
|
||||
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 14961 (38 128 0)
|
||||
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 136371555574
|
||||
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 54702901342
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 638 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
|
||||
|
||||
105
HDD/Seagate/ST8000/ST8000VN0022-2EL112/59D3FB96B73C
Normal file
105
HDD/Seagate/ST8000/ST8000VN0022-2EL112/59D3FB96B73C
Normal file
@@ -0,0 +1,105 @@
|
||||
smartctl 6.6 2017-11-05 r4594 [MidnightBSD 1.2 amd64] (local build)
|
||||
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate IronWolf
|
||||
Device Model: ST8000VN0022-2EL112
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SC61
|
||||
User Capacity: 8,001,563,222,016 bytes [8.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri May 22 12:06:35 2020 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 567) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 790) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x50bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x000f 079 064 044 Pre-fail Always - 87370392
|
||||
3 Spin_Up_Time 0x0003 086 085 000 Pre-fail Always - 0
|
||||
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 25
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
7 Seek_Error_Rate 0x000f 095 060 045 Pre-fail Always - 3508361845
|
||||
9 Power_On_Hours 0x0032 082 082 000 Old_age Always - 15801
|
||||
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
|
||||
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 25
|
||||
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
|
||||
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
|
||||
188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
|
||||
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0022 053 047 040 Old_age Always - 47 (Min/Max 40/47)
|
||||
191 G-Sense_Error_Rate 0x0032 070 070 000 Old_age Always - 61882
|
||||
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 497
|
||||
193 Load_Cycle_Count 0x0032 098 098 000 Old_age Always - 4007
|
||||
194 Temperature_Celsius 0x0022 047 049 000 Old_age Always - 47 (0 22 0 0 0)
|
||||
195 Hardware_ECC_Recovered 0x001a 006 001 000 Old_age Always - 87370392
|
||||
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
|
||||
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
|
||||
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
|
||||
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 13438 (60 145 0)
|
||||
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 133002770270
|
||||
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 53264621999
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 1429 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
|
||||
|
||||
174
HDD/Seagate/ST9100/ST91000640NS/66832ACE4BF6
Normal file
174
HDD/Seagate/ST9100/ST91000640NS/66832ACE4BF6
Normal file
@@ -0,0 +1,174 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Constellation.2 (SATA)
|
||||
Device Model: ST91000640NS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: SN03
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed May 27 00:19:35 2020 +07
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 642) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 204) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x10bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 082 063 044 - 176607219
|
||||
3 Spin_Up_Time PO---- 094 094 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 446
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 079 060 030 - 96547746
|
||||
9 Power_On_Hours -O--CK 056 056 000 - 39125
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 442
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 048 038 045 Past 52 (Min/Max 42/53 #1486)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 194
|
||||
193 Load_Cycle_Count -O--CK 098 098 000 - 4588
|
||||
194 Temperature_Celsius -O---K 052 062 000 - 52 (0 15 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 118 099 000 - 176607219
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x12 GPL,SL R/O 1 SATA NCQ Non-Data log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xb6 GPL VS 1918 Device vendor specific log
|
||||
0xbd GPL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 52 Celsius
|
||||
Power Cycle Min/Max Temperature: 42/53 Celsius
|
||||
Lifetime Min/Max Temperature: 15/62 Celsius
|
||||
Under/Over Temperature Limit Count: 0/130
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (120)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 100 (10.0 seconds)
|
||||
Write: 100 (10.0 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
170
HDD/Seagate/ST9250/ST9250315AS/C8D7EF8B922C
Normal file
170
HDD/Seagate/ST9250/ST9250315AS/C8D7EF8B922C
Normal file
