mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 129, modified: 0)
This commit is contained in:
342
HDD/Seagate/ST2000/ST2000DL003-9VT166/AFBF6EF0CAA2
Normal file
342
HDD/Seagate/ST2000/ST2000DL003-9VT166/AFBF6EF0CAA2
Normal file
@@ -0,0 +1,342 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda Green (AF)
|
||||
Device Model: ST2000DL003-9VT166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC32
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Jun 5 10:59:27 2020 -03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 0 (vendor specific), recommended: 254
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 623) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 340) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x30b7) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 114 099 006 - 76584848
|
||||
3 Spin_Up_Time PO---- 093 091 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1881
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 072 060 030 - 30214917582
|
||||
9 Power_On_Hours -O--CK 047 047 000 - 47142
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1890
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 098 098 000 - 2
|
||||
188 Command_Timeout -O--CK 100 099 000 - 1
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 064 052 045 - 36 (Min/Max 27/39)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 1841
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 1954
|
||||
194 Temperature_Celsius -O---K 036 048 000 - 36 (0 17 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 020 004 000 - 76584848
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 46991 (228 90 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 2643836350
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1972438971
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 20 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2819 Device vendor specific log
|
||||
0xbd GPL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
Device Error Count: 15
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 15 [14] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c7 00 00 Error: UNC at LBA = 0xc385f0c7 = 3280335047
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:31.810 READ FPDMA QUEUED
|
||||
60 00 00 00 10 00 00 03 56 b4 e0 40 00 22:15:31.672 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c6 40 00 22:15:31.672 WRITE FPDMA QUEUED
|
||||
60 00 00 00 10 00 00 03 56 7d 90 40 00 22:15:31.671 READ FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:31.633 CHECK POWER MODE
|
||||
|
||||
Error 14 [13] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c7 00 00 Error: UNC at LBA = 0xc385f0c7 = 3280335047
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:31.810 READ FPDMA QUEUED
|
||||
60 00 00 00 10 00 00 03 56 b4 e0 40 00 22:15:31.672 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c6 40 00 22:15:31.672 WRITE FPDMA QUEUED
|
||||
60 00 00 00 10 00 00 03 56 7d 90 40 00 22:15:31.671 READ FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:31.633 CHECK POWER MODE
|
||||
|
||||
Error 13 [12] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c6 00 00 Error: UNC at LBA = 0xc385f0c6 = 3280335046
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:31.194 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c5 40 00 22:15:31.022 WRITE FPDMA QUEUED
|
||||
60 00 00 00 10 00 00 03 56 05 00 40 00 22:15:31.021 READ FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:30.988 CHECK POWER MODE
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 22:15:30.880 READ LOG EXT
|
||||
|
||||
Error 12 [11] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c6 00 00 Error: UNC at LBA = 0xc385f0c6 = 3280335046
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:31.194 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c5 40 00 22:15:31.022 WRITE FPDMA QUEUED
|
||||
60 00 00 00 10 00 00 03 56 05 00 40 00 22:15:31.021 READ FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:30.988 CHECK POWER MODE
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 22:15:30.880 READ LOG EXT
|
||||
|
||||
Error 11 [10] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c5 00 00 Error: UNC at LBA = 0xc385f0c5 = 3280335045
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:30.558 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c4 40 00 22:15:30.421 WRITE FPDMA QUEUED
|
||||
60 00 00 04 00 00 00 03 55 fc 00 40 00 22:15:30.421 READ FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:30.391 CHECK POWER MODE
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 22:15:30.284 READ LOG EXT
|
||||
|
||||
Error 10 [9] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c5 00 00 Error: UNC at LBA = 0xc385f0c5 = 3280335045
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:30.558 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c4 40 00 22:15:30.421 WRITE FPDMA QUEUED
|
||||
60 00 00 04 00 00 00 03 55 fc 00 40 00 22:15:30.421 READ FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:30.391 CHECK POWER MODE
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 22:15:30.284 READ LOG EXT
|
||||
|
||||
Error 9 [8] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c4 00 00 Error: UNC at LBA = 0xc385f0c4 = 3280335044
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:29.962 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c3 40 00 22:15:29.803 WRITE FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:29.776 CHECK POWER MODE
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 22:15:29.668 READ LOG EXT
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:29.285 READ FPDMA QUEUED
|
||||
|
||||
Error 8 [7] occurred at disk power-on lifetime: 30045 hours (1251 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 c3 85 f0 c4 00 00 Error: UNC at LBA = 0xc385f0c4 = 3280335044
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:29.962 READ FPDMA QUEUED
|
||||
61 00 00 00 01 00 00 c3 85 f0 c3 40 00 22:15:29.803 WRITE FPDMA QUEUED
|
||||
e5 00 00 00 00 00 00 00 00 00 00 00 00 22:15:29.776 CHECK POWER MODE
|
||||