@@ -0,0 +1,170 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Momentus 5400.6
|
||||
Device Model: ST9250315AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0001SDM1
|
||||
User Capacity: 250,059,350,016 bytes [250 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Mon May 25 14:35:09 2020 IST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 68) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x103b) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 117 099 006 - 127088687
|
||||
3 Spin_Up_Time PO---- 099 099 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 236
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 078 060 030 - 76917318
|
||||
9 Power_On_Hours -O--CK 068 068 000 - 28630
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 037 020 - 229
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 2
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 063 054 045 - 37 (Min/Max 28/42)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 27
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1711017
|
||||
194 Temperature_Celsius -O---K 037 046 000 - 37 (0 9 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 048 045 000 - 127088687
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 65 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2864 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/42 Celsius
|
||||
Lifetime Min/Max Temperature: 9/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/398740
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/ 0 Celsius
|
||||
Min/Max Temperature Limit: 0/ 0 Celsius
|
||||
Temperature History Size (Index): 128 (96)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 16 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
||||
323
HDD/Seagate/ST9500/ST9500420AS/5C72704B9149
Normal file
323
HDD/Seagate/ST9500/ST9500420AS/5C72704B9149
Normal file
@@ -0,0 +1,323 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Momentus 7200.4
|
||||
Device Model: ST9500420AS
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: 0002SDM1
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Fri May 22 20:15:41 2020 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 109) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 117 095 006 - 133453809
|
||||
3 Spin_Up_Time PO---- 097 097 085 - 0
|
||||
4 Start_Stop_Count -O--CK 097 097 020 - 3782
|
||||
5 Reallocated_Sector_Ct PO--CK 082 082 036 - 383
|
||||
7 Seek_Error_Rate POSR-- 066 060 030 - 610515543201
|
||||
9 Power_On_Hours -O--CK 092 092 000 - 7572
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 037 020 - 3745
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 001 001 000 - 355
|
||||
188 Command_Timeout -O--CK 100 099 000 - 50
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 069 034 045 Past 31 (1 2 31 26 0)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 1908
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 47
|
||||
193 Load_Cycle_Count -O--CK 031 031 000 - 138626
|
||||
194 Temperature_Celsius -O---K 031 066 000 - 31 (0 12 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 045 035 000 - 133453809
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 11123 (24 161 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 4261504153
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1991722912
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL,SL R/O 1 Write stream error log
|
||||
0x22 GPL,SL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 65 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2864 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
Device Error Count: 513 (device log contains only the most recent 20 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 513 [12] occurred at disk power-on lifetime: 5607 hours (233 days + 15 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 2f 9e 00 32 8d 00 00 Error: UNC at LBA = 0x2f9e00328d = 204514275981
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 00 80 00 2f 9e 00 32 80 40 00 11:50:29.118 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 00 11:50:29.091 READ LOG EXT
|
||||
60 00 00 00 80 00 2f 9e 00 32 80 40 00 11:50:26.414 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 00 11:50:26.310 READ LOG EXT
|
||||
60 00 00 00 80 00 2f 9e 00 32 80 40 00 11:50:23.621 READ FPDMA QUEUED
|
||||
|
||||
Error 512 [11] occurred at disk power-on lifetime: 5607 hours (233 days + 15 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 2f 9e 00 32 8d 00 00 Error: UNC at LBA = 0x2f9e00328d = 204514275981
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 00 80 00 2f 9e 00 32 80 40 00 11:50:20.942 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 00 11:50:20.922 READ LOG EXT
|
||||
60 00 00 00 80 00 2f 0a 00 2f 80 40 00 11:50:16.502 READ FPDMA QUEUED
|
||||
60 00 00 00 80 00 2f 0a 00 2f 00 40 00 11:50:16.485 READ FPDMA QUEUED
|
||||