2f 00 00 00 01 00 00 00 00 00 10 00 00 22:15:29.668 READ LOG EXT
|
||||
60 00 00 04 00 00 00 c3 85 f0 00 40 00 22:15:29.285 READ FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 47131 -
|
||||
# 2 Short offline Completed without error 00% 47107 -
|
||||
# 3 Short offline Completed without error 00% 47083 -
|
||||
# 4 Short offline Completed without error 00% 47059 -
|
||||
# 5 Short offline Completed without error 00% 47035 -
|
||||
# 6 Extended offline Completed without error 00% 47016 -
|
||||
# 7 Short offline Completed without error 00% 46987 -
|
||||
# 8 Short offline Completed without error 00% 46963 -
|
||||
# 9 Short offline Completed without error 00% 46939 -
|
||||
#10 Short offline Completed without error 00% 46915 -
|
||||
#11 Short offline Completed without error 00% 46891 -
|
||||
#12 Short offline Completed without error 00% 46867 -
|
||||
#13 Extended offline Completed without error 00% 46848 -
|
||||
#14 Short offline Completed without error 00% 46819 -
|
||||
#15 Short offline Completed without error 00% 46796 -
|
||||
#16 Short offline Completed without error 00% 46772 -
|
||||
#17 Short offline Completed without error 00% 46748 -
|
||||
#18 Short offline Completed without error 00% 46724 -
|
||||
#19 Short offline Completed without error 00% 46700 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/39 Celsius
|
||||
Lifetime Min/Max Temperature: 17/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (95)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 34 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
223
HDD/Seagate/ST2000/ST2000DL003-9VT166/C9B14737E223
Normal file
223
HDD/Seagate/ST2000/ST2000DL003-9VT166/C9B14737E223
Normal file
@@ -0,0 +1,223 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda Green (AF)
|
||||
Device Model: ST2000DL003-9VT166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC32
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Jun 5 10:59:26 2020 -03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 254
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 612) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 334) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x30b7) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 114 099 006 - 76191712
|
||||
3 Spin_Up_Time PO---- 093 079 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 402
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 087 060 030 - 648398781
|
||||
9 Power_On_Hours -O--CK 044 044 000 - 49403
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 359
|
||||
183 Runtime_Bad_Block -O--CK 099 099 000 - 1
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 099 099 000 - 1
|
||||
188 Command_Timeout -O--CK 100 094 000 - 65615
|
||||
189 High_Fly_Writes -O-RCK 095 095 000 - 5
|
||||
190 Airflow_Temperature_Cel -O---K 063 052 045 - 37 (Min/Max 28/39)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 266
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 406
|
||||
194 Temperature_Celsius -O---K 037 048 000 - 37 (0 14 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 020 004 000 - 76191712
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 79
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 49387 (232 71 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 3367998481
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 1191976738
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 20 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2819 Device vendor specific log
|
||||
0xbd GPL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
Device Error Count: 1
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 21493 hours (895 days + 13 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 e8 29 0a e8 00 00 Error: UNC at LBA = 0xe8290ae8 = 3895003880
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 01 00 00 00 e8 29 0a 20 e0 00 22d+20:41:35.793 READ DMA EXT
|
||||
25 00 00 01 00 00 00 e8 29 09 20 e0 00 22d+20:41:35.793 READ DMA EXT
|
||||
35 00 00 00 08 00 00 94 17 2f e0 e0 00 22d+20:41:35.793 WRITE DMA EXT
|
||||
25 00 00 00 08 00 00 e8 29 09 18 e0 00 22d+20:41:35.792 READ DMA EXT
|
||||
35 00 00 00 28 00 00 94 17 2f b8 e0 00 22d+20:41:35.792 WRITE DMA EXT
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 49392 -
|
||||
# 2 Short offline Completed without error 00% 49368 -
|
||||
# 3 Short offline Completed without error 00% 49344 -
|
||||
# 4 Short offline Completed without error 00% 49320 -
|
||||
# 5 Short offline Completed without error 00% 49296 -
|
||||
# 6 Extended offline Completed without error 00% 49277 -
|
||||
# 7 Short offline Completed without error 00% 49248 -
|
||||
# 8 Short offline Completed without error 00% 49224 -
|
||||
# 9 Short offline Completed without error 00% 49200 -
|
||||
#10 Short offline Completed without error 00% 49176 -
|
||||
#11 Short offline Completed without error 00% 49152 -
|
||||
#12 Short offline Completed without error 00% 49128 -
|
||||
#13 Extended offline Completed without error 00% 49109 -
|
||||
#14 Short offline Completed without error 00% 49080 -
|
||||
#15 Short offline Completed without error 00% 49057 -
|
||||
#16 Short offline Completed without error 00% 49033 -
|
||||
#17 Short offline Completed without error 00% 49009 -
|
||||
#18 Short offline Completed without error 00% 48985 -
|
||||
#19 Short offline Completed without error 00% 48961 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/39 Celsius
|
||||
Lifetime Min/Max Temperature: 14/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (26)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 34 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
192
HDD/Seagate/ST2000/ST2000DL003-9VT166/F78691364020
Normal file
192
HDD/Seagate/ST2000/ST2000DL003-9VT166/F78691364020
Normal file
@@ -0,0 +1,192 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 11.3-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda Green (AF)
|
||||
Device Model: ST2000DL003-9VT166
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC32