60 00 00 00 80 00 2f d7 00 2a 80 40 00 11:50:14.470 READ FPDMA QUEUED
|
||||
|
||||
Error 511 [10] occurred at disk power-on lifetime: 5607 hours (233 days + 15 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 2f 9e 00 32 8d 00 00 Error: UNC at LBA = 0x2f9e00328d = 204514275981
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 00 80 00 2f 0a 00 2f 80 40 00 11:50:16.502 READ FPDMA QUEUED
|
||||
60 00 00 00 80 00 2f 0a 00 2f 00 40 00 11:50:16.485 READ FPDMA QUEUED
|
||||
60 00 00 00 80 00 2f d7 00 2a 80 40 00 11:50:14.470 READ FPDMA QUEUED
|
||||
60 00 00 00 80 00 2f d7 00 2a 00 40 00 11:50:14.460 READ FPDMA QUEUED
|
||||
60 00 00 00 80 00 2f 63 00 20 00 40 00 11:50:09.467 READ FPDMA QUEUED
|
||||
|
||||
Error 510 [9] occurred at disk power-on lifetime: 5101 hours (212 days + 13 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 2f 9e 00 32 8d 00 00 Error: UNC at LBA = 0x2f9e00328d = 204514275981
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 01 00 00 2c b1 00 09 90 40 00 1d+00:02:08.525 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 2c b0 00 09 90 40 00 1d+00:02:08.525 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 2c af 00 09 90 40 00 1d+00:02:08.524 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 2c ae 00 09 90 40 00 1d+00:02:08.524 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 2c ad 00 09 90 40 00 1d+00:02:08.523 READ FPDMA QUEUED
|
||||
|
||||
Error 509 [8] occurred at disk power-on lifetime: 5101 hours (212 days + 13 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 2f 9e 00 32 8d 00 00 Error: UNC at LBA = 0x2f9e00328d = 204514275981
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 01 00 00 31 81 00 5d b0 40 00 1d+00:02:05.487 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 31 80 00 5d b0 40 00 1d+00:02:05.487 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 31 7f 00 5d b0 40 00 1d+00:02:05.486 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 31 7e 00 5d b0 40 00 1d+00:02:05.483 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 31 7d 00 5d b0 40 00 1d+00:02:05.482 READ FPDMA QUEUED
|
||||
|
||||
Error 508 [7] occurred at disk power-on lifetime: 5101 hours (212 days + 13 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 2f 9e 00 32 8d 00 00 Error: UNC at LBA = 0x2f9e00328d = 204514275981
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 01 00 00 2c 84 00 09 90 40 00 1d+00:02:02.411 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 2c 83 00 09 90 40 00 1d+00:02:02.410 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 2c 82 00 09 90 40 00 1d+00:02:02.410 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 2c 81 00 09 90 40 00 1d+00:02:02.409 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 2c 80 00 09 90 40 00 1d+00:02:02.409 READ FPDMA QUEUED
|
||||
|
||||
Error 507 [6] occurred at disk power-on lifetime: 5101 hours (212 days + 13 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 2f 9e 00 32 8d 00 00 Error: UNC at LBA = 0x2f9e00328d = 204514275981
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 01 00 00 2c 72 00 09 90 40 00 1d+00:01:59.308 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 2c 71 00 09 90 40 00 1d+00:01:59.308 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 2c 70 00 09 90 40 00 1d+00:01:59.307 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 2c 6f 00 09 90 40 00 1d+00:01:59.307 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 2c 6e 00 09 90 40 00 1d+00:01:59.306 READ FPDMA QUEUED
|
||||
|
||||
Error 506 [5] occurred at disk power-on lifetime: 5101 hours (212 days + 13 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 2f 9e 00 32 8d 00 00 Error: WP at LBA = 0x2f9e00328d = 204514275981
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 00 00 08 00 02 f8 00 30 60 40 00 1d+00:01:55.350 WRITE FPDMA QUEUED
|
||||
60 00 00 01 00 00 31 79 00 5d b0 40 00 1d+00:01:55.349 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 31 78 00 5d b0 40 00 1d+00:01:55.348 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 31 77 00 5d b0 40 00 1d+00:01:55.341 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 31 76 00 5d b0 40 00 1d+00:01:55.339 READ FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/31 Celsius
|
||||
Lifetime Min/Max Temperature: 12/66 Celsius
|
||||
Specified Max Operating Temperature: 38 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (20)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
212
HDD/Toshiba/DT01/DT01ACA100/69726981F75F
Normal file
212
HDD/Toshiba/DT01/DT01ACA100/69726981F75F
Normal file
@@ -0,0 +1,212 @@
|
||||
smartctl 6.6 2017-11-05 r4594 [FreeBSD 10.4-RELEASE-p13 amd64] (local build)
|
||||
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Toshiba 3.5" DT01ACA... Desktop HDD
|
||||
Device Model: TOSHIBA DT01ACA100
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000039 ...
|
||||
Add. Product Id: DELL(tm)
|
||||
Firmware Version: MS2OA810
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri May 29 12:12:17 2020 JST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 7119) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 119) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 65536
|
||||
2 Throughput_Performance --S--- 142 142 000 - 70
|
||||
3 Spin_Up_Time POS--- 126 126 024 - 183 (Average 180)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 27
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate -O-R-- 100 100 000 - 0
|
||||
8 Seek_Time_Performance --S--- 110 110 000 - 36
|
||||
9 Power_On_Hours -O--C- 097 097 000 - 25574
|
||||
10 Spin_Retry_Count -O--C- 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 18
|
||||
192 Power-Off_Retract_Count -O--CK 084 084 000 - 19597
|
||||
193 Load_Cycle_Count -O--C- 084 084 000 - 19597
|
||||
194 Temperature_Celsius -O---- 152 152 000 - 36 (Min/Max 21/43)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
240 Head_Flying_Hours -O--C- 097 097 000 - 25555
|
||||
241 Total_LBAs_Written -O--C- 100 100 000 - 17566876625
|
||||
242 Total_LBAs_Read -O--C- 100 100 000 - 1610380054
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 7 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 2 -
|
||||
# 2 Extended offline Completed without error 00% 2 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
SCT Support Level: 1
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/42 Celsius
|
||||
Lifetime Min/Max Temperature: 21/43 Celsius
|
||||
Lifetime Average Temperature: 33 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 15/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 478 (346)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 18 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 25574 --- Power-on Hours
|
||||
0x01 0x018 6 17566877698 --- Logical Sectors Written
|
||||
0x01 0x020 6 271899265 --- Number of Write Commands
|
||||
0x01 0x028 6 44266505946 --- Logical Sectors Read
|
||||
0x01 0x030 6 17641725 --- Number of Read Commands
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 25557 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 25555 --- Head Flying Hours
|
||||
0x03 0x018 4 19597 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 9 --- Read Recovery Attempts
|
||||
0x03 0x030 4 2 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 36 --- Current Temperature
|
||||
0x05 0x010 1 36 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 32 N-- Average Long Term Temperature
|
||||
0x05 0x020 1 43 --- Highest Temperature
|
||||
0x05 0x028 1 21 --- Lowest Temperature
|
||||
0x05 0x030 1 41 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 23 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 39 N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 55 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 15 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 218 --- Number of Hardware Resets
|
||||
0x06 0x010 4 200 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 19 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
||||
210
HDD/Toshiba/DT01/DT01ACA100/7D00B503FDFE
Normal file
210
HDD/Toshiba/DT01/DT01ACA100/7D00B503FDFE
Normal file
@@ -0,0 +1,210 @@
|
||||
smartctl 6.6 2017-11-05 r4594 [FreeBSD 10.4-RELEASE-p13 amd64] (local build)
|
||||
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Toshiba 3.5" DT01ACA... Desktop HDD
|
||||
Device Model: TOSHIBA DT01ACA100
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000039 ...
|
||||
Add. Product Id: DELL(tm)
|
||||
Firmware Version: MS2OA810
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri May 29 12:12:20 2020 JST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 7216) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 121) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
||||
2 Throughput_Performance --S--- 143 143 000 - 67
|
||||
3 Spin_Up_Time POS--- 126 126 024 - 182 (Average 183)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 27
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate -O-R-- 100 100 000 - 0
|
||||
8 Seek_Time_Performance --S--- 110 110 000 - 36
|
||||
9 Power_On_Hours -O--C- 097 097 000 - 25573
|
||||
10 Spin_Retry_Count -O--C- 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 18
|
||||
192 Power-Off_Retract_Count -O--CK 099 099 000 - 1427
|
||||
193 Load_Cycle_Count -O--C- 099 099 000 - 1427
|
||||
194 Temperature_Celsius -O---- 152 152 000 - 36 (Min/Max 22/47)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
240 Head_Flying_Hours -O--C- 097 097 000 - 24209
|
||||
241 Total_LBAs_Written -O--C- 100 100 000 - 492793382
|
||||
242 Total_LBAs_Read -O--C- 100 100 000 - 20506940
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 7 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 2 -
|
||||
# 2 Extended offline Completed without error 00% 2 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
SCT Support Level: 1
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/43 Celsius
|
||||
Lifetime Min/Max Temperature: 22/47 Celsius
|
||||
Lifetime Average Temperature: 34 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 15/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 478 (226)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 18 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 25573 --- Power-on Hours
|
||||
0x01 0x018 6 492793382 --- Logical Sectors Written
|
||||
0x01 0x020 6 2003167 --- Number of Write Commands
|
||||
0x01 0x028 6 1930105297246 --- Logical Sectors Read
|
||||
0x01 0x030 6 66043 --- Number of Read Commands
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 24209 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 24209 --- Head Flying Hours
|
||||
0x03 0x018 4 1427 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 2 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 35 --- Current Temperature
|
||||
0x05 0x010 1 35 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 32 N-- Average Long Term Temperature
|
||||
0x05 0x020 1 47 --- Highest Temperature
|
||||
0x05 0x028 1 22 --- Lowest Temperature
|
||||
0x05 0x030 1 42 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 24 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 40 N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 55 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 15 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 218 --- Number of Hardware Resets
|
||||
0x06 0x010 4 200 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 19 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
204
HDD/Toshiba/DT01/DT01ACA100/EE4AA8A0E670
Normal file
204
HDD/Toshiba/DT01/DT01ACA100/EE4AA8A0E670
Normal file
@@ -0,0 +1,204 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Toshiba 3.5" DT01ACA... Desktop HDD
|
||||
Device Model: TOSHIBA DT01ACA100
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000039 ...