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5900 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Fri Jun 5 10:59:27 2020 -03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 0 (vendor specific), recommended: 254
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 633) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 339) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x30b7) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 114 099 006 - 76173104
|
||||
3 Spin_Up_Time PO---- 093 092 000 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 020 - 1880
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 076 060 030 - 13029319093
|
||||
9 Power_On_Hours -O--CK 047 047 000 - 46861
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 020 - 1877
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 062 051 045 - 38 (Min/Max 29/40)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 1830
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 1940
|
||||
194 Temperature_Celsius -O---K 038 049 000 - 38 (0 17 0 0 0)
|
||||
195 Hardware_ECC_Recovered -O-RC- 021 004 000 - 76173104
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 46707 (67 225 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 1258048515
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 2144311778
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 2248 Device vendor specific log
|
||||
0xa8 GPL,SL VS 20 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 2819 Device vendor specific log
|
||||
0xbd GPL VS 252 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 46851 -
|
||||
# 2 Short offline Completed without error 00% 46827 -
|
||||
# 3 Short offline Completed without error 00% 46803 -
|
||||
# 4 Short offline Completed without error 00% 46779 -
|
||||
# 5 Short offline Completed without error 00% 46754 -
|
||||
# 6 Extended offline Completed without error 00% 46736 -
|
||||
# 7 Short offline Completed without error 00% 46706 -
|
||||
# 8 Short offline Completed without error 00% 46683 -
|
||||
# 9 Short offline Completed without error 00% 46658 -
|
||||
#10 Short offline Completed without error 00% 46634 -
|
||||
#11 Short offline Completed without error 00% 46610 -
|
||||
#12 Short offline Completed without error 00% 46586 -
|
||||
#13 Extended offline Completed without error 00% 46568 -
|
||||
#14 Short offline Completed without error 00% 46538 -
|
||||
#15 Short offline Completed without error 00% 46515 -
|
||||
#16 Short offline Completed without error 00% 46491 -
|
||||
#17 Short offline Completed without error 00% 46467 -
|
||||
#18 Short offline Completed without error 00% 46443 -
|
||||
#19 Short offline Completed without error 00% 46419 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/40 Celsius
|
||||
Lifetime Min/Max Temperature: 17/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 14/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (100)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 34 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
203
HDD/Seagate/ST2000/ST2000DM001-1CH164/2F08836FD104
Normal file
203
HDD/Seagate/ST2000/ST2000DM001-1CH164/2F08836FD104
Normal file
@@ -0,0 +1,203 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Seagate Barracuda 7200.14 (AF)
|
||||
Device Model: ST2000DM001-1CH164
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: CC43
|
||||
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 4
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Jun 4 17:28:49 2020 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART Status not supported: Incomplete response, ATA output registers missing
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
Warning: This result is based on an Attribute check.
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 584) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 227) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x3085) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 111 099 006 - 33611016
|
||||
3 Spin_Up_Time PO---- 098 095 000 - 0
|
||||
4 Start_Stop_Count -O--CK 100 100 020 - 953
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 068 058 030 - 21510906520
|
||||
9 Power_On_Hours -O--CK 076 076 000 - 21801
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 846
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 099 099 000 - 1
|
||||
188 Command_Timeout -O--CK 100 099 000 - 1 6 7
|
||||
189 High_Fly_Writes -O-RCK 098 098 000 - 2
|
||||
190 Airflow_Temperature_Cel -O---K 053 039 045 Past 47 (Min/Max 46/47 #9895)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 748
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 1650
|
||||
194 Temperature_Celsius -O---K 047 061 000 - 47 (0 8 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 21457h+10m+47.391s
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 46200378072
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 81212636385
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 20 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5176 Device vendor specific log
|
||||
0xbd GPL VS 512 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
Device Error Count: 1
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 667 hours (27 days + 19 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 00 00 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 04 00 00 00 00 00 00 e0 00 13:26:26.488 READ DMA EXT
|
||||
25 00 00 00 10 00 00 16 f1 11 d0 e0 00 07:31:40.042 READ DMA EXT
|
||||
25 00 00 00 f0 00 00 16 f1 10 e0 e0 00 07:31:40.024 READ DMA EXT
|
||||
25 00 00 00 10 00 00 16 f1 10 d0 e0 00 07:31:40.023 READ DMA EXT
|
||||
25 00 00 00 f0 00 00 16 f1 0f e0 e0 00 07:31:40.019 READ DMA EXT
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 5445 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 47 Celsius
|
||||
Power Cycle Min/Max Temperature: 46/47 Celsius
|
||||
Lifetime Min/Max Temperature: 7/61 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Data Table command not supported
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
Reference in New Issue
Block a user