|
||||
Firmware Version: MS2OA750
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu May 28 16:24:04 2020 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 7361) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 123) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
||||
2 Throughput_Performance P-S--- 141 141 054 - 72
|
||||
3 Spin_Up_Time POS--- 122 122 024 - 182 (Average 194)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 1574
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 118 118 020 - 33
|
||||
9 Power_On_Hours -O--C- 094 094 000 - 46622
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1565
|
||||
192 Power-Off_Retract_Count -O--CK 099 099 000 - 1727
|
||||
193 Load_Cycle_Count -O--C- 099 099 000 - 1727
|
||||
194 Temperature_Celsius -O---- 122 122 000 - 49 (Min/Max 16/53)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 7 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 49 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/50 Celsius
|
||||
Lifetime Min/Max Temperature: 16/53 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/70 Celsius
|
||||
Temperature History Size (Index): 128 (7)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1565 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 46622 --- Power-on Hours
|
||||
0x01 0x018 6 27924055133 --- Logical Sectors Written
|
||||
0x01 0x020 6 667908813 --- Number of Write Commands
|
||||
0x01 0x028 6 336327149078 --- Logical Sectors Read
|
||||
0x01 0x030 6 282022488 --- Number of Read Commands
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 46614 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 46614 --- Head Flying Hours
|
||||
0x03 0x018 4 1727 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 9 --- Read Recovery Attempts
|
||||
0x03 0x030 4 14 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 49 --- Current Temperature
|
||||
0x05 0x010 1 49 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 45 N-- Average Long Term Temperature
|
||||
0x05 0x020 1 53 --- Highest Temperature
|
||||
0x05 0x028 1 16 --- Lowest Temperature
|
||||
0x05 0x030 1 50 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 25 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 48 N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 4724 --- Number of Hardware Resets
|
||||
0x06 0x010 4 3163 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 11 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
||||
204
HDD/Toshiba/DT01/DT01ACA200/3AA1524DEFBE
Normal file
204
HDD/Toshiba/DT01/DT01ACA200/3AA1524DEFBE
Normal file
@@ -0,0 +1,204 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Toshiba 3.5" DT01ACA... Desktop HDD
|
||||
Device Model: TOSHIBA DT01ACA200
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000039 ...
|
||||
Firmware Version: MX4OABB0
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 13:04:41 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (15013) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 251) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
||||
2 Throughput_Performance P-S--- 139 139 054 - 70
|
||||
3 Spin_Up_Time POS--- 126 126 024 - 299 (Average 300)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 84
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 124 124 020 - 33
|
||||
9 Power_On_Hours -O--C- 094 094 000 - 47811
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 84
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 545
|
||||
193 Load_Cycle_Count -O--C- 100 100 000 - 545
|
||||
194 Temperature_Celsius -O---- 193 193 000 - 31 (Min/Max 13/49)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 7 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/33 Celsius
|
||||
Lifetime Min/Max Temperature: 13/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/70 Celsius
|
||||
Temperature History Size (Index): 128 (106)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 84 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 47811 --- Power-on Hours
|
||||
0x01 0x018 6 96377536160 --- Logical Sectors Written
|
||||
0x01 0x020 6 2155211352 --- Number of Write Commands
|
||||
0x01 0x028 6 43237019840 --- Logical Sectors Read
|
||||
0x01 0x030 6 889434285 --- Number of Read Commands
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 47804 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 47804 --- Head Flying Hours
|
||||
0x03 0x018 4 545 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 3 --- Read Recovery Attempts
|
||||
0x03 0x030 4 6 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 31 --- Current Temperature
|
||||
0x05 0x010 1 30 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 31 N-- Average Long Term Temperature
|
||||
0x05 0x020 1 49 --- Highest Temperature
|
||||
0x05 0x028 1 13 --- Lowest Temperature
|
||||
0x05 0x030 1 42 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 23 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 39 N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 351 --- Number of Hardware Resets
|
||||
0x06 0x010 4 332 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
||||
202
HDD/Toshiba/DT01/DT01ACA200/60FF9E9DD9F2
Normal file
202
HDD/Toshiba/DT01/DT01ACA200/60FF9E9DD9F2
Normal file
@@ -0,0 +1,202 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Toshiba 3.5" DT01ACA... Desktop HDD
|
||||
Device Model: TOSHIBA DT01ACA200
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000039 ...
|
||||
Firmware Version: MX4OABB0
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 13:04:44 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (15109) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 252) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
||||
2 Throughput_Performance P-S--- 138 138 054 - 74
|
||||
3 Spin_Up_Time POS--- 128 128 024 - 295 (Average 296)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 84
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 119 119 020 - 35
|
||||
9 Power_On_Hours -O--C- 094 094 000 - 47806
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 84
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 543
|
||||
193 Load_Cycle_Count -O--C- 100 100 000 - 543
|
||||
194 Temperature_Celsius -O---- 187 187 000 - 32 (Min/Max 14/51)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 7 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/33 Celsius
|
||||
Lifetime Min/Max Temperature: 14/51 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/70 Celsius
|
||||
Temperature History Size (Index): 128 (56)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 84 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 47806 --- Power-on Hours
|
||||
0x01 0x018 6 92072469592 --- Logical Sectors Written
|
||||
0x01 0x020 6 2085067383 --- Number of Write Commands
|
||||
0x01 0x028 6 41250352706 --- Logical Sectors Read
|
||||
0x01 0x030 6 870065114 --- Number of Read Commands
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 47799 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 47799 --- Head Flying Hours
|
||||
0x03 0x018 4 543 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 5 --- Read Recovery Attempts
|
||||
0x03 0x030 4 6 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 32 --- Current Temperature
|
||||
0x05 0x010 1 31 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 31 N-- Average Long Term Temperature
|
||||
0x05 0x020 1 51 --- Highest Temperature
|
||||
0x05 0x028 1 14 --- Lowest Temperature
|
||||
0x05 0x030 1 45 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 25 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 41 N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 352 --- Number of Hardware Resets
|
||||
0x06 0x010 4 327 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
204
HDD/Toshiba/DT01/DT01ACA200/6ABB040F667C
Normal file
204
HDD/Toshiba/DT01/DT01ACA200/6ABB040F667C
Normal file
@@ -0,0 +1,204 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Toshiba 3.5" DT01ACA... Desktop HDD
|
||||
Device Model: TOSHIBA DT01ACA200
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000039 ...
|
||||
Firmware Version: MX4OABB0
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 25 13:04:39 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (15300) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 255) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
|
||||
2 Throughput_Performance P-S--- 140 140 054 - 68
|
||||
3 Spin_Up_Time POS--- 127 127 024 - 300 (Average 297)
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 83
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 124 124 020 - 33
|
||||
9 Power_On_Hours -O--C- 094 094 000 - 47816
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 83
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 552
|
||||
193 Load_Cycle_Count -O--C- 100 100 000 - 552
|
||||
194 Temperature_Celsius -O---- 193 193 000 - 31 (Min/Max 14/51)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 7 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x08 GPL R/O 2 Power Conditions log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x20 GPL R/O 1 Streaming performance log [OBS-8]
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/32 Celsius
|
||||
Lifetime Min/Max Temperature: 14/51 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/70 Celsius
|
||||
Temperature History Size (Index): 128 (18)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 83 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 47816 --- Power-on Hours
|
||||
0x01 0x018 6 92548378728 --- Logical Sectors Written
|
||||
0x01 0x020 6 2099054067 --- Number of Write Commands
|
||||
0x01 0x028 6 40341003246 --- Logical Sectors Read
|
||||
0x01 0x030 6 846661194 --- Number of Read Commands
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 47809 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 47809 --- Head Flying Hours
|
||||
0x03 0x018 4 552 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 1 --- Read Recovery Attempts
|
||||
0x03 0x030 4 6 --- Number of Mechanical Start Failures
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 31 --- Current Temperature
|
||||
0x05 0x010 1 30 N-- Average Short Term Temperature
|
||||
0x05 0x018 1 31 N-- Average Long Term Temperature
|
||||
0x05 0x020 1 51 --- Highest Temperature
|
||||
0x05 0x028 1 14 --- Lowest Temperature
|
||||
0x05 0x030 1 45 N-- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 23 N-- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 41 N-- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 25 N-- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 389 --- Number of Hardware Resets
|
||||
0x06 0x010 4 367 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
||||
Some files were not shown because too many files have changed in this diff Show More
Reference in New Issue
Block a user